A thermal circuit breaker is a resettable circuit-protection device. Unlike a single-use fuse, it mechanically opens its contacts when heat generated by overcurrent reaches the trip point. Within the broader hierarchy of circuit protection, the SI3069-A-FT combines a thermal sensing element and interrupting contact in a small package suitable for PCB-level integration.
The listed electrical ratings establish a 25 A current class with a 1-pole contact arrangement. Its dual 250 VAC and 50 VDC rating allows the same device family to address both alternating-current and direct-current systems, provided each application stays within the manufacturer’s specified mounting, calibration, and environmental limits. The two-terminal package also supports straightforward routing between the protected load and its supply node.
Because this device is thermal, its trip behavior depends on current magnitude, duration, ambient temperature, and the thermal path through the PCB. Sustained overload can therefore create a longer trip delay than a short-duration current surge. Designers should preserve the manufacturer’s recommended copper and solder geometry rather than treating the package as an unrestricted high-current connector.
Typical uses include overload protection for industrial control modules, auxiliary power branches in test and measurement equipment, and DC or AC input branches where a compact, manually resettable protective element is appropriate. Each branch must be selected against the exact voltage, current, and thermal environment required by the equipment rather than on the 25 A headline rating alone.
The primary layout consideration is current capacity: high-resistance solder joints or narrow copper traces can add unwanted temperature rise and contribute to nuisance tripping. Place the device in the uninterrupted protected-current path, use the prescribed land pattern, and keep high-current copper planes compact while maintaining adequate conductor width. Confirm the final arrangement with the manufacturer datasheet.
This page combines the identified ratings and lifecycle information with package-aware comparison fields, sourcing guidance, and practical protection-layout notes. Because a current schematic footprint and official pin table were not available, engineers should verify the land pattern and terminal numbering against the manufacturer documentation before fabrication.
के लिए ड्रॉप-इन विकल्प SI3069-A-FT — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।
इस सीरीज़ के वेरिएंट
समान श्रृंखला के मॉडल जो ड्रॉप-इन संगत हैं SI3069-A-FT (समान फॉर्म फैक्टर और फुटप्रिंट) — इसमें भिन्न Mounting Type, Product Type.
इस उत्पाद के लिए कोई drop-in alternatives उपलब्ध नहीं।
विकल्प अनुरोध करेंSI3069-A-FT विशेषताएं
| Product Type | Thermal circuit breaker interface IC |
| Rated Current | 25 A |
| Number of Poles | 1 pole |
| Maximum AC Voltage | 250 VAC |
| Maximum DC Voltage | 50 VDC |
| पिन काउंट | 2 pins |
| माउंटिंग प्रकार | Standard |
| Trip Mechanism | Thermal |
SI3069-A-FT standard पिन कॉन्फ़िगरेशन गाइड
SI3069-A-FT (standard पैकेज) के लिए पिन कॉन्फ़िगरेशन। पिन नंबरिंग, फ़ंक्शन और कनेक्शन आरेख निर्माता डेटाशीट में परिभाषित हैं। सटीक फुटप्रिंट और सोल्डरिंग दिशानिर्देशों के लिए इसे देखें।
इसके लिए कोई विस्तृत pinout data उपलब्ध नहीं: SI3069-A-FT.
देखें डेटाशीट पूर्ण पिन कॉन्फ़िगरेशन के लिए।
सामान्य अनुप्रयोग
SI3069-A-FT के लिए उपयुक्त है 6 अनुप्रयोगs: Industrial Control Branch Protection, DC Auxiliary Power Protection, Test and Measurement Input Protection, Power-Distribution Module Protection, Building Control and Automation Equipment, Embedded Equipment Replacement.
Industrial Control Branch Protection
The SI3069-A-FT fits an industrial control branch that requires a compact 1-pole thermal interrupter rated to 25 A and up to 250 VAC or 50 VDC. It can be placed in the input path of a controller, relay panel, or auxiliary power distribution board to interrupt sustained overloads. The principal design consideration is thermal repeatability: PCB copper, solder joints, enclosure temperature, and nearby heat sources all affect the trip point. Confirm that the 25 A rating represents the intended calibration and that the device’s verified operating-temperature range covers the cabinet interior. Because this MPN is obsolete, use it primarily for continuity of an existing qualified assembly rather than as the sole basis for a new production design.
अनुशंसित
DC Auxiliary Power Protection
The SI3069-A-FT is applicable to a 50 VDC auxiliary branch where a 25 A thermal circuit breaker provides overload protection for motors, heaters, or high-current control loads. Its 1-pole arrangement keeps the protection path compact, but the PCB layout still needs low-resistance connections so that unintended copper heating does not create an early trip. A fuse may appear electrically similar, yet its one-time behavior and current-time characteristic differ from a thermal breaker. Validate the breaker’s hold and trip currents against the minimum normal operating current and worst-case startup inrush. For new platforms, select a currently supported device with a documented 50 VDC and 25 A DC breaking rating rather than assuming the AC rating applies identically to DC arcs.
अनुशंसित
Test and Measurement Input Protection
The SI3069-A-FT can serve as an overload element in a test or measurement module that temporarily energizes a load through a protected branch. Its identified 25 A rating is appropriate only when the source, wiring, and load can sustain that level without creating excessive voltage drop or PCB heating. For automated test equipment, the protection device should be positioned where a failed DUT cannot repeatedly impose an overload on sensitive upstream circuitry. Because the SI3069-A-FT is obsolete, any redesigned instrument should use an active replacement with verified interrupt rating, trip curve, and operating temperature. Do not reuse the existing footprint unless the candidate device’s terminal arrangement, mounting method, and thermal calibration have been confirmed from authoritative documentation.
अनुशंसित
Power-Distribution Module Protection
The SI3069-A-FT is suited to a compact power-distribution module needing one protected branch for loads up to the device’s 25 A current class. The two-pin package can simplify board routing, but correct current sharing depends on wide, short copper paths and mechanically sound solder joints. Place the breaker where it can interrupt the branch without adding an unnecessary series resistance to precision analog or communication circuitry. Review the manufacturer’s thermal mounting guidance and use the prescribed copper geometry to maintain consistent trip calibration across production tolerances. Since the SI3069-A-FT is obsolete, preserve it for repair of a proven assembly and evaluate a currently supported equivalent for new production only after checking voltage, interruption capacity, trip timing, and terminal compatibility.
अनुशंसित
Building Control and Automation Equipment
The SI3069-A-FT can provide branch overload protection in a building-control unit that includes relays, contactors, or other inductive loads. The 250 VAC rating makes the device relevant to nominal low-voltage AC control circuits, but inductive load energy can create additional arcing and voltage stress at contact closure. Engineers should check the device’s permitted inductive-load category and test it with the actual relay coil, cable length, and suppression network. Thermal trip behavior also depends on ambient temperature inside the enclosure, so the mounting location should avoid hot regulators and power semiconductors. For new building-automation products, prefer a supported circuit protector whose documentation explicitly covers the required AC voltage, load category, ambient range, and reset behavior.
अनुशंसित
Embedded Equipment Replacement
The SI3069-A-FT is relevant to maintenance of embedded equipment whose original schematic used this obsolete 1-pole, 25 A thermal breaker. A repair should begin by confirming the exact terminal orientation, package drawing, protected branch, and trip characteristic rather than selecting a device solely by the 25 A marking. Mismatched hold current or trip delay can leave normal startup loads unprotected or cause repeated nuisance shutdowns. Request traceable obsolete stock through the Request a Quote form and inspect the returned device for mechanical damage before installation. For broader product redesigns, maintain the functional protection requirement in the system requirements while selecting a supported part with a verified footprint, interruption rating, thermal calibration, and lifecycle plan.
अनुशंसित
अनुशंसित उत्पादों का सारांश
के लिए इंजीनियरिंग संदर्भ डेटा SI3069-A-FT — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।
चयन गाइड
विकल्पों के साथ तुलना
| पैरामीटर | यह उत्पाद |
|---|---|
| Brand | Skyworks Solutions Inc. |
| Package | 2-pin package |
| Product Type | Thermal circuit breaker interface IC |
| Rated Current | 25 A |
| Maximum AC Voltage | 250 VAC |
| Maximum DC Voltage | 50 VDC |
| Number of Poles | 1 pole |
| Trip Mechanism | Thermal |
| Mounting Type | Standard |
| Lifecycle Status | Obsolete |
मुख्य विशेषताएँ
- Defined 25 A thermal-breaker rating (बनामGeneric 25 A fuse)
- Supports both AC and DC voltage classes (बनामSingle-voltage breaker)
- Compact two-terminal integration (बनामLarger panel-mount breaker)
डिज़ाइन नोट्स
Estimated: the trip point is influenced by I²R heating in the protected path and the thermal resistance from the device to its PCB copper. Using the 25 A rated current and the device resistance R, conductor heating is P = 25² × R; even a small additional resistance can create noticeable heat. Use the manufacturer’s prescribed copper dimensions and avoid placing the breaker beside heat-generating components. Validate the final trip curve in the intended enclosure and ambient range.
The SI3069-A-FT must be placed in the uninterrupted protected-current path rather than on a thin branch that becomes the weakest conductor unintentionally. Use the official land pattern, full recommended copper width, and short return path to the protected load. Avoid long neck-downs, exposed pads, or solder joints with poor wetting because these increase resistance and can shift thermal behavior. Confirm terminal numbering and package orientation mechanically before releasing a PCB revision.
Do not interpret the 25 A marking as permission for 25 A of continuous load without checking the calibration, ambient temperature, conductor capacity, and device mounting method. Also distinguish 250 VAC from 50 VDC: contact interruption behavior differs between AC and DC loads. Because this MPN is obsolete, do not approve a new design solely from a catalog headline; obtain authoritative electrical, thermal, dimensional, and lifecycle documentation for the exact device.
Where the breaker controls a DC inductive load, add the manufacturer-approved flyback or suppression network and confirm that load-generated voltage and current remain within the device’s switching ratings. A 50 VDC supply can produce an inductive arc even when steady-state current is below 25 A. Review the exact contact topology and load category before applying the SI3069-A-FT to motors, solenoids, or relay coils.
अनुपालन जानकारी
The obsolete circuit-breaker device is not an automotive component, so AEC-Q100 is not applicable. RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations were not identified and remain unknown.