TJA1040T/VM - 1Mbit CAN Transceiver | NXP | Automotive
MPN: TJA1040T/VM ✗ انتهى عمره الإنتاجيTJA1040T/VM نظرة عامة
A CAN transceiver is an interface IC within the broader hierarchy of CAN interface devices, bus transceivers, wired-network interfaces, and semiconductors. It translates logic-level TXD and RXD signals into the differential CANH and CANL bus conductors and converts received bus differential voltage back into a logic-compatible RXD signal. This physical-layer function separates CAN protocol processing in a controller from the electrical drive, receive, and bus-failure behavior implemented by the transceiver.
The TJA1040 supports high-speed CAN operation up to 1 Mbaud, making it appropriate for engine, chassis, body, and other automotive networks operating within that bandwidth. Its 5 V supply arrangement matches conventional automotive CAN interface environments. The device also provides power-down and standby operating states, allowing a system to reduce activity when communication is not required. The listed 8-SO package supports compact surface-mount PCB layouts.
The transceiver architecture combines a differential CAN output stage with a differential input receiver. TXD is the controller-facing transmit input, while RXD is the controller-facing receive output. CANH and CANL provide the physical connection to the bus, VCC supplies the transceiver, VIO supports the interface voltage domain, and EN provides operating-state control. These functions allow a CAN controller to communicate through a multi-conductor differential bus while keeping protocol handling separate from bus signaling.
Typical applications include passenger-car CAN networks, automotive body and chassis control modules, powertrain control equipment, industrial CAN equipment operating at compatible bus speeds, and embedded CAN gateways. In each application, the controller generates TXD and receives RXD, while the TJA1040 handles the physical bus interface. Board design must preserve the transceiver's supply, reference-ground, input, and bus-connection requirements to maintain signal integrity.
When laying out the PCB, place the transceiver and its local decoupling capacitor close to the associated CAN controller, keep CANH and CANL routing compact and symmetrical, and provide the bus termination and common-mode network required by the selected CAN topology. Differential routing reduces sensitivity to external noise, while correct termination prevents excessive reflections from degrading communication at the maximum supported data rate.
This product page combines the NXP device description with package, interface, application, comparison, and layout guidance. It also distinguishes verified source facts from engineering choices that depend on bus topology, termination strategy, controller supply voltage, and EMC validation.
بدائل مباشرة لـ TJA1040T/VM — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.
الطرازات في هذه السلسلة
طرازات من نفس السلسلة متوافقة تمامًا مع TJA1040T/VM (نفس عامل الشكل والبصمة) — يختلف في Package, Product Type, Standby Control.
TJA1040T/CM,118
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
TJA1042T/3,1
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
TJA1044T
✅ بديل مباشرتواصل لمعرفة السعر
عرض ورقة البيانات ←SN65HVDA1040A
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
TJA1040T/VM المواصفات
| Product Type | CAN physical-layer transceiver |
| Maximum CAN Data Rate | 1 Mbaud |
| جهد التغذية | 5 V |
| Transceiver Configuration | Half CANbus transceiver |
| Transmit Capability | Differential |
| Receive Capability | Differential |
| Operating Modes | Power-down and standby |
| العلبة | 8-SO package, 8 leads |
| نوع التركيب | Surface mount |
| Primary Application | Passenger-car high-speed CAN networks |
| Controller Interface | TXD input and RXD output |
| CAN Bus Interface | CANH and CANL differential conductors |
تكوين أطراف TJA1040T/VM
| دبوس 1 | TXD — Transmit data input from the CAN controller |
| دبوس 2 | GND — Ground connection |
| دبوس 3 | VIO — Input and output logic voltage reference |
| دبوس 4 | EN — Enable input for operating-state control |
| دبوس 5 | CANL — CAN low bus output and input |
| دبوس 6 | CANH — CAN high bus output and input |
| دبوس 7 | VCC — Transceiver supply connection |
| دبوس 8 | RXD — Receive data output to the CAN controller |
التطبيقات النموذجية
TJA1040T/VM مناسب لـ 6 التطبيقs: Passenger-Car CAN Networks, Automotive Body-Control Modules, Chassis and Powertrain Control, Industrial CAN Control Equipment, Embedded CAN Gateways, CAN Test and Measurement.
Passenger-Car CAN Networks
The TJA1040T/VM fits a passenger-car CAN network because the NXP TJA1040 family is intended for high-speed CAN communication up to 1 Mbaud. The transceiver sits between the CAN controller and CANH/CANL, while TXD and RXD connect directly to the controller's digital interface. In a body, chassis, or powertrain module, this separation keeps protocol processing outside the physical driver. The 8-SO package also supports compact surface-mount layouts. Existing automotive programs should retain the exact component qualification, EMC validation, and bus-network configuration rather than changing devices solely for availability.
موصى به
Automotive Body-Control Modules
A body-control module can use the TJA1040T/VM as the physical interface to a 1 Mbaud CAN network carrying door, lighting, climate, or centralized body-control traffic. TXD accepts the controller's transmit command, while RXD presents the received bus state to the controller. CANH and CANL connect to the harness through the board's bus interface and protection network. The 5 V supply arrangement fits conventional controller environments, but production deployment still requires confirmation of the exact operating-temperature grade, automotive qualification, ESD strategy, and electromagnetic-immunity performance for the vehicle program.
موصى به
Chassis and Powertrain Control
The TJA1040T/VM can provide the CAN physical layer for chassis or powertrain-control electronics that exchange high-speed messages with other vehicle nodes. At the supported bus rate of up to 1 Mbaud, the differential CANH/CANL interface helps carry logic signals reliably across a multi-node harness while the controller manages message scheduling and diagnostics. The circuit must be designed around the exact bus topology, including termination, common-mode components, protection, and grounding. Validate transient immunity, radiated emissions, and fault behavior in the final ECU because those system-level outcomes depend on the surrounding harness and board implementation.
موصى به
Industrial CAN Control Equipment
The TJA1040T/VM can serve in industrial CAN control equipment that uses a 1 Mbaud-compatible bus for machine control, diagnostics, or distributed I/O. The transceiver provides the differential physical layer between a CAN controller and a long printed-circuit-board or cable network, while the 8-SO package keeps the interface compact. Because industrial systems may use different wiring lengths, isolation arrangements, and fault requirements, verify the common-mode range, termination, isolation strategy, and surge exposure against the manufacturer limits. The CAN protocol and bus topology should remain compatible with the device's stated 1 Mbaud capability.
موصى به
Embedded CAN Gateways
An embedded gateway can use the TJA1040T/VM as the physical-layer endpoint between a host processor or microcontroller and a CAN field bus. The controller's TXD signal drives the differential bus, and the transceiver's RXD signal reports received activity to the host. This arrangement is useful when the host does not integrate a CAN physical layer and requires a discrete 8-SO transceiver. Design the PCB with a short return path, local supply bypassing, defined bus termination, and protection appropriate to the external wiring. Confirm the controller's I/O voltage against VIO and retest timing at the maximum intended bus load.
موصى به
CAN Test and Measurement
The TJA1040T/VM can form the bus-side interface of a CAN test fixture, protocol analyzer, or diagnostic interface operating at a compatible rate up to 1 Mbaud. TXD allows the tester to generate bus traffic, while RXD allows a controller to observe received frames. The differential CANH/CANL arrangement provides a standard physical layer for connecting the fixture to a vehicle or industrial CAN network. For bench equipment, include switchable termination, protected bus connectors, and a controlled ground strategy. Verify recessive and dominant voltage levels with the production load because the logic thresholds and bus-driver implementation determine measurement margins.
موصى به
ملخص المنتجات الموصى بها
بيانات مرجعية هندسية لـ TJA1040T/VM — المقارنة وإرشادات التصميم ومعلومات الامتثال.
دليل الاختيار
المقارنة مع البدائل
| المعامل | هذا المنتج | TJA1040T/CM,118 | TJA1042T/3,1 | TJA1044T | SN65HVDA1040A |
|---|---|---|---|---|---|
| Brand | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | Texas Instruments |
| Package | SOIC-8 | SOIC-8 - same package | SOIC-8 - same package | SOIC-8 - same package | SOIC-8 - same package |
| Product Type | CAN physical-layer transceiver | CAN physical-layer transceiver | CAN physical-layer transceiver | CAN physical-layer transceiver | CAN physical-layer transceiver |
| Maximum Data Rate | 1 Mbaud | 1 Mbaud | Not stated in cited comparison material | Not stated in cited comparison material | High-speed CAN class |
| Transmit Interface | Differential CANH/CANL | Differential CANH/CANL | Differential CANH/CANL | Differential CANH/CANL | Differential CANH/CANL |
| Receive Interface | Differential RXD output | Differential RXD output | Differential RXD output | Differential RXD output | Differential RXD output |
| Power-Down and Standby | Supported | Supported | Not stated in cited comparison material | Not stated in cited comparison material | Not stated in cited comparison material |
| Supply Voltage | 5 V | Not stated in cited comparison material | Not stated in cited comparison material | Not stated in cited comparison material | Not stated in cited comparison material |
| Controller Interface | TXD and RXD | TXD and RXD | TXD and RXD | TXD and RXD | TXD and RXD |
| Lifecycle Status | Obsolete | Not stated in cited comparison material | Not stated in cited comparison material | Not stated in cited comparison material | Not stated in cited comparison material |
أبرز الفروقات
- Established 1 Mbaud TJA1040 interface (مقابلTJA1042T/3,1)
- Same-manufacturer 8-SO alternative with 1 Mbaud class (مقابلTJA1040T/CM,118)
- Documented power-down and standby operation (مقابلSN65HVDA1040A)
ملاحظات التصميم
Place the TJA1040T/VM close to the CAN controller and place its local supply-decoupling capacitor at the VCC and ground pins. Keep CANH and CANL as a compact, closely coupled differential pair, with a continuous ground reference beneath the pair where the board stackup permits. Route the pair away from switching nodes, high-current edges, and unrelated clocks. Correct differential geometry reduces radiated emissions and improves immunity to external bus noise.
Do not assume that every 8-SO CAN transceiver is automatically interchangeable. Before substituting an alternative, compare TXD and RXD thresholds against the controller voltage, VIO behavior, EN polarity, standby or sleep timing, CANH/CANL output levels, common-mode range, bus-fault protection, and loopback implementation. A package match alone does not guarantee timing or electrical compatibility. Record the exact datasheet revision and validate the candidate in the complete CAN network.
Apply the termination network specified for the complete CAN topology rather than adding termination blindly at every node. Keep the termination components close to the transceiver or bus connector, and keep the CANH-to-CANL loop area small. Provide the required common-mode network near the bus interface and use a ground strategy that minimizes common-mode conversion. Confirm that chassis, shield, and signal-ground connections follow the vehicle or industrial network architecture.
The listed operating supply is 5 V, while VIO establishes the logic domain used by TXD and RXD. Verify the exact VIO range from the manufacturer datasheet and ensure it matches the CAN controller's I/O voltage. Provide local high-frequency bypassing at VCC and a clean ground return. Confirm startup, standby, and power-down sequencing so the controller does not interpret an uncontrolled bus or pin state as valid traffic during reset.
معلومات الامتثال
The cited manufacturer and distributor snippets do not provide explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations for the exact TJA1040T/VM ordering code. Consult the current NXP product page and the applicable NXP material declaration before production release.