INA126U/2K5 - 36V MicroPower Instrumentation Amplifier | Texas Instruments
MPN: INA126U/2K5 ✓ সক্রিয়INA126U/2K5 সারাংশ
An instrumentation amplifier is a specialized amplifier that measures the voltage difference between two inputs while rejecting common-mode voltage. Its place in the signal-chain hierarchy is sensor front end → instrumentation amplifier → precision analog signal chain. Unlike a general-purpose operational amplifier, an instrumentation amplifier provides purpose-built differential input handling and high common-mode rejection for bridges, sensors, and measurement systems.
The INA126 family provides low quiescent current of 175 µA per channel and supports supply voltages from ±1.35 V to ±18 V. Its 250 µV offset specification supports accurate measurement of small differential signals, while the wide 36 V total supply range permits operation from compact dual supplies or a single supply when the signal and reference levels are compatible with the device architecture.
The INA126 uses a two-op-amp instrumentation-amplifier topology rather than a three-op-amp configuration. This reduces circuit complexity and can reduce board area, while preserving the differential-input behavior required by precision measurement systems. The gain arrangement associated with the /2K5 ordering option distinguishes this version from other INA126 gain and package configurations, so the full ordering information should be checked before substituting a part in an existing design.
Typical uses include bridge-transducer excitation and readout, battery-powered sensor acquisition, current measurement, industrial process monitoring, and portable medical or test equipment. Low quiescent current is particularly valuable when the amplifier must remain active while the overall instrument consumes little power. The 36 V supply capability also supports higher-voltage industrial measurement systems when appropriate input common-mode and output-range conditions are met.
When laying out the circuit, use the pin-description table in the manufacturer datasheet for all connections and preserve the reference and supply decoupling arrangement shown by Texas Instruments. Input filtering, resistor placement, and guarding can materially affect accuracy in high-impedance sensor nodes. The output-reference connection should also be treated as part of the measurement system because its voltage influences the output level and can be used for bipolar-signal offsetting.
This page combines the manufacturer product description, ordering distinctions, cross-reference findings, comparison guidance, and practical implementation advice. It highlights where the INA126U/2K5 fits in low-power precision acquisition and identifies the parameter checks engineers should complete before approving a replacement or redesign.
এর জন্য ড্রপ-ইন বিকল্প INA126U/2K5 — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।
এই সিরিজের ভ্যারিয়েন্ট
একই সিরিজের মডেল যেগুলো drop-in compatible INA126U/2K5 (একই form factor এবং footprint) — পার্থক্য রয়েছে Quiescent Current, Package, Architecture, Number of Channels, Product Type.
INA126UA/2K5
✅ ড্রপ-ইন📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)
INA126U
✅ ড্রপ-ইনমূল্যের জন্য যোগাযোগ করুন
ডেটাশিট দেখুন →INA128UA/2K5
✅ ড্রপ-ইন📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)
INA122UA
✅ ড্রপ-ইনমূল্যের জন্য যোগাযোগ করুন
ডেটাশিট দেখুন →INA126U/2K5 সর্বোচ্চ রেটিং ও বৈদ্যুতিক বৈশিষ্ট্য
| Product Type | Precision instrumentation amplifier |
| Maximum Supply Voltage | 36 V |
| অপারেটিং সাপ্লাই ভোল্টেজ | ±1.35 V to ±18 V |
| কুইসেন্ট কারেন্ট | 175 µA per channel |
| Input Offset Voltage | 250 µV |
| Internal Architecture | Two-op-amp design |
| Number of Channels | 1 channel |
| প্যাকেজ | 8-pin SOIC |
| মাউন্টিং টাইপ | Surface mount |
| Terminal Count | 8 terminals |
| Signal Type | Differential |
| Application Class | Low-level differential signal acquisition |
| Power Class | Micropower |
INA126U/2K5 পিন কনফিগারেশন
| পিন 1 | RG — Gain-network connection |
| পিন 2 | IN- — Inverting input |
| পিন 3 | IN+ — Noninverting input |
| পিন 4 | V- — Negative supply connection |
| পিন 5 | REF — Reference input |
| পিন 6 | OUT — Output |
| পিন 7 | V+ — Positive supply connection |
| পিন 8 | RG — Gain-network connection |
সাধারণ ব্যবহার
INA126U/2K5 এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: Battery-Powered Sensor Acquisition, Bridge-Transducer Readout, Portable Medical Instrumentation, Industrial Process Measurement, Current-Shunt Measurement, Data Acquisition and Test Equipment.
Battery-Powered Sensor Acquisition
The INA126U/2K5 fits battery-powered sensor acquisition because its 175 µA quiescent current limits standby demand while providing differential input conditioning and a 250 µV offset specification. Place the device close to the sensor outputs so the small differential signal is amplified before cable, connector, or board leakage contributes noise. The /2K5 ordering option defines the gain configuration, while the REF connection establishes the output reference. This arrangement is appropriate for portable measurement instruments where every microamp of standby current affects battery life.
সুপারিশকৃত
Bridge-Transducer Readout
A precision bridge transducer benefits from the INA126U/2K5 because instrumentation-amplifier architecture rejects common-mode voltage and converts the small differential bridge imbalance into a measurable output. The 250 µV offset specification helps preserve accuracy when excitation is controlled and the bridge imbalance is small. Use closely matched gain-network resistors when gain accuracy matters, and connect the reference pin according to the manufacturer application circuit. Check input common-mode limits against the bridge excitation range before finalizing the sensor interface.
সুপারিশকৃত
Portable Medical Instrumentation
The INA126U/2K5 is appropriate for portable medical instrumentation when a low-level differential biological or physiological signal must be acquired with limited power consumption. Its 175 µA quiescent current supports longer operating time from compact cells, while the two-op-amp architecture provides a straightforward differential front end. The input bias current and common-mode range must be checked against the sensor-electrode interface, and patient-safety, leakage, and isolation requirements must be satisfied by the complete system rather than the amplifier alone.
সুপারিশকৃত
Industrial Process Measurement
The INA126U/2K5 supports industrial process measurement when a low-level differential signal must be extracted from a higher common-mode environment. The 36 V maximum supply rating is useful for higher-voltage systems, and the precision instrumentation-amplifier topology supports accurate signal acquisition. Its micropower operation can also reduce power in distributed monitoring nodes. Apply input filtering carefully, keep high-impedance routes short, and verify that the operating common-mode voltage and output swing remain valid through every process range.
সুপারিশকৃত
Current-Shunt Measurement
The INA126U/2K5 can serve as the differential input stage for a low-value shunt when the required bandwidth, common-mode range, and gain match the application. The two-op-amp instrumentation topology isolates the shunt voltage from supply and ground disturbances, while the 250 µV offset specification is relevant to measurements near zero current. Use Kelvin routing and avoid sharing narrow copper paths with the shunt-current force connection. Compare the amplifier’s slew rate and gain-bandwidth behavior with the expected transient current profile.
সুপারিশকৃত
Data Acquisition and Test Equipment
The INA126U/2K5 is suitable for precision data-acquisition front ends that must amplify a differential sensor or source while consuming little standby power. Its 175 µA quiescent current leaves more of the power budget for converters, references, and digital conversion stages. The 250 µV offset value helps with low-level measurements, but total error also depends on drift, bias current, resistor accuracy, and reference quality. For multis-channel systems, evaluate channel matching and whether an instrumentation amplifier is preferable to multiplexing a lower-cost amplifier.
সুপারিশকৃত
সুপারিশকৃত পণ্যের সারসংক্ষেপ
এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা INA126U/2K5 — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।
নির্বাচন গাইড
বিকল্পের সাথে তুলনা
| পারামিটার | এই পণ্য | INA126UA/2K5 | INA126U | INA128UA/2K5 | INA122UA |
|---|---|---|---|---|---|
| Package | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Product Family | INA126 micropower precision instrumentation amplifier | INA126 | INA126 | INA128 | INA122 |
| Gain Ordering Code | /2K5 | /2K5 | No /2K5 suffix | /2K5 | No /2K5 suffix |
মূল পার্থক্যসমূহ
- Closest documented same-family ordering option (বনামINA126UA/2K5)
- Lower standby demand than the INA128 alternative (বনামINA128UA/2K5)
- Exact gain-ordering retention versus unqualified INA126U (বনামINA126U)
ডিজাইন নোট
Place the INA126U/2K5 close to the differential source and keep the IN+ and IN− routes short and symmetric. High-impedance sensor nodes are sensitive to leakage from PCB contamination, so use a suitable board finish, guard the input nodes where appropriate, and avoid routing the input traces beside high-impedance or switching nodes. Follow the manufacturer application circuit for the gain resistors and reference connection.
Decouple the positive and negative supply pins locally, using the capacitance and placement shown in the Texas Instruments application circuit. The 175 µA quiescent current is beneficial for portable systems, but supply current still rises with output activity and load. Ensure that the selected supply mode keeps both input pins and the output inside their permitted common-mode and output-swing ranges.
Do not select a substitute from the SOIC-8 outline alone. INA126UA/2K5 retains the /2K5 ordering option and is the closest documented TI candidate, while INA128UA/2K5 and INA122UA belong to different families with different electrical characteristics. Confirm gain-network pins, reference behavior, input bias current, common-mode range, output swing, bandwidth, and supply limits before approving any replacement.
কমপ্লায়েন্স তথ্য
The available manufacturer and distributor pages do not provide explicit compliance values for the exact INA126U/2K5 ordering code. Compliance must be confirmed from the manufacturer product page or declaration associated with the selected lot.