Texas Instruments

INA126U/2K5 - 36V MicroPower Instrumentation Amplifier | Texas Instruments

MPN: INA126U/2K5 ✓ فعال
36 V Vdss 175 µA per channel Id 8-pin SOIC Package
حداقل سفارش: 1 |

INA126U/2K5 نمای کلی

Texas Instruments INA126U/2K5 is a precision, micropower instrumentation amplifier with a 36 V maximum supply voltage, 175 µA quiescent current, and 250 µV input offset voltage, supplied in an 8-pin SOIC package. Designed for low-level differential-signal acquisition, it combines a two-op-amp architecture with high input impedance and low power consumption for portable instrumentation, industrial measurement, and sensor-interface applications.

An instrumentation amplifier is a specialized amplifier that measures the voltage difference between two inputs while rejecting common-mode voltage. Its place in the signal-chain hierarchy is sensor front end → instrumentation amplifier → precision analog signal chain. Unlike a general-purpose operational amplifier, an instrumentation amplifier provides purpose-built differential input handling and high common-mode rejection for bridges, sensors, and measurement systems.

The INA126 family provides low quiescent current of 175 µA per channel and supports supply voltages from ±1.35 V to ±18 V. Its 250 µV offset specification supports accurate measurement of small differential signals, while the wide 36 V total supply range permits operation from compact dual supplies or a single supply when the signal and reference levels are compatible with the device architecture.

The INA126 uses a two-op-amp instrumentation-amplifier topology rather than a three-op-amp configuration. This reduces circuit complexity and can reduce board area, while preserving the differential-input behavior required by precision measurement systems. The gain arrangement associated with the /2K5 ordering option distinguishes this version from other INA126 gain and package configurations, so the full ordering information should be checked before substituting a part in an existing design.

Typical uses include bridge-transducer excitation and readout, battery-powered sensor acquisition, current measurement, industrial process monitoring, and portable medical or test equipment. Low quiescent current is particularly valuable when the amplifier must remain active while the overall instrument consumes little power. The 36 V supply capability also supports higher-voltage industrial measurement systems when appropriate input common-mode and output-range conditions are met.

When laying out the circuit, use the pin-description table in the manufacturer datasheet for all connections and preserve the reference and supply decoupling arrangement shown by Texas Instruments. Input filtering, resistor placement, and guarding can materially affect accuracy in high-impedance sensor nodes. The output-reference connection should also be treated as part of the measurement system because its voltage influences the output level and can be used for bipolar-signal offsetting.

This page combines the manufacturer product description, ordering distinctions, cross-reference findings, comparison guidance, and practical implementation advice. It highlights where the INA126U/2K5 fits in low-power precision acquisition and identifies the parameter checks engineers should complete before approving a replacement or redesign.

جایگزین‌های drop-in برای INA126U/2K5 — همان پکیج، سازگار پین‌به‌پین. قطعات با پکیج متفاوت که نیاز به تغییر PCB دارند مستثنی هستند.

گونه‌ها در این سری

مدل‌های هم‌سری که جایگزین مستقیم هستند برای INA126U/2K5 (همان فرم‌فاکتور و فوت‌پرینت) — متفاوت در Quiescent Current, Package, Architecture, Number of Channels, Product Type.

Texas Instruments
Quiescent Current: ±450 µA
Architecture: Three-op-amp instrumentation-amplifier design
Number of Channels: 1 circuit
Texas Instruments
Quiescent Current: 60 uA
Architecture: Two-op-amp design
Number of Channels: 1 circuit
Texas Instruments
Package: 8-pin SOIC, 3.90 mm width
Architecture: Two-op-amp design

INA126UA/2K5

✅ جایگزین مستقیم
📦 8-SOIC
Same INA126 family and /2K5 gain ordering; UA is identified by Texas Instruments as the replacement for INA126PA, with package and temperature-grade attributes requiring ordering-table confirmation.

📋 جایگزین مرجع (خارج از کاتالوگ)

INA126U

✅ جایگزین مستقیم
Texas Instruments
📦 8-SOIC
Single-circuit micropower precision instrumentation amplifier · 36 V · ±1.35 V to ±18 V · 175 µA per channel · 250 µV · Two-op-amp design · 1 amplifier · Differential signal acquisition

برای قیمت تماس بگیرید

مشاهده دیتاشیت ←

INA128UA/2K5

✅ جایگزین مستقیم
📦 8-SOIC
Shares the 8-SOIC format and /2K5 ordering gain, but belongs to the INA128 family with different electrical characteristics from the 175 µA INA126.

📋 جایگزین مرجع (خارج از کاتالوگ)

INA122UA

✅ جایگزین مستقیم
Texas Instruments
📦 8-SOIC
Precision instrumentation amplifier · Two-op-amp design · 1 circuit · 2.2 V to 36 V · +/-18 V · 60 uA · 120 kHz · Approximately 0.1 V below the negative supply

برای قیمت تماس بگیرید

مشاهده دیتاشیت ←

INA126U/2K5 حداکثر مقادیر مجاز و مشخصات الکتریکی

Product Type Precision instrumentation amplifier
Maximum Supply Voltage 36 V
ولتاژ تغذیه کاری ±1.35 V to ±18 V
جریان سکون 175 µA per channel
Input Offset Voltage 250 µV
Internal Architecture Two-op-amp design
Number of Channels 1 channel
بسته‌بندی 8-pin SOIC
نوع نصب Surface mount
Terminal Count 8 terminals
Signal Type Differential
Application Class Low-level differential signal acquisition
Power Class Micropower

پیکربندی پین INA126U/2K5

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
پین 1 RG — Gain-network connection
پین 2 IN- — Inverting input
پین 3 IN+ — Noninverting input
پین 4 V- — Negative supply connection
پین 5 REF — Reference input
پین 6 OUT — Output
پین 7 V+ — Positive supply connection
پین 8 RG — Gain-network connection

کاربردهای معمول

INA126U/2K5 مناسب است برای 6 کاربردs: Battery-Powered Sensor Acquisition, Bridge-Transducer Readout, Portable Medical Instrumentation, Industrial Process Measurement, Current-Shunt Measurement, Data Acquisition and Test Equipment.

🔋

Battery-Powered Sensor Acquisition

The INA126U/2K5 fits battery-powered sensor acquisition because its 175 µA quiescent current limits standby demand while providing differential input conditioning and a 250 µV offset specification. Place the device close to the sensor outputs so the small differential signal is amplified before cable, connector, or board leakage contributes noise. The /2K5 ordering option defines the gain configuration, while the REF connection establishes the output reference. This arrangement is appropriate for portable measurement instruments where every microamp of standby current affects battery life.

🏭

Bridge-Transducer Readout

A precision bridge transducer benefits from the INA126U/2K5 because instrumentation-amplifier architecture rejects common-mode voltage and converts the small differential bridge imbalance into a measurable output. The 250 µV offset specification helps preserve accuracy when excitation is controlled and the bridge imbalance is small. Use closely matched gain-network resistors when gain accuracy matters, and connect the reference pin according to the manufacturer application circuit. Check input common-mode limits against the bridge excitation range before finalizing the sensor interface.

💊

Portable Medical Instrumentation

The INA126U/2K5 is appropriate for portable medical instrumentation when a low-level differential biological or physiological signal must be acquired with limited power consumption. Its 175 µA quiescent current supports longer operating time from compact cells, while the two-op-amp architecture provides a straightforward differential front end. The input bias current and common-mode range must be checked against the sensor-electrode interface, and patient-safety, leakage, and isolation requirements must be satisfied by the complete system rather than the amplifier alone.

🏭

Industrial Process Measurement

The INA126U/2K5 supports industrial process measurement when a low-level differential signal must be extracted from a higher common-mode environment. The 36 V maximum supply rating is useful for higher-voltage systems, and the precision instrumentation-amplifier topology supports accurate signal acquisition. Its micropower operation can also reduce power in distributed monitoring nodes. Apply input filtering carefully, keep high-impedance routes short, and verify that the operating common-mode voltage and output swing remain valid through every process range.

⚡

Current-Shunt Measurement

The INA126U/2K5 can serve as the differential input stage for a low-value shunt when the required bandwidth, common-mode range, and gain match the application. The two-op-amp instrumentation topology isolates the shunt voltage from supply and ground disturbances, while the 250 µV offset specification is relevant to measurements near zero current. Use Kelvin routing and avoid sharing narrow copper paths with the shunt-current force connection. Compare the amplifier’s slew rate and gain-bandwidth behavior with the expected transient current profile.

🖥️

Data Acquisition and Test Equipment

The INA126U/2K5 is suitable for precision data-acquisition front ends that must amplify a differential sensor or source while consuming little standby power. Its 175 µA quiescent current leaves more of the power budget for converters, references, and digital conversion stages. The 250 µV offset value helps with low-level measurements, but total error also depends on drift, bias current, resistor accuracy, and reference quality. For multis-channel systems, evaluate channel matching and whether an instrumentation amplifier is preferable to multiplexing a lower-cost amplifier.

What are the key specifications of INA126U/2K5 that engineers should know?
The INA126U/2K5 is a single-channel, precision micropower instrumentation amplifier in an 8-pin SOIC package. According to the Texas Instruments INA126 product page and manufacturer datasheet, its principal specifications include a 36 V maximum supply voltage, 175 µA quiescent current, 250 µV input offset voltage, and a two-op-amp architecture. These characteristics make it suitable for low-level differential measurements where power consumption, common-mode rejection, and offset performance are important.
What is the operating voltage of INA126U/2K5?
The INA126U/2K5 supports an operating supply range of ±1.35 V to ±18 V, corresponding to a total span of 2.7 V to 36 V. According to the Texas Instruments manufacturer datasheet, this range permits use with low-voltage dual supplies as well as higher-voltage industrial rails. The allowed input common-mode range, output swing, and gain setting must also remain within their respective limits for accurate operation.
Where can I download the INA126U/2K5 datasheet PDF?
The official INA126U/2K5 datasheet PDF is available from Texas Instruments at https://www.ti.com/lit/ds/symlink/ina126.pdf. The document is titled “INAx126 MicroPower Instrumentation Amplifiers” and contains the device description, electrical characteristics, pin descriptions, typical application circuits, and ordering information. Use the manufacturer PDF for final pin assignments, maximum ratings, gain settings, and application guidance.
Where can I find the INA126U/2K5 pinout?
The INA126U/2K5 pinout is documented in the pin-description section of the Texas Instruments INA126 datasheet and in the 8-pin SOIC package diagram. Its eight connections implement differential input, output, dual supply pins, reference input, and gain-network connections. Use the pin-description table when assigning PCB tracks because the SOIC numbering follows the package drawing rather than the functional grouping of the circuit.
How much current does INA126U/2K5 consume?
The INA126 family operates at a low quiescent current of 175 µA per channel. According to the Texas Instruments manufacturer datasheet, this micropower operating current supports portable instrumentation, sensor interfaces, and battery-powered measurement systems. Actual supply consumption depends on the operating voltages, output activity, load, and the selected operating mode, so use the datasheet conditions when comparing battery-life estimates.
Where to buy INA126U/2K5 online?
The INA126U/2K5 can be requested through the Request a Quote form on this page. The form is the appropriate channel for current availability, lot traceability, quantity requirements, and lead-time confirmation. The component is identified as an active Texas Instruments instrumentation amplifier in an 8-pin SOIC package, with the manufacturer product page available for official ordering information.
What is the price of INA126U/2K5?
Current pricing for the INA126U/2K5 is available through the Request a Quote form on this page. Submit the required quantity and packaging details to obtain a current quotation and stock confirmation. Because distributor inventory and commercial terms can change, a request is more reliable than using a historical unit-price reference when preparing a production BOM.
What is the lead time for INA126U/2K5?
Request the current lead time for INA126U/2K5 through the Request a Quote form on this page. Include the purchase quantity, authorized distribution requirements, and target date so the supplier can confirm the appropriate manufacturing and logistics path. Texas Instruments lists the INA126 family as active, but project-specific lead time should always be confirmed for the exact ordering code.
Is INA126U/2K5 in stock?
Use the Request a Quote form on this page to check current INA126U/2K5 stock and allocation for your required quantity. The manufacturer product page identifies the INA126 family as active, but that status alone does not establish warehouse quantity for a particular lot. Quote requests should include the desired package form and production schedule to obtain a meaningful availability response.
What can replace INA126U/2K5?
INA126UA/2K5 is the closest documented TI replacement candidate because Texas Instruments identifies it as the replacement for the obsolete INA126PA and it retains the same gain-ordering code. Before approving it, confirm the exact package drawing, pin assignments, electrical limits, and ordering suffix in the manufacturer datasheet. Other INA-family amplifiers can provide similar differential-measurement functions but are not automatically exact drop-in replacements.
Is INA126U/2K5 the same as INA128UA/2K5?
No. The INA126U/2K5 is a 175 µA micropower precision instrumentation amplifier, while the INA128UA/2K5 belongs to a different INA128 family with different electrical characteristics. Both may use an 8-pin SOIC-style package and /2K5 gain ordering, but package similarity does not establish pin-to-pin compatibility or equivalent noise, bandwidth, supply, and common-mode performance. Verify the manufacturer pinouts and parameters before substitution.
INA126U/2K5 vs INA126UA/2K5 — which is better for replacement?
INA126UA/2K5 is the stronger candidate for an exact replacement because it preserves the /2K5 gain ordering and is identified by Texas Instruments as the replacement for INA126PA. The INA126U/2K5 and INA126UA/2K5 use an 8-pin SOIC package, but package suffixes and ordering conventions still need confirmation. Compare the full ordering table to determine whether the UA version changes package, temperature grade, or other commercial attributes.
When should I choose INA126U/2K5 over INA122UA?
Choose the INA126U/2K5 when the design prioritizes the INA126 family’s micropower operation and precision instrumentation-amplifier performance. The INA122UA can be considered when its electrical ratings better match the measurement bandwidth, noise, gain, and supply requirements. Neither part should be selected from package shape alone; the input common-mode range, output swing, offset, drift, bandwidth, and gain-network requirements must be compared.
Is INA126U/2K5 suitable for battery-powered sensor measurement?
Yes. The INA126U/2K5 is suitable for battery-powered sensor measurement because its 175 µA quiescent current minimizes standby demand while the two-op-amp architecture provides differential signal conditioning. The 250 µV offset specification is useful for small sensor outputs. For an accurate design, also check input bias current, input common-mode range, noise, and the sensor source impedance over the intended temperature range.
What is the best cross-brand equivalent for INA126U/2K5?
No cross-brand drop-in equivalent can be confirmed from the available substitution records. One cross-reference result identifies an Analog Devices replacement without publishing a verifiable manufacturer MPN and complete pin-to-pin comparison in the supplied material. A candidate should not be approved until its exact MPN, SOIC-8 pinout, gain implementation, supply range, offset, noise, common-mode limits, and quiescent current have all been matched.

داده‌های مرجع مهندسی برای INA126U/2K5 — مقایسه، راهنمای طراحی و اطلاعات انطباق.

راهنمای انتخاب

Choose INA126U/2K5 for precision, low-level differential acquisition where low power, a 36 V maximum supply, and a two-op-amp instrumentation-amplifier architecture are important. It is especially suitable for portable sensor interfaces and industrial measurement nodes that can use the 175 µA-per-channel operating current. Prefer INA126UA/2K5 when reviewing a like-for-like TI ordering alternative because it preserves the /2K5 designation and is documented as the replacement for INA126PA. Consider INA128UA/2K5 only after confirming that its noise, bandwidth, common-mode range, and supply characteristics better match the signal chain. Consider INA122UA when its gain implementation and electrical performance offer a better fit. INA126U lacks the explicit /2K5 suffix and therefore requires closer review of the gain configuration. For any candidate, verify the 8-SOIC footprint, pin assignments, resistor network, reference voltage, input bias current, output swing, and operating-temperature range before releasing a production BOM.

مقایسه با جایگزین‌ها

پارامتر این محصول INA126UA/2K5 INA126U INA128UA/2K5 INA122UA
Package 8-SOIC 8-SOIC 8-SOIC 8-SOIC 8-SOIC
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Product Family INA126 micropower precision instrumentation amplifier INA126 INA126 INA128 INA122
Gain Ordering Code /2K5 /2K5 No /2K5 suffix /2K5 No /2K5 suffix

تفاوت‌های کلیدی

  • Closest documented same-family ordering option (در مقابلINA126UA/2K5)
  • Lower standby demand than the INA128 alternative (در مقابلINA128UA/2K5)
  • Exact gain-ordering retention versus unqualified INA126U (در مقابلINA126U)

یادداشت‌های طراحی

Place the INA126U/2K5 close to the differential source and keep the IN+ and IN− routes short and symmetric. High-impedance sensor nodes are sensitive to leakage from PCB contamination, so use a suitable board finish, guard the input nodes where appropriate, and avoid routing the input traces beside high-impedance or switching nodes. Follow the manufacturer application circuit for the gain resistors and reference connection.

Decouple the positive and negative supply pins locally, using the capacitance and placement shown in the Texas Instruments application circuit. The 175 µA quiescent current is beneficial for portable systems, but supply current still rises with output activity and load. Ensure that the selected supply mode keeps both input pins and the output inside their permitted common-mode and output-swing ranges.

Do not select a substitute from the SOIC-8 outline alone. INA126UA/2K5 retains the /2K5 ordering option and is the closest documented TI candidate, while INA128UA/2K5 and INA122UA belong to different families with different electrical characteristics. Confirm gain-network pins, reference behavior, input bias current, common-mode range, output swing, bandwidth, and supply limits before approving any replacement.

اطلاعات انطباق

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
بدون سرب
Unknown
بدون هالوژن
Unknown
مواد معدنی درگیری
Unknown

The available manufacturer and distributor pages do not provide explicit compliance values for the exact INA126U/2K5 ordering code. Compliance must be confirmed from the manufacturer product page or declaration associated with the selected lot.

جستجوهای مرتبط

ina126u datasheet INA126U/2K5 datasheet pdf INA126U/2K5 pinout INA126U/2K5 specifications INA126U/2K5 equivalent INA126U/2K5 replacement INA126U/2K5 cross reference INA126U/2K5 vs INA128UA/2K5 INA126U/2K5 price INA126U/2K5 stock Texas Instruments INA126U/2K5 INA126U/2K5 8-SOIC

قطعات و اصطلاحات مرتبط

Texas Instruments INA126U/2K5 INA126UA/2K5 INA126U INA128UA/2K5 INA122UA precision instrumentation amplifier differential signal acquisition two-op-amp architecture microPower input offset voltage quiescent current common-mode rejection gain network reference input sensor interface bridge transducer industrial process measurement battery-powered instrumentation 8-pin SOIC SOIC family surface mount semiconductor Texas Instruments INA126
استعلام قیمت سریع RFQ
جزئیات کامل را پر کنید — تیم فروش ما ظرف 24 ساعت پاسخ خواهد داد
شماره قطعه سازنده بسته‌بندی QTY قیمت هدف قیمت کل
✓
استعلام قیمت ارسال شد!

ظرف ۲۴ ساعت به ایمیل شما پاسخ خواهیم داد

1
درخواست قیمت ارسال شد
2
استعلام دریافت شد
3
سفارش ثبت شد
4
پرداخت
5
ارسال شد
6
تحویل داده شد
مشاهده جزئیات RFQ