INA2126E/250 - Dual 36V Micropower Instrumentation Amplifier
MPN: INA2126E/250 ✓ সক্রিয়INA2126E/250 সারাংশ
An instrumentation amplifier is a specialized analog amplifier that measures the voltage difference between two input signals while rejecting common-mode interference. The INA2126 family uses a two-op-amp architecture to provide differential input, high input impedance, and straightforward gain selection with an external resistor. Within the signal-chain hierarchy, it belongs to the instrumentation-amplifier class, amplifier IC category, analog signal-conditioning family, and broader semiconductor category.
The INA2126E/250 combines a 36 V supply range with low quiescent current, making it useful in portable instrumentation, battery-powered measurement systems, and industrial data-acquisition equipment. Its two amplifier channels can acquire independent differential signals, while the differential topology helps suppress common-mode voltage present on both inputs. Gain is established with an external resistor, allowing the circuit designer to select the required signal gain without changing the internal amplifier architecture.
According to the Texas Instruments INAx126 family datasheet, the device uses a two-op-amp design and consumes 175 µA per channel. The low input bias current and high input impedance help prevent the source sensor from being heavily loaded. This is particularly important for high-impedance transducers, resistive sensors, and bridge-based measurements where input loading can otherwise change the detected voltage and degrade accuracy.
Typical uses include low-voltage current sensing, portable medical instrumentation, industrial pressure and temperature acquisition, sensor-interface circuits, and precision differential measurement systems. The dual-channel configuration is useful when a design must monitor two related signals, such as a differential sensor output and a reference or diagnostic channel, while preserving independent gain-setting resistors for each amplifier.
For stable operation, place supply-decoupling capacitors close to the supply pins and route each differential input as a compact pair to minimize noise pickup. Select the external gain resistor with suitable tolerance and low temperature coefficient, verify input and output common-mode limits at the intended supply voltage, and ensure the reference pin is driven with a low-impedance source when a nonzero midpoint voltage is required.
This product page consolidates the device function, operating limits, package information, sourcing paths, drop-in family alternatives, comparison parameters, and practical circuit-design guidance. It supports faster engineering selection by connecting the INA2126E/250’s low-power precision characteristics with the signal-chain requirements of portable instrumentation and low-level differential-sensor designs.
এর জন্য ড্রপ-ইন বিকল্প INA2126E/250 — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।
INA2126EA/2K5G4
✅ ড্রপ-ইন📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)
INA2126UA/2K5E4
✅ ড্রপ-ইন📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)
INA2126UAG4
✅ ড্রপ-ইন📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)
INA2126E/250 সর্বোচ্চ রেটিং ও বৈদ্যুতিক বৈশিষ্ট্য
| Amplifier Type | Dual precision instrumentation amplifier |
| Number of Channels | 2 channels |
| Maximum Supply Voltage | 36 V |
| Supply Voltage Range | ±1.35 V to ±18 V |
| কুইসেন্ট কারেন্ট | 175 µA per channel |
| Offset Voltage | 250 µV maximum |
| Internal Architecture | Two-op-amp instrumentation amplifier |
| Gain | Set by an external resistor |
| Input Type | Differential |
| প্যাকেজ | 16-pin SSOP (DBQ) |
| মাউন্টিং টাইপ | Surface mount |
INA2126E/250 16-pin ssop (dbq) পিন কনফিগারেশন গাইড
INA2126E/250 (16-pin ssop (dbq) প্যাকেজ)-এর পিন কনফিগারেশন। এই অ্যানালগ কম্পোনেন্টে ইনপুট, আউটপুট ও পাওয়ার সাপ্লাই পিন রয়েছে। অফসেট নাল, কম্পেনসেশন ও এনেবল পিন কনফিগারেশনের জন্য প্রস্তুতকারকের ডেটাশিট দেখুন। সিগন্যাল কন্ডিশনিং ও অ্যামপ্লিফায়ার সার্কিটের জন্য আদর্শ।
এর জন্য বিস্তারিত পিনআউট ডেটা পাওয়া যায়নি INA2126E/250.
দেখুন ডেটাশিট সম্পূর্ণ পিন কনফিগারেশনের জন্য।
সাধারণ ব্যবহার
INA2126E/250 এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: Portable Differential Sensor Acquisition, Industrial Current-Sense Measurement, Medical Signal Conditioning, Bridge-Based Pressure Measurement, Precision Test and Measurement, Two-Channel Data Acquisition.
Portable Differential Sensor Acquisition
The INA2126E/250 fits portable instrumentation because its 175 µA per-channel quiescent current reduces the power burden of two continuously active measurement channels. Each channel can acquire a differential sensor signal while rejecting common-mode voltage present on both inputs. The 250 µV maximum offset is particularly useful when the measured differential level is small, because it limits the input-referred error before amplification. Install the device close to the sensor connector, use short differential traces, and select the external gain resistor according to the INAx126 gain table. Battery life remains dependent on the sensor itself, so power-saving control of the amplifier system can provide a larger system-level improvement.
সুপারিশকৃত
Industrial Current-Sense Measurement
The INA2126E/250 is appropriate for industrial current measurement when the shunt differential voltage must be amplified in the presence of a larger common-mode potential. Its differential input architecture reduces sensitivity to voltage shared by both sense nodes, while the dual-channel arrangement allows a second channel to monitor a complementary measurement or diagnostic signal. The 36 V maximum supply rating supports instrumentation operating above conventional ±5 V rails, although the actual input common-mode and output-swing limits must be respected. Place the amplifier across the shunt Kelvin connections and avoid sharing high-current paths with sensitive input traces to prevent voltage drops from appearing as measurement error.
সুপারিশকৃত
Medical Signal Conditioning
The INA2126E/250 can condition low-level differential signals in portable medical equipment when both low power and precision are design priorities. Its 250 µV maximum offset helps preserve accuracy at small input levels, while the dual configuration can process a measurement channel and a reference or auxiliary channel. The two-op-amp instrumentation-amplifier topology provides high input impedance and common-mode rejection without requiring the system to match a discrete op-amp network. Designers must still verify electrode-generated input levels, input protection, isolation requirements, leakage behavior, and applicable medical-system standards. The amplifier should be paired with suitable protection and acquisition circuitry rather than treated as a complete medical front end.
সুপারিশকৃত
Bridge-Based Pressure Measurement
The INA2126E/250 is well matched to resistive bridge sensing because the differential input can receive the bridge excitation voltage while subtracting the common reference present on both bridge nodes. With 175 µA per channel, it adds low quiescent demand to a portable pressure or force-monitoring system, and the 250 µV maximum offset limits a significant source of low-level measurement error. Select the gain to maximize the bridge differential output within the amplifier’s output-swing limits. Place the amplifier near the bridge connections, maintain symmetric routing, and provide local supply bypassing to prevent excitation and digital activity from adding noise to the small differential result.
সুপারিশকৃত
Precision Test and Measurement
The INA2126E/250 can serve as the analog front end of a compact precision measurement instrument, especially when two low-level differential channels must be handled without continuous high power consumption. Its instrumentation-amplifier configuration reduces common-mode error and simplifies gain implementation to one external resistor per channel. A system can apply the measured signal to a high-resolution converter while using the second channel for reference, calibration, or diagnostic information. For laboratory-grade accuracy, verify resistor tolerance, input bias-current effects, source impedance, frequency response, and output settling. The combination of low offset and low quiescent current supports battery-powered field instruments as well as fixed test equipment.
সুপারিশকৃত
Two-Channel Data Acquisition
The INA2126E/250 provides two independent precision instrumentation-amplifier channels in one 16-pin SSOP, making it useful for compact two-channel data-acquisition systems. Both channels share the same family-level low-noise, low-quiescent-current characteristics while allowing separate external gain resistors. This supports measurement of a primary differential sensor and a secondary reference, diagnostic, or complementary sensor without using two discrete amplifier packages. The 36 V maximum supply provides headroom for industrial signal levels, but each channel must remain within its own common-mode and output-swing limits. Routing each differential pair symmetrically and decoupling the supplies close to the device helps preserve the benefit of the instrumentation-amplifier topology.
সুপারিশকৃত
সুপারিশকৃত পণ্যের সারসংক্ষেপ
এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা INA2126E/250 — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।
নির্বাচন গাইড
বিকল্পের সাথে তুলনা
| পারামিটার | এই পণ্য | INA2126EA/2K5G4 | INA2126UA/2K5E4 | INA2126UAG4 |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | SSOP-16 | SSOP-16 | SSOP-16 | SSOP-16 |
| Amplifier Configuration | Dual instrumentation amplifier | Dual instrumentation amplifier | Dual instrumentation amplifier | Dual instrumentation amplifier |
| Internal Architecture | Two-op-amp architecture | Two-op-amp INA2126 family architecture | Two-op-amp INA2126 family architecture | Two-op-amp INA2126 family architecture |
| Gain Configuration | External resistor | External resistor | External resistor | External resistor |
| Special Ordering Information | INA2126E/250 orderable code | INA2126EA/2K5G4 orderable code | INA2126UA/2K5E4 orderable code | INA2126UAG4 orderable code |
মূল পার্থক্যসমূহ
- Dual precision channels in one 16-pin SSOP (বনামINA2126UA/2K5E4)
- Low 175 µA per-channel quiescent current (বনামINA2126EA/2K5G4)
- 36 V maximum supply with 250 µV maximum offset (বনামINA2126UAG4)
ডিজাইন নোট
Route each differential input as a closely coupled pair from the source or connector to the amplifier. Keep the pair short, avoid crossing unrelated high-current or switching paths, and establish a nearby ground reference. Symmetrical routing limits conversion of common-mode noise into differential error and preserves the common-mode rejection advantage of the instrumentation-amplifier topology.
Place the supply-bypass capacitor immediately beside the device supply pins and connect it with the shortest practical traces. The INA2126E/250 supports operation from ±1.35 V to ±18 V, but the selected supply must also satisfy the input common-mode range and output-swing requirements. Account for supply ripple, startup behavior, and the 175 µA per-channel quiescent current when sizing the power budget.
Do not assume that identical package names guarantee identical function. Orderable-code differences can encode gain, temperature grade, or production configuration. Before replacing INA2126E/250 with INA2126EA/2K5G4, INA2126UA/2K5E4, or INA2126UAG4, compare the exact gain setting, electrical limits, temperature grade, pin functions, and marking in the manufacturer datasheet.
Use a low-tolerance, low-temperature-coefficient external gain resistor when measurement accuracy depends on gain stability. Evaluate the gain resistor’s contribution to noise and drift, maintain a consistent layout for both channels when they measure related signals, and treat the reference connection as a sensitive node. Any nonzero reference voltage should be generated by a low-impedance source and adequately decoupled.
কমপ্লায়েন্স তথ্য
The retrieved INA2126 product records do not explicitly state the target orderable part’s compliance status. Confirm current quality and environmental documentation with Texas Instruments.