KSZ8041MLLI-TR - 10/100 Ethernet PHY | Microchip Technology
MPN: KSZ8041MLLI-TR ✓ সক্রিয়KSZ8041MLLI-TR সারাংশ
An Ethernet physical-layer transceiver, commonly called an Ethernet PHY, converts digital MAC-layer data into signals suitable for twisted-pair cabling and reconstructs receive signals for the MAC controller. Within the network hierarchy, the KSZ8041 belongs to the PHY layer of an Ethernet interface: the PHY connects a digital bus such as MII, RMII, or SMII to analog 10BASE-T or 100BASE-TX line drivers and receivers. This separation allows a network controller or processor to manage traffic while the PHY handles cable-level signaling and link negotiation.
Key features include support for 10 Mb/s and 100 Mb/s operation, IEEE 802.3u auto-negotiation, and the broadcast PHY address 0 defined by the IEEE 802.3 specification. Auto-negotiation can be enabled through hardware pin strapping on pin 42 or through register 0, bit 12. The broadcast address allows a management system to read from or write to one device, or write to multiple KSZ8041 devices simultaneously, which is useful in managed network equipment.
The KSZ8041 uses a mixed-signal architecture designed to improve signaling distance and reduce power consumption. Its digital management interface includes MDC and MDIO, while interrupt signaling supports connection monitoring. The manufacturer hardware design checklist specifies a 4.7 kOhm pull-up on MDIO pin 18 when MDC/MDIO management is used. It also specifies a 4.7 kOhm external pull-up on INTRP pin 21 because that output is open-drain. These details are important when creating a new PCB because the management bus must operate at valid logic levels even before firmware configures the device.
Typical applications include industrial automation equipment, embedded network bridges, print servers, set-top and access equipment, and embedded systems that require 10/100 Ethernet connectivity over copper twisted-pair media. The Full MII interface is especially useful for designs requiring the complete parallel media-independent interface rather than the reduced pin count of RMII. For a new compact design, however, the smaller KSZ8041NLI-TR in a 32-QFN package may be easier to route when RMII operation is sufficient.
PCB implementation should follow the manufacturer's KSZ8041MLL Hardware Design Checklist and data sheet, particularly for magnetic-component selection, supply decoupling, RJ-45 integration, crystal or clock requirements, and management-interface pull-ups. Keep the digital interface and analog network section appropriately partitioned, provide a low-impedance ground return, and observe the required high-speed layout practices around the PHY and magnetics. The 48-LQFP package also requires adequate thermal spreading on denser boards where sustained line activity increases power dissipation.
এর জন্য ড্রপ-ইন বিকল্প KSZ8041MLLI-TR — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।
এই পণ্যের জন্য কোনো ড্রপ-ইন বিকল্প পাওয়া যায়নি।
বিকল্প অনুরোধ করুনKSZ8041MLLI-TR বিশেষণ
| Product Type | 10BASE-T/100BASE-TX Ethernet physical-layer transceiver |
| Supported Data Rates | 10 Mb/s and 100 Mb/s |
| Digital Interface | MII, RMII, and SMII |
| Target MPN Interface Configuration | Full MII |
| Receiver/Transmitter Count | 1 receiver and 1 transmitter |
| Supply Architecture | Single supply |
| Cable Standard | IEEE 802.3 10BASE-T and 100BASE-TX |
| Auto-Negotiation | Enabled by pin 42 hardware strapping or register 0, bit 12 |
| Broadcast PHY Address | PHY address 0 |
| Crossover Handling | HP Auto MDI/MDI-X |
| প্যাকেজ | 48-LQFP, 7 x 7 mm |
| Package Type | Surface-mount LQFP |
| MDIO Pull-Up Requirement | 4.7 kOhm on pin 18 when MDC/MDIO management is used |
| INTRP Pull-Up Requirement | 4.7 kOhm on pin 21 for the open-drain output |
KSZ8041MLLI-TR surface-mount lqfp পিন কনফিগারেশন গাইড
KSZ8041MLLI-TR (surface-mount lqfp প্যাকেজ)-এর পিন কনফিগারেশন। পিন নম্বরিং, ফাংশন এবং সংযোগ ডায়াগ্রাম প্রস্তুতকারকের ডেটাশিটে সংজ্ঞায়িত করা আছে। সঠিক ফুটপ্রিন্ট এবং সোল্ডারিং নির্দেশিকার জন্য এটি দেখুন।
এর জন্য বিস্তারিত পিনআউট ডেটা পাওয়া যায়নি KSZ8041MLLI-TR.
দেখুন ডেটাশিট সম্পূর্ণ পিন কনফিগারেশনের জন্য।
সাধারণ ব্যবহার
KSZ8041MLLI-TR এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: Industrial Ethernet Controllers, Embedded Network Bridges, Network Access Equipment, Set-Top and Media Devices, Managed Network Interfaces, Secure Network Endpoints.
Industrial Ethernet Controllers
The KSZ8041MLLI-TR is suitable for industrial controllers that need a dedicated 10/100 Mb/s Ethernet front end. Its Full MII interface provides a broad parallel data path, while auto-negotiation through pin 42 or register 0, bit 12 lets the controller operate with either 10BASE-T or 100BASE-TX link partners. The mixed-signal design also targets reduced power consumption and extended signaling distance. In an industrial design, preserve the separation between digital circuitry and the Ethernet magnetics section, and use the manufacturer's 4.7 kOhm MDIO and INTRP pull-up guidance.
সুপারিশকৃত
Embedded Network Bridges
Embedded bridges and protocol-conversion products can use the KSZ8041MLLI-TR as the copper-Ethernet endpoint for a host processor or communications controller. The 48-LQFP package exposes the Full MII interface and offers enough board space for controlled routing of the parallel bus. IEEE 802.3u auto-negotiation removes the need for manual speed selection, while HP Auto MDI/MDI-X simplifies connections using either straight-through or crossover cabling. Firmware should confirm negotiated speed, link status, and PHY address assignment during startup.
সুপারিশকৃত
Network Access Equipment
Access terminals and network interface modules can employ the KSZ8041MLLI-TR for a 10/100 Mb/s copper port. The broadcast PHY address 0 provides a useful management path for reading from or writing to a single PHY, or writing simultaneously to multiple KSZ8041 devices. Its HP Auto MDI/MDI-X support simplifies field cabling, and the auto-negotiation implementation selects the highest common mode with the connected equipment. Designers should follow the manufacturer data sheet when arranging the isolated network interface, magnetics, and supply-return path.
সুপারিশকৃত
Set-Top and Media Devices
The KSZ8041MLLI-TR can provide a network connection in set-top boxes, media appliances, and other products that exchange data over 10BASE-T or 100BASE-TX Ethernet. The Full MII interface supports a conventional parallel MAC connection, while software-controlled auto-negotiation allows firmware to adapt to the available link speed. Its single-supply mixed-signal implementation is intended to reduce power use compared with more demanding interface arrangements. Product teams should budget board area for the 48-LQFP device and its supporting magnetics while maintaining the required layout geometry.
সুপারিশকৃত
Managed Network Interfaces
Managed network interfaces benefit from the KSZ8041MLLI-TR's support for broadcast PHY address 0 and MDC/MDIO management. A controller can use the management bus to configure or monitor PHY behavior, including the register-controlled auto-negotiation path in register 0, bit 12. The MDIO signal on pin 18 requires a 4.7 kOhm pull-up when the management interface is active, and the open-drain INTRP output on pin 21 requires a 4.7 kOhm external pull-up. These details should be incorporated into the bus topology and reset sequencing early in the schematic design.
সুপারিশকৃত
Secure Network Endpoints
Networked monitoring and security endpoints can use the KSZ8041MLLI-TR to add 10/100 Mb/s Ethernet connectivity to an embedded controller. Automatic crossover handling reduces cabling configuration errors in deployed equipment, while auto-negotiation supports operation across mixed 10 Mb/s and 100 Mb/s environments. The device's broadcast management capability can assist multi-PHY system administration. Designers should isolate the network-media section, follow the manufacturer hardware design checklist, and verify system EMC and security requirements alongside the electrical interface design.
সুপারিশকৃত
সুপারিশকৃত পণ্যের সারসংক্ষেপ
এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা KSZ8041MLLI-TR — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।
নির্বাচন গাইড
বিকল্পের সাথে তুলনা
| পারামিটার | এই পণ্য |
|---|---|
| Brand | Microchip Technology |
| Package | 48-LQFP, 7 x 7 mm |
| Supported Ethernet Rates | 10 Mb/s and 100 Mb/s |
| Digital Interfaces | MII, RMII, and SMII |
| Target Ordering Configuration | Full MII |
| Supply Architecture | Single supply |
| Auto-Negotiation | IEEE 802.3u |
| Crossover Handling | HP Auto MDI/MDI-X |
| Broadcast PHY Address | PHY address 0 |
| Management Pull-Up | 4.7 kOhm on MDIO pin 18 |
| Interrupt Pull-Up | 4.7 kOhm on INTRP pin 21 |
| Mounting Type | Surface mount |
মূল পার্থক্যসমূহ
- Full MII configuration in a 48-LQFP package (বনামKSZ8041NLI-TR)
- Flexible auto-negotiation activation (বনামKSZ8041NLI-TR)
- Management support for multi-PHY equipment (বনামKSZ8041NLI-TR)
ডিজাইন নোট
Follow the manufacturer KSZ8041MLL Hardware Design Checklist for the 48-LQFP placement, magnetics, clock, supply, and network-interface layout. Keep the Full MII digital bus compact and route it away from the analog network section. Preserve the specified component clearances and copper geometry around the PHY and magnetics because these constraints support reliable 100BASE-TX operation and reduce sensitivity to external interference.
Design the single-supply rail around the manufacturer's specified operating limits, which are listed as [DATA_NEEDED: supply voltage range]. Place the required supply-decoupling network close to the relevant power pins and provide a quiet return path for the digital and analog sections. Validate startup, reset, and link-up behavior across the complete supported input-voltage range rather than assuming a nominal supply is sufficient.
Do not omit the external pull-ups required by the manufacturer's hardware design checklist: use 4.7 kOhm on MDIO pin 18 when the management bus is used and 4.7 kOhm on open-drain INTRP pin 21. Also avoid treating the KSZ8041NLI-TR as a direct substitute because it uses a 32-QFN package. Validate auto-negotiation configuration, the pin-42 strap, and the MDIO/MDC address arrangement before releasing firmware.
কমপ্লায়েন্স তথ্য
The manufacturer data sheet identifies IEEE 802.3 and IEEE 802.3u networking requirements. RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals statuses were not stated in the available product information and are therefore recorded as unknown.