Texas Instruments

OPA196ID - 36V Rail-to-Rail Operational Amplifier | TI

MPN: OPA196ID ✓ সক্রিয়
36 V Vdss 8-pin SOIC Package
সর্বনিম্ন অর্ডার পরিমাণ: 1 |

OPA196ID সারাংশ

The Texas Instruments OPA196ID is a single, 36 V, low-power, rail-to-rail operational amplifier with mux-friendly inputs, housed in an 8-pin SOIC package. It is designed for general-purpose precision signal-conditioning applications that require operation from a wide supply-voltage range and rail-to-rail input and output capability. The OPA196ID is suitable for instrumentation, sensor interfaces, industrial control, test equipment, and audio or communications signal paths.

An operational amplifier is an integrated circuit that amplifies the difference between two input voltages. It is a fundamental building block in analog electronics, within the broader hierarchy of semiconductor devices and signal-conditioning ICs. Rail-to-rail input capability allows the amplifier to operate across nearly the complete input-voltage range of the supply, while rail-to-rail output capability helps preserve signal swing near the supply rails. Mux-friendly inputs are useful when multiple signals must be connected to an amplifier through switching or multiplexing networks.

The OPA196ID is identified by Texas Instruments as a 36 V, low-power, all-purpose amplifier. Its rail-to-rail architecture and low-voltage operation make it appropriate for systems powered from industrial supplies, split analog rails, laboratory instrumentation, and higher-voltage sensor interfaces. The single-amplifier configuration in an 8-pin SOIC package also simplifies board design when one signal path is sufficient and a compact, standard surface-mount footprint is preferred.

The OPAx196 family includes the OPA196 single amplifier, OPA2196 dual amplifier, and OPA4196 quad amplifier. The OPA196ID is the single-amplifier SOIC-8 orderable variant. Its 36 V supply rating provides additional headroom for applications whose signal amplitudes exceed the range of common low-voltage amplifiers, while its general-purpose positioning allows it to be used for both low- and higher-voltage analog signal chains.

Typical uses include precision current sensing, buffer and driver stages, sensor amplification, data acquisition, industrial process control, and low-frequency communications equipment. When using the device, verify common-mode range, output swing, input bias current, noise, and stability requirements for the selected gain and load against the manufacturer datasheet.

For a replacement or second-source decision, confirm the exact package, pin arrangement, supply rating, offset voltage, bandwidth, slew rate, input bias current, noise, output-current capability, and operating-temperature requirements. This page focuses on the OPA196ID single-amplifier 8-pin SOIC version and separates manufacturer-supported information from parameters that require design-level verification.

এর জন্য ড্রপ-ইন বিকল্প OPA196ID — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।

এই সিরিজের ভ্যারিয়েন্ট

একই সিরিজের মডেল যেগুলো drop-in compatible OPA196ID (একই form factor এবং footprint) — পার্থক্য রয়েছে Product Type.

Texas Instruments
Product Type: Precision operational amplifier
এর সাথে তুলনা করুন OPA196ID →

OPA197IDR

✅ ড্রপ-ইন
📦 SOIC-8
Different precision-amplifier family; offset, noise, bandwidth, slew-rate, and bias-current characteristics require direct datasheet comparison

📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)

OPA196ID সর্বোচ্চ রেটিং ও বৈদ্যুতিক বৈশিষ্ট্য

Product Type Single operational amplifier
Manufacturer Texas Instruments
সাপ্লাই ভোল্টেজ 36 V
Architecture Rail-to-rail input and output
Input Type Mux-friendly input
Number of Circuits 1
প্যাকেজ 8-pin SOIC
মাউন্টিং টাইপ Surface mount
Operating Class General-purpose amplifier

OPA196ID 8-pin soic পিন কনফিগারেশন গাইড

OPA196ID (8-pin soic প্যাকেজ)-এর পিন কনফিগারেশন। এই অ্যানালগ কম্পোনেন্টে ইনপুট, আউটপুট ও পাওয়ার সাপ্লাই পিন রয়েছে। অফসেট নাল, কম্পেনসেশন ও এনেবল পিন কনফিগারেশনের জন্য প্রস্তুতকারকের ডেটাশিট দেখুন। সিগন্যাল কন্ডিশনিং ও অ্যামপ্লিফায়ার সার্কিটের জন্য আদর্শ।

OPA196ID-এর জন্য 8-pin soic প্যাকেজ পিনআউট ডায়াগ্রাম

এর জন্য বিস্তারিত পিনআউট ডেটা পাওয়া যায়নি OPA196ID.

দেখুন ডেটাশিট সম্পূর্ণ পিন কনফিগারেশনের জন্য।

সাধারণ ব্যবহার

OPA196ID এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: Industrial Sensor Signal Conditioning, Data Acquisition Front End, Precision Current and Voltage Measurement, Test and Measurement Instrumentation, Communications and Audio Buffering, Muxed Multichannel Measurement System.

🏭

Industrial Sensor Signal Conditioning

OPA196ID is appropriate for amplifying low-level sensor signals when the design operates from a relatively high-voltage analog rail. Its 36 V supply classification and rail-to-rail input and output architecture provide useful headroom for sensors whose output range approaches the supply limits. Place the amplifier in an inverting or non-inverting topology, keep the feedback network close to the device, and verify the actual common-mode range, input offset, noise, and output swing in the OPAx196 datasheet. The mux-friendly input architecture can also be useful when several sensor signals are routed through a multiplexer before amplification.

🖥️

Data Acquisition Front End

OPA196ID can serve as the analog gain stage immediately before an ADC or data-conversion system. Its 36 V operating class and rail-to-rail behavior are useful in measurement equipment that accepts signals above the common range of low-voltage amplifiers, while the single-amplifier package leaves board space for additional channels. Design the feedback ratio around the required gain and bandwidth, confirm the output swing at the selected load, and check whether the amplifier's noise and offset meet the acquisition budget. A unity-gain buffer configuration is also possible when the source impedance and settling requirements permit it.

⚡

Precision Current and Voltage Measurement

OPA196ID is suitable for precision current or voltage measurement paths where the sensed signal must be amplified accurately within a wider-voltage system. The 36 V supply rating helps isolate the amplifier from the high-voltage portion of the circuit, while rail-to-rail operation can improve signal utilization when the input remains within the specified common-mode limits. In current-shunt measurements, pay particular attention to input offset voltage, bias current, noise, and the voltage drop across the shunt. For high-voltage front ends, add appropriate protection and isolation before applying the signal to the amplifier.

🔧

Test and Measurement Instrumentation

OPA196ID can be used in general-purpose laboratory and test instrumentation where a single precision amplifier must operate across a broader voltage range than conventional 5 V devices. Its rail-to-rail input and output characteristics are valuable for conditioning bipolar or near-rail signals, and the 8-pin SOIC package is convenient for compact analog boards. The design must account for the amplifier's actual input and output limits, offset drift, noise, bandwidth, and output-current capability. Stable feedback-network layout and short feedback traces are important when the circuit operates at higher gain or drives resistive and capacitive loads.

🌐

Communications and Audio Buffering

OPA196ID is suitable for buffering or modest gain stages in communications and audio equipment where low-level analog signals require amplification before conversion or transmission. Rail-to-rail operation can preserve dynamic range in single-supply designs, while the 36 V rating supports higher-voltage analog sections. The actual signal bandwidth and distortion must be checked against the OPAx196 datasheet, especially when the amplifier drives a cable, transformer, or capacitive load. Use short, direct routing for the input and feedback components and place any required output isolation resistor close to the amplifier to reduce unwanted capacitive feedback.

🧩

Muxed Multichannel Measurement System

OPA196ID is a logical candidate for a multiplexed measurement system because Texas Instruments specifically identifies its inputs as mux-friendly. Multiple sensor or test channels can be selected by an analog multiplexer and then amplified by the OPA196ID, reducing the number of separate amplifier packages while preserving a high-voltage-capable analog front end. Confirm that the multiplexer output remains within the amplifier's common-mode range and that source impedance does not create unacceptable settling behavior. The acquisition cycle must also allow the amplifier to settle to the required accuracy before the converted value is accepted.

What is the OPA196ID?
The OPA196ID is a Texas Instruments single operational amplifier with a 36 V maximum supply rating, rail-to-rail input and output operation, and mux-friendly inputs in an 8-pin SOIC package. According to the Texas Instruments OPA196 product page and OPAx196 datasheet, it is positioned as a low-power, general-purpose amplifier for precision signal-conditioning applications. The single-amplifier configuration allows one analog signal path per package, while the 36 V rating provides useful headroom for industrial and instrumentation systems.
What is the operating voltage range of OPA196ID?
The OPA196ID is identified as a 36 V operational amplifier, with rail-to-rail operation extending input and output capability toward the supply rails. The exact minimum and maximum operating supply limits, along with common-mode and output-swing details, should be taken from the OPAx196 manufacturer datasheet for the specific temperature range and operating conditions. The 36 V classification makes the device more suitable for higher-voltage analog environments than basic 5 V or 3.3 V amplifiers.
Is OPA196ID rail-to-rail?
Yes. The OPA196ID is described by Texas Instruments as a rail-to-rail operational amplifier, covering both rail-to-rail input and output behavior. This means the device can accept input signals close to the supply rails and can produce output voltages closer to the rails than a non-rail-to-rail amplifier. Actual usable swing depends on load current, supply voltage, and temperature, so verify the output-voltage limits in the manufacturer datasheet before designing a saturated output condition.
Where can I download the OPA196ID datasheet PDF?
The official OPA196 datasheet PDF is available at https://www.ti.com/lit/ds/symlink/opa196.pdf. It covers the OPAx196 family, including the OPA196 single amplifier, and provides the authoritative information for ordering codes, electrical characteristics, pin descriptions, application details, and test conditions. Use the ordering-information section to confirm that OPA196ID refers to the 8-pin SOIC variant rather than the dual or quad family members.
What is the OPA196ID pinout?
The OPA196ID uses an 8-pin SOIC package, but the complete numbered pin description is not reproduced in the available product snippets. Use the pin-description table in the Texas Instruments OPAx196 datasheet to assign input, output, supply, and no-connect pins before PCB routing or schematic capture. The SOIC-8 footprint is not sufficient by itself to guarantee correct polarity or function, particularly when a dual or quad amplifier is being considered as an alternative.
Where can I buy OPA196ID online?
Use the Request a Quote form on this page to request OPA196ID availability, unit pricing, and lead time from XAIPART. The manufacturer lists OPA196ID as a standard single, 8-pin SOIC operational amplifier, but current stock and shipment timing can vary by order quantity. Request the exact OPA196ID order code, required quantity, target date, and packaging preference with the quotation request.
What is the price of OPA196ID?
The current OPA196ID unit price is generated through XAIPART's quotation process rather than being fixed in this technical description. Use the Request a Quote form on this page and provide quantity, delivery location, and target date for a current quotation. The listed historical reference price is retained separately for sourcing context, while the quotation form should be used for an actionable commercial offer.
What is the lead time for OPA196ID?
Current OPA196ID lead time depends on order quantity, packaging, and supply status, so it should be confirmed through the Request a Quote form on this page. The product is identified by Texas Instruments as an active single operational amplifier in the 8-pin SOIC package. Include your required quantity and production schedule in the request so that allocation and delivery timing can be reviewed against the actual order.
Is OPA196ID in stock?
Stock for OPA196ID should be confirmed through the Request a Quote form on this page rather than inferred from a distributor search result. The manufacturer product page identifies the device as an OPA196 single, 36 V, low-power, rail-to-rail amplifier, while availability can change by package, quantity, and order date. Submit the exact OPA196ID quantity and target shipment date for a current availability response.
OPA196ID vs OPA197IDR - which is better for precision sensing?
OPA196ID and OPA197IDR are not automatically interchangeable because they are different amplifier families with potentially different offset, noise, bandwidth, and stability specifications. OPA197IDR appears in the component cross-reference search, but the manufacturer OPA196 and OPA197 datasheets should be compared directly before substitution. Use the OPA196ID when its documented specifications meet the design; select OPA197IDR only after verifying its electrical limits, pinout, package, and application requirements.
What is the difference between OPA196ID and OPA191?
OPA196ID and OPA191 are related Texas Instruments single operational amplifiers, but the correct choice depends on the specific gain, bandwidth, offset, noise, supply, and input-range requirements. Texas Instruments lists OPA196 as a 36 V, low-power, all-purpose amplifier with mux-friendly inputs. The OPA191 should be selected only after its manufacturer datasheet confirms that its electrical characteristics and 8-pin package satisfy the target design.
When should I choose OPA196ID over OPA191?
Choose OPA196ID when the design benefits from the OPA196 family's stated 36 V, low-power, rail-to-rail, mux-friendly characteristics and its 8-pin SOIC implementation. Choose OPA191 when its documented parameters provide a better fit for the required gain, speed, offset, noise, or precision. Because the two parts are not proven identical by the available cross-reference information, make the decision from the manufacturer datasheets and application conditions.
Is OPA196ID suitable for industrial sensor interfaces?
OPA196ID can be suitable for industrial sensor interfaces when the sensor signals, supply rails, common-mode range, noise, offset, and output requirements fall within its specified operating limits. Its 36 V supply rating and mux-friendly inputs are useful for higher-voltage and multiplexed measurement systems. Confirm the maximum input and output excursions, input protection needs, settling behavior, and thermal conditions in the OPAx196 datasheet.
What is the best drop-in replacement for OPA196ID?
The OPA197IDR is a candidate appearing in the component cross-reference results, but it should be treated as a lead rather than a guaranteed drop-in replacement. A true drop-in replacement must match the 8-pin SOIC footprint, pin functions, supply range, common-mode range, output swing, offset, noise, bandwidth, slew rate, bias current, and load capability. Validate the candidate against both manufacturer datasheets before approving it for a production PCB.
Can OPA197IDR replace OPA196ID?
OPA197IDR may be considered as a replacement candidate, but the available information does not establish exact pin-to-pin and parametric equivalence. OPA197IDR is a different amplifier family from OPA196ID, so offset voltage, noise, bandwidth, slew rate, input bias current, common-mode behavior, and output drive may differ. Review the official OPA196 and OPA197 datasheets, then confirm stability and accuracy in the target circuit before substitution.
What are the key specifications of OPA196ID that engineers should know?
The key OPA196ID specifications are its single-amplifier configuration, 36 V supply rating, rail-to-rail input and output operation, mux-friendly inputs, and 8-pin SOIC package. Texas Instruments describes the OPA196 as a low-power, general-purpose amplifier within the OPAx196 family. Exact offset voltage, gain-bandwidth product, slew rate, noise, bias current, common-mode limits, output swing, quiescent current, and temperature range must be taken from the manufacturer datasheet for final design calculations.

এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা OPA196ID — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।

নির্বাচন গাইড

Choose the OPA196ID when the application needs a single, low-power, general-purpose amplifier with a 36 V supply classification, rail-to-rail input and output behavior, and mux-friendly inputs. It is particularly appropriate for industrial measurement, instrumentation, higher-voltage analog signal conditioning, and post-mux amplification where the signal remains within the documented operating limits. Consider OPA197IDR only after comparing its official datasheet against the OPA196 for offset, noise, bandwidth, slew rate, bias current, input range, output drive, and stability. Use a broader family member such as a dual or quad amplifier only when the board design changes and the circuit is no longer a strict single-amplifier drop-in. The final selection should also include package footprint, thermal conditions, sourcing lifecycle, and validated application-circuit behavior.

বিকল্পের সাথে তুলনা

পারামিটার এই পণ্য OPA197IDR
Brand Texas Instruments Texas Instruments
Package 8-pin SOIC SOIC-8

মূল পার্থক্যসমূহ

  • Higher supply-voltage class (বনামOPA197IDR)
  • Mux-friendly input architecture (বনামOPA197IDR)
  • General-purpose 36 V rail-to-rail operation (বনামOPA197IDR)

ডিজাইন নোট

The OPA196ID is rated for a 36 V supply class, but the complete minimum and maximum operating supply limits must be checked in the manufacturer datasheet for the selected temperature grade. Derating the circuit for transient supply excursions, motor buses, and hot-plug events is important because the absolute maximum ratings are not operating targets. Confirm that the signal source, input protection network, and feedback components remain within their own voltage ratings.

Route the non-inverting input, feedback components, and ground return using short paths, and keep the feedback network close to the amplifier. For a precision circuit, use a continuous ground plane rather than a split plane unless the system architecture specifically requires isolation. Place input protection components close to the connector and keep their capacitance and leakage consistent with the required source impedance and bandwidth.

Do not assume that a 36 V amplifier automatically accepts any signal between the supply rails. Verify the OPA196ID common-mode input range, output swing, input protection behavior, and stability with the intended load. Rail-to-rail operation also has transition regions and load-dependent limits, so use the manufacturer data for the exact operating condition. When replacing OPA196ID with OPA197IDR, compare those same electrical limits rather than relying on the shared SOIC-8 outline.

For high-gain or wide-bandwidth signal-conditioning stages, minimize parasitic capacitance around the input and feedback nodes and use appropriately shielded or guarded routing for very high-impedance sources. The mux-friendly input characteristic does not remove the need to control source impedance and settling time. Check acquisition timing against the amplifier's small-signal and large-signal behavior before using the OPA196ID behind a multiplexer.

কমপ্লায়েন্স তথ্য

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
লিড ফ্রি
Unknown
হ্যালোজেন ফ্রি
Unknown
কনফ্লিক্ট মিনারেলস
Unknown

The available manufacturer snippets identify the OPA196 as a 36 V, low-power, rail-to-rail amplifier but do not explicitly state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. Confirm these attributes on the current manufacturer product page or product declaration.

ডেটা যাচাই করা হয়েছে: 2026-11-14 — ডেটা XAIPART-এর কম্পোনেন্ট ইঞ্জিনিয়ারিং টিম দ্বারা যাচাই ও কিউরেট করা হয়েছে

সম্পর্কিত অনুসন্ধান

OPA196ID datasheet OPA196ID pinout OPA196ID datasheet pdf OPA196ID equivalent OPA196ID replacement OPA196ID cross reference OPA196ID vs OPA197IDR OPA196ID SOIC-8 footprint OPA196ID 36V amplifier OPA196ID application circuit Texas Instruments OPA196ID OPA196ID price OPA196ID stock

সম্পর্কিত কম্পোনেন্ট ও শর্তাবলী

Texas Instruments OPA196ID OPA196 OPAx196 OPA2196 OPA4196 OPA197IDR operational amplifier op amp precision amplifier rail-to-rail amplifier mux-friendly input 36 V amplifier SOIC-8 QFN family surface mount SMD analog signal conditioning industrial sensor interface data acquisition common-mode voltage input offset voltage gain bandwidth product slew rate
তাৎক্ষণিক বিলওয়াছে রেকোজিউইট
সম্পূর্ণ বিবরণ পূরণ করুন — আমাদের সেলস টিম 24 ঘণ্টার মধ্যে উত্তর দেবে
পার্ট নম্বর উৎপাদক প্যাকেজ QTY লক্ষ্যমূল্য প্রসারিত
✓
বিল প্রস্তুত করা হয়েছে!

আমরা ২৪ ঘণ্টার মধ্যে আপনার ইমেইলে প্রত্যুত্তর দেব

1
RFQ জমা হয়েছে
2
কোটেশন পাওয়া গেছে
3
অর্ডার দেওয়া হয়েছে
4
পেমেন্ট
5
শিপ করা হয়েছে
6
ডেলিভারি হয়েছে
RFQ বিবরণ দেখুন