SN75154N - Quad Differential RS-232 Line Receiver | Texas Instruments
MPN: SN75154N ✓ সক্রিয়SN75154N সারাংশ
A differential line receiver converts the voltage difference between a pair of signal conductors into a digital logic level. This differential signaling helps reject common-mode voltage present on the cable or circuit board. The SN75154 family is intended for data-terminal equipment and data-communication equipment interfaces where multiple RS-232 channels are needed. Its four receiver channels make it suitable for compact multiport interface assemblies, industrial control links, and legacy peripheral equipment.
According to the manufacturer product information, the SN75154 has an input resistance of 7 kΩ over the full EIA/TIA-232-E voltage range. Its input threshold is adjustable to meet fail-safe requirements without external components. These features are important in RS-232 systems where an open, short, or inactive driver can place the receiver input into a valid, predictable logic state. The adjustable threshold can therefore help establish system behavior before a connected transmitter becomes active.
The SN75154N uses Schottky input logic and provides four differential receiver channels in one monolithic device. It is suited to point-to-point links, interface isolation, receive-side logic interfacing, and systems that need more than one RS-232 input but do not require the corresponding transmit drivers. The four independent channels also allow a single package to handle several communication ports while reducing component count and board area compared with four single-receiver packages.
Designers should provide a stable 5 V supply, place input and ground connections to minimize loop area, and account for the logic thresholds and common-mode voltage limits of the connected RS-232 network. Decoupling capacitors should be positioned close to the supply pins, and unused receiver inputs should be handled according to the manufacturer's pin-description and application guidance so that they remain in a defined state. A pull-up or pull-down arrangement may be needed where the interface must maintain a fail-safe state during startup or cable disconnection.
This product page combines the manufacturer description, interface standards, package information, sourcing guidance, and practical implementation considerations. It also distinguishes the SN75154N from related orderable suffixes and identifies the limits of drop-in replacement decisions: electrical equivalence alone is insufficient unless the package, pin arrangement, supply requirements, and receiver thresholds also match the original design.
এর জন্য ড্রপ-ইন বিকল্প SN75154N — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।
SN75154NG4
✅ ড্রপ-ইন📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)
SN75154NE4
✅ ড্রপ-ইন📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)
SN75154
✅ ড্রপ-ইন📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)
SN75154N বিশেষণ
| Product Type | Quadruple differential line receiver |
| Receiver Channel Count | 4 channels |
| সাপ্লাই ভোল্টেজ | 5 V typical single-supply operation |
| Interface Standard | ANSI Standard EIA/TIA-232-E |
| Telecommunication Recommendation | ITU Recommendation V.28 |
| Input Resistance | 7 kΩ over the full EIA/TIA-232-E voltage range |
| Input Threshold | Adjustable to meet fail-safe requirements without external components |
| Logic Technology | Low-power Schottky line receiver |
| Supported Signal Type | Differential line signaling |
| Primary Application | RS-232 data-terminal equipment and data-communication equipment interfaces |
| Additional Application | Short-distance single-line point-to-point data transmission |
| Additional Function | Level translation |
| প্যাকেজ | 16-pin PDIP |
| মাউন্টিং টাইপ | Through-hole |
SN75154N 16-pin pdip পিন কনফিগারেশন গাইড
SN75154N (16-pin pdip প্যাকেজ)-এর পিন কনফিগারেশন। পিন নম্বরিং, ফাংশন এবং সংযোগ ডায়াগ্রাম প্রস্তুতকারকের ডেটাশিটে সংজ্ঞায়িত করা আছে। সঠিক ফুটপ্রিন্ট এবং সোল্ডারিং নির্দেশিকার জন্য এটি দেখুন।
এর জন্য বিস্তারিত পিনআউট ডেটা পাওয়া যায়নি SN75154N.
দেখুন ডেটাশিট সম্পূর্ণ পিন কনফিগারেশনের জন্য।
সাধারণ ব্যবহার
SN75154N এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: Multiport RS-232 Interface Equipment, Industrial Control Terminal, Point-to-Point Data Links, Legacy Peripheral Connectivity, Level Translation, Data Communication Equipment.
Multiport RS-232 Interface Equipment
The SN75154N is well suited to equipment that receives data from several RS-232 ports because it combines four differential receiver channels in one 16-pin PDIP package. Each channel can recover a logic signal from an EIA/TIA-232-E-compatible line while rejecting voltage shared by the signal pair. This reduces the number of receiver packages needed compared with a design using four separate single-channel devices. The 5 V supply architecture also simplifies integration with legacy TTL/CMOS logic. Because the receiver has an adjustable fail-safe threshold, a product designer can define the state presented when a cable is absent or the remote transmitter is inactive, improving predictable behavior during startup and field-service events.
সুপারিশকৃত
Industrial Control Terminal
The SN75154N can form the receive section of a legacy industrial controller that communicates with RS-232 equipment such as printers, scales, test fixtures, or configuration tools. Four differential receiver channels allow one controller board to accept multiple equipment links, while the EIA/TIA-232-E and V.28 interface focus provides a defined connection to standard RS-232 equipment. Its monolithic low-power Schottky implementation supports a conventional 5 V system. Before using the receiver in a temperature-extreme factory environment, confirm the device's operating-temperature and ESD limits against the enclosure, cable length, and industrial grounding conditions.
সুপারিশকৃত
Point-to-Point Data Links
The SN75154N is appropriate for relatively short, single-line, point-to-point data paths where differential receive behavior improves signal reliability. The four channels can be assigned to separate links when a system needs compact channel density, or left partly unused when only one receiver is required. Its 7 kΩ input resistance is specified across the full EIA/TIA-232-E voltage range, providing a defined input loading characteristic for the line interface. Because this is a receiver rather than a complete transceiver, the transmitting side must be implemented separately with a suitable line driver and the same ground-reference strategy.
সুপারিশকৃত
Legacy Peripheral Connectivity
The SN75154N supports the receive side of legacy RS-232 peripherals used for configuration, diagnostics, firmware loading, or service access. Its four-channel architecture is useful in instrument and controller products that expose several serial service ports without dedicating a receiver IC to each connector. The adjustable input threshold can help implement fail-safe behavior for disconnected cables, reducing ambiguity in command parsers. Board-level implementation should include an RS-232 protection strategy, controlled reference ground, short return paths, and connector considerations suited to the cable environment; logic-level compliance alone does not provide complete electrostatic or surge protection.
সুপারিশকৃত
Level Translation
Beyond conventional RS-232 ports, the SN75154N can be used as a differential-to-logic level translator when the input signals remain within the receiver's specified voltage and common-mode limits. Four translated channels in one package can reduce component count in equipment that handles several control or status lines. The receiver's fail-safe threshold is particularly helpful where an inactive or floating source must map to a predictable logic level. The design must preserve the receiver's common-reference arrangement and must not exceed its specified input limits. Confirming the exact logic thresholds and input ranges from the manufacturer datasheet is essential before treating it as a general-purpose differential translator.
সুপারিশকৃত
Data Communication Equipment
The SN75154N is explicitly suited to the receive interface of data-communication equipment that follows the EIA/TIA-232-E interface model. A communications product with several inbound channels can use the four receiver circuits to convert differential line voltages into digital signals for a controller or bus transceiver. This can simplify board partitioning while maintaining a conventional 5 V supply domain. Production designs should still validate cable length, connector wiring, signal polarity, input common-mode range, and ground-reference behavior against the complete system specification. The SN75154N handles receive-side signal conditioning; protection, isolation, transmit drive, and higher-level protocol functions remain separate design tasks.
সুপারিশকৃত
সুপারিশকৃত পণ্যের সারসংক্ষেপ
এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা SN75154N — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।
নির্বাচন গাইড
বিকল্পের সাথে তুলনা
| পারামিটার | এই পণ্য | SN75154NG4 | SN75154NE4 | SN75154 |
|---|---|---|---|---|
| Package | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP, exact orderable suffix to confirm |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Receiver Channel Count | 4 channels | 4 channels | 4 channels | 4 channels |
| Product Function | Quadruple differential line receiver | Quadruple differential line receiver | Quadruple differential line receiver | Quadruple differential line receiver |
| Supply Voltage | 5 V typical single-supply operation | 5 V typical single-supply operation | 5 V typical single-supply operation | 5 V typical single-supply operation |
| Input Resistance | 7 kΩ over the full EIA/TIA-232-E voltage range | 7 kΩ over the full EIA/TIA-232-E voltage range | 7 kΩ over the full EIA/TIA-232-E voltage range | 7 kΩ over the full EIA/TIA-232-E voltage range |
| Input Threshold | Adjustable for fail-safe operation without external components | Adjustable for fail-safe operation without external components | Adjustable for fail-safe operation without external components | Adjustable for fail-safe operation without external components |
| Interface Standards | ANSI EIA/TIA-232-E and ITU V.28 | ANSI EIA/TIA-232-E and ITU V.28 | ANSI EIA/TIA-232-E and ITU V.28 | ANSI EIA/TIA-232-E and ITU V.28 |
মূল পার্থক্যসমূহ
- Four RS-232 receive functions in one package (বনামSN75154NG4)
- Differential receive operation with defined input loading (বনামSN75154NE4)
- Fail-safe threshold adjustment without external components (বনামSN75154)
ডিজাইন নোট
Route each differential receiver pair with a continuous return reference and minimize loop area between the pair. Place supply bypass capacitance directly at the SN75154N power and ground pins, using a short and low-inductance connection to the ground plane. Avoid sharing a narrow ground path between bypass current and external connector return current, because shared impedance can shift the receiver reference and reduce the benefit of differential signaling.
Do not substitute a receiver solely because it is labeled RS-232. Verify the package and pinout, 5 V supply compatibility, input common-mode range, output thresholds, enable behavior, propagation delay, and fail-safe threshold. The SN75154N is a receiver-only IC, so a design also needs a separate transmit driver and appropriate connector protection. Confirm unused-channel connections using the manufacturer pin-description table.
Keep RS-232 connector and cable protection close to the connector so surge or ESD current does not flow through logic-board traces. Use the device's differential input behavior as part of the signal strategy, but maintain a controlled ground reference and observe the specified input common-mode voltage range. For long or noisy cables, validate thresholds and behavior at the receiver rather than assuming ideal differential immunity.
Provide a stable 5 V rail with local bypass at the receiver. The monolithic low-power Schottky implementation is designed for conventional single-supply operation, but the exact supply-current limit and power-dissipation rating must be checked in the datasheet before adding external loads. Use the same supply-domain conventions for input thresholds and output logic levels to avoid an intermediate voltage range at the interface.
কমপ্লায়েন্স তথ্য
The manufacturer page and distributor snippets do not state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status for SN75154N. Use the current manufacturer product documentation for compliance declarations.