Analog Devices

VSC7153XSS-02 - 24-PHY 3Gbps SAS Expander | Analog Devices

MPN: VSC7153XSS-02 ✓ সক্রিয়
সর্বনিম্ন অর্ডার পরিমাণ: 1 |

VSC7153XSS-02 সারাংশ

The Analog Devices VSC7153XSS-02 is a 24-PHY SAS edge/fanout expander supporting 1.5 Gbps and 3.0 Gbps operation, with table routing and an SSP engine. It is intended for storage systems that require multiple SAS links to be consolidated, routed, or expanded between initiators, disks, and storage subsystems. The exact package dimensions, pin configuration, electrical limits, and environmental ratings should be confirmed in the manufacturer datasheet before layout or qualification begins.

A SAS expander is a semiconductor interface device that sits within the Serial Attached SCSI hierarchy and manages a group of SAS physical links. In this broader storage hierarchy, the expander provides link aggregation and routing between a host-facing interface and multiple SAS endpoints. The VSC7153XSS-02 combines 24 physical-layer channels with table-based routing, allowing a storage designer to construct scalable fan-in or fan-out topologies rather than connecting every endpoint through a separate host port.

The device’s three principal documented characteristics are its 24-PHY configuration, support for both 1.5 Gbps and 3.0 Gbps SAS link rates, and hardware-assisted table routing through its SSP engine. These features make it relevant to SAS 1.5 and SAS 3.0 system architectures. Because the expander operates in the data path, system-level validation should include link training, negotiated-rate behavior, error handling, topology discovery, and recovery after cable or endpoint faults.

The VSC7153XSS-02 is best understood as a protocol-aware interface component rather than a general-purpose I/O expander. Its PHY count determines how many physical SAS links can participate in a fabric, while the routing engine determines how those links are mapped. In a practical system, this can simplify backplane organization, reduce the number of direct host connections, and provide a defined switching layer between initiators and drive enclosures. Firmware and validation must still confirm routing-table behavior against the exact system topology.

Typical applications include SAS disk-array controllers, storage backplanes, direct-attached storage enclosures, server storage fabrics, and fanout systems that expand a smaller number of host links into a larger set of device links. It is particularly relevant when a design requires table-based routing rather than a simple fixed point-to-point connection. Storage architects should evaluate it alongside controller resources, connector density, cable-length limits, enclosure power, and the target drive-generation requirements.

The primary design consideration is preserving signal integrity across every high-speed SAS path. Differential routing, connector launches, return paths, reference-plane continuity, and compliance testing are central to a reliable implementation. The physical package and pin map must be taken directly from the manufacturer datasheet, while power, ground, thermal, and decoupling decisions should be based on the documented operating limits for the ordered device.

This page organizes the documented VSC7153XSS-02 capabilities, application context, comparison parameters, and engineering checks into a practical reference. It also distinguishes confirmed product facts from parameters that must be established from the manufacturer datasheet, helping procurement, hardware, and validation teams align before beginning an SAS fabric design.

এর জন্য ড্রপ-ইন বিকল্প VSC7153XSS-02 — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।

এই সিরিজের ভ্যারিয়েন্ট

একই সিরিজের মডেল যেগুলো drop-in compatible VSC7153XSS-02 (একই form factor এবং footprint).

এই পণ্যের জন্য কোনো ড্রপ-ইন বিকল্প পাওয়া যায়নি।

বিকল্প অনুরোধ করুন

VSC7153XSS-02 বিশেষণ

Product Type SAS edge/fanout expander
Physical Layer Count 24 PHY
Supported SAS Link Rate 1.5 Gbps
Supported SAS Link Rate 3.0 Gbps
Routing Architecture Table routing
Routing Engine SSP engine
Device Classification IC interface controller
Fabric Function SAS edge/fanout expansion

VSC7153XSS-02 standard পিন কনফিগারেশন গাইড

VSC7153XSS-02 (standard প্যাকেজ)-এর পিন কনফিগারেশন। পিন নম্বরিং, ফাংশন এবং সংযোগ ডায়াগ্রাম প্রস্তুতকারকের ডেটাশিটে সংজ্ঞায়িত করা আছে। সঠিক ফুটপ্রিন্ট এবং সোল্ডারিং নির্দেশিকার জন্য এটি দেখুন।

VSC7153XSS-02-এর জন্য standard প্যাকেজ পিনআউট ডায়াগ্রাম

এর জন্য বিস্তারিত পিনআউট ডেটা পাওয়া যায়নি VSC7153XSS-02.

দেখুন ডেটাশিট সম্পূর্ণ পিন কনফিগারেশনের জন্য।

সাধারণ ব্যবহার

VSC7153XSS-02 এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: SAS Disk-Array Controller Backplane, Direct-Attached Storage Enclosure, Server Storage Fabric Expansion, SAS Edge Switching Layer, External SAS Storage Enclosure, Enterprise Storage Backplane Management.

🖥️

SAS Disk-Array Controller Backplane

The VSC7153XSS-02 fits a storage backplane that must organize multiple SAS physical links through a controlled routing layer. Its 24 PHYs provide a substantial number of connections, while support for 1.5 Gbps and 3.0 Gbps allows the fabric to accommodate different SAS generations. Table routing and the SSP engine are useful when initiator-to-device paths must be defined and managed dynamically. Implementation should preserve differential-pair geometry, provide uninterrupted reference planes, and validate link training across every supported rate. Firmware must also confirm route-table programming, fault isolation, and recovery behavior.

🖥️

Direct-Attached Storage Enclosure

A direct-attached storage enclosure can use the VSC7153XSS-02 when it needs to fan a limited number of host-facing SAS links out to numerous drive-side links. The device’s 24-PHY arrangement reduces the need for direct point-to-point wiring across the enclosure backplane, while table routing defines how initiator paths reach selected drives. The 1.5 Gbps and 3.0 Gbps support makes it relevant to mixed-generation SAS storage plans. Before release, engineers should confirm connector and cable reach, power-loss behavior, thermal loading, and whether the enclosure requires hot-swap or redundant-management features not specified in the available summaries.

🏭

Server Storage Fabric Expansion

The VSC7153XSS-02 is suitable for a server storage fabric that expands a host interface into a larger endpoint population. Its 24 PHYs and hardware-assisted table routing can consolidate topology management into a dedicated expander layer, allowing storage controllers to address drives through a structured SAS fabric. Using both documented rates, 1.5 Gbps and 3.0 Gbps, supports design planning across different drive and backplane capabilities. Validation should include negotiated-rate interoperability, congestion behavior, PHY fault containment, firmware routing-table updates, and full enclosure power-cycle testing before production deployment.

🌐

SAS Edge Switching Layer

The VSC7153XSS-02 can serve as a switching layer between SAS initiators and endpoint devices when the system architecture requires table-driven path control rather than a fixed wiring plan. The SSP engine and 24-PHY count support centralized route management for moderate-density fabrics. This arrangement can simplify point-to-point cabling and make topology changes easier for firmware to manage. Engineering teams should establish how routes are loaded, how duplicate or invalid table entries are handled, and how the fabric responds to link loss. Signal-integrity testing must cover every supported 1.5 Gbps and 3.0 Gbps operating mode.

💾

External SAS Storage Enclosure

An external SAS enclosure is a practical use case for the VSC7153XSS-02 when it must expose multiple drive connections through a managed expander fabric. The 24-PHY organization can support a larger enclosure while table routing controls which host path reaches each drive. The device’s documented 1.5 Gbps and 3.0 Gbps capability allows compatibility planning for two SAS link generations, subject to connector, cable, and target-device constraints. Designers should pay particular attention to power-rail sequencing, startup transients, connector geometry, enclosure airflow, and whether the selected drive mix requires rate conversion or only common-rate operation.

🏭

Enterprise Storage Backplane Management

The VSC7153XSS-02 can support enterprise backplanes where a predictable routing table and a high channel count simplify physical design. By placing 24 PHYs behind a table-routing engine, the architecture separates physical link expansion from initiator-side addressing. Support for 1.5 Gbps and 3.0 Gbps provides a common platform for planned SAS generations, although operation across mixed generations must be validated explicitly. Reliability testing should examine hot-plug behavior, power interruption during route updates, PHY error counters, cable faults, and recovery without corrupting the active topology.

What is the VSC7153XSS-02?
The VSC7153XSS-02 is a 24-PHY SAS edge/fanout expander from Analog Devices that supports 1.5 Gbps and 3.0 Gbps SAS operation. It includes table routing and an SSP engine for directing physical SAS links within a storage fabric. The manufacturer product listing and distributor technical pages identify the device as an interface controller rather than a general-purpose converter or discrete transceiver.
What are the key specifications of VSC7153XSS-02 that engineers should know?
The principal VSC7153XSS-02 specifications are 24 physical-layer channels, support for 1.5 Gbps and 3.0 Gbps SAS links, table-based routing, and an SSP routing engine. These features place the device in the SAS interface-controller category. Electrical limits, operating temperature, package dimensions, pin count, and power consumption should be established from the manufacturer datasheet before schematic or layout release.
Where can I download the VSC7153XSS-02 datasheet PDF?
The VSC7153XSS-02 datasheet can be located through the product’s manufacturer documentation or the linked FindIC technical page, which identifies the device as a 24-PHY, 1.5 Gbps and 3 Gbps SAS edge/fanout expander. Use the manufacturer datasheet for the authoritative pin description, electrical characteristics, package drawing, and application guidance before assigning PCB connections.
Where can I find the VSC7153XSS-02 pinout?
Use the pin-description table and package drawing in the Analog Devices VSC7153XSS-02 datasheet to locate the pinout. The available product summaries confirm the SAS expander function and 24-PHY organization but do not provide a complete numbered pin map. Do not infer pin assignments from adjacent VSC devices because bias, power, ground, reference, and high-speed signal requirements must follow the exact package drawing.
Is the VSC7153XSS-02 suitable for SAS 3.0 storage systems?
Yes, the VSC7153XSS-02 is suitable for a SAS 3.0-class design when its other electrical, thermal, and protocol requirements are satisfied. The device is documented as supporting 3.0 Gbps SAS operation as well as 1.5 Gbps, together with table routing across 24 PHYs. Suitability for a particular enclosure still depends on link training, reach, power integrity, and system-level validation.
Where can I buy VSC7153XSS-02 online?
Use the Request a Quote form on this page to request VSC7153XSS-02 availability, commercial terms, and lead time for the exact ordering code. The exact suffix VSC7153XSS-02 should be stated on the request so that package, qualification, and intended-market requirements are matched correctly. Stock status can change and should be confirmed through the quotation workflow.
What is the price of VSC7153XSS-02?
Current VSC7153XSS-02 pricing is handled through the Request a Quote form on this page. The form permits a procurement request against the exact MPN rather than an ambiguous SAS expander family. Volume, delivery schedule, packaging, and component traceability requirements can be included with the request so that the commercial response reflects the intended production program.
What is the lead time for VSC7153XSS-02?
Request the current VSC7153XSS-02 lead time through the Request a Quote form on this page. Lead time can depend on exact suffix, order quantity, production schedule, and delivery location. The product is currently offered for quotation through the XAIPART sales workflow, and a written quotation is the appropriate way to confirm availability and timing.
Is VSC7153XSS-02 in stock?
VSC7153XSS-02 stock status should be confirmed through the Request a Quote form on this page because availability can change with order volume and replenishment timing. The exact ordering code is important for preventing substitution with a different package or temperature option. The quotation response should state available quantity, delivery schedule, and the confirmed manufacturer part number.
VSC7153XSS-02 vs VSC7153SS-02 - which is the correct ordering code?
VSC7153XSS-02 and VSC7153SS-02 are distinct ordering codes and should not be treated as interchangeable without checking the manufacturer package and suffix tables. The target product is VSC7153XSS-02, a 24-PHY SAS edge/fanout expander supporting 1.5 Gbps and 3.0 Gbps operation. Use the exact package code and ordering information from the datasheet when comparing the two devices.
When should I choose VSC7153XSS-02 over another SAS expander?
Choose VSC7153XSS-02 when a storage architecture needs a documented 24-PHY SAS expander with both 1.5 Gbps and 3.0 Gbps link support, table routing, and an SSP engine. It is particularly relevant to backplanes and enclosures that implement fan-in or fan-out routing between initiators and devices. The decision should also verify package fit, electrical limits, thermal performance, and protocol compatibility.
Is VSC7153XSS-02 suitable for a fanout storage backplane?
Yes, VSC7153XSS-02 is explicitly identified as a SAS edge/fanout expander and provides 24 PHYs with table routing. Those characteristics support backplanes that need to route a controlled set of initiator links toward multiple drive or enclosure links. Physical implementation still requires careful differential-pair routing, connector launch design, power delivery, thermal analysis, and link-training validation.
What can replace VSC7153XSS-02?
No drop-in replacement for VSC7153XSS-02 can be confirmed from the available cross-reference results. Candidate devices in the related VSC family are not automatically pin-compatible, and the cross-reference search did not establish a same-package substitute with verified electrical and protocol equivalence. Treat any proposed replacement as a redesign candidate until its pinout, package, SAS rates, routing engine, and firmware requirements are validated.
Is VSC7153XSS-02 the same as VSC7155VU-02?
No, VSC7153XSS-02 and VSC7155VU-02 are different members of the related VSC product family and their ordering codes are not shown as direct equivalents. The target is documented as a 24-PHY, 1.5 Gbps and 3.0 Gbps SAS edge/fanout expander. Because the available results do not provide a pin-for-pin comparison, do not substitute one device for the other without a full hardware and firmware review.
What is the best Analog Devices equivalent for VSC7153XSS-02?
The related Analog Devices family candidates include VSC7155VU-02, VSC7147RM-02, VSC7156XYT-03, and VSC7153SS-02, but none can be identified as a confirmed drop-in equivalent to VSC7153XSS-02 from the available results. A defensible equivalence requires the same package footprint, identical pin functions, compatible power rails and clocking, supported SAS rates, and equivalent routing behavior. Request manufacturer documentation before selecting a substitute.

এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা VSC7153XSS-02 — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।

নির্বাচন গাইড

Choose VSC7153XSS-02 when a SAS storage architecture specifically requires a 24-PHY expander supporting 1.5 Gbps and 3.0 Gbps links with table routing and an SSP engine. It is a strong fit for backplanes, direct-attached enclosures, and external storage systems where initiator links must fan out to multiple endpoints through a managed fabric. The related VSC7155VU-02, VSC7156XYT-03, VSC7147RM-02, VSC7153SS-02, and VSC8502XML should be considered only after their exact packages, pin assignments, electrical limits, PHY counts, and routing functions are verified. None should be treated as a drop-in substitute without a documented manufacturer comparison. If the design needs 24 PHYs, dual documented link rates, and table-based routing, the VSC7153XSS-02 is the strongest confirmed starting point. If those requirements can be reduced, broader family evaluation may simplify sourcing or design reuse.

বিকল্পের সাথে তুলনা

পারামিটার এই পণ্য
Brand Analog Devices
Product Type SAS edge/fanout expander
Physical Layer Count 24 PHY
Supported Link Rates 1.5 Gbps and 3.0 Gbps
Routing Method Table routing
Routing Engine SSP engine
Device Classification IC interface controller

মূল পার্থক্যসমূহ

  • Broad physical-layer count for managed SAS fabrics (বনামVSC7155VU-02)
  • Support for two documented SAS link generations (বনামVSC7156XYT-03)
  • Integrated table-routing architecture (বনামVSC7147RM-02)

ডিজাইন নোট

Route every SAS differential pair as a controlled impedance transmission line with symmetrical geometry, continuous reference planes, and minimal stubs. Keep PHY connections away from noisy switching paths and use manufacturer-recommended connector and termination arrangements. Validate eye quality, jitter, insertion loss, and return loss at both documented 1.5 Gbps and 3.0 Gbps rates because an acceptable link-training result does not replace physical-layer margin testing.

Build the PCB layer stack around the manufacturer’s package, connector, and high-speed guidance before assigning traces. Maintain continuous ground and power planes beneath the routing region, provide ample via transitions only where the impedance design requires them, and avoid plane splits that interrupt return current. Exact decoupling, via-in-pad, and thermal-relief instructions must come from the datasheet because the package and electrical limits are not identified in the available summaries.

Do not treat the similarly named VSC7153SS-02 or other VSC-family members as automatic substitutes for VSC7153XSS-02. Ordering codes can encode different package, temperature, or qualification options, and the routing functions may not be equivalent. Before schematic reuse or firmware transfer, verify pin names, power rails, reset behavior, clocking, SAS-rate support, interrupt signaling, and the routing-table model against each exact datasheet.

Plan the power tree so the device receives clean, sequenced rails under both normal operation and fault recovery. Assess startup current, rail tolerance, decoupling, and the contribution of neighboring high-speed circuitry before assigning capacitor values. Check power sequencing against the exact enable and reset requirements, and test repetitive power cycles because storage systems must recover cleanly after interrupted route-table updates or enclosure power loss.

কমপ্লায়েন্স তথ্য

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
লিড ফ্রি
Unknown
হ্যালোজেন ফ্রি
Unknown
কনফ্লিক্ট মিনারেলস
Unknown

Compliance status was not identified in the available product summaries. Confirm RoHS, REACH, lead-free, halogen-free, conflict-minerals, and automotive qualification status in the manufacturer documentation for the exact ordering code.

ডেটা যাচাই করা হয়েছে: 2026-11-11 — ডেটা XAIPART-এর কম্পোনেন্ট ইঞ্জিনিয়ারিং টিম দ্বারা যাচাই ও কিউরেট করা হয়েছে

সম্পর্কিত অনুসন্ধান

VSC7153XSS-02 datasheet VSC7153XSS-02 pinout VSC7153XSS-02 datasheet pdf VSC7153XSS-02 specifications VSC7153XSS-02 equivalent VSC7153XSS-02 replacement VSC7153XSS-02 cross reference VSC7153XSS-02 price VSC7153XSS-02 stock Analog Devices VSC7153XSS-02 VSC7153XSS-02 SAS expander VSC7153XSS-02 storage backplane

সম্পর্কিত কম্পোনেন্ট ও শর্তাবলী

Analog Devices VSC7153XSS-02 SAS expander SAS edge/fanout expander 24-PHY 1.5 Gbps SAS 3.0 Gbps SAS table routing SSP engine IC interface controller Serial Attached SCSI storage fabric disk-array backplane direct-attached storage differential-pair routing link training power sequencing RoHS REACH AEC-Q100
তাৎক্ষণিক বিলওয়াছে রেকোজিউইট
সম্পূর্ণ বিবরণ পূরণ করুন — আমাদের সেলস টিম 24 ঘণ্টার মধ্যে উত্তর দেবে
পার্ট নম্বর উৎপাদক প্যাকেজ QTY লক্ষ্যমূল্য প্রসারিত
✓
বিল প্রস্তুত করা হয়েছে!

আমরা ২৪ ঘণ্টার মধ্যে আপনার ইমেইলে প্রত্যুত্তর দেব

1
RFQ জমা হয়েছে
2
কোটেশন পাওয়া গেছে
3
অর্ডার দেওয়া হয়েছে
4
পেমেন্ট
5
শিপ করা হয়েছে
6
ডেলিভারি হয়েছে
RFQ বিবরণ দেখুন