AD548AQ/+ - Precision Low-Power BiFET Op Amp | Analog Devices
MPN: AD548AQ/+ ✓ چالاکAD548AQ/+ گشتی
A BiFET operational amplifier is an amplifier whose input stage uses field-effect transistors rather than bipolar input transistors. This architecture belongs to the operational-amplifier hierarchy and provides very high input impedance, low input bias current, and effective handling of high-impedance sources. The AD548 family is designed for low-power instrumentation where a low-noise, high-impedance input stage is more important than the drive current available from conventional bipolar operational amplifiers.
The AD548AQ/+ provides a maximum offset voltage of 250 µV and maximum offset-voltage drift of 2 µV/°C. Its voltage noise is specified as 2 µV peak-to-peak, while the slew rate is 2 V/µs and the unity-gain bandwidth is 1 MHz. A maximum quiescent current of 200 µA supports low-power signal-chain operation, and the 10 pA warmed input bias current reduces loading on sensitive sensors, transducers, and high-resistance feedback networks.
The amplifier uses ion-implanted FET and laser wafer-trimming technologies. Ion implantation supports low-noise transistor construction, while laser trimming enables accurate offset-voltage correction. These techniques are particularly useful in feedback configurations where DC offset can influence the accuracy of an instrumentation amplifier, current-to-voltage converter, or low-level sensor front end. Its 1 MHz bandwidth provides useful speed for general precision analog signals while retaining the low-power characteristics of the AD548 family.
Typical applications include pH and electrochemical sensor amplification, photodiode and optical-sensor signal conditioning, low-current measurement, capacitive-sensor interfaces, precision bridge amplifiers, and low-leakage instrumentation. The amplifier is also useful in battery-powered equipment because its 200 µA maximum quiescent current limits the standing current drawn from the supply. Care is required when adding output isolation or driving capacitive loads because high-impedance nodes can increase sensitivity to stray capacitance and leakage.
For each feedback divider, verify resistor values against the input bias-current, offset, and bandwidth requirements rather than relying only on nominal gain calculations. Keep sensitive input and feedback nodes short and physically separated from switching nodes and high-current return paths. Where leakage from PCB contamination or guarding matters, use guarding techniques and clean, low-flux materials around the input terminals.
This product record combines the AD548AQ/+ electrical characteristics with package information, sourcing guidance, practical application notes, and a qualified comparison of legacy ordering variants. It is designed to help engineers evaluate bias-current noise, offset stability, power consumption, and ceramic-package suitability before integrating the amplifier into precision analog systems.
جێگرەوەکانی جێگۆڕکێ بۆ AD548AQ/+ — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ AD548AQ/+ (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Input Bias Current, Package, Quiescent Current.
AD548AQ
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
AD548BQ
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →AD548AQ/+ زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| Product Type | Precision low-power BiFET operational amplifier |
| Input Bias Current | 10 pA maximum when warmed |
| ئێستای ئارام | 200 µA maximum |
| Offset Voltage | 250 µV maximum |
| Offset Voltage Drift | 2 µV/°C maximum |
| Voltage Noise | 2 µV peak-to-peak |
| Slew Rate | 2 V/µs |
| Unity-Gain Bandwidth | 1 MHz |
| Number of Channels | 1 channel |
| Circuit Count | 1 circuit |
| پاکێج | 8-pin CERDIP, hermetic sealed |
| جۆری دامەزراندن | Through-hole |
| Input Transistor Technology | Ion-implanted FET |
| Offset Trimming Technology | Laser wafer trimming |
ڕێنمایی ڕێکخستنی پینی AD548AQ/+ 8-pin cerdip, hermetic sealed
ڕێکخستنی پین بۆ AD548AQ/+ (پاکێجی 8-pin cerdip, hermetic sealed). ئەم پێکھاتە ئەنالۆگە پینی چوونەژوورەوە، دەرچوون و دابینکردنی وزەی ھەیە. سەرنج بدە بە داتاشیتی بەرھەمھێنەر بۆ ڕێکخستنەکانی پینی لادانی ئۆفسێت، قەرەبووکردنەوە و چالاککردن. گونجاوە بۆ ڕێکخستنی ئیشارەت و خولەکانی بەرزکەرەوە.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ AD548AQ/+.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
AD548AQ/+ گونجاوە بۆ 6 بەکارھێنانs: High-Impedance Sensor Signal Conditioning, Photodiode and Optical Measurement, Low-Current Measurement, Precision Bridge and Instrumentation Front End, Capacitive Sensing Interface, Battery-Powered Portable Instrumentation.
High-Impedance Sensor Signal Conditioning
The AD548AQ/+ fits electrochemical, pH, humidity, and resistive sensors whose source impedance would create excessive error with a bipolar-input amplifier. Its 10 pA maximum warmed input bias current limits sensor loading, while the 250 µV maximum offset voltage and 2 µV/°C maximum drift support stable amplification of slowly changing signals. Configure it as a noninverting or differential input stage, keep high-impedance nodes short, and consider guarding when board leakage or connector contamination could approach the amplifier’s bias-current contribution.
Photodiode and Optical Measurement
The AD548AQ/+ is appropriate for precision transimpedance stages used with photodiodes and other high-resistance optical sensors. Its 10 pA maximum warmed bias current limits the error caused by input bias current across a high-value feedback resistor, and the 2 V/µs slew rate can respond to small signals around the 1 MHz unity-gain bandwidth. The designer should still calculate feedback capacitance, diode capacitance, and stability margin because the ceramic-DIP device is intended primarily for lower-bandwidth precision measurements rather than high-speed optical communications.
Low-Current Measurement
For low-level current measurement, the AD548AQ/+ can form the input stage of a current-to-voltage converter using a precision feedback resistor. The 10 pA maximum warmed bias current produces less offset error than a bipolar amplifier when the feedback impedance is high, and the 200 µA maximum quiescent current supports low-power acquisition systems. Verify resistor tolerance and temperature coefficient, account for input leakage across the shunt or sensor, and use a guarded layout so contamination does not introduce a larger error than the amplifier itself.
Precision Bridge and Instrumentation Front End
The AD548AQ/+ can amplify the differential output of resistive strain gauges, pressure bridges, and other instrumentation sensors where excitation current and source impedance make bias-current error important. Its low offset voltage and low drift help preserve DC accuracy, while the low quiescent current is beneficial for portable test equipment. In a complete instrumentation chain, verify bridge excitation voltage, input common-mode range, resistor matching, and sensor grounding; the amplifier alone does not remove errors generated by bridge imbalance or sensor temperature coefficients.
Capacitive Sensing Interface
The AD548AQ/+ can serve as the amplifier in a charge-balance or capacitive-sensing front end where the sensor presents a very high source impedance. The 10 pA maximum warmed bias current limits DC loading, and the 1 MHz unity-gain bandwidth is adequate for many low-frequency sensor and cable systems. Stray capacitance can interact with high-value feedback resistors, so keep the sensor and amplifier input compact, use a defined ground reference, and validate settling time before increasing measurement bandwidth.
Battery-Powered Portable Instrumentation
The AD548AQ/+ fits portable measurement equipment where a conventional precision amplifier would consume too much standby power or load a sensor excessively. Its maximum quiescent current is 200 µA, and the low 10 pA maximum warmed bias current supports weak sources operated from a limited energy budget. Because total consumption also comes from references, conversion stages, and interface circuits, use duty-cycle control where measurement speed allows and evaluate the complete signal path for current draw and startup behavior.
داتای سەرچاوەی ئەندازیاری بۆ AD548AQ/+ — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | AD548AQ | AD548BQ |
|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Package | 8-pin CERDIP, hermetic sealed | 8-pin CERDIP, hermetic sealed | 8-pin CERDIP, hermetic sealed |
جیاکەرەوە سەرەکییەکان
- Exceptionally low input bias current for a precision amplifier (بەراورد بەAD548AQ)
- Legacy AD548AQ ordering form provides direct continuity (بەراورد بەAD548BQ)
- Low-power precision operation (بەراورد بەAD548AQ)
تێبینییەکانی دیزاین
Keep the amplifier input, feedback components, and sensitive sensor return on a quiet part of the PCB. Avoid routing them beside switching nodes, relay contacts, motor drive traces, and high-current supply paths. For high-impedance inputs, use guard traces where appropriate and minimize exposed board area around the input terminal. The 10 pA maximum warmed bias current is exceptionally low, so PCB contamination and connector leakage can become the dominant source of measurement error.
Do not assume that every AD548 suffix is an electrical and environmental drop-in replacement. Check the ordering table for grade temperature range, package material, and termination convention, then compare offset voltage, offset drift, bias current, quiescent current, bandwidth, and slew rate. The legacy AD548AQ ordering form is the closest documented match for AD548AQ/+, while AD548BQ requires grade-level verification before schematic approval.
Evaluate capacitive loading and feedback stability before increasing operating frequency. The 1 MHz unity-gain bandwidth is most useful for precision, low-frequency signals; high-value transimpedance resistors and sensor capacitance can create additional poles that reduce phase margin. Place compensation capacitors close to the relevant pins and validate the complete amplifier-and-sensor network with a transient response test rather than relying only on the unity-gain bandwidth specification.
زانیاری پابەندبوون
The AD548AQ/+ ordering suffix may denote a lead-free termination, but no explicit compliance statement is included. Compliance fields remain unknown rather than being inferred. AEC-Q100 qualification is not indicated for this precision analog device.