AD9100JD - Ultrahigh-Speed Track-and-Hold | Analog Devices
MPN: AD9100JD ✗ کۆتایی ژیانAD9100JD گشتی
A track-and-hold amplifier is a sampling circuit that captures an input voltage during a controlled track interval and then holds that voltage for conversion or measurement. Within the signal-chain hierarchy, the AD9100JD sits between a high-speed source and a downstream analog-to-digital converter, acting as a sampling bridge with a dedicated hold amplifier. Its mature high-speed complementary bipolar process and low-parasitic custom package support demanding high-speed and high-dynamic-range signal acquisition.
Key performance includes hold-mode distortion below 83 dBfs while sampling at 30 MSPS for analog input frequencies up to 12 MHz, and -74 dBfs at 20 MHz. The device also maintains less than 1 ps aperture jitter, supports capacitive loads up to 100 pF with little degradation in acquisition time, and provides 83 dB feedthrough rejection at 20 MHz. These characteristics make timing accuracy, isolation between track and hold intervals, and sampled-waveform fidelity central design considerations.
The AD9100JD uses a high-speed complementary bipolar process to achieve rapid settling during acquisition and low signal distortion during the hold interval. Its 250 MHz tracking bandwidth accommodates rapidly changing input waveforms, while the short acquisition interval reduces the time required to settle to the requested accuracy. The custom 20-lead package minimizes parasitic effects and supports the high-frequency behavior needed in sampling systems. A sidelong ceramic package also reflects its role as a high-performance laboratory and instrumentation component rather than a cost-sensitive production package.
Typical applications include high-speed data-acquisition front ends, flash and pipeline ADC input stages, pulsed signal capture, communications test equipment, spectroscopy, phase-sensitive measurements, and precision waveform instrumentation. The AD9100JD is particularly appropriate when a system requires 30 MSPS operation, accurate sub-1 ps aperture timing, low feedthrough, or acquisition into a substantially capacitive input network.
A critical design practice is to control clock and analog-signal routing so that clock feedthrough does not contaminate the held output. Keep the sampling clock away from sensitive input and output traces, terminate unused inputs appropriately, and use the package pin description and recommended application circuit in the Analog Devices datasheet when assigning the board layout. High-speed sampling performance also requires short return paths, a quiet reference source, and careful decoupling.
This product page combines the manufacturer specifications with application guidance, design cautions, pin and package information, verified lifecycle context, and a qualification search for true same-package replacements. That engineering-focused synthesis helps distinguish direct drop-in options from merely similar track-and-hold devices and supports faster component selection for high-speed acquisition systems.
جێگرەوەکانی جێگۆڕکێ بۆ AD9100JD — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ AD9100JD (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Product Type.
هیچ جێگرەوەی ڕاستەوخۆ بۆ ئەم بەرهەمە بەردەست نییە.
داوای جێگرەوەکان بکەAD9100JD زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| Product Type | Monolithic track-and-hold amplifier |
| Acquisition Time to 0.1% Accuracy | 13 ns |
| Acquisition Time to 0.01% Accuracy | 16 ns |
| Maximum Sampling Rate | 30 MSPS |
| Hold-Mode Distortion at 12 MHz Input and 30 MSPS | Less than 83 dBfs |
| Hold-Mode Distortion at 20 MHz Input and 30 MSPS | -74 dBfs |
| Tracking Bandwidth | 250 MHz |
| Aperture Jitter | Less than 1 ps |
| Feedthrough Rejection at 20 MHz | 83 dB |
| Maximum Drive Capacitance | 100 pF |
| Process Technology | Mature high-speed complementary bipolar process |
| پاکێج | 20-lead side-brazed skinny DIP ceramic package |
| Lead Count | 20 leads |
| Temperature Grades | Commercial, industrial, and military grades |
| 883 Qualification | Consult the factory for availability |
ڕێنمایی ڕێکخستنی پینی AD9100JD 20-lead side-brazed skinny dip ceramic package
ڕێکخستنی پین بۆ AD9100JD (پاکێجی 20-lead side-brazed skinny dip ceramic package). ئەم پێکھاتە ئەنالۆگە پینی چوونەژوورەوە، دەرچوون و دابینکردنی وزەی ھەیە. سەرنج بدە بە داتاشیتی بەرھەمھێنەر بۆ ڕێکخستنەکانی پینی لادانی ئۆفسێت، قەرەبووکردنەوە و چالاککردن. گونجاوە بۆ ڕێکخستنی ئیشارەت و خولەکانی بەرزکەرەوە.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ AD9100JD.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
AD9100JD گونجاوە بۆ 6 بەکارھێنانs: High-Speed ADC Input Acquisition, Pulsed Signal Capture, Communications Waveform Instrumentation, Precision Spectroscopy Signal Capture, Phase-Sensitive Measurement, High-Speed Data-Acquisition Systems.
High-Speed ADC Input Acquisition
The AD9100JD is suited to the sampling stage in front of a high-speed analog-to-digital converter because it acquires to 0.1% accuracy in 13 ns and reaches 0.01% accuracy in 16 ns. Its 250 MHz tracking bandwidth lets the input follow rapid transitions during the track interval, while less than 1 ps aperture jitter limits timing uncertainty in the conversion aperture. According to the Analog Devices AD9100 datasheet, hold-mode distortion is below 83 dBfs at a 12 MHz input when sampling at 30 MSPS. The designer should confirm converter polarity, input range, kickback behavior, and whether the converter requires a sample-and-hold function or a dedicated driver.
پێشنیارکراو
Pulsed Signal Capture
The AD9100JD can capture short-duration or rapidly changing events when the system needs both a wide tracking bandwidth and a defined hold interval. Its 250 MHz tracking bandwidth supports high-frequency input activity, and the 13 ns acquisition to 0.1% accuracy limits the interval required to settle before capture. Less than 1 ps aperture jitter also helps preserve the timing relationship between the sampled waveform and its trigger. For practical pulsed measurements, keep the clock and analog paths short, isolate high-energy trigger circuitry, and verify the sample-and-hold timing sequence against the 30 MSPS operating capability documented by Analog Devices.
پێشنیارکراو
Communications Waveform Instrumentation
The AD9100JD is appropriate for communications test equipment that must observe carrier-related waveforms with controlled sample timing. Its hold-mode performance reaches below 83 dBfs at a 12 MHz analog input and 30 MSPS sampling rate, while the value becomes -74 dBfs at a 20 MHz input according to the Analog Devices AD9100 datasheet. The sub-1 ps aperture jitter and 83 dB feedthrough rejection at 20 MHz help separate the intended sampled signal from timing-related artifacts. PCB implementation should use controlled impedance, a continuous return plane, and careful separation between the sampling clock and high-level signal paths.
پێشنیارکراو
Precision Spectroscopy Signal Capture
For spectroscopy instrumentation, the AD9100JD can capture detector or front-end outputs that require accurate settling before digitization. The 13 ns acquisition to 0.1% accuracy and 16 ns acquisition to 0.01% accuracy provide a defined settling interval, while less than 1 ps aperture jitter reduces uncertainty in the sampling instant. Its ability to drive loads up to 100 pF with little acquisition degradation can simplify interfacing to suitable amplifier or converter stages. The system designer should still account for detector noise, analog bandwidth, clock jitter, and conversion settling, because the track-and-hold amplifier does not correct noise or bandwidth limitations elsewhere in the signal chain.
پێشنیارکراو
Phase-Sensitive Measurement
The AD9100JD supports phase-sensitive measurement systems where repeatable acquisition timing determines the integrity of an in-phase or quadrature result. Less than 1 ps aperture jitter limits sampling-time uncertainty, and the 250 MHz tracking bandwidth permits the amplifier to follow signals before the hold interval begins. Its 30 MSPS capability and low hold-mode distortion make it useful for synchronized detector measurements. Designers should minimize clock-to-input coupling, provide clean low-jitter sampling clocks, and use the manufacturer application circuit to establish the correct track and hold timing relative to the measurement cycle.
پێشنیارکراو
High-Speed Data-Acquisition Systems
The AD9100JD fits the central sampling function of a high-speed data-acquisition system that must repeatedly acquire an analog waveform. The 13 ns acquisition time to 0.1% accuracy establishes a short aperture, 250 MHz tracking bandwidth accommodates fast-changing inputs, and the 100 pF load capability reduces sensitivity to capacitive loading. According to the Analog Devices AD9100 datasheet, hold-mode distortion below 83 dBfs is maintained at 30 MSPS for analog inputs up to 12 MHz. A robust implementation requires regulated supplies, local decoupling, low-inductance signal paths, and clock distribution whose jitter does not overwhelm the device's less-than-1-ps aperture-jitter capability.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ AD9100JD — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە |
|---|---|
| Package | 20-lead side-brazed skinny DIP ceramic package |
| Brand | Analog Devices |
| Product Type | Monolithic track-and-hold amplifier |
| Acquisition Time to 0.1% Accuracy | 13 ns |
| Acquisition Time to 0.01% Accuracy | 16 ns |
| Maximum Sampling Rate | 30 MSPS |
| Tracking Bandwidth | 250 MHz |
| Aperture Jitter | Less than 1 ps |
| Hold-Mode Distortion at 12 MHz and 30 MSPS | Less than 83 dBfs |
| Maximum Drive Capacitance | 100 pF |
جیاکەرەوە سەرەکییەکان
- Very short acquisition interval (بەراورد بەGeneral-purpose sample-and-hold amplifiers)
- Low sampling-aperture uncertainty (بەراورد بەConventional laboratory sample-and-hold stages)
- High-speed tracking with strong isolation (بەراورد بەGeneral-purpose buffer-based acquisition stages)
- Capacitive-load tolerance (بەراورد بەLower-drive sample-and-hold amplifiers)
تێبینییەکانی دیزاین
Keep the sampling clock physically separate from the analog input, hold output, and reference pins. Route high-speed tracks as short and direct as practical, maintain a continuous return path, and avoid routing clock signals beneath sensitive analog nodes. The AD9100's custom package reduces package parasitics, but board-level coupling can still degrade the measured hold-mode behavior. Use the pin-description table and recommended application arrangement in the Analog Devices AD9100 datasheet when assigning the layout.
Treat the sampling clock as a precision timing signal because the AD9100 specifies less than 1 ps aperture jitter. Use short clock traces, a low-impedance driver, and a quiet return path, and avoid unnecessary switches or long stubs in the clock network. Separately evaluate total timing uncertainty, including the clock generator, distribution network, board skew, and input slew rate; the component's aperture-jitter figure alone does not establish the timing accuracy of the complete instrument.
Do not assume that any 20-pin sample-and-hold amplifier is a drop-in replacement for the AD9100JD. A valid replacement must reproduce the exact terminal assignments and side-brazed package geometry while meeting the 13 ns acquisition, 250 MHz tracking bandwidth, less-than-1-ps aperture jitter, and load requirements. Check the manufacturer pin-description table, package drawing, and application circuit before approving a substitute or changing the sourcing suffix.
Follow the manufacturer's recommended supply and decoupling arrangement in the AD9100 datasheet, placing bypass connections so that high-current return paths do not share impedance with sensitive analog nodes. Confirm the exact pin voltages against the electrical-characteristics table before applying power. Stable reference and supply conditions are particularly important because acquisition-time and distortion measurements can be influenced by reference or supply noise even when the sample-and-hold timing is correct.
زانیاری پابەندبوون
The Analog Devices product material identifies commercial, industrial, and military temperature grades and states that factory consultation is required for 883-qualified devices. It does not state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status.