INA143UA - High-Speed Precision Difference Amplifier | Texas Instruments
MPN: INA143UA ✓ چالاکINA143UA گشتی
A difference amplifier measures the voltage difference between two input signals while rejecting common-mode voltage. The INA143UA belongs to the instrumentation-amplifier and precision-amplifier hierarchy: it uses an internal differential amplifier to convert a small difference between input voltages into an amplified output. Its selectable gain supports applications where either a large differential signal must be attenuated or a small signal must be amplified without excessive common-mode error.
The main performance characteristics include a 5 V/us slew rate, 250 uV offset, and 150 kHz bandwidth. The INA143UA is specified for a single supply up to 36 V or a dual supply of plus or minus 18 V, according to the manufacturer product information. Its 80 dB common-mode rejection helps preserve signal integrity when both input terminals experience large common-mode signals.
The INA143UA is suited to current sensing, bridge-sensor interfaces, industrial measurement, audio instrumentation, and precision signal conditioning. Its gain options allow the same device family to serve attenuation, gain-10, and gain-0.1 signal paths. The reference terminal provides a way to establish the output reference point in single-supply systems, while dual-supply operation permits bipolar output around ground.
When designing around the INA143UA, verify input and output voltage limits, common-mode range, supply configuration, and stability requirements against the manufacturer datasheet. Keep sensitive input and reference connections short, provide local supply bypassing, and route high-current returns away from the amplifier ground. Input and output filtering should be selected carefully because excessive capacitance can affect bandwidth or stability.
This page consolidates the manufacturer product information, package details, verified source links, drop-in alternatives, comparison fields, and practical design guidance for engineers evaluating the INA143UA in precision analog signal chains.
جێگرەوەکانی جێگۆڕکێ بۆ INA143UA — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ INA143UA (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Operating Temperature Range, Package, Product Type, Slew Rate, Common-Mode Rejection Ratio.
INA143U
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →INA143UAG4
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
INA143UA/2K5
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →INA132U/2K5
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →AD8278ARZ
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
INA143UA زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| Device Type | High-speed precision difference amplifier |
| Number of Circuits | 1 circuit |
| Slew Rate | 5 V/us |
| Offset Voltage | 250 uV |
| Gain Options | G = 10 or G = 0.1 |
| Bandwidth | 150 kHz |
| Common-Mode Rejection Ratio | 80 dB |
| Maximum Supply Voltage | 36 V |
| Dual Supply Range | plus or minus 18 V |
| مەودای پلەی گەرمیی کارکردن | -40 C to +85 C |
| پاکێج | 8-pin SOIC |
| Package Type | SOIC-8 |
| جۆری دامەزراندن | Surface mount |
| Input Configuration | Differential input |
| ڕێکخستنی دەرچوون | Single-ended output |
| Reference Terminal | Available for output-reference configuration |
ڕێکخستنی پینی INA143UA
| پین 1 | NC — Not connected |
| پین 2 | -IN — Inverting input |
| پین 3 | +IN — Non-inverting input |
| پین 4 | V- — Negative supply |
| پین 5 | REF — Reference input |
| پین 6 | OUT — Amplifier output |
| پین 7 | V+ — Positive supply |
| پین 8 | NC — Not connected |
بەکارهێنانە باوەکان
INA143UA گونجاوە بۆ 6 بەکارھێنانs: Bridge Sensor Signal Conditioning, Shunt Current Sensing, Industrial Process Measurement, Audio Instrumentation, Precision ADC Front End, Battery and Power-System Monitoring.
Bridge Sensor Signal Conditioning
The INA143UA is appropriate for conditioning Wheatstone bridge outputs where the useful signal is a small differential voltage superimposed on a larger common-mode level. Its selectable gain of 10 or 0.1 allows the circuit to either amplify a small sensor output or attenuate a larger differential signal. The 80 dB common-mode rejection helps suppress voltage shared by both bridge nodes, while the 5 V/us slew rate provides useful response for changing sensor signals. Confirm bridge excitation voltage, input common-mode range, output swing, and filter stability against the manufacturer datasheet.
پێشنیارکراو
Shunt Current Sensing
The INA143UA can measure the differential voltage generated across a current-sense shunt when both sensing nodes remain within its input and output limits. Differential sensing rejects common supply and ground disturbances more effectively than a single-ended amplifier, and the 250 uV offset specification is important when resolving small shunt voltages. The 150 kHz bandwidth and 5 V/us slew rate support fast current transients, but layout must keep the Kelvin sense traces away from power-current paths. Verify the shunt common-mode voltage before applying the device in high-side sensing.
پێشنیارکراو
Industrial Process Measurement
The INA143UA is suitable for industrial process-measurement interfaces that combine a sensor-generated differential signal with substantial common-mode voltage. Its selectable gain reduces the need to change amplifier types when signal magnitudes vary, and its common-mode rejection helps maintain measurement integrity in systems with switching converters or other noisy equipment. The 8-pin SOIC package supports conventional surface-mount assembly, while the 5 V/us slew rate allows the output to follow moderate sensor changes. Confirm the industrial temperature range and isolation or protection requirements for the final signal chain.
پێشنیارکراو
Audio Instrumentation
The INA143UA can amplify balanced audio or instrumentation signals when differential rejection and speed are more important than simply maximizing audio bandwidth. The gain-0.1 configuration supports attenuation in balanced signal paths, while gain 10 increases small differential outputs. Its 250 uV offset specification helps preserve low-level signal integrity, and the 5 V/us slew rate produces a clean response to moderate transient content. For audio equipment, check the output swing, reference configuration, supply noise, and stability requirements directly in the manufacturer datasheet.
پێشنیارکراو
Precision ADC Front End
The INA143UA is useful ahead of a precision ADC when the source is differential and the ADC requires amplification or attenuation close to the signal source. The amplifier's selectable gains permit a design to normalize different sensor ranges without changing the ADC reference. Its 80 dB common-mode rejection reduces errors from shared input voltage, and the 5 V/us slew rate helps drive the ADC input through settling periods. The designer should verify ADC acquisition timing, input capacitance, output settling, and whether the selected gain introduces excessive noise or bandwidth limits.
پێشنیارکراو
Battery and Power-System Monitoring
The INA143UA can monitor differential voltage in power systems where the measured signal is isolated from a changing common-mode level. The gain-0.1 option can reduce larger differential voltages, while gain 10 can improve resolution for small sensed changes. The 5 V/us slew rate supports rapid supply changes and the 250 uV offset helps define the low-level measurement floor. In battery systems, confirm the maximum input voltage, ground-reference arrangement, and protection requirements; the device must not be exposed beyond the datasheet limits.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ INA143UA — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | INA143U | INA143UAG4 | INA132U/2K5 | AD8278ARZ |
|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices |
| Package | SOIC-8 | SOIC-8 | SOIC-8 | SOIC-8 | SOIC-8 |
| Device Type | Difference amplifier | Difference amplifier | Difference amplifier | Instrumentation amplifier | Difference amplifier |
جیاکەرەوە سەرەکییەکان
- High-speed precision signal conditioning (بەراورد بەAD8278ARZ)
- Selectable attenuation and amplification (بەراورد بەINA132U/2K5)
- Closest identified same-family substitution (بەراورد بەINA143U)
- Common-mode rejection for measurement systems (بەراورد بەAD8278ARZ)
تێبینییەکانی دیزاین
Route the two differential input traces as a matched, closely coupled pair and keep them short. Connect shunt Kelvin traces directly to the sense resistor pads rather than sharing copper with the high-current path. Place the input protection, filtering, and gain-setting components close to the INA143UA so that parasitic resistance and capacitance do not unbalance the differential signal.
Place the supply-bypass capacitors close to the INA143UA supply pins and provide a low-impedance return from the device to the measurement ground. If the amplifier is used with a dual supply, define the reference point carefully; if it is used with a single supply, verify the REF connection and output swing. Confirm the maximum supply voltage of 36 V and the input common-mode limits before energizing the circuit.
Do not assume that matching the SOIC-8 footprint guarantees functional interchangeability. INA143 family variants may differ in gain implementation, orderable suffix, temperature grade, or packaging, while AD8278ARZ may have different input, output, bandwidth, and common-mode characteristics. Compare the complete pin description and electrical tables before approving a substitute.
The INA143UA provides 150 kHz bandwidth and a 5 V/us slew rate, so the complete signal path must be considered when setting input filters and ADC drive requirements. Excessive capacitance at the inputs or output can alter settling behavior or stability. Use the manufacturer application guidance and datasheet test conditions when selecting external capacitors or adding gain stages.
زانیاری پابەندبوون
No explicit compliance statements were identified in the verified source snippets. The INA143UA is listed as active in the TI product information.