INA2141UA/1K - Dual 10/100 Gain Instrumentation Amplifier | TI
MPN: INA2141UA/1K ✓ چالاکINA2141UA/1K گشتی
An instrumentation amplifier is a precision analog amplifier designed to measure small differential signals while rejecting large common-mode voltages. The INA2141 belongs to the instrumentation amplifier hierarchy within operational amplifiers and amplifier ICs. Its two internal amplifiers, laser-trimmed gain-setting networks, and internal input protection support accurate current sensing without requiring external gain-setting resistors.
The INA2141 offers two gain options established through simple pin connections, allowing a gain of 10 or 100 V/V. Maximum input protection extends to ±40 V, while the operating supply range reaches ±18 V. These characteristics make it useful when sensing small voltage drops across shunt resistors in systems where the common-mode voltage can vary substantially.
The device is trimmed for low offset voltage, low temperature drift, and accurate gain. Common-mode rejection of 117 dB minimum at gain 100 helps preserve measurement accuracy when the shunt voltage is small relative to the surrounding signal. The 16-pin SOIC package also provides separate channels, allowing one part to serve two independent analog measurements.
Typical uses include high-side current sensing, power-supply monitoring, battery-current measurement, motor-control feedback, and precision analog signal acquisition. The dual configuration is particularly useful when a system must monitor two currents with consistent gain, bandwidth, and offset performance.
Designers should maintain adequate supply headroom, observe the common-mode input range, and verify operation across the complete ±18 V supply capability. The manufacturer datasheet pin-description and electrical-characteristics tables should govern PCB implementation, input filtering, bypass-capacitor placement, and any protection network connected to the inputs.
This product record combines the manufacturer’s device description with package, ordering, specification, and practical design information. It also identifies the absence of a verified drop-in replacement and provides guidance on when the INA2141 is preferable to functionally similar instrumentation amplifiers with different pinouts or gain-setting methods.
جێگرەوەکانی جێگۆڕکێ بۆ INA2141UA/1K — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
هیچ جێگرەوەی ڕاستەوخۆ بۆ ئەم بەرهەمە بەردەست نییە.
داوای جێگرەوەکان بکەINA2141UA/1K زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| Number of Channels | 2 channels |
| Architecture | Dual instrumentation amplifier |
| Selectable Gain | 10 V/V or 100 V/V |
| Maximum Offset Voltage | 50 µV |
| Maximum Offset Drift | 0.5 µV/°C |
| Maximum Gain Error | ±0.05% |
| Maximum Input Bias Current | 5 nA |
| Minimum Common-Mode Rejection | 117 dB at gain 100 |
| Input Protection Range | ±40 V |
| Maximum Supply Voltage | ±18 V |
| Minimum Supply Voltage | ±2.25 V |
| مەودای پلەی گەرمیی کارکردن | -40 °C to +85 °C |
| پاکێج | 16-pin SOIC (DW) |
| جۆری دامەزراندن | Surface mount |
| دۆخی RoHS | Compliant |
| REACH Status | Compliant |
| Gain-Setting Method | Pin connection; no external gain-setting resistor |
| Trim Method | Laser trimmed |
ڕێنمایی ڕێکخستنی پینی INA2141UA/1K 16-pin soic (dw)
ڕێکخستنی پین بۆ INA2141UA/1K (پاکێجی 16-pin soic (dw)). ئەم پێکھاتە ئەنالۆگە پینی چوونەژوورەوە، دەرچوون و دابینکردنی وزەی ھەیە. سەرنج بدە بە داتاشیتی بەرھەمھێنەر بۆ ڕێکخستنەکانی پینی لادانی ئۆفسێت، قەرەبووکردنەوە و چالاککردن. گونجاوە بۆ ڕێکخستنی ئیشارەت و خولەکانی بەرزکەرەوە.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ INA2141UA/1K.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
INA2141UA/1K گونجاوە بۆ 6 بەکارھێنانs: High-Side DC Current Sensing, Power-Supply Load Monitoring, Battery Pack Current Monitoring, Motor-Control Feedback Sensing, Precision Analog Signal Acquisition, Industrial Process Measurement.
High-Side DC Current Sensing
The INA2141UA/1K fits high-side current sensing because its selectable 10 or 100 V/V gains amplify the small differential voltage produced by a series shunt while its input protection extends to ±40 V. The manufacturer specifies 117 dB minimum common-mode rejection at gain 100, which helps suppress bus-related error when the shunt voltage is small. The two channels can monitor two independent current paths. Designers should verify the operating common-mode range at startup and fault conditions, keep shunt placement current continuous, and use the datasheet pin table when assigning the two amplifier channels.
Power-Supply Load Monitoring
For power-supply load monitoring, the INA2141UA/1K can measure the voltage drop across a low-ohm shunt without external gain-setting resistors. A gain of 10 V/V suits larger drops, while 100 V/V provides greater sensitivity for low-current measurements. Its maximum offset of 50 µV and drift of 0.5 µV/°C help maintain accuracy as operating conditions change. The ±18 V supply capability supports high-side rails, but input common-mode and supply headroom must be checked against the actual power stage. The dual configuration can monitor input and output loads concurrently.
Battery Pack Current Monitoring
The INA2141UA/1K is applicable to battery-pack monitoring when charge or discharge current must be measured across a shunt in the high-voltage path. Its fixed gains of 10 and 100 V/V simplify scaling to an analog-to-digital converter, and the low 5 nA maximum input bias current limits errors in high-impedance sensing arrangements. The ±40 V input protection rating supports specified overload conditions, while the manufacturer’s operating limits still govern normal use. Layout should minimize differential-loop area and place input filtering close to the amplifier to preserve measurement accuracy.
Motor-Control Feedback Sensing
The INA2141UA/1K can provide two independent feedback channels in motor-control and actuator systems, including return-path current measurement and supply-current monitoring. Its common-mode rejection of 117 dB minimum at gain 100 is valuable when switching-node voltage is much larger than the shunt differential. The 16-pin SOIC (DW) package supports conventional surface-mount assembly, while two independent amplifiers reduce component count compared with separate single-channel devices. Engineers must confirm that transient voltages remain within the input and supply ratings and that ground currents do not create errors in the shunt reference.
Precision Analog Signal Acquisition
The INA2141UA/1K is suitable for low-level differential acquisition when the signal is small relative to a varying common-mode voltage. Its laser-trimmed gain networks deliver accurate 10 or 100 V/V scaling without external resistor tolerance, and the maximum gain error of ±0.05% supports repeatable measurement chains. The two channels allow simultaneous acquisition or correlated measurements. Input filtering, bypass capacitors, grounding, and connector protection should be designed around the bandwidth and noise requirements of the source because the amplifier does not replace signal-conditioning filtering.
Industrial Process Measurement
The INA2141UA/1K can serve industrial process-measurement front ends when a sensor or shunt produces a small differential voltage in the presence of a larger process common-mode voltage. The dual-channel format supports two measurement loops, and the fixed-gain architecture reduces calibration and resistor-selection complexity. Its operating temperature range of -40 °C to +85 °C covers many industrial environments, while internal input protection helps manage specified overvoltage conditions. Final qualification should include surge, grounding, isolation, and calibration requirements specific to the measurement system.
داتای سەرچاوەی ئەندازیاری بۆ INA2141UA/1K — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە |
|---|---|
| Brand | Texas Instruments |
| Package | 16-pin SOIC (DW) |
| Number of Channels | 2 |
| Selectable Gain | 10 V/V or 100 V/V |
| Maximum Offset Voltage | 50 µV |
| Maximum Offset Drift | 0.5 µV/°C |
| Maximum Gain Error | ±0.05% |
| Common-Mode Rejection | 117 dB minimum at gain 100 |
| Maximum Input Bias Current | 5 nA |
| Input Protection | ±40 V |
| Supply Voltage Range | ±2.25 V to ±18 V |
| Operating Temperature Range | -40 °C to +85 °C |
جیاکەرەوە سەرەکییەکان
- Dual fixed-gain channels without external gain resistors (بەراورد بەAD8226)
- Input protection specified to ±40 V (بەراورد بەAD8226)
- High common-mode rejection at maximum gain (بەراورد بەINA219AID)
تێبینییەکانی دیزاین
Route the two inputs of each differential channel as a tight, symmetric pair and place any input-series resistors close to the amplifier pins. Keep the shunt return and signal ground paths separate from high-current switching paths so that voltage drops in copper and ground planes do not add to the measured differential signal. This is especially important at gain 100, where 50 µV of offset corresponds to only 500 µV at the amplifier input.
Use the minimum supply headroom that meets the system’s load and transient requirements while remaining inside the ±2.25 V to ±18 V operating range. Place the manufacturer-recommended bypass capacitors at the supply pins and observe their voltage and temperature characteristics. Input protection to ±40 V does not authorize operation outside the supply ratings, so fault-energy and power-sequencing analysis must be performed separately.
Do not infer gain from the nominal 10 or 100 V/V setting without checking the manufacturer’s pin-connection table and the actual common-mode range. Verify whether the selected operating point requires gain 10 or gain 100, and account for the corresponding offset, bias-current, and common-mode-rejection limits. Also avoid treating a functionally similar amplifier with a different pinout or external gain resistor as a direct replacement.
Choose input-filter component values from the signal bandwidth rather than adding capacitance indiscriminately. Excessive input capacitance can create phase shift between the two amplifier inputs and degrade differential signal accuracy. For high-frequency shunt measurements, maintain symmetrical filtering, confirm differential-versus-common-mode settling behavior with the selected gain, and keep the shunt itself electrically short to reduce parasitic inductance and resistance.
زانیاری پابەندبوون
The product record identifies EU RoHS and REACH compliance. No automotive qualification, lead-free status, halogen-free status, or conflict-minerals declaration is established for this ordering code.