ISO1050DW - 5V Isolated CAN Transceiver | Texas Instruments
MPN: ISO1050DW ✓ چالاکISO1050DW گشتی
An isolated CAN transceiver is a network interface device that connects a CAN bus to a host controller while preventing high-voltage and ground-potential differences from propagating between the two systems. Within the signal-chain hierarchy, it combines a CAN physical-layer transceiver, a digital isolator, and logic-side interfaces. This galvanic isolation improves fault containment and lets equipment connected to a CAN bus operate safely when the bus and controller grounds are at different potentials.
Key electrical features include 5000 VRMS reinforced isolation for ISO1050DW, low loop delay of 150 ns typical, and transient-immunity capability of 50 kV/s typical. The logic-side and bus-side sections use separate supply domains, while failsafe outputs help define the state of the interface when the bus is inactive. The 16-SOIC package supports conventional surface-mount assembly and provides a clear path from the CAN input/output pins to the isolated logic-side TXD and RXD pins.
Technically, the ISO1050 integrates a CAN transceiver with reinforced silicon oxide isolation. The 74 ns propagation-delay specification is important for maintaining stable message timing, while the 150 ns typical loop-delay figure indicates how quickly a transition at TXD can appear at RXD through the device. Its isolation barrier separates the logic input and output buffers from the CAN bus interface, allowing isolated power to be used on the controller side when required by the system architecture.
Typical uses include industrial automation equipment, building controls, robotics, electric-vehicle subsystems, and other CAN networks where ground-potential differences are possible. The device is particularly suitable when a robust 1 Mbps bus connection and 5000 VRMS separation are required in a compact 16-pin surface-mount package.
Designers should provide separate, properly decoupled supplies to the bus-side and logic-side power pins and connect the CAN transceiver portion to the bus reference ground. The isolation barrier does not replace proper high-voltage layout practices; creepage, clearance, surge protection, and the ratings of external components must follow the complete system isolation plan.
This page consolidates verified manufacturer and distributor information, explicit data gaps, sourcing considerations, and design guidance for engineers evaluating the ISO1050DW for isolated CAN links.
جێگرەوەکانی جێگۆڕکێ بۆ ISO1050DW — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ ISO1050DW (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Package.
هیچ جێگرەوەی ڕاستەوخۆ بۆ ئەم بەرهەمە بەردەست نییە.
داوای جێگرەوەکان بکەISO1050DW تایبەتمەندییەکان
| Product Type | Isolated CAN transceiver |
| CAN Standard | ISO11898-2 |
| Isolation Rating | 5000 VRMS |
| Insulation Material | Silicon oxide (SiO2) |
| Number of Channels | 2 |
| Propagation Delay Time | 74 ns |
| Typical Loop Delay | 150 ns |
| Transient Immunity | 50 kV/s typical |
| Maximum Supply Voltage | 5.5 V |
| Nominal Supply Voltage | 5 V |
| Maximum Data Rate | 1 Mbps |
| پاکێج | 16-SOIC (0.295 inch, 7.50 mm width) |
| Number of Terminals | 16 |
| جۆری دامەزراندن | Surface mount |
| Terminal Form | Gull wing |
| Failsafe Outputs | Supported |
ڕێنمایی ڕێکخستنی پینی ISO1050DW 16-soic (0.295 inch, 7.50 mm width)
ڕێکخستنی پین بۆ ISO1050DW (پاکێجی 16-soic (0.295 inch, 7.50 mm width)). ژمارەدانی پین، فەنکشنەکان و نەخشەکانی پەیوەندی لە داتاشیتی بەرھەمھێنەردا پێناسە کراون. سەرنجی بدە بۆ شوێنپێی ورد و ڕێنمایییەکانی لەحیمکردن.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ ISO1050DW.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
ISO1050DW گونجاوە بۆ 6 بەکارھێنانs: Industrial Automation Controllers, Robotics and Motion Systems, Building Control Networks, Electric Vehicle Subsystems, Medical and Diagnostic Equipment, Telecommunications and Data Equipment.
Industrial Automation Controllers
The ISO1050DW fits industrial automation controllers that connect a local controller to a CAN bus through a galvanic barrier. Its 5000 VRMS isolation, 1 Mbps maximum data rate, 74 ns propagation delay, and 150 ns typical loop delay support responsive communication while separating the bus domain from sensitive logic. The device is placed between the controller TXD and RXD signals and the CANH/CANL bus interface, with separate supply domains and local decoupling. Designers should add appropriately rated transient protection and maintain the required isolation clearance and creepage on the PCB.
پێشنیارکراو
Robotics and Motion Systems
ISO1050DW is suitable for robot controllers and motion systems where actuator buses, safety circuits, and control electronics can develop different ground potentials. The silicon oxide isolation barrier supports up to 5000 VRMS for ISO1050DW, while the 1 Mbps CAN capability and 74 ns propagation delay are appropriate for command and status traffic. The transceiver operates between host-controller logic and CAN bus pins, reducing the need for a shared high-voltage ground. Engineers still need to coordinate bus termination, surge protection, isolated power, and enclosure-level isolation requirements.
پێشنیارکراو
Building Control Networks
The ISO1050DW can connect building-control equipment to a CAN-based field network when controllers and building wiring are separated by substantial potential differences. Its 5000 VRMS isolation rating and 1 Mbps maximum data rate fit demanding building-automation links, and the 74 ns propagation delay supports timely message handling. In implementation, the device separates the logic TXD/RXD side from the CANH/CANL side, allowing each domain to use its own supply reference. The design must include correct bus stubs, termination, surge suppression, and compliant separation distances.
پێشنیارکراو
Electric Vehicle Subsystems
ISO1050DW can be used in electric-vehicle subsystems where a 1 Mbps CAN link connects control electronics to equipment operating at a different ground potential. The 5000 VRMS isolation barrier helps contain faults and electrical differences, while the 150 ns typical loop delay and 74 ns propagation delay support responsive control traffic. The transceiver handles the CANH/CANL physical layer and provides isolated TXD/RXD logic connections to the host. Compliance with vehicle-level EMC, functional-safety, and environmental requirements must be established separately from component selection.
پێشنیارکراو
Medical and Diagnostic Equipment
ISO1050DW is applicable to medical and diagnostic equipment that uses CAN communication between isolated subsystems, provided the complete design satisfies the relevant medical electrical-safety requirements. Its 5000 VRMS isolation, 1 Mbps maximum data rate, 74 ns propagation delay, and failsafe outputs provide useful interface characteristics for separating control and bus domains. The component does not by itself establish medical certification. Designers must evaluate the full isolation network, leakage, clearance, fault behavior, external power, and applicable equipment standard.
پێشنیارکراو
Telecommunications and Data Equipment
ISO1050DW can support isolated CAN links in telecommunications and data equipment where backplane circuitry, external cabling, and system grounds create potential isolation concerns. The 5000 VRMS barrier and typical 50 kV/s transient immunity complement a maximum 1 Mbps CAN data rate, while the 74 ns propagation delay provides deterministic interface timing. The part is placed at the boundary between controller logic and the CAN bus, with separately filtered supplies on each side. Layout should preserve isolation boundaries and avoid placing disruptive switching nodes or unprotected copper within those boundaries.
پێشنیارکراو
داتای سەرچاوەی ئەندازیاری بۆ ISO1050DW — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە |
|---|---|
| Package | 16-SOIC (0.295 inch, 7.50 mm width) |
| Brand | Texas Instruments |
| Isolation Rating | 5000 VRMS |
| Maximum Data Rate | 1 Mbps |
| Propagation Delay | 74 ns |
| Typical Loop Delay | 150 ns |
| Maximum Supply Voltage | 5.5 V |
| Transient Immunity | 50 kV/s typical |
| Number of Channels | 2 |
| CAN Standard | ISO11898-2 |
جیاکەرەوە سەرەکییەکان
- Higher verified isolation rating within the ISO1050 family (بەراورد بەISO1050DUB)
- No direct drop-in substitution due to incompatible pin assignments (بەراورد بەISO1042)
- Fast isolated CAN interface for control and monitoring networks (بەراورد بەISO1050DWR)
تێبینییەکانی دیزاین
Preserve the isolation boundary across the entire PCB, not only beneath ISO1050DW. Keep the logic-side and bus-side ground planes, copper pours, test points, and external components separated according to the required working voltage and pollution degree. Avoid placing high-voltage or fast-switching copper under the device where creepage and capacitance could reduce isolation performance. The 5000 VRMS device rating does not determine the layout spacing by itself; use the complete system insulation requirements and the manufacturer guidance.
Provide independently referenced supplies to the logic-side and bus-side sections, each within the 5.5 V maximum verified limit. Place local high-frequency bypass capacitors at the relevant supply and ground pins and keep their return paths short. The isolated power source must have adequate isolation and capacitance characteristics for the operating frequency. Confirm startup, shutdown, bus-active, and bus-inactive behavior because correct voltage sequencing and stable references are essential to predictable CAN communication.
Do not substitute ISO1042 for ISO1050DW without a PCB redesign. Texas Instruments support information identifies swapped RXD and TXD assignments on pins 2 and 3 for the compared SOIC-8 versions, and the package sizes differ. ISO1050DUB also has a lower verified isolation rating of 2500 VRMS compared with 5000 VRMS for ISO1050DW. Check the complete ordering table, isolation class, pin assignments, and supply domains before approving any alternate part.
Implement the CAN bus protection and termination strategy as part of the interface rather than relying solely on the transceiver. Use the appropriate bus termination at the physical endpoints, minimize stub length, and select surge-protection devices whose capacitance and clamp behavior are compatible with the 1 Mbps maximum data rate. Keep protection current away from the isolation barrier and verify it for the required industrial transient environment. The verified 50 kV/s typical transient-immunity figure describes the device, not the complete protected system.
زانیاری پابەندبوون
The verified snippets mention RoHS information but do not provide an explicit compliance value. No REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status was provided for ISO1050DW; these fields are therefore left unknown rather than inferred.