MAX3485EESA+ 3.3V 12Mbps RS-485/RS-422 Transceiver
MPN: MAX3485EESA+ ✓ چالاکMAX3485EESA+ گشتی
An RS-485/RS-422 transceiver is an interface IC that converts logic-level digital signals into balanced differential bus voltages and converts received differential voltages back into digital logic levels. This device belongs to the transceiver hierarchy within interface ICs, where differential signaling improves noise immunity, reduces ground-potential sensitivity, and supports communication across factory, industrial, and instrumentation environments.
Key features include a 3.3V supply, operation to 12Mbps, slew-rate-limited true RS-485/RS-422 signaling, and enhanced ESD protection. Transmitter outputs and receiver inputs are protected to ±15kV under the IEC 1000-4-2 air-gap discharge test, ±8kV under the IEC 1000-4-2 contact-discharge test, and ±15kV under the Human Body Model. The integrated protection reduces the need for separate bus-line protection in exposed industrial interfaces.
The half-duplex architecture lets the transmitter and receiver share a differential pair through direction-control logic. The MAX3485EESA+ is designed for both RS-485 multidrop networks and point-to-point RS-422 links. Its 12Mbps capability accommodates high-rate industrial data paths while its limited slew rate reduces unwanted edge energy and electromagnetic interference compared with an unrestricted high-speed driver.
Typical applications include industrial automation controllers, RS-485 communication modules, data-acquisition equipment, building-control interfaces, instrumentation, and point-to-point RS-422 links. Because the bus operates at 3.3V, it can interface directly with 3.3V logic without a separate level-shifting stage when the connected transceiver and controller use compatible thresholds.
PCB design should preserve the compact 8-pin SOIC footprint and place protection, bypass, and termination components close to the relevant pins. Check the manufacturer pin-description table before assigning the driver-enable and receiver-enable functions, and verify whether the selected bus topology requires termination, biasing, or fail-safe bias resistors.
This page combines manufacturer specifications, package information, interface-design guidance, comparison data, and drop-in replacement options to support faster component selection, PCB planning, and robust RS-485/RS-422 implementation.
جێگرەوەکانی جێگۆڕکێ بۆ MAX3485EESA+ — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ MAX3485EESA+ (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Product Type, Package, Supply Voltage, Maximum Data Rate, Number of Drivers.
MAX3490EESA+
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →MAX3485ECSA+
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →MAX3486CSA
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
ST3485EBDR
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
SP3485CN-L/TR
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →MAX3485EESA+ تایبەتمەندییەکان
| Product Type | 1/1 half-duplex RS-485/RS-422 transceiver |
| ڤۆڵتیەی دابینکردن | 3.3V |
| Guaranteed Maximum Data Rate | 12Mbps |
| Number of Drivers | 1 driver |
| Number of Receivers | 1 receiver |
| Supported Standards | RS-485 and RS-422 |
| Driver Configuration | Slew-rate-limited true RS-485/RS-422 |
| ESD Protection, Air-Gap Discharge | ±15kV per IEC 1000-4-2 |
| ESD Protection, Contact Discharge | ±8kV per IEC 1000-4-2 |
| ESD Protection, Human Body Model | ±15kV |
| پاکێج | 8-pin SOIC |
| جۆری دامەزراندن | Surface mount |
| Operating Configuration | Half-duplex |
| Production Status | Production |
ڕێنمایی ڕێکخستنی پینی MAX3485EESA+ 8-pin soic
ڕێکخستنی پین بۆ MAX3485EESA+ (پاکێجی 8-pin soic). ژمارەدانی پین، فەنکشنەکان و نەخشەکانی پەیوەندی لە داتاشیتی بەرھەمھێنەردا پێناسە کراون. سەرنجی بدە بۆ شوێنپێی ورد و ڕێنمایییەکانی لەحیمکردن.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ MAX3485EESA+.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
MAX3485EESA+ گونجاوە بۆ 6 بەکارھێنانs: Industrial Automation Bus Interface, Point-to-Point RS-422 Link, Data Acquisition Equipment, Building Control Network, Instrumentation and Test Systems, RS-485 Communication Module.
Industrial Automation Bus Interface
The MAX3485EESA+ fits industrial automation controllers that communicate over an RS-485 multidrop bus at up to 12Mbps. Its 3.3V supply allows direct connection to compatible 3.3V embedded controllers, while the one-driver, one-receiver arrangement supports half-duplex operation. The slew-rate-limited true RS-485/RS-422 outputs help reduce high-frequency edge energy and EMI. Integrated protection of ±15kV air-gap, ±8kV contact, and ±15kV Human Body Model levels is valuable on factory equipment where cables and connectors may be exposed to electrostatic discharge. Bus topology, grounding, termination, and enable timing must still be engineered for the installation.
پێشنیارکراو
Point-to-Point RS-422 Link
The MAX3485EESA+ is appropriate for a point-to-point RS-422 connection requiring 3.3V logic and data transfer up to 12Mbps. Its differential transmitter and receiver provide noise-resistant signaling over longer interconnections than a single-ended interface, while the half-duplex arrangement can be controlled through the device enable inputs. The 8-pin SOIC package keeps the circuit compact and supports automated board assembly. For reliable operation, follow the manufacturer recommended termination and enable timing, maintain a consistent ground reference where appropriate, and validate the complete cable and connector path for the intended data rate.
پێشنیارکراو
Data Acquisition Equipment
The MAX3485EESA+ can connect laboratory and industrial data-acquisition equipment to an RS-485 or RS-422 control network. A 12Mbps maximum rate supports high-volume command and measurement traffic, while differential signaling improves robustness in environments with motors, switching supplies, and long cable runs. The 3.3V transceiver operates from the same voltage class as many modern mixed-signal controllers, reducing system complexity. Use the slew-rate-limited outputs for EMC control, place bypass capacitance close to the device, and select termination at physical endpoints rather than at every node in a multidrop bus.
پێشنیارکراو
Building Control Network
The MAX3485EESA+ supports compact building-control controllers, HVAC interfaces, sensors, and supervisory modules that use RS-485 or RS-422 differential buses. Its compact 8-pin SOIC footprint allows it to fit into distributed control panels, while the 3.3V supply suits modern low-voltage embedded systems. The integrated ESD protection adds useful robustness in occupied buildings where cables may be connected and disconnected during maintenance. Long building runs may require lower signaling rates or greater termination care than the 12Mbps device maximum, so validate cable length, topology, common-mode limits, and grounding for each installation.
پێشنیارکراو
Instrumentation and Test Systems
The MAX3485EESA+ is suited to remote instrumentation and test systems that exchange commands and measurements over a differential bus. A guaranteed 12Mbps data-rate ceiling allows the interface to support fast status polling, while the slew-limited driver reduces unwanted high-frequency emissions. The receiver and transmitter share a half-duplex interface, so the host controller must manage bus direction and account for enable propagation delay. For bench systems connected to long leads, add suitable connectors and protection, keep return paths controlled, and verify operation with the actual cable and termination configuration.
پێشنیارکراو
RS-485 Communication Module
The MAX3485EESA+ can form the core of a compact 3.3V RS-485 communication module for gateways, controllers, and field equipment. Its one-driver, one-receiver implementation supports half-duplex multidrop networks, and the 12Mbps rating covers fast local buses. Enhanced ESD protection on the transmitter outputs and receiver inputs improves resilience when users connect field cables. A production design should include local supply decoupling, optional galvanic isolation for long or ground-potential-separated links, termination at the bus ends, and biasing that remains effective when all transceivers are disabled.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ MAX3485EESA+ — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | MAX3490EESA+ | MAX3485ECSA+ | MAX3486CSA | ST3485EBDR | SP3485CN-L/TR |
|---|---|---|---|---|---|---|
| Package | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | STMicroelectronics | Microchip Technology |
| Product Type | 1/1 half-duplex RS-485/RS-422 transceiver | RS-485/RS-422 transceiver | RS-485/RS-422 transceiver | RS-485/RS-422 transceiver | 1/1 half-duplex RS-485/RS-422 transceiver | RS-485/RS-422 transceiver |
جیاکەرەوە سەرەکییەکان
- High-speed differential communication in a compact package (بەراورد بەST3485EBDR)
- Enhanced ESD coverage on bus-facing pins (بەراورد بەMAX3490EESA+)
- Slew-limited true RS-485/RS-422 output behavior (بەراورد بەMAX3486CSA)
تێبینییەکانی دیزاین
Place the transceiver close to the board connector so the balanced traces between the MAX3485EESA+ and the connector remain short and symmetrical. Route the differential pair as a coupled pair, avoid discontinuities and unnecessary stubs, and keep the ground reference continuous. This reduces radiated emissions and susceptibility to common-mode noise, particularly important when the 12Mbps data rate is used on long industrial cables.
Do not assume the MAX3485EESA+ receiver output can remain valid while the driver is enabled. In a half-duplex design, control driver-enable and receiver-enable functions so the transmitter is disabled during receive intervals. Verify enable polarity and propagation delay against the manufacturer timing tables; incorrect control sequencing can cause the local transmitter to fight the received bus signal.
The slew-rate-limited outputs are intended to reduce high-frequency edge energy, but correct bus implementation remains necessary. Place termination only at the physical ends of the bus, avoid excessive termination on long multidrop networks, and consider fail-safe biasing for an idle bus. External surge protection should be added when the connected cable is longer than the protected PCB area or exposed to lightning and industrial transients.
Use a short, low-inductance connection from the 3.3V supply to the transceiver and place the recommended bypass capacitor close to the device pins. Keep the return path beneath or adjacent to the interface traces where possible. Because the operating voltage is specifically 3.3V, verify that the complete module does not expose the transceiver pins to 5V signals or to supply transients above its absolute maximum rating.
زانیاری پابەندبوون
The manufacturer documentation identifies IEC 1000-4-2 air-gap and contact-discharge tests and the Human Body Model for ESD ratings. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status were not established from the available information.