OPA551UA - 60V High-Current Operational Amplifier | Texas Instruments
MPN: OPA551UA ✓ چالاکOPA551UA گشتی
An operational amplifier is a voltage-gain and signal-conditioning semiconductor that compares an inverting input with a non-inverting input and drives its output according to the feedback network. The OPA551 belongs to the operational-amplifier hierarchy, where its unusually high supply-voltage tolerance and output-current capability extend ordinary precision amplifier use into high-power industrial, audio, instrumentation, and motor-control systems.
The OPA551UA provides a wide supply range up to ±30 V, continuous output current up to 200 mA, and typical current capability of 380 mA. Its input noise density is 14 nV/√Hz, while unity-gain stability permits operation without a minimum gain setting. Output swing remains approximately 2 V from the supply rails, providing useful headroom for driving external transistors and other high-current loads.
The device also includes thermal shutdown, output-current limiting, and a thermal-shutdown indicator. Its 15 V/µs slew rate supports faster large-signal transitions than a general-purpose low-power amplifier, while the 3 MHz bandwidth is sufficient for audio, control, and instrumentation signals. The high-current output stage should still be evaluated against the thermal limits of the 8-pin SOIC package and the surrounding copper area.
Typical uses include audio power-buffer stages, high-voltage current-feedback circuits, industrial sensor interfaces, laboratory output stages, and power-converter control loops. Designers should also check input common-mode range, output swing, supply headroom, and thermal rise before fixing component values or external load limits.
For a stable implementation, use feedback that preserves unity-gain stability, place input and output components close to the device, and provide local supply bypassing. The exposed requirements for current and temperature must be validated with the actual PCB layout rather than inferred from nominal output-current capability alone.
This page combines the OPA551UA's principal electrical characteristics with package guidance, application-oriented design notes, comparison criteria, and drop-in replacement constraints. It provides a practical engineering view for selecting and implementing this high-voltage, high-current operational amplifier.
جێگرەوەکانی جێگۆڕکێ بۆ OPA551UA — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ OPA551UA (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Amplifier Type, Package, Slew Rate.
OPA552UA
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →OPA551UA زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| Amplifier Type | Single operational amplifier |
| Maximum Supply Voltage | 60 V |
| Typical Supply Voltage Range | ±4 V to ±30 V |
| Typical Output Current | 380 mA |
| Continuous Output Current | 200 mA |
| Gain-Bandwidth Product | 3 MHz |
| Slew Rate | 15 V/µs |
| Input Noise Voltage Density | 14 nV/√Hz |
| Output Swing from Supply Rail | 2 V |
| Unity-Gain Stability | Yes |
| Protection Features | Thermal shutdown, output current limit, and thermal shutdown indicator |
| Number of Circuits | 1 circuit |
| پاکێج | 8-pin SOIC |
| جۆری دامەزراندن | Surface mount |
ڕێکخستنی پینی OPA551UA
| پین 1 | NC — Not connected |
| پین 2 | IN- — Inverting input |
| پین 3 | IN+ — Non-inverting input |
| پین 4 | V- — Negative supply connection |
| پین 5 | NC — Not connected |
| پین 6 | OUT — Output |
| پین 7 | V+ — Positive supply connection |
| پین 8 | NC — Not connected |
بەکارهێنانە باوەکان
OPA551UA گونجاوە بۆ 6 بەکارھێنانs: High-Current Audio Buffer, Industrial Sensor Signal Conditioning, Power Converter Control Loop, Laboratory Instrumentation Output, Motor and Solenoid Drive Interface, Telephony and Communication Interface.
High-Current Audio Buffer
The OPA551UA fits an audio power-buffer stage that must operate from a high-voltage rail while driving a lower-impedance load. Its 200 mA continuous output current and 380 mA typical current capability provide substantially more drive than ordinary small-signal operational amplifiers, while the 15 V/µs slew rate supports audio-rate transients. Place the amplifier in a unity-gain or inverting feedback configuration around the 3 MHz bandwidth region, and confirm that the required peak voltage remains within the approximately 2 V-from-rail output swing. The main trade-off is heat: verify dissipation from the actual rail-to-rail voltage and load current, because the SOIC outline must dissipate internal loss without exceeding its temperature limits.
پێشنیارکراو
Industrial Sensor Signal Conditioning
OPA551UA is appropriate for industrial sensor-conditioning paths where source impedance is low and the next stage requires more current than a conventional precision operational amplifier can provide. Its 14 nV/√Hz input noise density is useful for low-noise amplification, while unity-gain stability permits a straightforward feedback arrangement. The ±4 V to ±30 V supply capability also accommodates protected, high-voltage acquisition systems better than low-voltage instrumentation amplifiers. Keep the selected feedback network within the device's stable operating region, account for the input common-mode limits, and route the return current directly to the device ground to avoid converting sensor-loop current into measurement error.
پێشنیارکراو
Power Converter Control Loop
OPA551UA can serve as the error amplifier or transient driver in a high-voltage power-conversion control loop when the design requires stronger output-drive capability than a standard controller IC. Its 15 V/µs slew rate permits faster loop response than many low-power amplifiers, and the 200 mA continuous output-current rating can drive comparator, feedback, or gate-drive networks more effectively than a low-power device. Compensation must account for the 3 MHz gain-bandwidth product and the amplifier's output-current limits. Verify the common-mode range at the feedback node and confirm that startup, saturation recovery, and maximum supply conditions do not force the output into the approximately 2 V-from-rail region.
پێشنیارکراو
Laboratory Instrumentation Output
The OPA551UA is useful in a laboratory output stage that must drive a moderately low-impedance instrument while accepting high-voltage command signals. Its unity-gain stability supports direct buffer use, and the combination of 3 MHz bandwidth, 15 V/µs slew rate, and 14 nV/√Hz input noise provides a practical balance between response speed and signal integrity. A transimpedance or voltage-buffer configuration can be selected according to the source impedance and required transfer function. Because the package is an 8-pin SOIC rather than a high-power package, calculate junction temperature from the worst-case dissipation and maintain copper area around the leads. The output must also remain within 2 V of either supply rail at maximum command voltage.
پێشنیارکراو
Motor and Solenoid Drive Interface
OPA551UA can form the voltage-buffer or error-amplifier interface between a control signal and a high-current transistor stage. Its output-current capability is better matched to driving external power devices than a conventional low-power op amp, while the high-voltage operation permits use in elevated industrial supply systems. The OPA551 itself should not be treated as an unrestricted motor driver: use external transistors for the final load current and use the amplifier to control their drive. Select feedback values for the required closed-loop gain, preserve unity-gain stability where required, and include protection against transient overvoltage. Thermal calculations should include both quiescent dissipation and output-stage loss at the highest expected load current.
پێشنیارکراو
Telephony and Communication Interface
OPA551UA supports line-driver, microphone-interface, or communication-signal stages requiring a combination of high supply voltage and stronger output drive than a conventional low-voltage amplifier. The 3 MHz bandwidth covers voice-band and many wider communication signals, while the 15 V/µs slew rate reduces distortion on square or fast transient waveforms. The device's unity-gain stability is useful in buffer and low-noise feedback arrangements. Keep the loop compensation compatible with the closed-loop gain, avoid excessive capacitive loading directly at the output, and isolate sensitive input routing from the high-current output path. Confirm output-voltage headroom, load impedance, and thermal rise across the full communication-bus supply range before production release.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ OPA551UA — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | OPA552UA |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | 8-pin SOIC | 8-pin SOIC - same package |
| Maximum Supply Voltage | 60 V | 60 V |
| Continuous Output Current | 200 mA | 200 mA |
| Gain-Bandwidth Product | 3 MHz | 12 MHz |
| Slew Rate | 15 V/µs | 24 V/µs |
| Gain Stability | Unity-gain stable | Optimized for gains of 5 or greater |
جیاکەرەوە سەرەکییەکان
- Unity-gain operation is supported (بەراورد بەOPA552UA)
- Lower speed supports a different signal-integrity profile (بەراورد بەOPA552UA)
- High-current output supports stronger buffer loads (بەراورد بەOPA552UA)
تێبینییەکانی دیزاین
Estimated: calculate dissipation with P = (VIN - VOUT) × IOUT + VIN × IQ, using the maximum supply voltage, actual output voltage, and continuous load current. Add the result to the package's operating-temperature constraint. The 200 mA continuous rating cannot be used without thermal margin because the 8-pin SOIC package has limited heat-spreading area. Keep output current below the continuous rating during steady operation and verify the PCB copper area under worst-case ambient temperature.
Place local bypass capacitors close to the supply pins and connect their return current directly to the device ground. Keep the inverting-input and feedback traces short, particularly when the closed-loop gain is low and the circuit is sensitive to parasitic capacitance. Route the high-current output away from sensitive input nodes and use a ground plane that is not interrupted by output-current returns.
Do not interpret the 380 mA typical output-current figure as an unconditional continuous-load rating. Confirm the 200 mA continuous capability, output-voltage headroom, common-mode input range, and thermal shutdown behavior under the actual load. Output saturation is approximately 2 V from each rail, so a ±30 V supply does not provide a full ±30 V output swing.
Maintain a low-impedance path for both supply rails because high output current can produce supply disturbance that couples back into the signal path. Use separate input and output grounding paths where possible, avoid placing high-current return current beneath sensitive inputs, and verify the design with thermal and stability measurements. If driving a capacitive load, add an isolation resistor and check for stability at the resulting gain.
زانیاری پابەندبوون
The available product documentation does not explicitly state the individual RoHS, REACH, lead-free, halogen-free, or conflict-minerals status for OPA551UA.