SN75155P - RS-232 Line Driver and Receiver | Texas Instruments
MPN: SN75155P ✓ چالاکSN75155P گشتی
An RS-232 interface transceiver is a semiconductor device that converts logic-level signals into RS-232-compatible voltage levels and converts received RS-232 levels back into logic signals. In the interface hierarchy, the SN75155P belongs to the line-driver-and-receiver family, within transceivers, interface ICs, and integrated circuits. It is commonly placed between a host controller or UART and a DB-25 or equivalent RS-232 connector.
The key features of the SN75155P are its integrated driver and receiver, full RS-232 operation, response control for receiver-noise adjustment, and an 8-pin PDIP package. The response control input accepts a resistor, or a resistor and bias voltage, connected to ground to control receiver noise behavior. This makes the part useful in legacy data-communication equipment where one receiver serves a console, modem, or data-terminal connection.
Internally, the driver converts TTL/CMOS-level inputs into bipolar RS-232 signal levels, while the receiver converts a differential-looking RS-232 input into a logic-level output for the system controller. Because the driver and receiver operate in opposite directions, one SN75155P supports bidirectional communication when the driver output and receiver input are connected to separate interface signals. The manufacturer datasheet is the controlling reference for voltage thresholds, timing, and input-current limits.
Typical applications include serial console links, data-terminal equipment, legacy printer interfaces, industrial control panels, and RS-232 test equipment. The SN75155P is also appropriate where a controller requires a receive path with adjustable noise control rather than a modern multi-channel RS-232 transceiver.
When laying out an RS-232 design, place the transceiver close to the connector and keep the driver and receiver return paths routed away from sensitive analog inputs. Confirm the interface voltage thresholds, driver slew behavior, and response-control network against the manufacturer datasheet before releasing a production board.
This page consolidates the manufacturer product information, package and temperature data, interface standard, application context, and substitution guidance for engineers evaluating the SN75155P in legacy serial-interface designs.
جێگرەوەکانی جێگۆڕکێ بۆ SN75155P — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
هیچ جێگرەوەی ڕاستەوخۆ بۆ ئەم بەرهەمە بەردەست نییە.
داوای جێگرەوەکان بکەSN75155P تایبەتمەندییەکان
| Device Type | RS-232 line driver and receiver |
| Transceiver Configuration | 1/1 full-duplex |
| Interface Standard | ANSI EIA/TIA-232-E |
| Number of Drivers | 1 |
| Number of Receivers | 1 |
| Receiver Response Control | Resistor or resistor and bias voltage connection to ground |
| مەودای پلەی گەرمیی کارکردن | 0°C to 70°C |
| پاکێج | 8-pin PDIP (P) |
| ژمارەی پینەکان | 8 |
| جۆری دامەزراندن | Through-hole |
ڕێنمایی ڕێکخستنی پینی SN75155P 8-pin pdip (p)
ڕێکخستنی پین بۆ SN75155P (پاکێجی 8-pin pdip (p)). ژمارەدانی پین، فەنکشنەکان و نەخشەکانی پەیوەندی لە داتاشیتی بەرھەمھێنەردا پێناسە کراون. سەرنجی بدە بۆ شوێنپێی ورد و ڕێنمایییەکانی لەحیمکردن.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ SN75155P.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
SN75155P گونجاوە بۆ 6 بەکارھێنانs: Legacy Serial Console Interface, Data Terminal Equipment Interface, RS-232 Printer Interface, Industrial Control Panel Communication, RS-232 Test and Measurement Equipment, Modem and Communication Equipment Interface.
Legacy Serial Console Interface
The SN75155P fits a console connection where a host controller must communicate with a serial terminal through an RS-232 port. Its integrated driver and receiver provide one bidirectional signal path in a single 8-pin PDIP package, reducing the component count compared with separate line-driver and receiver ICs. The 0°C to 70°C rating covers equipment enclosures without extended temperature requirements. Place the device near the connector, route its receiver path away from switching nodes, and follow the response-control arrangement in the manufacturer application circuit. Because the supply voltage and data-rate limits must be confirmed from the data sheet, validate them against the host UART before layout release.
پێشنیارکراو
Data Terminal Equipment Interface
The SN75155P is appropriate for data-terminal equipment that needs a dedicated RS-232 transmit and receive path compliant with the ANSI EIA/TIA-232-E interface referenced by the manufacturer. The monolithic implementation combines both directions in one package and includes a receiver response-control input for noise adjustment. Designers can use the control input with a resistor or with a resistor and bias voltage, depending on the receiver-noise strategy defined in the data sheet. Keep the circuit next to the serial connector and provide a stable logic-side supply. Confirm the input thresholds, output levels, and maximum data rate against the connected equipment before the PCB is released.
پێشنیارکراو
RS-232 Printer Interface
The SN75155P can serve as the interface between a controller and a legacy RS-232 printer when the printer uses a single driver and single receiver arrangement. One driver channel handles outgoing command data, while the receiver channel returns status information such as printer-ready or error indications. The 8-pin PDIP package is convenient for through-hole industrial equipment, and the specified 0°C to 70°C range suits normal indoor control cabinets. Position the IC near the DB-25 or equivalent connector, keep the return conductor short, and avoid routing the receiver trace alongside the transmit trace where cable coupling could create false status events.
پێشنیارکراو
Industrial Control Panel Communication
The SN75155P supports legacy control-panel links that exchange commands and diagnostics over RS-232. Its integrated driver, receiver, and response-control input provide a compact implementation for a single serial port, while the commercial 0°C to 70°C rating covers many indoor panels. Connect the receiver input to the protected inbound signal and the driver output to the outbound signal, following the interface diagram in the Texas Instruments data sheet. External surge protection should be placed at the connector boundary rather than relying solely on the IC. Validate the actual panel cable length and ground-reference arrangement because long unbalanced RS-232 cables can couple external noise into the receiver.
پێشنیارکراو
RS-232 Test and Measurement Equipment
The SN75155P is useful in legacy test equipment that needs one isolated-by-cable RS-232 command channel and one status or measurement-data return channel. The transmitter and receiver share one package, allowing a compact instrument design without sacrificing separate directional signal paths. The response-control feature provides a way to tune receiver behavior in noisy laboratory environments, using the network recommended by the manufacturer data sheet. Place the transceiver near the external connector, use a low-impedance logic ground reference, and keep the receiver trace short. Verify the supported data rate and supply voltage before connecting it to an older instrument that may use different logic thresholds.
پێشنیارکراو
Modem and Communication Equipment Interface
The SN75155P can provide the RS-232-facing driver and receiver in modem or communication equipment built around an older UART architecture. Its monolithic construction reduces the board area needed for one transmit and one receive path, and its operation targets the terminal-to-communication equipment interface described by ANSI EIA/TIA-232-E. The response-control input allows receiver-noise optimization when the modem cable leaves the enclosure. Route the driver output and receiver input independently to the connector, observe the external signal and return conductors, and follow the manufacturer application diagram. Confirm the transceiver’s supply voltage, logic levels, and data-rate capability against the host UART.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ SN75155P — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە |
|---|---|
| Brand | Texas Instruments |
| Package | 8-pin PDIP (P) |
| Device Type | RS-232 line driver and receiver |
| Transceiver Configuration | 1/1 full-duplex |
| Number of Drivers | 1 |
| Number of Receivers | 1 |
| Interface Standard | ANSI EIA/TIA-232-E |
| Operating Temperature Range | 0°C to 70°C |
| Receiver Response Control | Resistor or resistor and bias voltage connected to ground |
جیاکەرەوە سەرەکییەکان
- Single-package RS-232 driver and receiver with receiver response control (بەراورد بەSN75155PE4)
- Exact manufacturer-listed PDIP option (بەراورد بەSN75155PG4)
- Dedicated single-channel implementation (بەراورد بەMC3488AP1)
تێبینییەکانی دیزاین
Place the SN75155P close to the external RS-232 connector and route the driver output and receiver input as separate nets toward their respective connector pins. Keep the connector-side ground or return connection short and controlled, and avoid routing the receiver trace parallel to the driver trace on the same board layer. This arrangement reduces capacitive coupling between transmitted and received signals and helps prevent false receiver transitions from cable crosstalk.
Do not assume that a related SN75155-family suffix is automatically interchangeable with the SN75155P. The SN75155P is an 8-pin PDIP part, while comparison listings identify other family members with different packages. Before substitution, compare the package drawing, pin numbering, supply voltage, receiver thresholds, driver levels, and temperature rating. A footprint or function mismatch can require PCB changes or additional termination components.
Use the manufacturer response-control arrangement to tune the receiver, and connect only the resistor or resistor-and-bias network specified by the Texas Instruments data sheet. Keep this network close to the response-control pin and away from the logic-side return-current path. After layout completion, test with the intended cable and peripheral because long external cables can introduce noise that is not present during bench-level logic testing.
زانیاری پابەندبوون
The manufacturer data sheet states that the SN75155 targets ANSI EIA/TIA-232-E equipment interfaces. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status were not stated in the retrieved product information and are therefore recorded as unknown.