ADE9153A vs ADE9153AACPZ Vergleich
Detaillierter Direktvergleich von ADE9153A von Analog Devices und ADE9153AACPZ von Analog Devices. Vergleichen Sie die wichtigsten Spezifikationen, elektrischen Parameter, Gehäuse, Lebenszyklusstatus, Preise und Verfügbarkeit, um das beste Bauteil für Ihre Designanforderungen zu ermitteln.
Analog Devices
ADE9153A - Single-Phase Energy Metering IC, mSure Autocalibration | Analog Devices
ADE9153A ✓ AktivSpezifikationsvergleich
| Parameter | ADE9153A | ADE9153AACPZ |
|---|---|---|
| Marke | Analog Devices | Analog Devices |
| Kategorie | Battery Management | ADC/DAC |
| Lebenszyklusstatus | Aktiv | Aktiv |
| Lagerstatus | In Stock | In Stock |
| Stückpreis (USD) | $4,38 | $4,38 |
| Product Type | Single-Phase Energy Metering IC with mSure Autocalibration | Single-phase energy metering IC |
| Number of ADCs | 3 (high-performance 24-bit sigma-delta) | — |
| Signal-to-Noise Ratio (SNR) | 88 dB | — |
| Current Sensor | Shunt resistor (no CT required) | — |
| Active Energy Accuracy | [DATA_NEEDED: active energy accuracy over dynamic range] | — |
| Measurements | Active energy, fundamental reactive energy, apparent energy, RMS voltage and RMS current | — |
| Power Quality Metrics | Supported per datasheet (specific metrics [DATA_NEEDED]) | — |
| Autocalibration | mSure (no reference source or reference meter required) | mSure automatic current- and voltage-channel calibration |
| Host Interfaces | SPI and I2C | — |
| Gehäuse | 32-LFCSP (5x5 mm), suffix ACPZ | — |
| Betriebstemperaturbereich | -40 °C to +85 °C (industrial) | [DATA_NEEDED: operating temperature range] |
| Versorgungsspannung | [DATA_NEEDED: AVDD/DVDD typical] | — |
| Lead Finish / RoHS | [DATA_NEEDED: lead finish] | — |
| Datasheet Revision | Rev. 0 | — |
| Datasheet Page Count | 50 pages (per third-party datasheet repository) | — |
| Evaluation Kit | EV-ADE9153ASHIELDZ (Arduino shield compatible with Uno, Zero, ESP8266) | — |
| Reference Manual | ADE9153A Technical Reference Manual UG-1247 | — |
| Metering Phase | — | 1 phase |
| Calibration Method | — | Full signal-path measurement without an accurate source or accurate reference meter when a shunt resistor is used |
| Supported Meter Classes | — | Class 1 and Class 2 |
| Current-Sensing Method | — | Shunt-based |
| Package Type | — | 32-LFCSP (5 mm x 5 mm) |
| Lead Count | — | 32 leads |
| Montageart | — | Surface mount |
| ADC Resolution | — | [DATA_NEEDED: ADC resolution] |
| Supply Voltage Range | — | [DATA_NEEDED: supply voltage range] |
| Digital Interface | — | [DATA_NEEDED: digital interface] |
| Voltage-Channel Range | — | [DATA_NEEDED: voltage-channel input range] |
| Current-Channel Range | — | [DATA_NEEDED: current-channel input range] |
| Energy Accuracy | — | [DATA_NEEDED: energy accuracy] |
| Moisture Sensitivity Level | — | MSL 3 (168 hours) |
| RoHS-Status | — | ROHS3 compliant |
| REACH Status | — | Unaffected |
| Lifecycle Recommendation | — | Recommended for new designs |