ADE9153A vs ADE9153AACPZ Comparación
Comparación detallada lado a lado de ADE9153A por Analog Devices y ADE9153AACPZ por Analog Devices. Compare las especificaciones clave, los parámetros eléctricos, el encapsulado, el estado del ciclo de vida, los precios y la disponibilidad para determinar el mejor componente para los requisitos de su diseño.
Analog Devices
ADE9153A - Single-Phase Energy Metering IC, mSure Autocalibration | Analog Devices
ADE9153A ✓ ActivoComparación de especificaciones
| Parámetro | ADE9153A | ADE9153AACPZ |
|---|---|---|
| Marca | Analog Devices | Analog Devices |
| Categoría | Battery Management | ADC/DAC |
| Estado del ciclo de vida | Activo | Activo |
| Estado del stock | In Stock | In Stock |
| Precio unitario (USD) | $4,38 | $4,38 |
| Product Type | Single-Phase Energy Metering IC with mSure Autocalibration | Single-phase energy metering IC |
| Number of ADCs | 3 (high-performance 24-bit sigma-delta) | — |
| Signal-to-Noise Ratio (SNR) | 88 dB | — |
| Current Sensor | Shunt resistor (no CT required) | — |
| Active Energy Accuracy | [DATA_NEEDED: active energy accuracy over dynamic range] | — |
| Measurements | Active energy, fundamental reactive energy, apparent energy, RMS voltage and RMS current | — |
| Power Quality Metrics | Supported per datasheet (specific metrics [DATA_NEEDED]) | — |
| Autocalibration | mSure (no reference source or reference meter required) | mSure automatic current- and voltage-channel calibration |
| Host Interfaces | SPI and I2C | — |
| Encapsulado | 32-LFCSP (5x5 mm), suffix ACPZ | — |
| Rango de temperatura de funcionamiento | -40 °C to +85 °C (industrial) | [DATA_NEEDED: operating temperature range] |
| Tensión de alimentación | [DATA_NEEDED: AVDD/DVDD typical] | — |
| Lead Finish / RoHS | [DATA_NEEDED: lead finish] | — |
| Datasheet Revision | Rev. 0 | — |
| Datasheet Page Count | 50 pages (per third-party datasheet repository) | — |
| Evaluation Kit | EV-ADE9153ASHIELDZ (Arduino shield compatible with Uno, Zero, ESP8266) | — |
| Reference Manual | ADE9153A Technical Reference Manual UG-1247 | — |
| Metering Phase | — | 1 phase |
| Calibration Method | — | Full signal-path measurement without an accurate source or accurate reference meter when a shunt resistor is used |
| Supported Meter Classes | — | Class 1 and Class 2 |
| Current-Sensing Method | — | Shunt-based |
| Package Type | — | 32-LFCSP (5 mm x 5 mm) |
| Lead Count | — | 32 leads |
| Tipo de montaje | — | Surface mount |
| ADC Resolution | — | [DATA_NEEDED: ADC resolution] |
| Supply Voltage Range | — | [DATA_NEEDED: supply voltage range] |
| Digital Interface | — | [DATA_NEEDED: digital interface] |
| Voltage-Channel Range | — | [DATA_NEEDED: voltage-channel input range] |
| Current-Channel Range | — | [DATA_NEEDED: current-channel input range] |
| Energy Accuracy | — | [DATA_NEEDED: energy accuracy] |
| Moisture Sensitivity Level | — | MSL 3 (168 hours) |
| Estado RoHS | — | ROHS3 compliant |
| REACH Status | — | Unaffected |
| Lifecycle Recommendation | — | Recommended for new designs |