ISO1450BDW vs ISO1450BDWR Vergleich

Detaillierter Direktvergleich von ISO1450BDW von Texas Instruments und ISO1450BDWR von Texas Instruments. Vergleichen Sie die wichtigsten Spezifikationen, elektrischen Parameter, Gehäuse, Lebenszyklusstatus, Preise und Verfügbarkeit, um das beste Bauteil für Ihre Designanforderungen zu ermitteln.

Spezifikationsvergleich

Parameter ISO1450BDW ISO1450BDWR
Marke Texas Instruments Texas Instruments
Kategorie Interface ICs Interface ICs
Lebenszyklusstatus Aktiv Aktiv
Lagerstatus In Stock In Stock
Stückpreis (USD) $4,10 $2,95
Protocol RS-422, RS-485 (TIA/EIA-485-A, TIA/EIA-422-B) —
Number of Drivers/Receivers 1/1 —
Duplex Half Half
Maximum Data Rate 50 Mbps —
Isolation Voltage (rms) 5000 Vrms (per UL 1577) 5 kVrms (reinforced)
Working Isolation Voltage (VIOWM) 1060 Vrms —
Surge Isolation Voltage (VIOSM) 10000 Vpk —
Integrated Isolated Power No —
Supply Voltage (VCC1, VCC2) 3 V to 5.5 V [DATA_NEEDED: each rail tolerance] —
Bus Common-Mode Voltage Range -7 V to +12 V [DATA_NEEDED: confirmed in datasheet] —
Bus Pins ESD (IEC 61000-4-2) [DATA_NEEDED: contact/air discharge level] —
Bus Pins EFT (IEC 61000-4-4) [DATA_NEEDED: transient level] —
Betriebstemperaturbereich -40 C to +125 C —
Gehäuse SOIC-16 wide-body (DW) SOIC-16 wide-body (DW), 16 pins
Montageart Surface Mount Surface Mount
MSL-Level 2 (1 year floor life) [DATA_NEEDED: confirm from datasheet] 3 (per JEDEC J-STD-020)
RoHS-Status Compliant Compliant
Funktion — Isolated half-duplex RS-485 / RS-422 transceiver
Data Rate (max) — 50 Mbps
Number of Drivers / Receivers — 1/1
Receiver Hysteresis — [DATA_NEEDED: receiver hysteresis voltage]
Supply Voltage VCC1 (logic side) — 3 V to 5.5 V
Supply Voltage VCC2 (bus side) — Internally generated by isolated DC-DC
Bus Pin ESD (IEC 61000-4-2) — ±16 kV (air / contact, per datasheet)
Bus Pin ESD (HBM) — ±4 kV
IEC 61000-4-4 EFT Immunity — ±4 kV
Surge Immunity — [DATA_NEEDED: IEC 61000-4-5 surge rating]
Unit Load — 1/8 (up to 256 nodes on bus)
Common-Mode Range — Wide common-mode bus voltage range (per datasheet)
Thermisches Abschalten — Yes
Current Limiting — Yes
Low-Power Standby — Yes
Betriebstemperatur — -40C to +125C
Compliance Standards — TIA/EIA-485-A, TIA/EIA-422, IEC 61000-4-2, IEC 61000-4-4

Datenblätter & Ressourcen

Alle Produkte durchsuchen BOM erstellen Angebot anfordern