MPXV7025DP vs MPXV12GW6U Vergleich
Detaillierter Direktvergleich von MPXV7025DP von NXP Semiconductors und MPXV12GW6U von NXP Semiconductors. Vergleichen Sie die wichtigsten Spezifikationen, elektrischen Parameter, Gehäuse, Lebenszyklusstatus, Preise und Verfügbarkeit, um das beste Bauteil für Ihre Designanforderungen zu ermitteln.
Spezifikationsvergleich
| Parameter | MPXV7025DP | MPXV12GW6U |
|---|---|---|
| Marke | NXP Semiconductors | NXP Semiconductors |
| Kategorie | Pressure Sensors | Pressure Sensors |
| Lebenszyklusstatus | Aktiv | Aktiv |
| Lagerstatus | In Stock | In Stock |
| Stückpreis (USD) | $8,05 | $5,10 |
| Pressure Type | Differential (Dual Port) | — |
| Pressure Range | -25 kPa to +25 kPa (-3.63 PSI) | — |
| Operating Pressure Max | ±25 kPa | — |
| Port Style | Dual ports, same side, male 0.13" (3.3 mm) tube | — |
| Versorgungsspannung | 5 V DC nominal | — |
| Ausgangstyp | Analog voltage, ratiometric | Analog Millivolt (Wheatstone bridge) |
| Ausgangsspannungsbereich | 0.2 V to 4.7 V | — |
| Sensitivity | ~90 mV/kPa (at 5 V supply) | — |
| Linearity | ±5 % (over primary range) | — |
| Betriebstemperatur | 0 °C to +85 °C | -40 C to +125 C |
| Storage Temperature | -30 °C to +100 °C (per datasheet range) | — |
| Gehäuse | 8-BSOP (SOP-8, 12.06 mm width), surface mount | — |
| Montageart | Surface Mount | Surface Mount |
| Signal Conditioning | On-chip, calibrated and temperature compensated | — |
| RoHS-Status | Compliant | Compliant |
| Operating Pressure Range | — | 0 kPa to 10 kPa (1.45 PSI) |
| Output Span | — | 0 mV to 55 mV at 3 V excitation |
| Excitation Voltage | — | 3 V typical |
| Pressure Port Type | — | Top port, 0.22" (5.59 mm) tube |
| Gehäuse / Bauform | — | 8-SMD, Gull Wing, Top Port |
| Accuracy | — | [DATA_NEEDED: linearity + temperature coefficient] |
| Configuration | — | Vented Gauge (reference to atmosphere) |
| Sensor Technology | — | Silicon piezoresistive (MEMS strain gauge) |
| Off-Pressure Offset | — | 0 mV minimum (no offset specified) |
| Compensation | — | Uncompensated (external calibration required) |
| MSL-Level | — | [DATA_NEEDED: MSL rating] |
| Bridge Resistance | — | [DATA_NEEDED: input / output bridge impedance] |
| Typical Sensitivity | — | [DATA_NEEDED: mV/kPa at 3 V] |