ADM2687EBRIZ - 5kV Isolated RS-485 Transceiver | Analog Devices
Teilenummer: ADM2687EBRIZ ✓ Aktiv| Menge | Stückpreis | Gesamt |
|---|---|---|
| 1 | $12.5 | $12,50 |
| 10 | $11.25 | $112,50 |
| 100 | $10 | $1.000,00 |
| 500 | $9 | $4.500,00 |
| 1.000 | $8.5 | $8.500,00 |
ADM2687EBRIZ Übersicht
An isolated RS-485 transceiver is a component that combines a differential bus transceiver with galvanic isolation, allowing data transmission between systems with different ground potentials. It typically includes a digital isolator for signal isolation and an integrated DC-to-DC converter for isolated power, eliminating the need for separate isolated power supplies. This integration simplifies PCB design and reduces component count, making it a key building block in industrial automation, building control, and instrumentation systems.
Key features include 5 kV rms isolation, ±15 kV ESD protection on the RS-485 pins, compliance with ANSI/TIA/EIA-485-A-98 and ISO 8482:1987(E), and a configurable half- or full-duplex interface. The integrated isoPower converter provides up to 500 mW of isolated power, and the device operates from a single 5V supply. The wide operating temperature range of -40°C to +85°C ensures reliability in harsh environments.
The ADM2687E uses Analog Devices' proprietary isoPower technology, which integrates a DC-to-DC converter using chip-scale transformers, eliminating the need for external isolated power modules. The device also features a thermal shutdown and a watchdog timer for enhanced system protection. Its high CMTI of 25 kV/µs ensures reliable operation in noisy industrial environments.
Typical applications include industrial fieldbus networks, PROFIBUS, Modbus, building automation, and HVAC systems. The device is also suitable for isolated data acquisition systems and motor control interfaces. Its integrated power and signal isolation make it a compact solution for space-constrained designs.
When designing with the ADM2687EBRIZ, ensure proper PCB layout with adequate creepage and clearance distances for the 5 kV isolation rating. Place the isolation barrier components carefully to maintain isolation integrity. Also, consider the thermal dissipation of the integrated DC-to-DC converter, especially at high data rates and loads.
Drop-in-Alternativen für ADM2687EBRIZ – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit ADM2687EBRIZ (gleiche Bauform und Footprint) – abweichend in Duplex, Package, ESD Protection, Operating Temperature, Data Rate.
Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:
ADM2687EBRIZ-RL7
✅ Drop-In✓ Auf Lager
$5.44 / Stück
Datenblatt ansehen →ADM2682EBRIZ
✅ Drop-In✓ Auf Lager
$7.85 / Stück
Datenblatt ansehen →ADM2587EBRIZ
✅ Drop-In ⚠️ Spezifikationen ungeprüft📋 Referenzalternative (nicht im Katalog)
ISO3082DW
✅ Drop-In ⚠️ Spezifikationen ungeprüft📋 Referenzalternative (nicht im Katalog)
ISL32704EIBZ
✅ Drop-In ⚠️ Spezifikationen ungeprüft📋 Referenzalternative (nicht im Katalog)
ADM2687EBRIZ Technische Daten
| Isolation Voltage | 5000 Vrms |
| Datenrate | 500 kbps |
| Number of Channels | 3 |
| CMTI | 25 kV/µs |
| ESD Protection | ±15 kV |
| Versorgungsspannung | 5 V |
| Isolated Power | 500 mW |
| Duplex | Half/Full |
| Gehäuse | 16-SOIC (0.295", 7.50mm Width) |
| Betriebstemperatur | -40°C to +85°C |
| Standards Compliance | ANSI/TIA/EIA-485-A-98, ISO 8482:1987(E) |
| RoHS | Compliant |
| Montageart | Surface Mount |
| Number of Drivers/Receivers | 1/1 |
ADM2687EBRIZ Pin-Konfiguration
| Pin 1 | VCC — Logic supply voltage (5V) |
| Pin 2 | GND — Logic ground |
| Pin 3 | TXD — Transmit data input |
| Pin 4 | RXD — Receive data output |
| Pin 5 | DE — Driver enable |
| Pin 6 | RE — Receiver enable |
| Pin 7 | A — Non-inverting bus line |
| Pin 8 | B — Inverting bus line |
| Pin 9 | GND — Isolated ground |
| Pin 10 | VISO — Isolated power output |
| Pin 11 | GND — Isolated ground |
| Pin 12 | Y — Driver output (non-inverting) |
| Pin 13 | Z — Driver output (inverting) |
| Pin 14 | GND — Isolated ground |
| Pin 15 | VISO — Isolated power output |
| Pin 16 | GND — Isolated ground |
Typische Anwendungen
ADM2687EBRIZ ist geeignet für 6 Anwendungs: Industrial Fieldbus Networks, Building Automation and HVAC, Isolated Data Acquisition Systems, Motor Control Interfaces, PROFIBUS Networks, Smart Grid and Energy Management.
Industrial Fieldbus Networks
The ADM2687EBRIZ is ideal for industrial fieldbus networks such as PROFIBUS and Modbus, where robust isolation and ESD protection are critical. Its 5 kV rms isolation and ±15 kV ESD protection ensure reliable communication in harsh environments with ground potential differences. The integrated isoPower converter simplifies design by providing isolated power without external components, reducing board space and cost. With a data rate of 500 kbps, it meets the requirements of most fieldbus protocols, and its high CMTI of 25 kV/µs ensures immunity to fast transients common in industrial settings.
Empfohlen
Building Automation and HVAC
In building automation systems, the ADM2687EBRIZ provides isolated RS-485 communication for HVAC controllers, lighting systems, and access control panels. Its integrated power isolation eliminates the need for separate isolated power supplies, simplifying installation and reducing maintenance. The wide operating temperature range of -40°C to +85°C ensures reliable operation in rooftop units and mechanical rooms. The device's compliance with ANSI/TIA/EIA-485-A-98 ensures interoperability with existing building management systems, and its 500 kbps data rate is sufficient for most BACnet and Modbus applications.
Empfohlen
Isolated Data Acquisition Systems
The ADM2687EBRIZ is well-suited for isolated data acquisition systems where sensors and controllers are at different ground potentials. Its 5 kV rms isolation protects sensitive measurement circuitry from ground loops and common-mode noise. The integrated isoPower converter provides clean isolated power for the transceiver and can also power external isolated components, reducing system complexity. With a data rate of 500 kbps, it can handle high-speed data streams from multiple sensors, and its ±15 kV ESD protection ensures robustness in industrial environments.
Empfohlen
Motor Control Interfaces
In motor control systems, the ADM2687EBRIZ provides isolated communication between the controller and motor drives, preventing ground loops and protecting against voltage transients. Its high CMTI of 25 kV/µs ensures reliable operation in the presence of fast switching transients from IGBTs and MOSFETs. The integrated isoPower converter eliminates the need for an external isolated power supply, simplifying the design of multi-axis systems. The device's 500 kbps data rate is adequate for transmitting control signals and feedback data, and its wide temperature range supports operation in industrial motor control cabinets.
Empfohlen
PROFIBUS Networks
The ADM2687EBRIZ is designed for PROFIBUS DP networks, which require isolated RS-485 transceivers with data rates up to 12 Mbps. While the ADM2687E supports only 500 kbps, it is suitable for PROFIBUS PA (process automation) applications that operate at lower speeds. Its 5 kV rms isolation and ±15 kV ESD protection ensure reliable communication in process plants with harsh electromagnetic environments. The integrated isoPower converter simplifies the design of PROFIBUS PA segments, reducing component count and board space.
Empfohlen
Smart Grid and Energy Management
In smart grid applications, the ADM2687EBRIZ provides isolated communication between energy meters, distribution automation devices, and control centers. Its 5 kV rms isolation protects against high-voltage transients and ground potential differences in substations. The integrated isoPower converter enables compact designs for space-constrained meter enclosures. With a data rate of 500 kbps, it supports standard protocols like IEC 61850 and Modbus, and its wide temperature range ensures reliable operation in outdoor environments.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für ADM2687EBRIZ – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | ADM2687EBRIZ-RL7 | ADM2682EBRIZ | ADM2587EBRIZ | ISO3082DW | ISL32704EIBZ |
|---|---|---|---|---|---|---|
| Package | 16-SOIC (0.295", 7.50mm Width) | 16-SOIC (0.295", 7.50mm Width) | 16-SOIC (0.295", 7.50mm Width) | 16-SOIC (0.295", 7.50mm Width) | 16-SOIC (0.295", 7.50mm Width) | 16-SOIC (0.295", 7.50mm Width) |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Texas Instruments | Renesas Electronics |
| Isolation Voltage | 5000 Vrms | 5000 Vrms | 5000 Vrms | 5000 Vrms | 2500 Vrms | 2500 Vrms |
| Data Rate | 500 kbps | 500 kbps | 16 Mbps | 500 kbps | 200 kbps | 40 Mbps |
| Integrated Power | Yes (500 mW) | Yes (500 mW) | Yes (500 mW) | Yes (500 mW) | No | No |
| ESD Protection | ±15 kV | ±15 kV | ±15 kV | ±15 kV | ±16 kV | ±8 kV |
| CMTI | 25 kV/µs | 25 kV/µs | 25 kV/µs | 25 kV/µs | 50 kV/µs | 50 kV/µs |
| Supply Voltage | 5 V | 5 V | 5 V | 5 V | 5 V | 3.3 V |
Wichtigste Unterscheidungsmerkmale
- Integrated isoPower DC-DC converter (vs. ISO3082DW)
- Higher isolation voltage (vs. ISL32704EIBZ)
- Higher ESD protection (vs. ISL32704EIBZ)
Designhinweise
For 5 kV rms isolation, ensure PCB creepage and clearance distances meet the required standards. Typically, a minimum of 8 mm creepage is needed for 5 kV rms. Place the isolation barrier components (transformers, capacitors) with proper spacing to maintain isolation integrity. Use a solid ground plane under the logic side and isolated ground plane under the bus side, with a slot cut between them to prevent leakage currents.
The integrated isoPower converter provides up to 500 mW of isolated power. Ensure the total load on VISO does not exceed this limit. If additional isolated power is needed, consider using an external isolated DC-DC converter. Decouple VCC and VISO with 0.1 µF and 10 µF capacitors placed close to the pins to reduce noise and ensure stable operation.
The ADM2687EBRIZ dissipates power internally due to the integrated DC-DC converter. At maximum load and data rate, the junction temperature may rise significantly. Ensure adequate thermal relief by providing copper pour on the PCB and, if necessary, a thermal pad. The operating temperature range is -40°C to +85°C, so verify that the junction temperature stays within limits under worst-case conditions.
Compliance-Informationen
RoHS compliant per distributor listings. No AEC-Q100 qualification indicated for this part.