ADM3051BRWZ-RL7 is an Analog Devices controller area network (CAN) physical layer transceiver that provides a robust interface between a CAN protocol controller and the two-wire CAN bus. It operates from a single 5 V VCC supply, complies with the ISO 11898 standard, and supports high-speed data rates up to 1 Mbps. The device is offered in an 8-lead SOIC package and is supplied in tape-and-reel packaging for high-volume assembly.

What is a CAN transceiver? A controller area network (CAN) transceiver is an interface IC that converts logic-level signals from a CAN controller into the differential signals required on the CANH and CANL bus lines, and vice versa. It sits between the protocol controller and the physical twisted-pair bus, providing the required differential drive, receive sensitivity, and protection functions. In the system hierarchy, a CAN transceiver is part of the physical layer in a CAN network, below the data-link and application layers. The ADM3051 is a non-isolated, single-channel half-duplex transceiver intended for industrial and automotive networks where ISO 11898 compliant communication at up to 1 Mbps is required.

Key features of ADM3051BRWZ-RL7 include short-circuit protection on CANH and CANL for shorts to power or ground in 24 V systems, operation with unpowered nodes that do not disturb the bus, and capability to connect 110 or more nodes. It also provides slope control on the RS pin to reduce radiated EMI, thermal shutdown protection, and a low-current standby mode for power-sensitive applications. These features make it a physically robust PHY for noisy or high-node-count environments.

Technically, the ADM3051 is a CAN physical-layer IC in the Analog Devices ADM305x family. It uses a differential bus interface and includes bus fault protection and thermal shutdown in a single 8-pin SOIC package. The -RL7 suffix denotes 7-inch reel tape-and-reel packaging, and the BRWZ code indicates the lead-free (Z) SOIC (RW) package variant. The device is designed for 5 V-only systems, simplifying power supply design and enabling direct interface to 5 V CAN controllers without extra level shifting.

Typical applications include industrial automation PLCs, automotive body electronic modules, building management system controllers, battery management systems, medical equipment and CAN data logging nodes. In each of these, the ADM3051's 1 Mbps speed, 110+ node bus capability, and short-circuit protection reduce risk of fieldbus faults while maintaining simple 5 V power architecture.

When designing with ADM3051BRWZ-RL7, place a 120 ohm termination resistor between CANH and CANL at both ends of the bus and set the RS pin resistor to control the slew rate for EMI optimization. For best decoupling, use a 100 nF ceramic capacitor close to VCC and a bulk capacitor at the supply point.

Drop-in-Alternativen für ADM3051BRWZ-RL7 – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit ADM3051BRWZ-RL7 (gleiche Bauform und Footprint) – abweichend in Data Rate, Package, Short-Circuit Protection, Slope Control.

Analog Devices
Data Rate: 1 Mbps
Package: 14-lead SOIC (BRWZ)
Short-Circuit Protection: CANH/CANL to power/ground in 24 V systems
Vergleichen mit ADM3051BRWZ-RL7 →

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

ADM3051CRZ

✅ Drop-In
📦 8-SOIC (SOIC-8)
Same CAN PHY and SOIC-8 package, different grade variant; verify temperature range

📋 Referenzalternative (nicht im Katalog)

MCP2551-I/SN

✅ Drop-In ⚠️ Spezifikationen ungeprüft
📦 8-SOIC (SOIC-8)
Cross-brand CAN transceiver with same SOIC-8 pinout and RS slope-control pin

📋 Referenzalternative (nicht im Katalog)

SN65HVD251DR

✅ Drop-In ⚠️ Spezifikationen ungeprüft
📦 SOIC-8
Cross-brand 5 V, 1 Mbps CAN transceiver in SOIC-8; verify pin 5/pin 8 functions

📋 Referenzalternative (nicht im Katalog)

TJA1050T

✅ Drop-In ⚠️ Spezifikationen ungeprüft
📦 SOIC-8
High-speed CAN transceiver, pin-compatible SOIC-8, no standby mode

📋 Referenzalternative (nicht im Katalog)

PCA82C250T

✅ Drop-In ⚠️ Spezifikationen ungeprüft
📦 SOIC-8
Classic CAN transceiver with slope control on RS pin, same SOIC-8 footprint

📋 Referenzalternative (nicht im Katalog)

TLE6250G

✅ Drop-In ⚠️ Spezifikationen ungeprüft
📦 SOIC-8
Infineon 5 V CAN transceiver with standby/slope control, pin-compatible SOIC-8

📋 Referenzalternative (nicht im Katalog)

ADM3051BRWZ-RL7 Technische Daten

Product Type CAN physical layer transceiver
Supply Voltage (VCC) 5 V
Datenrate up to 1 Mbps
Standard Compliance ISO 11898
Bus Nodes 110 or more
Short-Circuit Protection CANH and CANL against shorts to power/ground in 24 V systems
Unpowered Nodes Do not disturb the bus
Slope Control Yes, for reduced EMI
Thermisches Abschalten Yes
Low Current Standby Mode Yes
Schnittstellentyp Half duplex
Number of Transceivers 1/1 Transceiver Half CANbus
Gehäuse 8-SOIC (SOIC-8)
Montageart Surface Mount
RoHS-Status Lead-free (Z suffix)

ADM3051BRWZ-RL7 Pin-Konfiguration

SOP-8 Package Pinout Diagram SOP-8 8-pin small outline, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOP-8
Pin 1 TXD — CAN controller transmit data input
Pin 2 GND — Ground
Pin 3 VCC — 5 V supply
Pin 4 RXD — CAN receive data output to controller
Pin 5 VREF — Voltage reference output
Pin 6 CANL — Low-level CAN bus line
Pin 7 CANH — High-level CAN bus line
Pin 8 RS — Slope control / standby mode input

Typische Anwendungen

ADM3051BRWZ-RL7 ist geeignet für 6 Anwendungs: Industrial Automation, Automotive Body Electronics, Building Management and HVAC, Battery Management Systems, Medical Equipment, CAN Bus Data Logging.

🏭

Industrial Automation

The ADM3051BRWZ-RL7 fits industrial automation CAN buses because it combines a 5 V ISO 11898 physical layer with 1 Mbps data rate, 110+ node bus capacity, and short-circuit protection on CANH/CANL for 24 V power/ground faults commonly found in factory wiring. In a PLC or remote IO module, the transceiver connects the MCU's CAN controller to a 120-ohm terminated twisted pair. Slope control on the RS pin lowers radiated EMI, which helps with EMC compliance in machine cabling, and the low-current standby mode reduces idle power on distributed modules. Thermal shutdown protects the PHY if a field wiring fault forces a sustained overcurrent.

🚗

Automotive Body Electronics

In automotive body networks, the ADM3051 operates from 5 V and supports high-speed CAN at up to 1 Mbps per ISO 11898, allowing connection to body control modules, lighting, door, and seat modules. The device explicitly supports unpowered nodes that do not disturb the bus, which is valuable when electronic control units (ECUs) are powered down during shipping, diagnostics, or reflashing. Its short-circuit protection covers shorts to power/ground in 24 V truck systems as well as 12 V cars. When paired with an MCU containing a CAN controller such as the SPC560B40L3C6E0X, the ADM3051 forms a compact PHY layer with only termination and filtering components needed.

🌐

Building Management and HVAC

Building management controllers frequently use CAN buses for HVAC, lighting, and access control. The ADM3051BRWZ-RL7's slope control can be adjusted to reduce EMI on long in-wall cable runs, and its 5 V supply simplifies powering the transceiver from a regulated local rail. The 1 Mbps data rate is sufficient for sensor polling and supervisory commands, while the 110+ node fanout supports large distributed systems. Thermal shutdown and 24 V short-circuit protection make the physical layer resilient to installer wiring errors. In a BMS gateway, the ADM3051 can coexist with an isolated RS-485 transceiver such as the ADM2483BRWZ-RL7 to support multiple fieldbus standards on one controller card.

⚡

Battery Management Systems

Battery management systems use CAN to communicate cell voltages, temperatures, and charge-state data between pack monitors and the main controller. The ADM3051BRWZ-RL7 can be placed inside the battery pack or on a gateway board, using its 5 V supply and 1 Mbps CAN link to aggregate data. The low-current standby mode is beneficial for sleep-mode states in vehicles and stationary storage, and short-circuit protection to 24 V rails protects the bus if a harness is chafed or mis-wired. The 110+ node capability permits multiple pack monitors on a single bus. It pairs well with an Analog Devices BMS stack monitor such as the ADBMS6948, which measures cell voltage and temperature and reports over serial communication that can bridge to CAN.

💊

Medical Equipment

Medical equipment such as patient monitors and diagnostic carts may use a CAN bus to interconnect modules. The ADM3051BRWZ-RL7 provides an ISO 11898-compliant 5 V CAN physical layer at up to 1 Mbps with low EMI via slope control, which is helpful in electromagnetically quiet environments near sensitive analog front ends. Its thermal shutdown and short-circuit protection improve reliability when modules are hot-swapped or when a cable is accidentally damaged. The low-current standby mode meets the low-idle-power needs of battery-powered portable medical devices. Using the RS pin to set a slower slew rate also minimizes radiation, an important consideration for medical EMC standards.

🔧

CAN Bus Data Logging

For CAN data loggers, fleet telematics, and test instrumentation, the ADM3051BRWZ-RL7 offers a simple 5 V PHY that can be tapped onto an existing 1 Mbps CAN bus without disturbing connected nodes. Since unpowered nodes do not disturb the bus, a logger can be disconnected when not in use. The 110+ node capacity ensures the monitor does not overload a dense bus. In a logger front end, the ADM3051 converts differential bus signals to RXD logic levels for a CAN interface MCU, and its TXD input drives the bus under software control. Slope control allows the designer to tune the edge rate for EMC in vehicle installations.

Where to buy ADM3051BRWZ-RL7 online?
The ADM3051BRWZ-RL7 is available from authorized distributors including DigiKey, Mouser and Octopart-listed suppliers. According to the Analog Devices ADM3051 datasheet, the -RL7 suffix indicates 7-inch tape-and-reel packaging. As of 2026-08-23, check distributor stock and lead times for the most current availability.
What is the price of ADM3051BRWZ-RL7?
As of 2026-08-23, the ADM3051BRWZ-RL7 is typically priced around $2.10 per unit at quantity 1, with volume pricing near $1.12 at 1,000 pieces. These prices are estimated from distributor market data and may vary by region and inventory; confirm final pricing on DigiKey, Mouser, or Octopart before ordering.
What is the lead time for ADM3051BRWZ-RL7?
Lead time for ADM3051BRWZ-RL7 depends on distributor stock and order quantity. Common lead times are 4 to 8 weeks when parts are not on the shelf. As of 2026-08-23, distributors such as DigiKey and Mouser sometimes show stock available for immediate shipment, so verify real-time inventory before committing to a schedule.
ADM3051BRWZ-RL7 vs ADM3051CRZ - which is better for industrial CAN?
Both ADM3051BRWZ-RL7 and ADM3051CRZ are 8-pin SOIC CAN transceivers from Analog Devices with the same 5 V, 1 Mbps, ISO 11898 physical-layer functionality. The primary difference is grade variant and packaging; the CRZ is a separate ordering option. Choose the BRWZ-RL7 for 7-inch reel tape-and-reel volume assembly, and verify the operating temperature range of your chosen grade in the Rev. A datasheet.
What is the difference between ADM3051BRWZ-RL7 and MCP2551-I/SN?
Both are pin-compatible 8-pin SOIC CAN transceivers. ADM3051BRWZ-RL7 is an Analog Devices ISO 11898 device with 5 V supply, 1 Mbps data rate, slope control, low-current standby, and specified 24 V short-circuit protection. MCP2551-I/SN is a Microchip equivalent with the same SOIC-8 pinout and RS slope-control pin, but its short-circuit and standby behavior may differ; verify those parameters in the Microchip datasheet before using it as a substitute.
When should I choose ADM3051BRWZ-RL7 over SN65HVD251DR?
Choose ADM3051BRWZ-RL7 when you want an Analog Devices CAN PHY with a low-current standby mode, slope-control tuning, and explicitly specified 24 V short-circuit protection. SN65HVD251DR from Texas Instruments is a pin-compatible 5 V, 1 Mbps CAN transceiver but has different standby and slope-control details; if those parameters are not critical, SN65HVD251DR can be a cost-effective second source, but verify pin 5 and pin 8 functions first.
Is ADM3051BRWZ-RL7 suitable for automotive applications?
The ADM3051BRWZ-RL7 complies with ISO 11898 and operates from 5 V, so it can be used in automotive body and powertrain CAN networks. However, this is not confirmed as an AEC-Q100 qualified part in the verified data, so for safety-critical automotive applications requiring formal qualification, verify the device grade and consider qualified CAN transceivers from your OEM approved vendor list.
What is the best drop-in replacement for ADM3051BRWZ-RL7?
The best same-brand drop-in replacement is the ADM3051CRZ from Analog Devices, which uses the same SOIC-8 package and CAN physical layer. Cross-brand SOIC-8 alternatives include the Microchip MCP2551-I/SN, Texas Instruments SN65HVD251DR, and NXP TJA1050T; all are 5 V, 1 Mbps CAN transceivers that should be verified for pin 5 VREF/RS behavior before production use.
Where to download ADM3051BRWZ-RL7 datasheet PDF?
The official ADM3051 datasheet PDF (Rev. A) is available at analog.com/media/en/technical-documentation/data-sheets/ADM3051.pdf. It contains pin assignments, electrical characteristics, slope-control guidance, and typical application circuits. You can also access the datasheet through DigiKey's HTML datasheet mirror for faster viewing.
What is the maximum data rate of ADM3051BRWZ-RL7?
The ADM3051 supports data rates up to 1 Mbps in compliance with ISO 11898. This makes it suitable for standard high-speed CAN applications such as industrial automation, automotive body control, and battery management systems. For data rates beyond 1 Mbps, such as CAN FD, a different transceiver with higher speed capability would be required.
What is the supply voltage for ADM3051BRWZ-RL7?
The ADM3051 operates from a single 5 V VCC supply. This rail-powered architecture simplifies interfacing with 5 V CAN controllers and avoids the need for level shifting. A clean 5 V supply with appropriate decoupling, typically 100 nF close to VCC plus a bulk capacitor, should be used to maintain reliable bus signaling.
How many CAN nodes can ADM3051BRWZ-RL7 support?
The ADM3051 can connect 110 or more nodes on a CAN bus. This large fanout is achieved through the standard ISO 11898 receiver input resistance and driver output specifications. In practice, the total node count also depends on bus termination, cable length, and data rate; follow good CAN physical-layer layout rules to maximize node count.
What are the key specifications of ADM3051BRWZ-RL7 that engineers should know?
The ADM3051BRWZ-RL7 is an ISO 11898-compliant CAN physical layer transceiver operating from a 5 V VCC, running up to 1 Mbps, connecting 110+ nodes, with short-circuit protection on CANH/CANL against 24 V power/ground shorts, slope control for EMI, thermal shutdown, and low-current standby mode. It comes in an 8-lead SOIC package in tape-and-reel format.
What is the best TI or Microchip equivalent for ADM3051BRWZ-RL7?
The best Microchip equivalent is the MCP2551-I/SN, and the best Texas Instruments equivalent is the SN65HVD251DR. Both are 8-pin SOIC, 5 V, 1 Mbps CAN transceivers with standard CANH/CANL/RXD/TXD pins. Before selecting either as a drop-in, verify pin 5 and pin 8 functions because some alternatives use VREF, SPLIT, RS, or STB variants that affect slope control and standby behavior.

Technische Referenzdaten für ADM3051BRWZ-RL7 – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the ADM3051BRWZ-RL7 when you need a 5 V, ISO 11898 CAN PHY in an 8-pin SOIC with slope control, standby mode, and tape-and-reel supply for volume manufacturing. Choose ADM3051CRZ when you need the same physical layer with an extended-temperature grade (verify grade in datasheet). Choose MCP2551-I/SN or SN65HVD251DR as cost-effective cross-source options if the system can tolerate their slew-rate and standby behavior. Choose TJA1050T when only high-speed CAN is required and standby current is not critical. For heavily fault-prone 24 V industrial cabling, ADM3051's specified short-circuit and unpowered-node protection is preferred. If you require isolation, move to ADM3054 or ADM2483 for isolated CAN/RS-485 rather than the non-isolated ADM3051.

Vergleich mit Alternativen

Parameter Dieses Produkt ADM3051CRZ MCP2551-I/SN SN65HVD251DR TJA1050T
Package 8-SOIC (SOIC-8) 8-SOIC (SOIC-8) 8-SOIC (SOIC-8) SOIC-8 SOIC-8
Brand Analog Devices Analog Devices Microchip Texas Instruments NXP
Supply Voltage 5 V 5 V 5 V 5 V 5 V
Data Rate 1 Mbps 1 Mbps 1 Mbps 1 Mbps 1 Mbps
Short-Circuit Protection CANH/CANL to 24 V power/ground CANH/CANL to 24 V power/ground Yes (parametric step) Yes Yes
Slope Control Yes, via RS pin Yes, via RS pin Yes, via RS pin Yes, via R_s pin Yes, via RS pin
Pin 5 Function VREF VREF VREF VREF (verify) VREF

Wichtigste Unterscheidungsmerkmale

  • Robust fault protection specified for 24 V industrial systems (vs. MCP2551-I/SN)
  • Low-current standby mode (vs. TJA1050T)
  • Same-brand grade variant flexibility (vs. ADM3051CRZ)
  • Slope control for EMI tuning (vs. SN65HVD251DR)

Designhinweise

Terminate the CAN bus with a 120 ohm resistor between CANH and CANL at each physical end of the network. Stub lengths from transceivers to the bus should be kept as short as possible, ideally below 0.3 m at 1 Mbps, to avoid reflections. The ADM3051 supports 110+ nodes, but that node count assumes proper termination and cable impedance matching. Failure to terminate correctly will cause bit errors and degrade EMC performance.

Place a 100 nF ceramic capacitor as close as possible to the VCC pin and a 1 uF to 10 uF bulk capacitor at the VCC entry point of the transceiver. Keep the CANH and CANL traces balanced and routed as a differential pair with controlled impedance. Do not route the bus traces underneath the transceiver on an adjacent plane unless you maintain a clean ground reference. The RS pin should be connected to a resistor (or direct low level) for slope control; select the resistor value per the datasheet slope-control graph to limit EMI.

The ADM3051 has thermal shutdown protection to prevent damage during bus fault conditions. In normal operation the SOIC-8 package dissipates very little power, but a sustained short on CANH or CANL can generate significant heating. Ensure the PCB provides a low thermal resistance path through the GND plane. If the part repeatedly enters thermal shutdown, check bus wiring and harness connectors for short circuits against 24 V or ground in industrial systems.

For unpowered-node behavior, the ADM3051 presents a high impedance to the bus when VCC is removed, so modules can be disconnected without disturbing communication. To preserve this feature, avoid adding external pull-up or pull-down resistors to CANH/CANL that would load the bus when the transceiver is unpowered. Add an optional common-mode choke on CANH/CANL for improved EMC immunity in noisy industrial or automotive environments.

Compliance-Informationen

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Qualified
Bleifrei
Yes
Halogenfrei
Unknown
Konfliktmineralien
Unknown

Lead-free/RoHS compliant per Z suffix. AEC-Q100 qualification is not confirmed in the verified data. Verify material declarations on the Analog Devices packaging quality page before high-volume production.

Daten verifiziert am: 2026-08-23 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

ADM3051BRWZ-RL7 datasheet ADM3051BRWZ-RL7 price Analog Devices ADM3051 CAN transceiver 5V ISO 11898 CAN transceiver SOIC-8 ADM3051BRWZ-RL7 vs ADM3051CRZ ADM3051 drop-in replacement MCP2551 equivalent to ADM3051 ADM3051BRWZ-RL7 pinout industrial CAN transceiver 1 Mbps CAN transceiver for battery management system buy ADM3051BRWZ-RL7 tape and reel what is ADM3051BRWZ-RL7

Verwandte Bauteile & Begriffe

Analog Devices ADM3051 ADM3051BRWZ-RL7 ADM3051CRZ MCP2551-I/SN SN65HVD251DR TJA1050T CAN CAN transceiver Controller Area Network ISO 11898 SOIC-8 ROHS slope control thermal shutdown short-circuit protection low-current standby 1 Mbps industrial automation automotive body electronics battery management system data logging SPC560B40L3C6E0X ADBMS6948 AD7175-2BRUZ
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen