Texas Instruments

ADS1130IPW - 18-Bit, 80SPS Bridge-Sensor ADC | Texas Instruments

Teilenummer: ADS1130IPW ✓ Aktiv
16-pin TSSOP (PW) Package
MOQ: 1 |

ADS1130IPW Übersicht

Texas Instruments ADS1130IPW is a precision 18-bit, single-channel delta-sigma analog-to-digital converter optimized for resistive bridge sensors, with an 80 SPS conversion rate and a 16-pin TSSOP package. It integrates a low-noise gain amplifier, onboard oscillator, and precision 18-bit delta-sigma ADC to form a complete front end for strain gauges, weigh scales, and similar bridge-sensor systems.

A sigma-delta ADC is a voltage-regulating data-converter category that uses continuous-time oversampling and digital filtering to provide high resolution and excellent rejection of low-frequency noise. The ADS1130 belongs to the ADC hierarchy, combining a low-noise analog gain stage with a delta-sigma conversion core and serial interface. This integration reduces the number of external precision components required in a bridge measurement circuit.

The principal operating characteristics include 18-bit resolution, 80 SPS throughput, one differential input channel, and a programmable low-noise gain amplifier. The integrated oscillator supports a complete measurement front end without an external clock source. According to the Texas Instruments ADS1130 datasheet, the device is specifically designed for resistive bridge sensors and weigh-scale applications rather than general-purpose high-speed waveform conversion.

The delta-sigma architecture prioritizes resolution and noise performance over conversion latency. Digital filtering suppresses broadband and low-frequency noise while averaging successive conversions, making the converter appropriate for slowly changing force, pressure, or strain signals. The onboard gain amplifier conditions the small differential output generated by a Wheatstone bridge before conversion, while the internal reference and oscillator support repeatable measurement operation.

Typical uses include electronic weighing systems, strain-gauge instrumentation, industrial force sensing, pressure transmitters, and laboratory measurement equipment. In a weigh-scale design, the bridge output can be connected directly to the differential input, with the excitation voltage and signal ground referenced carefully to minimize common-mode errors and thermoelectric offsets.

A critical design consideration is the relationship between bridge excitation, input range, gain, and allowable overvoltage. Confirm the selected gain and excitation voltage against the maximum bridge output and the device electrical limits before calibration. Place filtering and protection components where they will not disturb sensitive bridge routing, and route analog and digital return currents separately to reduce measurement error.

This product page combines the manufacturer's key device characteristics with practical application guidance, package information, sourcing instructions, and a careful review of drop-in replacement evidence. The replacement analysis deliberately distinguishes confirmed interchangeability from devices that merely use a similar package or function, helping engineers avoid PCB, interface, and calibration risks.

Drop-in-Alternativen für ADS1130IPW – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Für dieses Produkt sind keine Drop-in-Alternativen verfügbar.

Alternativen anfordern

ADS1130IPW Grenzwerte & elektrische Eigenschaften

ADC Resolution 18 bit
Conversion Rate 80 SPS
Number of Input Channels 1 channel
Input Architecture 1 sigma-delta differential input channel
Conversion Architecture Delta-sigma
Integrated Gain Amplifier Onboard low-noise gain amplifier
Integrated Oscillator Onboard oscillator
Primary Signal Type Resistive bridge sensor output
Package Type 16-pin TSSOP (PW)
Package Pin Count 16 pins
Betriebstemperaturbereich -40 C to +85 C
Montageart Surface mount

ADS1130IPW 16 pins Pinbelegungsleitfaden

Pinbelegung für ADS1130IPW (16 pins-Gehäuse). Dieses analoge Bauteil verfügt über Eingangs-, Ausgangs- und Versorgungspins. Offset-Null-, Kompensations- und Enable-Pin-Konfigurationen entnehmen Sie dem Herstellerdatenblatt. Ideal für Signalaufbereitung und Verstärkerschaltungen.

Pinbelegungsdiagramm für ADS1130IPW im 16 pins-Gehäuse

Keine detaillierten Pinbelegungsdaten verfügbar für ADS1130IPW.

Siehe die Datenblatt für die vollständige Pin-Konfiguration.

Typische Anwendungen

ADS1130IPW ist geeignet für 6 Anwendungs: Precision Weigh Scale, Strain-Gauge Instrumentation, Industrial Pressure Transmitter, Force and Load Monitoring, Laboratory Measurement Equipment, Process-Control Sensing.

⚖️

Precision Weigh Scale

The ADS1130IPW fits the measurement front end of a resistive load-cell bridge because it combines an 18-bit delta-sigma ADC with a low-noise gain amplifier and onboard oscillator. At 80 SPS, it can acquire the slowly changing differential voltage generated by force applied to the load cell. The bridge excitation determines the full-scale input range, so calibrate gain, offset, and scale with the selected excitation source. This arrangement reduces the need for separate low-noise amplification while preserving sufficient resolution for commercial weighing and precision force measurement.

🏭

Strain-Gauge Instrumentation

A strain gauge commonly forms one arm of a Wheatstone bridge and produces a small differential voltage when mechanical strain changes. The ADS1130IPW conditions this signal with its onboard low-noise gain amplifier and converts it with an 18-bit delta-sigma core at 80 SPS. That speed is well matched to slowly varying strain, force, and displacement signals. Board layout must minimize thermoelectric offsets and keep bridge excitation and sensitive input routing away from switching circuitry to preserve measurement stability.

🧩

Industrial Pressure Transmitter

The ADS1130IPW is appropriate for pressure transmitters whose sensing element produces a differential bridge output. Its 18-bit conversion resolution improves the available digital span for slow pressure changes, while the 80 SPS sampling rate provides continuous updates without the latency profile of a high-speed waveform ADC. Confirm that the bridge excitation and maximum differential output remain within the selected gain and electrical limits. Digital filtering and calibration should be selected for the transmitter's required response time and measurement noise.

🤖

Force and Load Monitoring

Force platforms, robotic fixtures, and compression testers often rely on bridge sensors whose output changes slowly enough for the ADS1130IPW's 80 SPS conversion rate. Integrating the gain amplifier, oscillator, and 18-bit delta-sigma converter into a 16-pin TSSOP simplifies analog-front-end design. The resulting measurement chain can resolve small differential signals while supporting digital filtering and system calibration. Mechanical vibration should be considered because its spectral content may require averaging, filtering, or a higher-speed converter.

🔬

Laboratory Measurement Equipment

The ADS1130IPW can serve as the acquisition element in bench instruments that measure resistive transducers with low-frequency signals. Its 18-bit resolution, onboard oscillator, and integrated low-noise gain amplifier create a compact measurement front end, while the 80 SPS rate is suitable for calibrated static readings and controlled ramps. For laboratory accuracy, use a stable excitation source, shield sensitive bridge nodes, maintain consistent return paths, and perform gain and offset calibration after thermal stabilization.

⚙️

Process-Control Sensing

Slowly varying process variables can be represented by a resistive bridge when the measurement requires differential excitation and low-noise signal conditioning. The ADS1130IPW provides one 18-bit delta-sigma channel at 80 SPS, making it suitable for supervisory sensing rather than fast feedback loops. Place the converter near the bridge input to minimize sensitive-node routing, and separate analog and digital return currents to reduce coupling. The system response time must be compared with the control loop requirements because digital filtering adds latency.

What is the ADS1130IPW used for?
The ADS1130IPW is used to measure low-level differential signals from resistive bridge sensors. It combines a low-noise gain amplifier, an onboard oscillator, and an 18-bit delta-sigma ADC in one package. According to the Texas Instruments ADS1130 datasheet, the device supports bridge-sensor front ends used in weigh scales, strain gauges, pressure equipment, and industrial force-measurement systems.
What are the key specifications of ADS1130IPW that engineers should know?
The ADS1130IPW provides 18-bit resolution, an 80 SPS conversion rate, one differential input channel, and an integrated low-noise gain amplifier. The device is packaged in a 16-pin TSSOP and has a listed operating-temperature range of -40 C to +85 C. These characteristics make it suitable for precision resistive bridge measurements rather than high-speed waveform acquisition.
What is the resolution and sample rate of ADS1130IPW?
The ADS1130IPW delivers 18-bit resolution at up to 80 samples per second. According to the Texas Instruments ADS1130 product page, it is a one-channel delta-sigma ADC intended for bridge sensors and weigh scales. This rate favors accurate acquisition of slowly changing sensor signals rather than high-bandwidth sampling.
Is ADS1130IPW suitable for strain-gauge measurements?
Yes, the ADS1130IPW is suitable for strain-gauge and other resistive bridge measurements. Its 18-bit resolution, integrated low-noise gain amplifier, onboard oscillator, and differential input support small bridge-generated signals. Texas Instruments identifies resistive bridge sensors, strain gauges, and weigh scales as primary applications for this ADC.
Can ADS1130IPW be used in a precision weigh scale?
The ADS1130IPW can serve as the ADC in a precision weigh scale because it is designed around one-channel resistive bridge measurement. Its 18-bit delta-sigma conversion and 80 SPS throughput suit the slowly changing force signal produced by a load-cell bridge. Calibration, bridge excitation, grounding, and gain selection remain critical to achieving useful system accuracy.
ADS1130IPW vs ADS1130IPWR - what is the difference?
ADS1130IPW and ADS1130IPWR identify orderable configurations of the same ADS1130 family, while the manufacturer listing for ADS1130IPW identifies a 16-pin TSSOP package. The cross-reference results do not establish a functional or pinout difference. Treat the suffix distinction as a procurement and packing matter, and confirm the required orderable configuration before placing a purchase.
ADS1130IPW vs ADS1118 - which one should I choose?
Choose the ADS1130IPW when its 18-bit, 80 SPS, one-channel bridge-sensor architecture matches the design. The ADS1118 is not a confirmed pin-to-pin replacement because its internal architecture and interface signaling differ despite a similar TSSOP-16 package. A PCB-level substitution therefore requires a complete pin, timing, power, and firmware review rather than footprint matching alone.
When should I choose ADS1130IPW over ADS1130IPWR?
Choose ADS1130IPW when that exact orderable suffix matches the required assembly and procurement plan. Choose ADS1130IPWR when the approved bill of materials calls for the alternate orderable configuration. Both belong to the ADS1130 family and share the 18-bit, 80 SPS bridge-sensor function, but the available manufacturer ordering information should control the final choice.
Is ADS1130IPW suitable for a pressure transmitter?
The ADS1130IPW is suitable when a pressure transmitter uses a resistive bridge and produces a slowly changing differential output. Its 18-bit resolution and integrated low-noise gain amplifier support precise bridge measurement, while the 80 SPS rate is appropriate for pressure and force signals with low bandwidth. Verify the transducer excitation range and output voltage before selecting the converter gain.
What is the best drop-in replacement for ADS1130IPW?
No independently verified cross-manufacturer drop-in replacement for ADS1130IPW was identified. ADS1130IPWR is an orderable ADS1130-family configuration, but the available cross-reference results do not establish a different drop-in device. Do not substitute an ADC merely because it has a 16-pin TSSOP package; verify every pin, supply requirement, serial protocol, timing parameter, and calibration procedure first.
What can replace ADS1130IPW?
ADS1130IPWR is the closest confirmed orderable alternative because it belongs to the same ADS1130 family, but the available information does not quantify a distinct engineering change between the suffixes. No cross-brand pin-to-pin equivalent was confirmed. For a functional redesign, evaluate bridge-input ADC families against resolution, conversion rate, gain, interface, and calibration requirements rather than assuming a drop-in replacement.
What is the best Analog Devices equivalent for ADS1130IPW?
No Analog Devices part was confirmed as a pin-to-pin equivalent for ADS1130IPW. Analog Devices offers other bridge-sensor and high-resolution ADC families, but a similar converter function does not establish package, pin, timing, or interface compatibility. Use the Request a Quote form to discuss the exact cross-brand sourcing requirement, and request manufacturer documentation before committing to a substitute.
Where can I download the ADS1130IPW datasheet PDF?
Download the ADS1130IPW datasheet PDF from the official Texas Instruments ADS1130 documentation page linked on this product page. The manufacturer product page also provides ordering, parameter, quality, and support information. Use the manufacturer PDF as the controlling document for pin assignments, electrical limits, recommended application circuits, and calibration details.
Where can I find the ADS1130IPW pinout?
The ADS1130IPW pinout is in the pin-configuration section of the official Texas Instruments ADS1130 datasheet. This orderable device uses a 16-pin TSSOP package, identified by the PW package code in the manufacturer listing. Assign PCB tracks from the manufacturer pin table and package drawing rather than relying on a generic 16-pin image.
Where to buy ADS1130IPW online and what is its price?
Use the Request a Quote form on this page to request the current ADS1130IPW price, stock position, minimum order quantity, and lead time. The product is offered through multiple distribution channels, but commercial terms can change quickly and should be confirmed for the exact 16-pin TSSOP orderable suffix. The form provides a direct quotation path without relying on stale listing information.

Technische Referenzdaten für ADS1130IPW – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

The ADS1130IPW is best suited to single-channel resistive bridge measurements where an 18-bit delta-sigma ADC, 80 SPS throughput, and integrated low-noise gain amplifier provide a compact front end. It is particularly appropriate for load cells, strain gauges, pressure transmitters, and slow force or displacement systems. ADS1130IPWR belongs to the same product family and can be considered when procurement requirements call for that orderable configuration, but the suffix distinction is not a functional upgrade. The ADS1118 should not be treated as a drop-in replacement because similar TSSOP packaging does not eliminate internal architecture and interface-signal differences. For a cross-brand redesign, begin with functional requirements rather than package similarity: resolution, conversion rate, programmable gain, excitation limits, common-mode range, serial interface, timing, calibration, and supply requirements. If no verified cross-manufacturer part satisfies all of those conditions, retaining the ADS1130 platform is the lower-risk choice for a production revision.

Designhinweise

Route the bridge excitation, bridge return, and differential input as a compact, continuous analog path. Keep the ADS1130IPW close to the bridge connection and keep switching-regulator traces, high-current paths, and digital clock lines away from the sensitive input nodes. A solid ground plane can help, but analog and digital return currents should be organized so bridge current does not share paths with digital output currents.

Do not select the gain solely from the ADC resolution. First calculate the maximum bridge differential voltage at full scale, then verify that this voltage and its polarity remain within the selected gain and input range at the worst-case excitation, tolerance, and temperature conditions. Inadequate headroom can clip the signal, while excessive gain can amplify offsets and common-mode error.

The 18-bit conversion resolution does not eliminate analog-layout errors such as thermoelectric offsets, excitation ripple, or ground disturbances. Use a stable excitation source, maintain symmetrical bridge connections, and allow the assembly to reach thermal equilibrium before precision calibration. Apply digital averaging only after establishing the required update time; each additional conversion extends the measurement latency.

Compliance-Informationen

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Bleifrei
Unknown
Halogenfrei
Unknown
Konfliktmineralien
Unknown

The manufacturer product page and ordering listing identify the ADS1130IPW as an active 16-pin TSSOP device, but the retrieved excerpts do not state specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals statuses.

Daten verifiziert am: 2026-11-18 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

ADS1130IPW datasheet ADS1130IPW pinout ADS1130IPW datasheet pdf ADS1130IPW schematic ADS1130IPW equivalent ADS1130IPW replacement ADS1130IPW cross reference ADS1130IPW vs ADS1118 ADS1130IPW footprint ADS1130IPW price ADS1130IPW stock Texas Instruments ADS1130IPW ADS1130IPW bridge sensor ADC ADS1130 TSSOP-16 pinout ADS1130IPW application circuit

Verwandte Bauteile & Begriffe

Texas Instruments ADS1130 ADS1130IPW ADS1130IPWR ADS1118 Analog-to-digital converter ADC delta-sigma ADC sigma-delta ADC precision data converter 18-bit resolution 80 SPS low-noise gain amplifier onboard oscillator resistive bridge sensor Wheatstone bridge strain gauge weigh scale pressure transmitter industrial force measurement TSSOP-16 PW package surface mount serial interface Texas Instruments ADS1130 datasheet
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen