ADS1130IPW - 18-Bit, 80SPS Bridge-Sensor ADC | Texas Instruments
MPN: ADS1130IPW ✓ 啟用中ADS1130IPW 概覽
A sigma-delta ADC is a voltage-regulating data-converter category that uses continuous-time oversampling and digital filtering to provide high resolution and excellent rejection of low-frequency noise. The ADS1130 belongs to the ADC hierarchy, combining a low-noise analog gain stage with a delta-sigma conversion core and serial interface. This integration reduces the number of external precision components required in a bridge measurement circuit.
The principal operating characteristics include 18-bit resolution, 80 SPS throughput, one differential input channel, and a programmable low-noise gain amplifier. The integrated oscillator supports a complete measurement front end without an external clock source. According to the Texas Instruments ADS1130 datasheet, the device is specifically designed for resistive bridge sensors and weigh-scale applications rather than general-purpose high-speed waveform conversion.
The delta-sigma architecture prioritizes resolution and noise performance over conversion latency. Digital filtering suppresses broadband and low-frequency noise while averaging successive conversions, making the converter appropriate for slowly changing force, pressure, or strain signals. The onboard gain amplifier conditions the small differential output generated by a Wheatstone bridge before conversion, while the internal reference and oscillator support repeatable measurement operation.
Typical uses include electronic weighing systems, strain-gauge instrumentation, industrial force sensing, pressure transmitters, and laboratory measurement equipment. In a weigh-scale design, the bridge output can be connected directly to the differential input, with the excitation voltage and signal ground referenced carefully to minimize common-mode errors and thermoelectric offsets.
A critical design consideration is the relationship between bridge excitation, input range, gain, and allowable overvoltage. Confirm the selected gain and excitation voltage against the maximum bridge output and the device electrical limits before calibration. Place filtering and protection components where they will not disturb sensitive bridge routing, and route analog and digital return currents separately to reduce measurement error.
This product page combines the manufacturer's key device characteristics with practical application guidance, package information, sourcing instructions, and a careful review of drop-in replacement evidence. The replacement analysis deliberately distinguishes confirmed interchangeability from devices that merely use a similar package or function, helping engineers avoid PCB, interface, and calibration risks.
直接替換替代品,適用於 ADS1130IPW — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此產品無可直接替換的替代品。
申請替代品ADS1130IPW 最大額定值與電氣特性
| ADC Resolution | 18 bit |
| Conversion Rate | 80 SPS |
| Number of Input Channels | 1 channel |
| Input Architecture | 1 sigma-delta differential input channel |
| Conversion Architecture | Delta-sigma |
| Integrated Gain Amplifier | Onboard low-noise gain amplifier |
| Integrated Oscillator | Onboard oscillator |
| Primary Signal Type | Resistive bridge sensor output |
| Package Type | 16-pin TSSOP (PW) |
| Package Pin Count | 16 pins |
| 工作溫度範圍 | -40 C to +85 C |
| 安裝類型 | Surface mount |
ADS1130IPW 16 pins 腳位配置指南
ADS1130IPW(16 pins 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: ADS1130IPW.
請參閱 資料表 以查看完整腳位配置。
典型應用
ADS1130IPW 適用於 6 應用s: Precision Weigh Scale, Strain-Gauge Instrumentation, Industrial Pressure Transmitter, Force and Load Monitoring, Laboratory Measurement Equipment, Process-Control Sensing.
Precision Weigh Scale
The ADS1130IPW fits the measurement front end of a resistive load-cell bridge because it combines an 18-bit delta-sigma ADC with a low-noise gain amplifier and onboard oscillator. At 80 SPS, it can acquire the slowly changing differential voltage generated by force applied to the load cell. The bridge excitation determines the full-scale input range, so calibrate gain, offset, and scale with the selected excitation source. This arrangement reduces the need for separate low-noise amplification while preserving sufficient resolution for commercial weighing and precision force measurement.
Strain-Gauge Instrumentation
A strain gauge commonly forms one arm of a Wheatstone bridge and produces a small differential voltage when mechanical strain changes. The ADS1130IPW conditions this signal with its onboard low-noise gain amplifier and converts it with an 18-bit delta-sigma core at 80 SPS. That speed is well matched to slowly varying strain, force, and displacement signals. Board layout must minimize thermoelectric offsets and keep bridge excitation and sensitive input routing away from switching circuitry to preserve measurement stability.
Industrial Pressure Transmitter
The ADS1130IPW is appropriate for pressure transmitters whose sensing element produces a differential bridge output. Its 18-bit conversion resolution improves the available digital span for slow pressure changes, while the 80 SPS sampling rate provides continuous updates without the latency profile of a high-speed waveform ADC. Confirm that the bridge excitation and maximum differential output remain within the selected gain and electrical limits. Digital filtering and calibration should be selected for the transmitter's required response time and measurement noise.
Force and Load Monitoring
Force platforms, robotic fixtures, and compression testers often rely on bridge sensors whose output changes slowly enough for the ADS1130IPW's 80 SPS conversion rate. Integrating the gain amplifier, oscillator, and 18-bit delta-sigma converter into a 16-pin TSSOP simplifies analog-front-end design. The resulting measurement chain can resolve small differential signals while supporting digital filtering and system calibration. Mechanical vibration should be considered because its spectral content may require averaging, filtering, or a higher-speed converter.
Laboratory Measurement Equipment
The ADS1130IPW can serve as the acquisition element in bench instruments that measure resistive transducers with low-frequency signals. Its 18-bit resolution, onboard oscillator, and integrated low-noise gain amplifier create a compact measurement front end, while the 80 SPS rate is suitable for calibrated static readings and controlled ramps. For laboratory accuracy, use a stable excitation source, shield sensitive bridge nodes, maintain consistent return paths, and perform gain and offset calibration after thermal stabilization.
Process-Control Sensing
Slowly varying process variables can be represented by a resistive bridge when the measurement requires differential excitation and low-noise signal conditioning. The ADS1130IPW provides one 18-bit delta-sigma channel at 80 SPS, making it suitable for supervisory sensing rather than fast feedback loops. Place the converter near the bridge input to minimize sensitive-node routing, and separate analog and digital return currents to reduce coupling. The system response time must be compared with the control loop requirements because digital filtering adds latency.
工程參考資料,適用於 ADS1130IPW — 比較、設計指引及合規資訊。
選型指南
設計說明
Route the bridge excitation, bridge return, and differential input as a compact, continuous analog path. Keep the ADS1130IPW close to the bridge connection and keep switching-regulator traces, high-current paths, and digital clock lines away from the sensitive input nodes. A solid ground plane can help, but analog and digital return currents should be organized so bridge current does not share paths with digital output currents.
Do not select the gain solely from the ADC resolution. First calculate the maximum bridge differential voltage at full scale, then verify that this voltage and its polarity remain within the selected gain and input range at the worst-case excitation, tolerance, and temperature conditions. Inadequate headroom can clip the signal, while excessive gain can amplify offsets and common-mode error.
The 18-bit conversion resolution does not eliminate analog-layout errors such as thermoelectric offsets, excitation ripple, or ground disturbances. Use a stable excitation source, maintain symmetrical bridge connections, and allow the assembly to reach thermal equilibrium before precision calibration. Apply digital averaging only after establishing the required update time; each additional conversion extends the measurement latency.
合規資訊
The manufacturer product page and ordering listing identify the ADS1130IPW as an active 16-pin TSSOP device, but the retrieved excerpts do not state specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals statuses.