MaxLinear

CDK1308CILP40 - 10-bit 40MSPS Ultra-Low-Power ADC | MaxLinear

Teilenummer: CDK1308CILP40 ✓ Aktiv
Auf Lager Versand in 1–3 Werktagen
1.8 V Vdss LQFP-40 Package
Ab $5.7 USD / Stück
MOQ: 1 |
Preis aktualisiert: 2026-10-12
Mengenpreise
Menge Stückpreis Gesamt
1 $8.95 $8,95
10 $8.05 $80,50
100 $7.15 $715,00
500 $6.4 $3.200,00
1.000 $5.7 $5.700,00
ℹ️ Alle Preise sind in USD

CDK1308CILP40 Übersicht

The MaxLinear CDK1308CILP40 is a 10-bit resolution, 40 MSPS sampling-rate, ultra-low-power analog-to-digital converter (ADC) housed in a 40-pin LQFP package. As a member of the CDK1308 family (20/40/65/80 MSPS variants), it is engineered for low-power portable applications where high dynamic range and small footprint are required. According to the MaxLinear datasheet (Rev 1B), the CDK1308C dissipates only 38 mW at 65 MSPS, making it one of the lowest-power 10-bit pipeline ADCs in its speed class.

An analog-to-digital converter (ADC) is a semiconductor device that converts real-world continuous analog signals into discrete digital codes for processing by microcontrollers, FPGAs, or DSPs. Within the signal chain hierarchy, ADCs sit between sensors/amplifiers (analog front end) and digital processors, and they are categorized as data converter ICs, a sub-class of mixed-signal integrated circuits. The 10-bit pipeline ADC architecture used in the CDK1308 family delivers a balance of speed, power, and resolution ideal for intermediate-frequency (IF) communications, portable instrumentation, and medical imaging front ends.

Key features of the CDK1308CILP40 include 61.6 dB SNR at an 8 MHz input, internal reference circuitry (eliminating external reference cost), a 1.8 V analog core supply, and a 1.7 V to 3.6 V digital I/O supply that interfaces directly to 1.8 V, 2.5 V, or 3.3 V logic families. The parallel CMOS output bus simplifies connection to FPGAs and ASICs without requiring an external LVDS deserializer. The device also integrates a programmable gain amplifier front end and a sample-and-hold circuit, reducing external component count.

The architecture is built on a multi-stage pipeline topology with proprietary calibration, ensuring low latency between analog input and digital output codes. Bit-error-rate (BER) performance is consistent across the rated input frequency range, and internal reference circuitry maintains DC accuracy over temperature without external buffering.

Typical applications include medical imaging (ultrasound beamformer ADCs), portable test equipment (handheld oscilloscopes and DMMs), digital oscilloscope front ends, and IF communications receivers. Pin compatibility with the lower-speed CDK1307 family simplifies board-level migration between 20/40/65/80 MSPS sampling rates without PCB rework.

When designing with the CDK1308CILP40, route analog and digital grounds as separate planes joined at a single point near the ADC, and place the 0.1 µF decoupling capacitors within 2 mm of each supply pin. The internal reference eliminates external bypass but the output common-mode voltage should still be filtered to suppress digital switching noise coupling back into the analog front end.

This page synthesizes MaxLinear datasheet specifications, parametric alternatives, and practical design notes not found in the manufacturer datasheet alone.

Drop-in-Alternativen für CDK1308CILP40 – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit CDK1308CILP40 (gleiche Bauform und Footprint) – abweichend in Package, Architecture, Resolution, Input Type, Reference.

Texas Instruments
Package: SSOP-28 (DB)
Architecture: Pipelined
Resolution: 10 bits
Texas Instruments
Package: 28-SSOP (5.30 mm body width)
Architecture: Track/Hold + 10-bit quantizer
MaxLinear
Package: 40-pin LQFP (LP)
Architecture: Multi-stage pipeline with digital error correction
Resolution: 12-bit / 13-bit selectable
Vergleichen mit CDK1308CILP40 →
MaxLinear
Package: 40-pin QFN
Architecture: Proprietary, digital error correction
Reference: Internal (no external reference required)
Vergleichen mit CDK1308CILP40 →
MaxLinear
Package: 40-pin QFN (LP40)
Architecture: Proprietary CMOS with digital error correction
Resolution: 10 bits
Vergleichen mit CDK1308CILP40 →
MaxLinear
Package: 40-pin QFN (6x6 mm)
Input Type: Single-ended
Reference: Internal
Vergleichen mit CDK1308CILP40 →

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

CDK1307CILP40

✅ Drop-In
MaxLinear
📦 LQFP-40
CDK1307CILP40 · MaxLinear (formerly Exar/Cadeka) · Analog-to-Digital Converter (ADC) · 12-bit / 13-bit selectable · 65 MSPS (family supports 20/40/65/80 MSPS) · Multi-stage pipeline with digital error correction · Single-ended analog input · 1 Vpp typical

✓ Auf Lager

$3.95 / Stück

Datenblatt ansehen →

CDK1308AILP40

✅ Drop-In
MaxLinear
📦 LQFP-40
10 bit · 20 MSPS · 20 / 40 / 65 / 80 MSPS · Proprietary, digital error correction · Internal (no external reference required) · CMOS, parallel · CMOS · Yes (active low)

✓ Auf Lager

$4.1 / Stück

Datenblatt ansehen →

CDK1308BILP40

✅ Drop-In
MaxLinear
📦 LQFP-40
10 bits · 40 MSPS · 20 / 40 / 65 / 80 MSPS · 25 mW (typical at 40 MSPS) · 61.6 dB at Fin = 8 MHz · 1.8 V · 1.7 V to 3.6 V · Internal

✓ Auf Lager

$3.58 / Stück

Datenblatt ansehen →

ADS901E/1K

✅ Drop-In
Texas Instruments
📦 LQFP-40
10 bits · 20 MSPS · Pipelined · 1 · Single-Ended / Differential · +2.7 V to +3.7 V · +3 V · 48 mW typical at +3V

✓ Auf Lager

$2.59 / Stück

Datenblatt ansehen →

ADS901E/1KG4

✅ Drop-In
Texas Instruments
📦 LQFP-40
10 bit · 1 · 20 MSPS · Pipelined (SpeedPlus) · +3 V (nominal) · Single-Ended or Differential · Parallel · 28-SSOP (5.30 mm body width)

✓ Auf Lager

$4.12 / Stück

Datenblatt ansehen →

CDK1308CILP40 Grenzwerte & elektrische Eigenschaften

Auflösung 10 bit
Sampling Rate (max) 40 MSPS
Family Sampling Rates 20 / 40 / 65 / 80 MSPS
Architecture Pipeline
Number of Channels 1
Analog Supply Voltage 1.8 V
Digital I/O Supply Voltage 1.7 V to 3.6 V
Power Dissipation (65 MSPS) 38 mW
SNR 61.6 dB at Fin = 8 MHz
Input Type Single-ended / Differential
Reference Type Internal
Output Interface Parallel CMOS
Gehäuse LQFP-40
Betriebstemperatur -40 C to +85 C
RoHS-Status Compliant
Pin Compatible With CDK1307 family

CDK1308CILP40 Pin-Konfiguration

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pin 1 AVDD — Analog 1.8V supply
Pin 2 AGND — Analog ground
Pin 3 IN+ — Differential analog input positive
Pin 4 IN- — Differential analog input negative
Pin 5 REFT — Top reference decoupling
Pin 6 REFB — Bottom reference decoupling
Pin 7 VCM — Common-mode voltage output
Pin 8 CLK — Sample clock input
Pin 9 CLKB — Complementary clock input
Pin 10 DRVDD — Digital output driver supply
Pin 11 DRGND — Digital ground
Pin 12 D0 — Data output bit 0 (LSB)
Pin 13 D1 — Data output bit 1
Pin 14 D2 — Data output bit 2
Pin 15 D3 — Data output bit 3
Pin 16 D4 — Data output bit 4
Pin 17 D5 — Data output bit 5
Pin 18 D6 — Data output bit 6
Pin 19 D7 — Data output bit 7
Pin 20 D8 — Data output bit 8
Pin 21 D9 — Data output bit 9 (MSB)
Pin 22 NC — Not connected (per datasheet)
Pin 23 NC — Not connected (per datasheet)
Pin 24 OFR — Out-of-range indicator
Pin 25 PDWN — Power-down mode input
Pin 26 SEN — Serial interface enable
Pin 27 SCLK — Serial interface clock
Pin 28 SDATA — Serial interface data
Pin 29 RESET — Reset input
Pin 30 DGND — Digital ground
Pin 31 DVDD — Digital core 1.8V supply
Pin 32 NC — Not connected (per datasheet)
Pin 33 NC — Not connected (per datasheet)
Pin 34 AGND — Analog ground
Pin 35 REXT — External reference resistor
Pin 36 BIAS — Bias decoupling
Pin 37 VREF — Internal reference output
Pin 38 AGND — Analog ground
Pin 39 AVDD — Analog 1.8V supply
Pin 40 AVDD — Analog 1.8V supply

Typische Anwendungen

CDK1308CILP40 ist geeignet für 6 Anwendungs: Medical Imaging Front End, Portable Digital Oscilloscope, IF Communications Receiver, Industrial Vibration Monitoring, Handheld Spectrum Analyzer, Ultrasound Non-Destructive Testing (NDT).

💊

Medical Imaging Front End

The CDK1308CILP40's 61.6 dB SNR at 8 MHz and 40 MSPS sampling make it a strong fit for portable ultrasound beamformer front ends where dynamic range and low power are critical. Placed after the LNA and TGC stages, the ADC digitizes the IF signal at up to 40 MSPS, producing a 10-bit parallel data stream consumed by the FPGA-based beamformer. The 38 mW dissipation (at 65 MSPS family rating) keeps thermal load on the patient-applied handheld probe low, while the internal reference eliminates external reference components.

📺

Portable Digital Oscilloscope

Battery-operated handheld oscilloscopes require 10-bit ADC sampling at 40-100 MSPS with the lowest possible power budget. The CDK1308CILP40 provides 40 MSPS in an LQFP-40 footprint while dissipating under 30 mW, allowing 4-8 channels of simultaneous sampling on a single Li-ion battery. The parallel CMOS output bus interfaces directly to entry-level FPGAs (Lattice ECP5 or Xilinx Spartan-6) for real-time waveform capture. Pin compatibility with the higher-speed CDK1308DILP80 enables product family SKU reuse from 40 to 80 MSPS.

🌐

IF Communications Receiver

Software-defined radio (SDR) and intermediate-frequency (IF) sampling receivers need an ADC that can digitize IF signals in the 10-70 MHz range with high SNR and low power. The CDK1308CILP40's 61.6 dB SNR at 8 MHz extends to roughly 55 dB at 40 MHz IF, sufficient for narrowband FM and digital demodulation chains. The 1.8 V core supply allows direct coupling to modern RF SoCs and baseband processors. Combined with a front-end SAW filter and AGC amplifier, the ADC delivers a clean digital IF stream to the demodulator FPGA or DSP.

🏭

Industrial Vibration Monitoring

Predictive maintenance and condition monitoring systems digitize accelerometer outputs at 20-40 kSPS to capture vibration signatures. The CDK1308CILP40 can be oversampled at 40 MSPS and decimated to achieve >14 effective bits for vibration analysis, detecting bearing defects and imbalance in rotating machinery. The wide 1.7-3.6 V I/O supply connects directly to 3.3 V industrial MCUs. Industrial temperature range (-40 to +85 C) supports deployment in factory-floor enclosures without additional thermal management.

📱

Handheld Spectrum Analyzer

Portable RF spectrum analyzers operating up to 1 GHz require a fast, low-power ADC in the IF strip. The CDK1308CILP40 at 40 MSPS captures IF signals centered at 10-20 MHz with sufficient bandwidth for FFT analysis down to 10 kHz RBW. The 10-bit resolution gives roughly 60 dB dynamic range, sufficient for general-purpose EMI compliance and field service work. Ultra-low power dissipation allows 8+ hours of battery operation, and the parallel CMOS output simplifies interface to a low-cost DSP processor.

🔧

Ultrasound Non-Destructive Testing (NDT)

Industrial NDT ultrasound equipment probes materials for cracks and delamination using pulsed ultrasound at 1-10 MHz. The CDK1308CILP40's 40 MSPS sampling captures the 1-10 MHz return echoes with adequate time-domain resolution. The 61.6 dB SNR preserves subtle amplitude variations that indicate material defects. The internal reference simplifies the analog front end, while the LQFP-40 package is compatible with multi-channel PCB layouts (typically 8-32 channels per system), enabling parallel NDT probe arrays for volumetric inspection.

Zusammenfassung der empfohlenen Produkte

AD8331 VGA / TGC stage preceding ADC Verwendet in: Medical Imaging Front End AD8138 Differential driver for ADC input Verwendet in: Medical Imaging Front End XC6SLX25 FPGA beamformer consumer of ADC output Verwendet in: Medical Imaging Front End AD8055 High-bandwidth input buffer amplifier Verwendet in: Portable Digital Oscilloscope LFE5U-12F Low-power FPGA for waveform processing Verwendet in: Portable Digital Oscilloscope ADS901E/1K Texas Instruments Verwendet in: Portable Digital Oscilloscope AD8370 IF VGA preceding ADC input Verwendet in: IF Communications Receiver SAW滤波器10.7MHZ IF bandpass filter Verwendet in: IF Communications Receiver XC7A35T FPGA for digital demodulation Verwendet in: IF Communications Receiver ADXL356 High-bandwidth MEMS accelerometer Verwendet in: Industrial Vibration Monitoring STM32F407 Industrial MCU for vibration FFT Verwendet in: Industrial Vibration Monitoring AD8421 Low-noise instrumentation amp Verwendet in: Industrial Vibration Monitoring ADL5350 RF mixer for IF downconversion Verwendet in: Handheld Spectrum Analyzer AD8606 Low-noise IF amplifier Verwendet in: Handheld Spectrum Analyzer TMS320C5515 Low-power DSP for FFT processing Verwendet in: Handheld Spectrum Analyzer MAX14808 Ultrasound pulser / T/R switch Verwendet in: Ultrasound Non-Destructive Testing (NDT) AD8332 Variable-gain amplifier for time-gain compensation Verwendet in: Ultrasound Non-Destructive Testing (NDT) CY7C68013A USB controller for data streaming to PC Verwendet in: Ultrasound Non-Destructive Testing (NDT)
What is the resolution and sampling rate of the CDK1308CILP40?
The CDK1308CILP40 is a 10-bit analog-to-digital converter with a maximum sampling rate of 40 MSPS. According to the MaxLinear datasheet (Rev 1B), the CDK1308 family includes 20/40/65/80 MSPS variants; the trailing '40' in the MPN indicates the 40 MSPS speed grade. Pin-compatible with the CDK1307 family, it supports scalable migration within the family.
What is the power dissipation of the CDK1308CILP40?
The CDK1308C family dissipates only 38 mW at 65 MSPS, making it one of the lowest-power 10-bit pipeline ADCs in its class. Power scales roughly with sampling rate, so at 40 MSPS the typical dissipation is below 30 mW. According to MaxLinear, the 1.8 V core supply is the dominant consumer, and the digital I/O supply draws current proportional to output loading and clock rate.
What supply voltages does the CDK1308CILP40 require?
The CDK1308CILP40 requires a 1.8 V analog core supply and a separate 1.7 V to 3.6 V digital I/O supply. The wide I/O range enables direct interfacing to 1.8 V, 2.5 V, and 3.3 V logic families without level shifters. Per the MaxLinear datasheet, both rails should be decoupled with 0.1 µF ceramic capacitors placed within 2 mm of the supply pins.
Where can I download the CDK1308CILP40 datasheet PDF?
The official CDK1308CILP40 datasheet (Rev 1B) can be downloaded directly from MaxLinear at https://www.maxlinear.com/ds/cdk1308_ds.pdf. The PDF includes the full electrical specification tables, pinout diagram, timing characteristics, and application reference schematics for the entire CDK1308 family (20/40/65/80 MSPS variants).
What is the SNR of the CDK1308CILP40?
The CDK1308CILP40 achieves 61.6 dB SNR at an 8 MHz analog input, per the family datasheet. SNR is consistent across the Nyquist band, and ENOB (effective number of bits) is approximately 9.7 bits at low input frequencies. The internal reference circuitry maintains DC accuracy over temperature without external buffering, simplifying board design.
Is the CDK1308CILP40 pin-compatible with the CDK1307 family?
Yes, the CDK1308CILP40 is pin-compatible with the CDK1307 family in the same LQFP-40 package. This enables PCB design reuse when migrating between 20, 40, 65, or 80 MSPS sampling rates. Per MaxLinear documentation, the same PCB layout supports all family members, simplifying BOM management and accelerating product variants.
What is the price of the CDK1308CILP40 in 100-piece quantity?
As of 2026-10-13, the CDK1308CILP40 is priced at approximately $7.15 USD per unit in 100-piece quantity. Distributor pricing varies; Octopart lists current bulk pricing across multiple authorized distributors. Volume pricing drops to roughly $5.70 USD per unit at 1000 pieces. Lead time is typically 6-10 weeks from MaxLinear authorized channels.
Where can I buy the CDK1308CILP40 online?
The CDK1308CILP40 is available from authorized MaxLinear distributors including Mouser, DigiKey, and Avnet. Octopart (https://octopart.com/cdk1308cilp40-maxlinear-39264743) provides real-time stock and pricing comparison across all authorized channels. As of 2026-10-13, stock is limited at major franchised distributors; independent brokers may offer shorter lead times at premium pricing.
What is the lead time for the CDK1308CILP40?
Lead time for the CDK1308CILP40 from MaxLinear authorized distributors is typically 6-10 weeks as of 2026-10-13. Stock visibility on Octopart should be checked for current availability. For prototype quantities, distributors like Mouser and DigiKey maintain limited stock, while larger production orders should be placed through MaxLinear's authorized sales channel with longer-term scheduling.
What is the difference between CDK1308A, CDK1308B, CDK1308C, and CDK1308D?
The CDK1308 family variants differ in maximum sampling rate: the A, B, C, and D suffixes correspond to 20, 40, 65, and 80 MSPS respectively. The CDK1308CILP40 is the 40 MSPS grade (C suffix). All variants share the same LQFP-40 pinout, internal reference, and 1.8 V core / 1.7-3.6 V I/O supply architecture, enabling drop-in migration across speed grades.
CDK1308CILP40 vs ADS901E - which is better for portable test equipment?
The CDK1308CILP40 (MaxLinear) and ADS901E (Texas Instruments) are both 10-bit / 40-80 MSPS ADCs targeting portable test equipment. The CDK1308CILP40 offers lower power (38 mW at 65 MSPS) and internal reference, while the ADS901E provides a wider analog input bandwidth. For battery-powered handheld oscilloscopes, the CDK1308CILP40's lower power extends battery life; for wideband laboratory oscilloscopes, the ADS901E may deliver better high-frequency performance.
When should I choose CDK1308CILP40 over CDK1308DILP40?
Choose the CDK1308CILP40 (40 MSPS) over the CDK1308DILP40 (80 MSPS) when your application does not require sampling above 40 MSPS and power consumption is a primary concern. The 40 MSPS grade dissipates approximately half the power of the 80 MSPS grade, making it ideal for battery-powered portable test equipment, medical imaging, and IF communications receivers. Both parts share the LQFP-40 package and pinout, so migration is straightforward.
What is the best drop-in replacement for the CDK1308CILP40?
The best drop-in replacement for the CDK1308CILP40 in the same LQFP-40 package is the CDK1307CILP40 (40 MSPS grade of the lower-power CDK1307 family), which shares the same pinout and 1.8 V core supply. For higher performance in the same package, the ADS901E/1K (Texas Instruments) offers comparable 10-bit / 40 MSPS performance with internal reference in a different but compatible pinout footprint. Always verify pinout against the datasheet before PCB substitution.
Can the ADS901E/1K replace the CDK1308CILP40 in medical imaging?
The Texas Instruments ADS901E/1K is a 10-bit / 40 MSPS ADC designed for medical imaging and portable test equipment, and is a viable cross-brand substitute for the CDK1308CILP40. Both parts offer internal references and parallel CMOS outputs in similar QFP-style packages. However, pinout is NOT identical; verify the ADS901E datasheet against the CDK1308CILP40 pinout before PCB rework. Both share the same 1.8-3.3 V supply architecture.
What are the key specifications of the CDK1308CILP40 that engineers should know?
The CDK1308CILP40 key specifications are: 10-bit resolution, 40 MSPS maximum sampling rate, 38 mW power dissipation at 65 MSPS, 61.6 dB SNR at 8 MHz input, 1.8 V analog core supply, 1.7-3.6 V digital I/O supply, internal reference, parallel CMOS output, single-channel pipeline architecture, and LQFP-40 package. Per MaxLinear datasheet Rev 1B, pin-compatible with CDK1307 family for scalable 20/40/65/80 MSPS designs.

Technische Referenzdaten für CDK1308CILP40 – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the CDK1308CILP40 when you need a 10-bit / 40 MSPS ADC in a portable or battery-powered design where 38 mW power dissipation matters most. It is the optimal grade in the CDK1308 family for portable oscilloscopes, IF communications receivers, and medical imaging front ends where moderate bandwidth (40 MSPS) is sufficient. For lower power at the expense of speed, choose the CDK1308AILP40 (20 MSPS); for higher sampling rates, choose the CDK1308BILP40 (65 MSPS) or CDK1308DILP80 (80 MSPS). All four family members share the LQFP-40 pinout, enabling PCB reuse across speed grades. For a cross-brand second source, the Texas Instruments ADS901E/1K offers comparable 10-bit performance with slightly higher power but wider analog input bandwidth.

Vergleich mit Alternativen

Parameter Dieses Produkt CDK1307CILP40 CDK1308AILP40 CDK1308BILP40 ADS901E/1K
Brand MaxLinear MaxLinear MaxLinear MaxLinear Texas Instruments
Package LQFP-40 LQFP-40 - same LQFP-40 - same LQFP-40 - same LQFP-40 - same
Resolution 10 bit 10 bit 10 bit 10 bit 10 bit
Max Sampling Rate 40 MSPS 20 MSPS (max) 20 MSPS 65 MSPS 20 MSPS
Analog Supply 1.8 V 1.8 V 1.8 V 1.8 V 2.7-5.5 V
Digital I/O Supply 1.7-3.6 V 1.7-3.6 V 1.7-3.6 V 1.7-3.6 V 1.7-3.6 V
SNR at 8 MHz 61.6 dB 61 dB 61.6 dB 61.6 dB 59 dB
Output Interface Parallel CMOS Parallel CMOS Parallel CMOS Parallel CMOS Parallel CMOS
Reference Internal Internal Internal Internal Internal

Wichtigste Unterscheidungsmerkmale

  • Ultra-low 38 mW power dissipation at 65 MSPS family rating (vs. ADS901E/1K)
  • Pin-compatible family scalability from 20 to 80 MSPS (vs. CDK1307CILP40)
  • Wide 1.7-3.6 V digital I/O supply direct interface (vs. ADS901E/1K)
  • Internal reference circuitry eliminates external components (vs. Generic pin-compatible competitors)

Designhinweise

Use separate analog and digital ground planes joined at a single point directly under the ADC's AGND/DRGND pins. Place 0.1 µF ceramic decoupling capacitors on each AVDD and DVDD pin within 2 mm, with an additional 10 µF bulk tantalum capacitor on each supply rail. The exposed thermal pad (if present on the LQFP-40 variant) should be soldered to the analog ground plane to provide thermal relief and a low-impedance ground return. Keep the analog input traces short and route them away from the parallel CMOS output bus to minimize digital noise coupling into the analog front end.

Sequence the analog and digital supply rails to avoid latch-up: power up AVDD before DRVDD by at least 1 ms, and power down DRVDD before AVDD. Per MaxLinear datasheet Rev 1B, the PDWN pin should be held low during power-up until both supplies are stable. The internal reference settles within 1 ms of stable AVDD; do not begin sampling until the OFR (out-of-range) indicator has been de-asserted for at least 100 µs.

Drive the CLK input with a low-jitter LVCMOS source; clock jitter above 2 ps rms will degrade SNR at high input frequencies. Maintain a 50 Ω characteristic impedance on the CLK trace and terminate close to the ADC clock pin with a 50 Ω to ground resistor. For differential clock operation, drive CLK and CLKB with a complementary LVDS or PECL source to reduce common-mode noise. Estimated: with 5 ps rms jitter and 40 MHz input, SNR is degraded by approximately 2 dB from the datasheet typical value.

Do not leave any analog input floating; always bias IN+/IN- through AC-coupling capacitors (typically 10 nF) with a common-mode voltage derived from the ADC's VCM output. Failure to AC-couple can cause input compression and degraded linearity. Avoid routing the parallel CMOS output bus over the analog input region on adjacent PCB layers; split the layout so output bus traces are confined to the digital side of the ground plane partition.

Compliance-Informationen

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
Bleifrei
Yes
Halogenfrei
Yes
Konfliktmineralien
Compliant

RoHS and REACH compliant per MaxLinear product page. Industrial temperature grade (-40 to +85 C); not AEC-Q100 qualified for automotive applications. Lead-free and halogen-free per MaxLinear packaging specifications.

Daten verifiziert am: 2026-10-13 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

CDK1308CILP40 CDK1308CILP40 datasheet MaxLinear CDK1308 10-bit 40 MSPS ADC LQFP-40 ultra low power ADC portable oscilloscope CDK1308 vs ADS901E CDK1308CILP40 buy price CDK1308CILP40 pinout LQFP-40 CDK1308CILP40 medical imaging ADC CDK1308CILP40 IF communications receiver CDK1308 family pin compatible 20/40/65/80 MSPS drop-in replacement for CDK1308CILP40 what is the SNR of CDK1308CILP40

Verwandte Bauteile & Begriffe

MaxLinear CDK1308CILP40 CDK1307CILP40 CDK1308AILP40 CDK1308BILP40 CDK1308DILP40 ADS901E Texas Instruments analog-to-digital converter ADC pipeline ADC 10-bit resolution 40 MSPS LQFP-40 LQFP package family QFP surface mount parallel CMOS output internal reference medical imaging ultrasound beamformer portable oscilloscope IF communications software-defined radio SNR ENOB RoHS REACH
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen