DG406DW - 16-Channel CMOS Analog Multiplexer | Vishay
Teilenummer: DG406DW ✓ AktivDG406DW Übersicht
An analog multiplexer is a semiconductor switch that connects multiple analog signal sources to one shared processing channel. It belongs to the interface IC hierarchy and reduces the number of input pins required by measurement, test, and routing systems. The DG406 is designed for single-ended routing, while companion devices in the DG406/DG407 family address differential multiplexing requirements.
Key features include break-before-make switching, which prevents two sources from momentarily being connected together during channel changes. The maximum on-resistance of 100 ohm helps limit signal attenuation in high-impedance measurement circuits. Low charge injection of 15 pC reduces the voltage disturbance generated when the address changes, and the 200 ns transition time supports relatively fast data acquisition.
Internally, the DG406 uses CMOS switching elements controlled by four address inputs and an inhibit function. Address decoding determines which of the 16 source channels connects to the common drain. Break-before-make operation protects sensitive measurement front ends from accidental source-to-source shorts, while the low 0.2 mW power dissipation suits remote and battery-operated instrumentation.
Typical uses include high-speed data acquisition, audio signal switching and routing, automated test equipment, avionics systems, and remote instrumentation. The device can also serve in instrumentation systems that scan multiple sensor outputs, provided the source impedance, acquisition time, charge injection, and supply voltage are evaluated together.
When laying out a DG406DW circuit, place the common output and selected input traces away from digital address lines, provide a solid ground reference, and use the pin-description table in the manufacturer datasheet when assigning PCB tracks. Check off-state leakage and switch capacitance before designing a high-impedance front end.
This page combines the manufacturer datasheet characteristics, package information, application guidance, comparison parameters, and practical design notes to support component selection, PCB implementation, and sourcing decisions for the DG406DW.
Drop-in-Alternativen für DG406DW – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
DG406DW-E3
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
DG406DW Technische Daten
| Multiplexer Configuration | 16:1 single-ended |
| Number of Channels | 16 channels |
| Address Inputs | 4 binary address inputs |
| Maximum On-Resistance | 100 ohm |
| Nominal On-Resistance | 50 ohm |
| Charge Injection | 15 pC |
| Transition Time | 200 ns |
| Power Dissipation | 0.2 mW |
| Maximum Supply Voltage | 44 V |
| Supply Capability | Single supply |
| Switching Action | Break-before-make |
| Gehäuse | 28-SOIC |
| Montageart | Surface mount |
| Channel Matching | 8 ohm maximum |
| On-Resistance Flatness | 9 ohm maximum |
DG406DW Pin-Konfiguration
| Pin 1 | S1 — Source terminal for channel 1 |
| Pin 2 | S2 — Source terminal for channel 2 |
| Pin 3 | S3 — Source terminal for channel 3 |
| Pin 4 | S4 — Source terminal for channel 4 |
| Pin 5 | D1 — Drain terminal for channel 1 |
| Pin 6 | D2 — Drain terminal for channel 2 |
| Pin 7 | D3 — Drain terminal for channel 3 |
| Pin 8 | D4 — Drain terminal for channel 4 |
| Pin 9 | S5 — Source terminal for channel 5 |
| Pin 10 | S6 — Source terminal for channel 6 |
| Pin 11 | S7 — Source terminal for channel 7 |
| Pin 12 | S8 — Source terminal for channel 8 |
| Pin 13 | D5 — Drain terminal for channel 5 |
| Pin 14 | D6 — Drain terminal for channel 6 |
| Pin 15 | D7 — Drain terminal for channel 7 |
| Pin 16 | D8 — Drain terminal for channel 8 |
| Pin 17 | INH — Inhibit input |
| Pin 18 | V+ — Positive supply input |
| Pin 19 | A0 — Address input 0 |
| Pin 20 | A1 — Address input 1 |
| Pin 21 | A2 — Address input 2 |
| Pin 22 | A3 — Address input 3 |
| Pin 23 | D — Common drain output |
| Pin 24 | V- — Negative supply or ground connection |
| Pin 25 | S9 — Source terminal for channel 9 |
| Pin 26 | S10 — Source terminal for channel 10 |
| Pin 27 | S11 — Source terminal for channel 11 |
| Pin 28 | S12 — Source terminal for channel 12 |
Typische Anwendungen
DG406DW ist geeignet für 6 Anwendungs: Multichannel Data Acquisition, Audio Signal Switching and Routing, Automated Test Equipment Signal Routing, Remote Instrumentation and Sensor Scanning, Avionics and Multichannel Signal Routing, Industrial Control Signal Multiplexing.
Multichannel Data Acquisition
The DG406DW suits systems that scan 16 single-ended sensor or test points into one shared acquisition channel. Its 200 ns transition time, 50 ohm nominal on-resistance, and 100 ohm maximum on-resistance provide a practical basis for fast channel selection, while break-before-make operation prevents two driven sources from being shorted during address changes. The 15 pC charge injection figure must be included in the settling calculation for high-impedance front ends. Use the common output and selected source route as a short analog trace, and verify the external acquisition time against the actual source impedance. The device is especially useful in compact instrumentation where routing 16 analog inputs individually to a converter would otherwise require substantially more board area.
Empfohlen
Audio Signal Switching and Routing
The DG406DW can route one of 16 single-ended audio sources to a common amplifier or processing path. The 100 ohm maximum on-resistance is low enough for many line-level signal paths, and the 15 pC charge injection limits the switching transient that can appear as a click when the address changes. The 200 ns transition time is much faster than the response of many audio amplifiers, although system-level settling still depends on capacitance and the following stage. In a mixer or selector circuit, use a grounded return plane and keep the analog route away from digital address lines. Check the acceptable common-mode input range at the chosen supply voltage and consider an input buffer when driving a high-impedance volume control.
Empfohlen
Automated Test Equipment Signal Routing
The DG406DW is appropriate for test systems that connect one of 16 measured or stimulus nodes to shared instrumentation. Its 16-channel architecture reduces the connector and routing count, while the 100 ohm maximum on-resistance and 200 ns transition time support low-frequency and medium-speed measurements. Break-before-make switching is important when different test sources may be active during relay-style transitions. The 8-ohm maximum channel-matching and 9-ohm maximum flatness specifications help when several channels are compared during calibration. Keep the selected analog path compact and route the four address inputs as a controlled digital group. Verify leakage, source impedance, and acquisition settling before using the device for very high-impedance or precision bridge measurements.
Empfohlen
Remote Instrumentation and Sensor Scanning
The DG406DW fits remote or battery-operated instrumentation because its stated power dissipation is only 0.2 mW and it supports single-supply operation. Sixteen single-ended inputs can be scanned into one common measurement channel, reducing the number of external signal connections and simplifying enclosure wiring. The 44 V maximum supply rating provides headroom for protected industrial input networks, but the actual input range must be checked against the chosen supply. The 200 ns transition time allows the control system to change addresses rapidly, while 15 pC charge injection becomes more significant as sensor impedance rises. Use low-leakage protection networks and a high-impedance buffer where the source cannot tolerate switching transients.
Empfohlen
Avionics and Multichannel Signal Routing
The DG406DW supports avionics applications that require selection among multiple single-ended signal paths. Its 16 channels, four-bit address interface, 44 V maximum supply rating, and break-before-make operation suit centralized signal-routing architectures where avoiding unintended channel shorts is essential. The manufacturer identifies avionics among the intended applications for the DG406 and DG407 family. Actual aircraft use still depends on the specific orderable configuration, qualification status, and operating-temperature requirements. Keep the analog routing symmetrical to reduce timing and offset differences, provide filtering appropriate for the protected signal source, and verify the logic thresholds of the address and inhibit inputs against the controlling system. Review the manufacturer datasheet for qualification and absolute-maximum requirements before release.
Empfohlen
Industrial Control Signal Multiplexing
The DG406DW can consolidate 16 low-level control or sensor lines into one analog channel for an industrial controller. The single-supply capability and 0.2 mW power dissipation reduce system overhead, while the 50 ohm nominal and 100 ohm maximum on-resistance preserve signal integrity across moderate source impedances. Use break-before-make behavior when switching between outputs that remain active. The 15 pC charge injection transient can disturb a high-impedance comparator input, so allow adequate settling time or add a sampling-and-hold stage. Route the common analog node away from switching power stages, use a continuous ground reference, and keep address routing short. Confirm the input common-mode range and logic levels for the selected supply voltage.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für DG406DW – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | DG406DW-E3 |
|---|---|---|
| Manufacturer | Vishay Intertechnology | Vishay Intertechnology |
| Package | 28-SOIC | 28-SOIC - same |
| Multiplexer Configuration | 16:1 single-ended | 16:1 single-ended - same |
| Number of Channels | 16 channels | 16 channels - same |
| Maximum On-Resistance | 100 ohm | 100 ohm - same |
| Charge Injection | 15 pC | 15 pC - same |
| Transition Time | 200 ns | 200 ns - same |
| Switching Action | Break-before-make | Break-before-make - same |
| Address Inputs | 4 binary inputs | 4 binary inputs - same |
Wichtigste Unterscheidungsmerkmale
- Directly documented orderable configuration (vs. DG406DW-E3)
- Sixteen single-ended channels in one package (vs. DG406DW-E3)
- Low switching disturbance for analog routing (vs. DG406DW-E3)
Designhinweise
Treat the selected source and common drain as a matched analog path. Keep these traces short, avoid stubs, and provide a continuous ground reference beneath the analog region. The 15 pC charge injection produces a transient when the address changes; with high source impedance, that pulse can exceed the signal being measured. Add an input buffer or a sample-and-hold stage when the source impedance makes the switching disturbance unacceptable.
Separate the four address inputs, inhibit control, and supply connections from the common analog output to reduce capacitive coupling into the measurement path. Route the address group consistently and place the device close to the signal source when source impedance is high. Use the pin-description table in the manufacturer datasheet to confirm that the selected source terminal and its corresponding drain terminal are connected to the intended channel.
Do not assume that a 200 ns transition time alone determines the usable sampling rate. Acquisition time must also include amplifier settling, source impedance, capacitance, and charge injection recovery. Break-before-make prevents momentary input shorts, but it does not remove the switching transient at the common output. Validate the complete signal chain with the highest-impedance source and the fastest intended address sequence.
Decouple the supply pins locally with a ceramic capacitor and provide the ground return specified in the application circuitry. Although the mux power dissipation is specified at 0.2 mW, external load current and nearby circuitry can determine the temperature rise of the assembly. Check the supply rating, allowable input voltage, and absolute-maximum limits in the Vishay DG406 datasheet before applying protection-network voltages.
Compliance-Informationen
The DG406 family is listed as production on the manufacturer product page. The E3 ordering suffix identifies a RoHS-compliant configuration, but the exact compliance fields for the base DG406DW require confirmation on the Request a Quote form.