ICL7116CQH+D - 3.5-Digit LCD ADC | Analog Devices
Teilenummer: ICL7116CQH+D ✓ AktivICL7116CQH+D Übersicht
An integrating analog-to-digital converter converts an analog input into a digital measurement by integrating the input over a defined interval and measuring the resulting time or counter value. The ICL7116 belongs to the ADC and DAC category of display-oriented mixed-signal semiconductors. It combines a high-input-impedance measurement front end with display decoding, segment drivers, a voltage reference, and clock circuitry in one monolithic device.
The ICL7116CQH+D provides a 3.5-digit measurement range with approximately 0.0015% maximum linearity error. It directly drives LCD displays rather than LED displays, eliminating a separate external display-driver stage in suitable meter designs. Its hold function distinguishes it from the related ICL7106 and adds useful control when a measurement must remain displayed or captured during a subsequent system action.
The device uses a dual-slope conversion method and includes onboard active components for polarity and digit drive, segment decoding, voltage reference, and clock operation. Its high input impedance is suited to sensors and measurement networks that cannot tolerate heavy loading. Because conversion speed depends on the selected integration cycle and oscillator arrangement, the application should use the timing and component-selection guidance in the manufacturer datasheet rather than treating the converter as a high-speed successive-approximation ADC.
Typical uses include handheld meters, laboratory instruments, panel meters, temperature displays, laboratory equipment, and industrial measurement panels. The direct LCD output and integrated conversion functions simplify a complete measurement instrument, while the hold input supports user-controlled sampling and display retention.
A successful design must provide the external reference, oscillator, input, display, and decoupling components required by the selected circuit topology. The PLCC package also requires careful PCB footprint alignment and adequate thermal dissipation because the converter can dissipate power as the supply-to-reference difference increases.
This page combines device specifications, package details, application guidance, replacement considerations, and a practical comparison of compatible family members. It is designed to help engineers evaluate the ICL7116CQH+D for a new panel-meter design or determine whether a related Maxim integrated converter can satisfy the required LCD, hold, package, and supply constraints.
Drop-in-Alternativen für ICL7116CQH+D – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit ICL7116CQH+D (gleiche Bauform und Footprint) – abweichend in Display Output, RoHS Status, Package, Supply Voltage, Temperature Grade.
ICL7106CQH+TD
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
ICL7117CQH
✅ Drop-In ⚠️ Spezifikationen ungeprüftPreis auf Anfrage
Datenblatt ansehen →ICL7137CQH
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →ICL7107CQH
✅ Drop-In ⚠️ Spezifikationen ungeprüft📋 Referenzalternative (nicht im Katalog)
ICL7116CQH
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
ICL7116CQH+D Grenzwerte & elektrische Eigenschaften
| ADC Architecture | Dual-slope integrating ADC |
| Display Resolution | 3.5 digits |
| Numeric Resolution | 16 bit |
| Maximum Linearity Error | 0.0015% |
| Versorgungsspannung | 9 V |
| Display Output | Direct LCD drive |
| Hold Function | Yes |
| Input Impedance | Very high input impedance |
| Temperature Grade | Commercial |
| Minimum Operating Temperature | 0 °C |
| Maximum Operating Temperature | 70 °C |
| Gehäuse | PLCC-44, 16.59 mm × 16.59 mm |
| Package Code | QCCJ |
| Terminal Count | 44 terminals |
| Terminal Form | J-bend |
| Package Shape | Square |
| Montageart | Surface mount |
| RoHS-Status | Compliant |
ICL7116CQH+D square Pinbelegungsleitfaden
Pinbelegung für ICL7116CQH+D (square-Gehäuse). Dieses analoge Bauteil verfügt über Eingangs-, Ausgangs- und Versorgungspins. Offset-Null-, Kompensations- und Enable-Pin-Konfigurationen entnehmen Sie dem Herstellerdatenblatt. Ideal für Signalaufbereitung und Verstärkerschaltungen.
Keine detaillierten Pinbelegungsdaten verfügbar für ICL7116CQH+D.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
ICL7116CQH+D ist geeignet für 6 Anwendungs: Digital Panel Meter, Laboratory Voltage Measurement, Industrial Temperature Display, Handheld Measurement Instrument, Weight Scale Indicator, Process Monitoring Readout.
Digital Panel Meter
The ICL7116CQH+D fits a digital panel meter because it combines a 3.5-digit dual-slope integrating ADC with direct LCD drive in one 44-pin PLCC device. The converter can measure a conditioned analog input and present the result without a separate display-driver IC, reducing system complexity. The approximately 0.0015% maximum linearity error is relevant to the converter itself, while the complete meter accuracy also depends on the input network, reference, timing components, calibration, and display quality. The hold input is useful when the reading must remain stable while another function is selected or recorded.
Empfohlen
Laboratory Voltage Measurement
The ICL7116CQH+D can form the measurement core of a laboratory voltage instrument when the input is conditioned to the converter's allowable range. Its 3.5-digit dual-slope format suits stable, readable instrument readings, while very high input impedance helps reduce loading on the source. The 9 V supply rating and direct LCD output simplify a dedicated meter architecture. For accuracy-critical work, engineers should account for reference tolerance, analog front-end offset and noise, integration timing, and calibration rather than attributing all measurement performance to the converter's 0.0015% maximum linearity specification.
Empfohlen
Industrial Temperature Display
The ICL7116CQH+D is appropriate for an industrial temperature display when a resistive sensor can be connected through a suitable bridge and signal-conditioning circuit. The high-input-impedance integrating front end helps avoid excessive sensor loading, and the integrated LCD drive provides a straightforward display path. The 0 °C to 70 °C commercial-temperature specification suits controlled indoor equipment but not unconditioned industrial environments. A robust design should include input protection, reference compensation, sensor lead-error compensation where needed, and recalibration intervals based on the complete measurement chain.
Empfohlen
Handheld Measurement Instrument
The ICL7116CQH+D suits handheld meters that prioritize readable numerical output over rapid successive-approximation conversion. Its integrated LCD drive and 3.5-digit dual-slope conversion support a compact meter architecture, while the hold pin allows the displayed value to be frozen during range or mode changes. The commercial-temperature range covers many indoor handheld products. Designers should evaluate display contrast under changing ambient light, input protection, reference startup behavior, power-consumption requirements, and the PCB area required by the PLCC-44 footprint before finalizing the enclosure and user interface.
Empfohlen
Weight Scale Indicator
The ICL7116CQH+D can support a weight-scale indicator when the load-cell signal is conditioned and scaled into the ADC input range. The 3.5-digit format is appropriate for compact commercial scales, and direct LCD drive simplifies the display subsystem. The hold function is useful during tare capture or when a measured value must remain visible. Real designs must account for excitation stability, mechanical vibration, temperature drift, bridge excitation noise, decimal-point placement, and calibration. Because the converter uses an integrating cycle, the update rate should be selected to balance readability against vibration rejection and measurement latency.
Empfohlen
Process Monitoring Readout
The ICL7116CQH+D can provide a local process-monitoring readout when a sensor or control-loop signal requires stable, human-readable measurement. Its direct LCD output avoids adding a separate display controller, and the high input impedance reduces disturbance to the measured source. The integrating conversion method is well suited to relatively slow process variables that favor repeatable readings over high sampling rates. A production design should add appropriate electrical isolation or protection as required, verify common-mode limits at the input, and use the hold function only after confirming that the surrounding control system does not need a faster update.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für ICL7116CQH+D – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | ICL7106CQH+TD | ICL7117CQH | ICL7137CQH | ICL7107CQH | ICL7116CQH |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | PLCC-44 (16.59 x 16.59 mm) | PLCC-44 | PLCC-44 | PLCC-44 | PLCC-44 | PLCC-44 |
| Conversion Architecture | Dual-slope integrating ADC | Dual-slope integrating ADC | Dual-slope integrating ADC | Integrating ADC | Dual-slope integrating ADC | Dual-slope integrating ADC |
| Display Resolution | 3.5 digits | 3.5 digits | 3.5 digits | 16 bit | 3.5 digits | 3.5 digits |
Wichtigste Unterscheidungsmerkmale
- Direct LCD drive combined with a hold input (vs. ICL7106CQH+TD)
- Display technology matched to LCD instruments (vs. ICL7117CQH)
- Higher-resolution alternative available for different measurement needs (vs. ICL7137CQH)
Designhinweise
Create the PCB footprint from the official PLCC-44 package drawing rather than scaling the 16.59 mm square body dimension generically. J-bend lead geometry, pad length, pad width, and solder-mask clearance must match the manufacturer drawing. Keep the footprint on a stable ground reference and avoid long exposed copper beneath the device if assembly or rework constraints apply. Because the catalog package-diagram library has no PLCC-44 key, do not use a generic QFN or LQFP drawing as a substitute.
The ICL7116CQH+D is rated for a 9 V supply and dissipates power when its internal circuitry operates across the supply-to-reference voltage difference. Place the bypass capacitor and reference components close to their associated pins, maintain a low-impedance ground return, and verify decoupling values against the manufacturer's typical application circuit. Estimated thermal dissipation is (VIN − VREF) × IC; for example, a 9 V supply and 5 V reference with 10 mA device current gives an estimated 40 mW, but the actual value depends on the operating state and internal circuitry.
Protect the analog input from electrostatic discharge, switching transients, and unintended overvoltage. Keep high-impedance input and reference routes short, physically separated from display and oscillator nets, and avoid routing them beneath noisy sources. The dual-slope integrating architecture averages input-related noise over its conversion interval, but the result still depends on correct oscillator timing, reference stability, and input filtering. Validate these conditions with the actual sensor and display wiring rather than relying only on converter specifications.
Do not select ICL7106CQH+TD, ICL7117CQH, or ICL7137CQH merely because all use PLCC-44 packages. ICL7106 lacks hold, ICL7117 drives LEDs rather than an LCD, and ICL7137 uses a different 16-bit family format. Before substitution, compare every pin, display segment mapping, supply arrangement, reference behavior, oscillator network, acquisition timing, and enable or hold signal. A same-package footprint is only the first step in establishing drop-in compatibility.
Compliance-Informationen
RoHS compliance is identified in the component listing. No additional reach, lead-free, halogen-free, conflict-minerals, or automotive qualification claim is established.