Analog Devices

ICL7116CQH+D - 3.5-Digit LCD ADC | Analog Devices

MPN: ICL7116CQH+D ✓ Hoạt động
9 V Vdss PLCC-44, 16.59 mm × 16.59 mm Package
MOQ: 1 |

ICL7116CQH+D Tóm tắt

Analog Devices ICL7116CQH+D is a 3.5-digit monolithic integrating analog-to-digital converter with direct LCD display drive, a 9 V supply rating, and a 44-pin PLCC package measuring approximately 16.59 mm by 16.59 mm. The converter uses a dual-slope conversion architecture and provides a hold input that can freeze the current reading for stable display or downstream processing.

An integrating analog-to-digital converter converts an analog input into a digital measurement by integrating the input over a defined interval and measuring the resulting time or counter value. The ICL7116 belongs to the ADC and DAC category of display-oriented mixed-signal semiconductors. It combines a high-input-impedance measurement front end with display decoding, segment drivers, a voltage reference, and clock circuitry in one monolithic device.

The ICL7116CQH+D provides a 3.5-digit measurement range with approximately 0.0015% maximum linearity error. It directly drives LCD displays rather than LED displays, eliminating a separate external display-driver stage in suitable meter designs. Its hold function distinguishes it from the related ICL7106 and adds useful control when a measurement must remain displayed or captured during a subsequent system action.

The device uses a dual-slope conversion method and includes onboard active components for polarity and digit drive, segment decoding, voltage reference, and clock operation. Its high input impedance is suited to sensors and measurement networks that cannot tolerate heavy loading. Because conversion speed depends on the selected integration cycle and oscillator arrangement, the application should use the timing and component-selection guidance in the manufacturer datasheet rather than treating the converter as a high-speed successive-approximation ADC.

Typical uses include handheld meters, laboratory instruments, panel meters, temperature displays, laboratory equipment, and industrial measurement panels. The direct LCD output and integrated conversion functions simplify a complete measurement instrument, while the hold input supports user-controlled sampling and display retention.

A successful design must provide the external reference, oscillator, input, display, and decoupling components required by the selected circuit topology. The PLCC package also requires careful PCB footprint alignment and adequate thermal dissipation because the converter can dissipate power as the supply-to-reference difference increases.

This page combines device specifications, package details, application guidance, replacement considerations, and a practical comparison of compatible family members. It is designed to help engineers evaluate the ICL7116CQH+D for a new panel-meter design or determine whether a related Maxim integrated converter can satisfy the required LCD, hold, package, and supply constraints.

Bộ thay thế dễ dàng lắp đặt cho ICL7116CQH+D — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.

Các biến thể trong loạt này

Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với ICL7116CQH+D (cùng hình factor và footprint) — khác nhau ở Display Output, RoHS Status, Package, Supply Voltage, Temperature Grade.

Maxim Integrated
Display Output: Direct LED display drive
Package: PLCC-44 (QCCJ)
Supply Voltage: 6 V to 9 V
So sánh với ICL7116CQH+D →
Maxim Integrated
Display Output: Direct LCD driver
RoHS Status: RoHS compliant
So sánh với ICL7116CQH+D →

ICL7106CQH+TD

✅ Drop-In
📦 PLCC-44 (16.59 x 16.59 mm)
No hold input, unlike ICL7116CQH+D; otherwise compared as a 3.5-digit direct-LCD integrating ADC in PLCC-44

📋 Tham chiếu thay thế (không có trong danh mục)

ICL7117CQH

✅ Drop-In ⚠️ Thông số chưa được xác minh
Maxim Integrated
📦 PLCC-44 (16.59 x 16.59 mm)
Dual-slope integrating ADC · 3.5 digits · 16 bit · 1 channel · Parallel word access · Bipolar input · Built-in reference source · Low-noise front end

Liên hệ để biết giá

Xem tài liệu →

ICL7137CQH

✅ Drop-In
Maxim Integrated
📦 PLCC-44 (16.59 x 16.59 mm)
Dual-slope analog-to-digital converter · 3.5 digits · Low-power device · Direct LCD driver · QFP, 10 mm x 10 mm x 2 mm · MS-022AB · QCCJ · 44 terminals

Liên hệ để biết giá

Xem tài liệu →

ICL7107CQH

✅ Drop-In ⚠️ Thông số chưa được xác minh
📦 PLCC-44 (16.59 x 16.59 mm)
Direct LED drive instead of direct LCD drive and no ICL7116 hold function, changing both display output and sampling control

📋 Tham chiếu thay thế (không có trong danh mục)

ICL7116CQH

✅ Drop-In
📦 PLCC-44 (16.59 x 16.59 mm)
Commercial-grade ICL7116 ordering code without the +D suffix; the listed core rating and 44-pin PLCC format remain the same

📋 Tham chiếu thay thế (không có trong danh mục)

ICL7116CQH+D Tỷ lệ tối đa & tính chất điện

ADC Architecture Dual-slope integrating ADC
Display Resolution 3.5 digits
Numeric Resolution 16 bit
Maximum Linearity Error 0.0015%
Điện áp cung cấp 9 V
Display Output Direct LCD drive
Hold Function Yes
Input Impedance Very high input impedance
Temperature Grade Commercial
Minimum Operating Temperature 0 °C
Maximum Operating Temperature 70 °C
Hộp PLCC-44, 16.59 mm × 16.59 mm
Package Code QCCJ
Terminal Count 44 terminals
Terminal Form J-bend
Package Shape Square
Kiểu lắp đặt Surface mount
Trạng thái RoHS Compliant

Hướng dẫn cấu hình chân ICL7116CQH+D square

Cấu hình chân cho ICL7116CQH+D (square gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.

Bảng cấu hình chân square cho ICL7116CQH+D

Không có dữ liệu chân cụ thể sẵn có cho ICL7116CQH+D.

Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.

Ứng dụng tiêu biểu

ICL7116CQH+D phù hợp cho 6 Áp dụngs: Digital Panel Meter, Laboratory Voltage Measurement, Industrial Temperature Display, Handheld Measurement Instrument, Weight Scale Indicator, Process Monitoring Readout.

📺

Digital Panel Meter

The ICL7116CQH+D fits a digital panel meter because it combines a 3.5-digit dual-slope integrating ADC with direct LCD drive in one 44-pin PLCC device. The converter can measure a conditioned analog input and present the result without a separate display-driver IC, reducing system complexity. The approximately 0.0015% maximum linearity error is relevant to the converter itself, while the complete meter accuracy also depends on the input network, reference, timing components, calibration, and display quality. The hold input is useful when the reading must remain stable while another function is selected or recorded.

🔧

Laboratory Voltage Measurement

The ICL7116CQH+D can form the measurement core of a laboratory voltage instrument when the input is conditioned to the converter's allowable range. Its 3.5-digit dual-slope format suits stable, readable instrument readings, while very high input impedance helps reduce loading on the source. The 9 V supply rating and direct LCD output simplify a dedicated meter architecture. For accuracy-critical work, engineers should account for reference tolerance, analog front-end offset and noise, integration timing, and calibration rather than attributing all measurement performance to the converter's 0.0015% maximum linearity specification.

🏭

Industrial Temperature Display

The ICL7116CQH+D is appropriate for an industrial temperature display when a resistive sensor can be connected through a suitable bridge and signal-conditioning circuit. The high-input-impedance integrating front end helps avoid excessive sensor loading, and the integrated LCD drive provides a straightforward display path. The 0 °C to 70 °C commercial-temperature specification suits controlled indoor equipment but not unconditioned industrial environments. A robust design should include input protection, reference compensation, sensor lead-error compensation where needed, and recalibration intervals based on the complete measurement chain.

📱

Handheld Measurement Instrument

The ICL7116CQH+D suits handheld meters that prioritize readable numerical output over rapid successive-approximation conversion. Its integrated LCD drive and 3.5-digit dual-slope conversion support a compact meter architecture, while the hold pin allows the displayed value to be frozen during range or mode changes. The commercial-temperature range covers many indoor handheld products. Designers should evaluate display contrast under changing ambient light, input protection, reference startup behavior, power-consumption requirements, and the PCB area required by the PLCC-44 footprint before finalizing the enclosure and user interface.

🏭

Weight Scale Indicator

The ICL7116CQH+D can support a weight-scale indicator when the load-cell signal is conditioned and scaled into the ADC input range. The 3.5-digit format is appropriate for compact commercial scales, and direct LCD drive simplifies the display subsystem. The hold function is useful during tare capture or when a measured value must remain visible. Real designs must account for excitation stability, mechanical vibration, temperature drift, bridge excitation noise, decimal-point placement, and calibration. Because the converter uses an integrating cycle, the update rate should be selected to balance readability against vibration rejection and measurement latency.

🖥️

Process Monitoring Readout

The ICL7116CQH+D can provide a local process-monitoring readout when a sensor or control-loop signal requires stable, human-readable measurement. Its direct LCD output avoids adding a separate display controller, and the high input impedance reduces disturbance to the measured source. The integrating conversion method is well suited to relatively slow process variables that favor repeatable readings over high sampling rates. A production design should add appropriate electrical isolation or protection as required, verify common-mode limits at the input, and use the hold function only after confirming that the surrounding control system does not need a faster update.

Tóm tắt các sản phẩm được đề xuất

ICL7106CQH+TD Related 3.5-digit direct-LCD integrating converter without hold Được sử dụng trong: Digital Panel Meter, Industrial Temperature Display, Weight Scale Indicator ICL7116CQH Same ICL7116 device family with a different ordering suffix Được sử dụng trong: Digital Panel Meter, Laboratory Voltage Measurement, Handheld Measurement Instrument, Process Monitoring Readout ICL7137CQH Maxim Integrated Được sử dụng trong: Laboratory Voltage Measurement, Weight Scale Indicator ICL7117CQH Maxim Integrated Được sử dụng trong: Industrial Temperature Display, Handheld Measurement Instrument ICL7107CQH Related integrating converter for LED process readouts Được sử dụng trong: Process Monitoring Readout
What is the ICL7116CQH+D and what does it do?
The ICL7116CQH+D is a 3.5-digit monolithic dual-slope integrating ADC that directly drives an LCD. According to the Analog Devices product page, the ICL7116 includes a hold pin, has very high input impedance, and integrates the analog-to-digital converter, display decoding, segment drive, voltage reference, and clock functions into one device. The +D ordering code identifies the listed commercial-grade 44-pin PLCC configuration.
What is the operating voltage of ICL7116CQH+D?
The ICL7116CQH+D has a 9 V supply rating. According to the Analog Devices product information and distributor listings, it is a commercial-temperature component specified for operation from 0 °C to 70 °C. The external circuit must also respect the input, reference, display, and common-mode limits established in the manufacturer datasheet rather than treating the 9 V supply rating as permission to exceed other device ratings.
Does the ICL7116CQH+D drive LCD or LED displays?
The ICL7116CQH+D directly drives an LCD display; the related ICL7117 is the LED-display version. According to the Analog Devices product page, both are 3.5-digit monolithic integrating analog-to-digital converters with a hold function and high input impedance. The distinction is important during PCB planning because an LCD output and an LED output are not interchangeable display interfaces.
What is the difference between ICL7116CQH+D and ICL7106CQH+TD?
The ICL7116CQH+D adds a hold input to the integrating ADC architecture used by the ICL7106 family. According to Analog Devices, ICL7116 and ICL7106 both drive LCDs, while the hold input lets the ICL7116 freeze the current reading. Both listed devices are 44-pin PLCC devices, but hold-pin behavior and power-supply details must be checked in the manufacturer datasheets before treating the comparison as an unconditional board-level substitution.
When should I choose ICL7116CQH+D instead of ICL7117CQH?
Choose the ICL7116CQH+D when the instrument uses a directly driven LCD and needs a hold input to freeze a measurement. Choose the ICL7117CQH when the same integrating-converter measurement approach is needed with direct LED display drive. According to the Analog Devices product page, the principal functional distinction between the ICL7116 and ICL7117 is LCD versus LED output, not the 3.5-digit conversion format.
What is the best drop-in replacement for ICL7116CQH+D?
No unrelated replacement should be selected solely because it also has 44 pins. The closest documented alternatives are ICL7106CQH+TD and ICL7137CQH, but the ICL7106 lacks the ICL7116 hold function while the ICL7137 is a different 16-bit family member. According to the manufacturer family information, a valid drop-in decision requires matching the PLCC-44 footprint, LCD drive, supply, timing, and hold function; use the Request a Quote form for an engineering-reviewed sourcing option.
Can ICL7137CQH replace ICL7116CQH+D?
The ICL7137CQH should not be assumed to be a direct replacement without a complete pin and timing review. The comparison data identifies both devices as 44-pin PLCC converters, but the ICL7137 is a 16-bit family member while the ICL7116 is a 3.5-digit display-oriented integrating ADC. According to the Analog Devices family information, the hold function and direct LCD architecture of the ICL7116 also require verification before replacement.
Where can I download the ICL7116CQH+D datasheet PDF?
The official ICL7116 product page is the appropriate starting point for the ICL7116CQH+D datasheet and supporting documentation. It identifies the ICL7116 as a 3.5-digit monolithic integrating ADC with direct LCD drive and a hold input. Use the manufacturer page linked from this listing for the authoritative electrical characteristics, pin descriptions, application circuit, and package information.
Where can I find the ICL7116CQH+D pinout and package drawing?
The ICL7116CQH+D pinout and package drawing should be taken from the manufacturer datasheet and package information for the 44-pin PLCC, package code QCCJ. The verified package dimensions are approximately 16.59 mm by 16.59 mm with J-bend terminals. Because the catalog diagram library has no dedicated PLCC-44 drawing, consult the manufacturer drawing directly before assigning tracks or creating the PCB footprint.
How accurate is the ICL7116CQH+D measurement system?
The ICL7116CQH+D is specified as a 3.5-digit converter with approximately 0.0015% maximum linearity error. That figure describes the converter component rather than the complete accuracy of every external analog front end. System-level error can also include reference accuracy, input-network errors, display readability, grounding, and the timing network, so production calibration and component tolerances must be evaluated as part of the measurement design.
What key specifications should engineers know about ICL7116CQH+D?
The key ICL7116CQH+D specifications are a 3.5-digit dual-slope integrating ADC, direct LCD drive, a hold input, 9 V supply rating, high input impedance, 0.0015% maximum linearity error, and a 44-pin PLCC package. According to the Analog Devices product information, the device also integrates display decoding, segment drivers, a voltage reference, and clock circuitry, reducing the external circuitry required for a display-oriented measurement instrument.
What can replace the ICL7116CQH+D in an LCD meter?
The closest starting point is the ICL7106CQH+TD because it is also identified as a 44-pin PLCC display converter, but it does not provide the ICL7116 hold function. The ICL7117CQH also offers a hold function but drives LEDs rather than an LCD. According to the Analog Devices family comparison, a replacement should preserve the direct LCD interface, conversion characteristics, timing, supply arrangement, and PCB footprint.
Is the ICL7116CQH+D suitable for panel meters and portable instruments?
The ICL7116CQH+D is suitable for LCD panel meters and portable measuring instruments because it combines conversion and direct display drive in one 3.5-digit device. Its high input impedance reduces loading on suitable sensor networks, and the hold input supports controlled display retention. The 0 °C to 70 °C commercial-temperature range makes it appropriate for indoor commercial equipment rather than unqualified automotive or extended-temperature use.
Where can I buy ICL7116CQH+D and check its lead time?
Use the Request a Quote form on this page to ask about ICL7116CQH+D price, stock, minimum order quantity, and current lead time. The ICL7116CQH+D is listed in commercial channels as a 44-pin PLCC display converter, but live inventory and allocation can change by package and quantity. Submit the required quantity, target date, and ship-to region to obtain a current sourcing response.
Is ICL7116CQH+D in stock and how much does it cost?
Current stock, allocation, and a binding quote for ICL7116CQH+D should be requested through the Request a Quote form on this page. The device is listed in distributor and component-search catalogs as a 3.5-digit LCD ADC in a 44-pin PLCC package. Because availability and commercial terms depend on quantity, package configuration, and date, use the form rather than relying on a static listing or historical price.
Is ICL7116CQH+D RoHS compliant, and what is its operating temperature?
The ICL7116CQH+D is identified as RoHS compliant and is a commercial-temperature component rated for 0 °C to 70 °C. According to the product listing, its 44-pin PLCC package uses package code QCCJ and approximately 16.59 mm by 16.59 mm dimensions. RoHS compliance addresses restricted substances in the component; it does not by itself establish suitability for automotive, medical, or extended-temperature requirements.

Dữ liệu tham khảo kỹ thuật cho ICL7116CQH+D — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.

Hướng dẫn chọn lựa

Choose the ICL7116CQH+D for a 3.5-digit LCD instrument that needs direct display drive, high input impedance, and a hold input for freezing a measurement. Its 9 V supply and commercial-temperature range suit controlled indoor equipment, and the PLCC-44 package simplifies reuse of an existing 44-pin display-converter layout. Select ICL7106CQH+TD only when hold capability is unnecessary and its 5 V operating arrangement is preferred. Select ICL7117CQH for a related design that uses LED rather than LCD output, or ICL7107CQH when an LED-display integrating converter without hold is sufficient. Consider ICL7137CQH when 16-bit measurement resolution is more important than a 3.5-digit display format. For every alternative, verify pin assignment, display segment mapping, oscillator components, reference voltage, timing, and PCB footprint against the manufacturer datasheets before approving a drop-in replacement.

So sánh với các sản phẩm thay thế

Tham số Sản phẩm này ICL7106CQH+TD ICL7117CQH ICL7137CQH ICL7107CQH ICL7116CQH
Brand Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices
Package PLCC-44 (16.59 x 16.59 mm) PLCC-44 PLCC-44 PLCC-44 PLCC-44 PLCC-44
Conversion Architecture Dual-slope integrating ADC Dual-slope integrating ADC Dual-slope integrating ADC Integrating ADC Dual-slope integrating ADC Dual-slope integrating ADC
Display Resolution 3.5 digits 3.5 digits 3.5 digits 16 bit 3.5 digits 3.5 digits

Bảo phân biệt quan trọng

  • Direct LCD drive combined with a hold input (vsICL7106CQH+TD)
  • Display technology matched to LCD instruments (vsICL7117CQH)
  • Higher-resolution alternative available for different measurement needs (vsICL7137CQH)

Ghi chú thiết kế

Create the PCB footprint from the official PLCC-44 package drawing rather than scaling the 16.59 mm square body dimension generically. J-bend lead geometry, pad length, pad width, and solder-mask clearance must match the manufacturer drawing. Keep the footprint on a stable ground reference and avoid long exposed copper beneath the device if assembly or rework constraints apply. Because the catalog package-diagram library has no PLCC-44 key, do not use a generic QFN or LQFP drawing as a substitute.

The ICL7116CQH+D is rated for a 9 V supply and dissipates power when its internal circuitry operates across the supply-to-reference voltage difference. Place the bypass capacitor and reference components close to their associated pins, maintain a low-impedance ground return, and verify decoupling values against the manufacturer's typical application circuit. Estimated thermal dissipation is (VIN − VREF) × IC; for example, a 9 V supply and 5 V reference with 10 mA device current gives an estimated 40 mW, but the actual value depends on the operating state and internal circuitry.

Protect the analog input from electrostatic discharge, switching transients, and unintended overvoltage. Keep high-impedance input and reference routes short, physically separated from display and oscillator nets, and avoid routing them beneath noisy sources. The dual-slope integrating architecture averages input-related noise over its conversion interval, but the result still depends on correct oscillator timing, reference stability, and input filtering. Validate these conditions with the actual sensor and display wiring rather than relying only on converter specifications.

Do not select ICL7106CQH+TD, ICL7117CQH, or ICL7137CQH merely because all use PLCC-44 packages. ICL7106 lacks hold, ICL7117 drives LEDs rather than an LCD, and ICL7137 uses a different 16-bit family format. Before substitution, compare every pin, display segment mapping, supply arrangement, reference behavior, oscillator network, acquisition timing, and enable or hold signal. A same-package footprint is only the first step in establishing drop-in compatibility.

Thông tin tuân thủ

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
Không chì
Unknown
Không halogen
Unknown
Khoáng vật xung đột
Unknown

RoHS compliance is identified in the component listing. No additional reach, lead-free, halogen-free, conflict-minerals, or automotive qualification claim is established.

Dữ liệu được xác minh vào: 2026-11-20 — dữ liệu được xác minh và quản lý bởi đội ngũ kỹ thuật phần cứng của XAIPART

Tìm kiếm liên quan

ICL7116CQH+D datasheet ICL7116CQH+D pinout ICL7116CQH+D PLCC-44 ICL7116CQH+D specifications ICL7116CQH+D price ICL7116CQH+D stock Analog Devices ICL7116CQH+D ICL7116CQH+D equivalent ICL7116CQH+D replacement ICL7116CQH+D vs ICL7106CQH+TD ICL7116CQH+D vs ICL7117CQH ICL7116CQH+D application circuit ICL7116 3.5 digit LCD ADC ICL7116 hold pin function

Các bộ phận và thuật ngữ liên quan

Analog Devices Maxim Integrated ICL7116CQH+D ICL7106CQH+TD ICL7117CQH ICL7137CQH ICL7107CQH ICL7116CQH analog-to-digital converter ADC integrating ADC dual-slope ADC display driver LCD display LED display 3.5-digit converter 16-bit ADC high input impedance direct LCD drive hold input voltage reference PLCC-44 QCCJ surface mount RoHS
Báo giá nhanh RFQ
Hãy điền đầy đủ thông tin — đội ngũ bán hàng của chúng tôi sẽ phản hồi trong vòng 24 giờ
Mã sản phẩm Nhà sản xuất Kiểu đóng gói QTY Giá mục tiêu Phụ
✓
Báo giá đã gửi!

Chúng tôi sẽ trả lời email của bạn trong vòng 24 giờ

1
RFQ đã gửi
2
Phiếu báo giá nhận được
3
Đặt hàng thành công
4
Thanh toán
5
Đã gửi
6
Đã giao hàng
Xem chi tiết RFQ