INA322EA/250 - Micropower Rail-to-Rail INA | Texas Instruments
Teilenummer: INA322EA/250 ✓ AktivINA322EA/250 Übersicht
An instrumentation amplifier is a precision analog signal-conditioning amplifier optimized for measuring small differential voltages embedded in larger common-mode voltages. Unlike a general-purpose operational amplifier, an instrumentation amplifier commonly provides high input impedance, symmetrical differential inputs, accurate gain control, and strong common-mode rejection. The INA322 belongs to the instrumentation-amplifier hierarchy within analog ICs, signal-chain conditioning, and sensor-interface applications.
Key characteristics include a 40 µA per-channel quiescent current, approximately 1 µA shutdown current, a 2 ppm/°C gain drift specification, and a 10 pA bias current. External gain resistors make the closed-loop gain selectable rather than fixed. The rail-to-rail output can approach the positive supply rail closely, making the device useful in low-voltage systems where amplified sensor output must use much of the available signal range.
The INA322 architecture uses an instrumentation-amplifier input stage to preserve common-mode rejection while amplifying the differential sensor signal. Its specified offset performance supports precision measurement of low-level signals, while the micropower bias allows continuous operation from constrained supplies. A closed-loop gain of 25 V/V appears in the manufacturer-part data, and operating temperature coverage extends from -55 °C to 125 °C for the identified ordering option.
Typical uses include bridge and strain-gauge conditioning, pressure and load-cell front ends, biomedical instrumentation, industrial sensor acquisition, and battery-powered measurement systems. The low 40 µA per-channel current is particularly useful when several measurement channels must operate from a compact power budget. The 10 pA bias current helps minimize loading on high-impedance sensors.
Design attention should center on gain-resistor selection, supply bypassing, input common-mode range, and output-signal headroom. Place the differential input connections away from switching nodes and noisy return currents. Use the manufacturer’s recommended capacitor and layout guidance, and verify that the input and output operating regions remain valid across the intended supply and temperature range.
This page consolidates the manufacturer’s device description, package information, ordering details, electrical characteristics, comparison guidance, and practical design notes into one engineering reference for INA322EA/250 evaluation and PCB planning.
Drop-in-Alternativen für INA322EA/250 – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit INA322EA/250 (gleiche Bauform und Footprint).
INA322EA/2K5
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →INA322EA/250G4
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
INA322EA/250 Grenzwerte & elektrische Eigenschaften
| Amplifier Type | 1-circuit instrumentation amplifier |
| Supply Type | Single-supply or bipolar supply |
| Quiescent Current per Channel | 40 µA |
| Abschaltstrom | 1 µA |
| Typical Input Offset Voltage | 2 mV |
| Maximum Input Offset Voltage | 10 mV at 5 V supply and VS/2 common-mode voltage |
| Input Bias Current | 10 pA |
| Gain Drift | 2 ppm/°C |
| Gain Configuration | External resistors |
| Closed-Loop Gain | 25 V/V |
| Output Swing | Approximately 0.02 V from the positive supply rail |
| Common-Mode Rejection | 60 dB |
| Versorgungsspannung | 5 V |
| Betriebstemperatur | -55 °C to 125 °C |
| Gehäuse | 8-pin VSSOP (DGK) |
| Montageart | Surface mount |
| Ausgangstyp | Rail-to-rail |
| Tape-and-Reel Quantity | 250 units |
INA322EA/250 8-pin vssop (dgk) Pinbelegungsleitfaden
Pinbelegung für INA322EA/250 (8-pin vssop (dgk)-Gehäuse). Dieses analoge Bauteil verfügt über Eingangs-, Ausgangs- und Versorgungspins. Offset-Null-, Kompensations- und Enable-Pin-Konfigurationen entnehmen Sie dem Herstellerdatenblatt. Ideal für Signalaufbereitung und Verstärkerschaltungen.
Keine detaillierten Pinbelegungsdaten verfügbar für INA322EA/250.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
INA322EA/250 ist geeignet für 6 Anwendungs: Strain-Gauge Bridge Conditioning, Battery-Powered Sensor Acquisition, Pressure and Load-Cell Measurement, Biomedical Signal Conditioning, Industrial Process Monitoring, Portable Environmental Monitoring.
Strain-Gauge Bridge Conditioning
The INA322EA/250 is suitable for conditioning millivolt-level differential signals from resistive strain-gauge bridges while consuming only 40 µA per channel. Its 10 pA input bias current minimizes loading of the bridge output, and external gain resistors allow the amplifier gain to be selected for the bridge excitation and target resolution. The rail-to-rail output improves use of the available signal range in compact instrumentation. Designers should verify the input common-mode voltage at the bridge midpoint, keep excitation wiring away from the amplifier inputs, and follow the manufacturer layout guidance to avoid converting bridge imbalance into unwanted noise.
Empfohlen
Battery-Powered Sensor Acquisition
The INA322EA/250 fits battery-operated sensor nodes because its normal supply consumption is 40 µA per channel and shutdown current is approximately 1 µA. These values help preserve available energy when the measurement amplifier must remain active only during sampling or when the shutdown function can isolate it between measurements. Its 10 pA bias current is also useful with high-source-impedance sensors, reducing the disturbance caused by amplifier loading. The power budget must include sensor excitation and conversion electronics, while the final common-mode and output-swing checks must use the complete battery operating range rather than only the nominal voltage.
Empfohlen
Pressure and Load-Cell Measurement
The INA322EA/250 can amplify the small differential output generated by pressure and load-cell bridges without imposing substantial input loading. Its 2 mV typical input offset and 2 ppm/°C gain-drift specification provide useful baseline performance for bridge measurement, while the rail-to-rail output supports single-supply signal chains. Gain is established with external resistors, so resistor tolerance and temperature coefficient directly affect scale-factor accuracy. Place the bridge excitation and return paths symmetrically, maintain the signal pair’s common-mode voltage within the operating region, and evaluate zero-offset correction if accuracy requirements exceed the device’s worst-case offset contribution.
Empfohlen
Biomedical Signal Conditioning
The INA322EA/250 can serve as the differential input stage for low-level biomedical sensor signals when low power and high input impedance are important. Its 10 pA bias current reduces loading on high-impedance electrodes or resistive sensing elements, and the instrumentation-amplifier topology supports common-mode rejection of signals shared by both inputs. Biomedical designs must account for patient protection, leakage paths, electrode-offset recovery, and isolation requirements rather than relying on amplifier specifications alone. PCB insulation barriers, guard traces, contamination control, and the application’s safety requirements should be established by qualified medical-device engineering practices before implementation.
Empfohlen
Industrial Process Monitoring
The INA322EA/250 is appropriate for low-level industrial process sensors where differential measurement is needed alongside compact, low-power electronics. It can amplify sensor outputs while rejecting much of the common-mode voltage present on long field-wired lines. The 40 µA per-channel supply current supports distributed acquisition, and shutdown can reduce consumption during inactive intervals. For factory equipment, protect inputs against transients, keep the instrumentation amplifier away from motor and relay return currents, and use a grounded or isolated interface strategy according to the installation. Input filtering and protection components must be selected without compromising the sensor bandwidth or introducing excessive leakage.
Empfohlen
Portable Environmental Monitoring
The INA322EA/250 supports portable environmental monitoring systems that combine a low-power sensor, analog amplification, and digital conversion. Its micropower operating current preserves battery life, while the rail-to-rail output can maximize the usable range of a low-voltage ADC input. Differential inputs help reject common-mode variation when the sensor is connected through wiring that may pick up environmental interference. A practical design should select gain resistors appropriate for the sensor’s full-scale output, confirm that the common-mode voltage remains valid across temperature and supply tolerances, and use short, guarded input routing to minimize leakage and electromagnetic pickup.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für INA322EA/250 – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | INA322EA/2K5 | INA322EA/250G4 |
|---|---|---|---|
| Package | 8-pin VSSOP (DGK) | 8-pin VSSOP (DGK) | 8-pin VSSOP (DGK) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Product Type | Micropower CMOS instrumentation amplifier | Micropower single-supply CMOS instrumentation amplifier | Micropower single-supply CMOS instrumentation amplifier |
| Number of Circuits | 1 circuit | 1 circuit | 1 circuit |
| Quiescent Current per Channel | 40 µA | 40 µA | 40 µA |
| Shutdown Current | 1 µA | 1 µA | 1 µA |
| Input Bias Current | 10 pA | 10 pA | 10 pA |
| Gain Drift | 2 ppm/°C | 2 ppm/°C | 2 ppm/°C |
| Supply Configuration | Single-supply or bipolar operation | Single-supply or bipolar operation | Single-supply or bipolar operation |
| Output Type | Rail-to-rail | Rail-to-rail | Rail-to-rail |
| Special Features | Shutdown and externally selected gain | Shutdown and externally selected gain | Shutdown and externally selected gain |
Wichtigste Unterscheidungsmerkmale
- Very low operating current for a differential instrumentation amplifier (vs. INA322EA/2K5)
- Low input bias supports high-impedance sensing (vs. INA322EA/250G4)
- Single-supply flexibility with rail-to-rail output (vs. INA322EA/2K5)
Designhinweise
Route the differential input pair as a tightly coupled, symmetric pair and keep it away from switching nodes, relay contacts, and high-current return paths. Connect the external gain-resistor network close to the corresponding amplifier pins, and use the shortest practical ground return from the supply capacitor. Guarding and solid reference-plane techniques can be especially important when the source impedance is high and leakage or surface contamination could otherwise create a larger error than the amplifier offset.
Place the supply-bypass capacitor immediately adjacent to the device supply and ground pins, with its ground connection directed into the quiet ground region rather than through a noisy load-current path. Because the INA322EA/250 is intended for micropower operation, capacitor leakage, resistor leakage, and input protection-device leakage can become significant relative to the 10 pA bias-current specification. Select low-leakage components where the sensor source impedance is high.
Check the input common-mode voltage and output swing at the minimum and maximum supply voltages before selecting the gain. The rail-to-rail output does not eliminate all headroom requirements, and a sensor midpoint can exceed the valid input range during startup or fault conditions. Also include worst-case gain-resistor tolerance and temperature coefficient when calculating measurement scale error; these external components may contribute more uncertainty than the amplifier’s internal gain drift.
Compliance-Informationen
The manufacturer part-detail listing identifies a green plastic MSOP/VSSOP package, but no explicit RoHS, REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification statement was included. Compliance fields therefore remain unknown.