Texas Instruments

INA322EA/250 - Micropower Rail-to-Rail INA | Texas Instruments

MPN: INA322EA/250 ✓ فعال
Single-supply or bipolar supply Vdss 40 µA Id 8-pin VSSOP (DGK) Package
MOQ: 1 |

INA322EA/250 جائزہ

Texas Instruments INA322EA/250 is a micropower, single-supply CMOS instrumentation amplifier with 40 µA per channel of supply current, 2 mV typical input offset voltage, 10 pA input bias current, and rail-to-rail output operation in an 8-pin VSSOP (DGK) package. The /250 ordering option is supplied on a 250-unit tape-and-reel format. It accepts single-supply or bipolar-supply operation and uses external resistors to set the closed-loop gain.

An instrumentation amplifier is a precision analog signal-conditioning amplifier optimized for measuring small differential voltages embedded in larger common-mode voltages. Unlike a general-purpose operational amplifier, an instrumentation amplifier commonly provides high input impedance, symmetrical differential inputs, accurate gain control, and strong common-mode rejection. The INA322 belongs to the instrumentation-amplifier hierarchy within analog ICs, signal-chain conditioning, and sensor-interface applications.

Key characteristics include a 40 µA per-channel quiescent current, approximately 1 µA shutdown current, a 2 ppm/°C gain drift specification, and a 10 pA bias current. External gain resistors make the closed-loop gain selectable rather than fixed. The rail-to-rail output can approach the positive supply rail closely, making the device useful in low-voltage systems where amplified sensor output must use much of the available signal range.

The INA322 architecture uses an instrumentation-amplifier input stage to preserve common-mode rejection while amplifying the differential sensor signal. Its specified offset performance supports precision measurement of low-level signals, while the micropower bias allows continuous operation from constrained supplies. A closed-loop gain of 25 V/V appears in the manufacturer-part data, and operating temperature coverage extends from -55 °C to 125 °C for the identified ordering option.

Typical uses include bridge and strain-gauge conditioning, pressure and load-cell front ends, biomedical instrumentation, industrial sensor acquisition, and battery-powered measurement systems. The low 40 µA per-channel current is particularly useful when several measurement channels must operate from a compact power budget. The 10 pA bias current helps minimize loading on high-impedance sensors.

Design attention should center on gain-resistor selection, supply bypassing, input common-mode range, and output-signal headroom. Place the differential input connections away from switching nodes and noisy return currents. Use the manufacturer’s recommended capacitor and layout guidance, and verify that the input and output operating regions remain valid across the intended supply and temperature range.

This page consolidates the manufacturer’s device description, package information, ordering details, electrical characteristics, comparison guidance, and practical design notes into one engineering reference for INA322EA/250 evaluation and PCB planning.

کے لیے ڈراپ اِن متبادل INA322EA/250 — یکساں پیکیج، پن سے پن مطابقت پذیر۔ مختلف پیکیج والے پرزے جن کے لیے PCB دوبارہ کام درکار ہو، شامل نہیں ہیں۔

اس سیریز میں مختلف ورژن

اسی سیریز کے ماڈلز جو ڈراپ اِن مطابقت رکھتے ہیں INA322EA/250 (یکساں فارم فیکٹر اور فٹ پرنٹ).

Texas Instruments

INA322EA/2K5

✅ ڈراپ-اِن
Texas Instruments
📦 VSSOP-8 (DGK)
Single-circuit instrumentation amplifier · 25 V/V · 40 µA typical per channel · 1 µA · 2 mV · 10 pA · 60 dB minimum · 2 ppm/°C

قیمت کے لیے رابطہ کریں

ڈیٹا شیٹ دیکھیں →

INA322EA/250G4

✅ ڈراپ-اِن
📦 VSSOP-8 (DGK)
Same 8-pin VSSOP (DGK) footprint and identified INA322EA ordering family; the G4 suffix distinguishes the ordering representation.

📋 حوالہ جاتی متبادل (کیٹلاگ میں نہیں)

INA322EA/250 زیادہ سے زیادہ ریٹنگز اور برقی خصوصیات

Amplifier Type 1-circuit instrumentation amplifier
Supply Type Single-supply or bipolar supply
Quiescent Current per Channel 40 µA
شٹ ڈاؤن کرنٹ 1 µA
Typical Input Offset Voltage 2 mV
Maximum Input Offset Voltage 10 mV at 5 V supply and VS/2 common-mode voltage
Input Bias Current 10 pA
Gain Drift 2 ppm/°C
Gain Configuration External resistors
Closed-Loop Gain 25 V/V
Output Swing Approximately 0.02 V from the positive supply rail
Common-Mode Rejection 60 dB
سپلائی وولٹیج 5 V
آپریٹنگ درجہ حرارت -55 °C to 125 °C
پیکیج 8-pin VSSOP (DGK)
ماؤنٹنگ ٹائپ Surface mount
آؤٹ پٹ کی قسم Rail-to-rail
Tape-and-Reel Quantity 250 units

INA322EA/250 8-pin vssop (dgk) پن کنفیگریشن گائیڈ

INA322EA/250 (8-pin vssop (dgk) پیکیج) کے لیے پن کنفیگریشن۔ اس اینالاگ کمپوننٹ میں اِن پٹ، آؤٹ پٹ اور پاور سپلائی پنز شامل ہیں۔ آفسیٹ نل، کمپنسیشن اور اِن ایبل پن کنفیگریشنز کے لیے مینوفیکچرر کے ڈیٹا شیٹ سے رجوع کریں۔ سگنل کنڈیشننگ اور ایمپلیفائر سرکٹس کے لیے مثالی۔

INA322EA/250 کے لیے 8-pin vssop (dgk) پیکیج پن آؤٹ ڈایاگرام

کے لیے تفصیلی پن آؤٹ ڈیٹا دستیاب نہیں INA322EA/250.

رجوع کریں ڈیٹا شیٹ مکمل پن کنفیگریشن کے لیے۔

عام استعمالات

INA322EA/250 کے لیے موزوں ہے 6 ایپلیکیشنs: Strain-Gauge Bridge Conditioning, Battery-Powered Sensor Acquisition, Pressure and Load-Cell Measurement, Biomedical Signal Conditioning, Industrial Process Monitoring, Portable Environmental Monitoring.

🏭

Strain-Gauge Bridge Conditioning

The INA322EA/250 is suitable for conditioning millivolt-level differential signals from resistive strain-gauge bridges while consuming only 40 µA per channel. Its 10 pA input bias current minimizes loading of the bridge output, and external gain resistors allow the amplifier gain to be selected for the bridge excitation and target resolution. The rail-to-rail output improves use of the available signal range in compact instrumentation. Designers should verify the input common-mode voltage at the bridge midpoint, keep excitation wiring away from the amplifier inputs, and follow the manufacturer layout guidance to avoid converting bridge imbalance into unwanted noise.

🔋

Battery-Powered Sensor Acquisition

The INA322EA/250 fits battery-operated sensor nodes because its normal supply consumption is 40 µA per channel and shutdown current is approximately 1 µA. These values help preserve available energy when the measurement amplifier must remain active only during sampling or when the shutdown function can isolate it between measurements. Its 10 pA bias current is also useful with high-source-impedance sensors, reducing the disturbance caused by amplifier loading. The power budget must include sensor excitation and conversion electronics, while the final common-mode and output-swing checks must use the complete battery operating range rather than only the nominal voltage.

📊

Pressure and Load-Cell Measurement

The INA322EA/250 can amplify the small differential output generated by pressure and load-cell bridges without imposing substantial input loading. Its 2 mV typical input offset and 2 ppm/°C gain-drift specification provide useful baseline performance for bridge measurement, while the rail-to-rail output supports single-supply signal chains. Gain is established with external resistors, so resistor tolerance and temperature coefficient directly affect scale-factor accuracy. Place the bridge excitation and return paths symmetrically, maintain the signal pair’s common-mode voltage within the operating region, and evaluate zero-offset correction if accuracy requirements exceed the device’s worst-case offset contribution.

💊

Biomedical Signal Conditioning

The INA322EA/250 can serve as the differential input stage for low-level biomedical sensor signals when low power and high input impedance are important. Its 10 pA bias current reduces loading on high-impedance electrodes or resistive sensing elements, and the instrumentation-amplifier topology supports common-mode rejection of signals shared by both inputs. Biomedical designs must account for patient protection, leakage paths, electrode-offset recovery, and isolation requirements rather than relying on amplifier specifications alone. PCB insulation barriers, guard traces, contamination control, and the application’s safety requirements should be established by qualified medical-device engineering practices before implementation.

🏭

Industrial Process Monitoring

The INA322EA/250 is appropriate for low-level industrial process sensors where differential measurement is needed alongside compact, low-power electronics. It can amplify sensor outputs while rejecting much of the common-mode voltage present on long field-wired lines. The 40 µA per-channel supply current supports distributed acquisition, and shutdown can reduce consumption during inactive intervals. For factory equipment, protect inputs against transients, keep the instrumentation amplifier away from motor and relay return currents, and use a grounded or isolated interface strategy according to the installation. Input filtering and protection components must be selected without compromising the sensor bandwidth or introducing excessive leakage.

🧩

Portable Environmental Monitoring

The INA322EA/250 supports portable environmental monitoring systems that combine a low-power sensor, analog amplification, and digital conversion. Its micropower operating current preserves battery life, while the rail-to-rail output can maximize the usable range of a low-voltage ADC input. Differential inputs help reject common-mode variation when the sensor is connected through wiring that may pick up environmental interference. A practical design should select gain resistors appropriate for the sensor’s full-scale output, confirm that the common-mode voltage remains valid across temperature and supply tolerances, and use short, guarded input routing to minimize leakage and electromagnetic pickup.

What is the INA322EA/250?
The INA322EA/250 is a Texas Instruments micropower CMOS instrumentation amplifier in an 8-pin VSSOP package. It provides differential-signal conditioning with 40 µA per channel of quiescent current, 2 mV typical input offset voltage, 10 pA input bias current, and rail-to-rail output operation. The /250 option identifies a 250-unit tape-and-reel ordering format, according to the manufacturer product and part-detail listings.
What is the operating voltage of INA322EA/250?
The INA322EA/250 supports single-supply and bipolar-supply operation, with 5 V appearing in the published specification listing for this device. Because the family is specified for low-voltage instrumentation-amplifier systems, the designer should also verify the complete recommended operating range and absolute maximum ratings in the Texas Instruments INA322 datasheet before finalizing the power architecture.
How much current does the INA322EA/250 consume?
The INA322EA/250 consumes 40 µA per channel in its normal operating state and approximately 1 µA when shutdown is invoked. This micropower behavior makes it suitable for battery-operated instruments and remote sensor nodes. The Texas Instruments product page identifies the device specifically as a micropower instrumentation amplifier with shutdown support.
What is the input offset voltage of INA322EA/250?
The INA322EA/250 has a typical input offset voltage of 2 mV, while the INA322EA maximum input offset voltage is specified as 10 mV with a 5 V supply and common-mode voltage equal to VS/2. The manufacturer datasheet also provides power-supply-rejection and common-mode-rejection information for estimating worst-case offset in a specific application.
Where can I download the INA322EA/250 datasheet PDF?
The official Texas Instruments INA322 datasheet is available through the manufacturer’s GPN download link at https://www.ti.com/lit/gpn/INA322, and the product details are available at https://www.ti.com/product/INA322. The manufacturer document should be used for the complete electrical characteristics, pin descriptions, gain-resistor equations, typical characteristics, and application-circuit recommendations.
Where can I find the INA322EA/250 pinout?
The INA322EA/250 pinout is published in the pin-configuration section of the Texas Instruments INA322 datasheet. The device uses an 8-pin VSSOP (DGK) package, and its gain network, differential inputs, reference connection, supply pins, shutdown control, and output are identified there. Use the manufacturer drawing directly when assigning PCB nets and verifying exposed-pad requirements.
Can INA322EA/250 operate from a single supply?
Yes, the INA322EA/250 is designed for single-supply operation and also supports bipolar-supply configurations. Its rail-to-rail output allows the amplified result to use much of the available output range, although the exact usable input and output ranges depend on supply voltage and common-mode conditions. Verify those limits against the datasheet for the operating system.
What can replace the INA322EA/250?
The closest identified same-family option is the Texas Instruments INA322EA/2K5, which uses the same 8-pin VSSOP (DGK) package and supports the same instrumentation-amplifier architecture. The INA322EA/250G4 is another identified ordering representation. Before replacing the device, compare gain accuracy, offset, supply range, common-mode range, shutdown behavior, pin functions, and production ordering codes.
Is the INA322EA/250 the same as INA322EA/2K5?
No, the INA322EA/250 and INA322EA/2K5 are distinct ordering options within the Texas Instruments INA322EA family. Both are associated with the 8-pin VSSOP (DGK) instrumentation-amplifier package, but their ordering codes indicate different gain-related variants or qualification configurations. Consult the manufacturer ordering table before treating either device as an exact substitute.
INA322EA/250 vs INA326EA/2K5 - which is better for a precision bridge?
The INA322EA/250 emphasizes micropower operation at 40 µA per channel, while the INA326EA/2K5 is identified as a precision, low-drift CMOS instrumentation amplifier. The better choice depends on whether power consumption or precision and drift dominate the design. A drop-in substitution also requires matching the VSSOP footprint, pin functions, gain network, supply range, and common-mode limits.
When should I choose INA322EA/250 over a higher-precision instrumentation amplifier?
Choose the INA322EA/250 when low supply current is more important than class-leading precision. Its 40 µA per-channel consumption, 2 mV typical offset, 10 pA bias current, and 2 ppm/°C gain drift are useful for portable sensor interfaces and other low-power systems. Choose a higher-precision alternative when offset error, gain drift, or common-mode performance directly limits measurement accuracy.
Is INA322EA/250 suitable for high-impedance sensors?
The INA322EA/250 is suitable for many high-impedance sensor interfaces because its input bias current is 10 pA. That low loading helps preserve the signal produced by resistive bridges, strain gauges, and similar sensors. Signal-source impedance, input protection, leakage from the PCB, and the device’s input common-mode range must still be evaluated for the complete measurement chain.
Where can I buy INA322EA/250 online?
Use the Request a Quote form on this page to request INA322EA/250 availability, current commercial terms, and lead time. The manufacturer identifies INA322EA/250 as an 8-pin VSSOP device with a -55 °C to 125 °C operating-temperature range. The quote form allows the exact ordering code and required 250-unit reel quantity to be confirmed before an order is placed.
What is the price of INA322EA/250?
Current commercial pricing for INA322EA/250 is not stated on this page because transaction values can change with quantity, availability, and supply conditions. Use the Request a Quote form on this page for the exact MPN and required order quantity. The request should identify the Texas Instruments INA322EA/250 and its 250-unit tape-and-reel ordering format.
What is the lead time and stock status for INA322EA/250?
Current stock and lead time should be requested through the Request a Quote form on this page for the exact INA322EA/250 ordering code. The manufacturer listing identifies the part in an 8-pin VSSOP (DGK) package and the /250 suffix denotes the reel quantity. A purchase-order confirmation should establish current availability, factory lead time, and delivery terms.
What are the key specifications of INA322EA/250 that engineers should know?
The key INA322EA/250 specifications are 40 µA per-channel quiescent current, approximately 1 µA shutdown current, 2 mV typical input offset voltage, 10 pA input bias current, 2 ppm/°C gain drift, external-resistor gain setting, and rail-to-rail output operation. The device is offered in an 8-pin VSSOP (DGK) package with a -55 °C to 125 °C operating-temperature range.

کے لیے انجینئرنگ ریفرنس ڈیٹا INA322EA/250 — موازنہ، ڈیزائن رہنمائی، اور تعمیل کی معلومات۔

انتخاب کی گائیڈ

Choose the INA322EA/250 when the design needs a low-power, single-supply instrumentation amplifier for differential sensor signals and can meet its input common-mode, output-swing, and offset requirements. Its 40 µA per-channel current, approximately 1 µA shutdown current, and 10 pA bias current are particularly useful in portable, distributed, and high-impedance measurement systems. The INA322EA/2K5 is the closest identified same-family alternative with the same 8-pin VSSOP footprint, but its ordering and gain characteristics should be checked before substitution. The INA322EA/250G4 is another same-footprint ordering representation. If measurement accuracy is dominated by gain drift or offset and power consumption is not critical, a higher-precision instrumentation amplifier may be preferable, provided that pinout, package, gain network, and electrical limits are redesigned and validated.

متبادلات کے ساتھ موازنہ

پیرامیٹر یہ پروڈکٹ INA322EA/2K5 INA322EA/250G4
Package 8-pin VSSOP (DGK) 8-pin VSSOP (DGK) 8-pin VSSOP (DGK)
Brand Texas Instruments Texas Instruments Texas Instruments
Product Type Micropower CMOS instrumentation amplifier Micropower single-supply CMOS instrumentation amplifier Micropower single-supply CMOS instrumentation amplifier
Number of Circuits 1 circuit 1 circuit 1 circuit
Quiescent Current per Channel 40 µA 40 µA 40 µA
Shutdown Current 1 µA 1 µA 1 µA
Input Bias Current 10 pA 10 pA 10 pA
Gain Drift 2 ppm/°C 2 ppm/°C 2 ppm/°C
Supply Configuration Single-supply or bipolar operation Single-supply or bipolar operation Single-supply or bipolar operation
Output Type Rail-to-rail Rail-to-rail Rail-to-rail
Special Features Shutdown and externally selected gain Shutdown and externally selected gain Shutdown and externally selected gain

اہم امتیازی خصوصیات

  • Very low operating current for a differential instrumentation amplifier (بمقابلہINA322EA/2K5)
  • Low input bias supports high-impedance sensing (بمقابلہINA322EA/250G4)
  • Single-supply flexibility with rail-to-rail output (بمقابلہINA322EA/2K5)

ڈیزائن نوٹس

Route the differential input pair as a tightly coupled, symmetric pair and keep it away from switching nodes, relay contacts, and high-current return paths. Connect the external gain-resistor network close to the corresponding amplifier pins, and use the shortest practical ground return from the supply capacitor. Guarding and solid reference-plane techniques can be especially important when the source impedance is high and leakage or surface contamination could otherwise create a larger error than the amplifier offset.

Place the supply-bypass capacitor immediately adjacent to the device supply and ground pins, with its ground connection directed into the quiet ground region rather than through a noisy load-current path. Because the INA322EA/250 is intended for micropower operation, capacitor leakage, resistor leakage, and input protection-device leakage can become significant relative to the 10 pA bias-current specification. Select low-leakage components where the sensor source impedance is high.

Check the input common-mode voltage and output swing at the minimum and maximum supply voltages before selecting the gain. The rail-to-rail output does not eliminate all headroom requirements, and a sensor midpoint can exceed the valid input range during startup or fault conditions. Also include worst-case gain-resistor tolerance and temperature coefficient when calculating measurement scale error; these external components may contribute more uncertainty than the amplifier’s internal gain drift.

تعمیل کی معلومات

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
لیڈ فری
Unknown
ہیلوجن فری
Unknown
کنفلیکٹ منرلز
Unknown

The manufacturer part-detail listing identifies a green plastic MSOP/VSSOP package, but no explicit RoHS, REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification statement was included. Compliance fields therefore remain unknown.

ڈیٹا کی تصدیق کی تاریخ: 2026-11-23 — ڈیٹا XAIPART کی کمپوننٹ انجینئرنگ ٹیم کے ذریعے تصدیق شدہ اور ترتیب شدہ

متعلقہ تلاشیں

INA322EA/250 datasheet INA322EA/250 pinout INA322EA/250 datasheet pdf INA322EA/250 application circuit INA322EA/250 schematic INA322EA/250 equivalent INA322EA/250 replacement INA322EA/250 cross reference INA322EA/250 vs INA326EA/2K5 INA322EA/250 footprint INA322EA/250 price INA322EA/250 stock Texas Instruments INA322EA/250 INA322EA/250 VSSOP-8 pinout INA322EA/250 micropower instrumentation amplifier

متعلقہ اجزاء اور اصطلاحات

Texas Instruments INA322EA/250 INA322EA/2K5 INA322EA/250G4 INA326EA/2K5 instrumentation amplifier precision analog signal conditioner differential amplifier analog IC semiconductor micropower CMOS single-supply operation bipolar-supply operation rail-to-rail output input offset voltage input bias current gain drift common-mode rejection shutdown current external gain resistor VSSOP-8 DGK package surface mount strain-gauge bridge battery-powered sensor acquisition
فوری کوٹ RFQ
مکمل تفصیلات بھریں — ہماری سیلز ٹیم 24 گھنٹوں میں جواب دے گی
پارٹ نمبر مینوفیکچرر پیکج QTY ہدف قیمت کل رقم
✓
کوٹ جمع ہو گیا!

ہم 24 گھنٹوں کے اندر آپ کے ای میل کا جواب دیں گے

1
RFQ جمع ہو گیا
2
کوٹ موصول ہو گیا
3
آرڈر دے دیا گیا
4
ادائیگی
5
بھیج دیا گیا
6
ڈیلیور شدہ
RFQ تفصیلات دیکھیں