ISL8487IBZ - 5V RS-485/RS-422 Transceiver | Renesas
Teilenummer: ISL8487IBZ ✓ AktivISL8487IBZ Übersicht
An RS-485/RS-422 transceiver is an interface IC that converts logic-level signals into differential voltage waveforms for reliable communication over balanced copper cables. The transmitter drives a differential output, while the receiver converts the differential input into a logic-level signal. By placing a common-mode voltage range and differential signaling between two conductors, this interface class supports improved noise immunity compared with single-ended communication. The ISL8487 family therefore sits between a host controller and a physical network such as Modbus RTU, PROFIBUS-related equipment, or proprietary industrial buses.
The ISL8487IBZ operates from a 5 V supply and is designed for low-power, high-speed or slew-rate-limited communication. Its fractional 1/8 unit-load characteristic allows more receiving nodes on a multidrop bus than a conventional one-unit-load transceiver. Because the package contains one transmitter and one receiver, it can support half-duplex communication when the driver and receiver controls are managed by the host. The device also includes ESD protection, an important feature for transceiver devices connected to external cables and field-accessible equipment.
The family is described as BiCMOS and is designed to meet RS-485 and RS-422 balanced-communication requirements. Its low-power operation suits distributed equipment where every milliampere can affect system thermal design. In half-duplex networks, the receiver may remain active while the driver is disabled, allowing the attached controller to detect responses or bus contention. Designers should still control the enable and disable timing to prevent the driver from fighting an external driver during bus turnaround.
Typical uses include industrial sensor gateways, PLC communication ports, building-control terminals, instrumentation, data-acquisition equipment, and factory automation nodes. The 8-SOIC package also supports compact peripheral boards where a larger multi-channel transceiver would be unnecessary. In a typical multidrop network, the ISL8487IBZ connects a UART or embedded controller to the balanced bus, while termination and biasing components are placed only where required by the network topology.
The main design consideration is cable-side protection. Although the device includes ESD protection, the maximum bus voltage, common-mode range, ground-reference limits, connector placement, and external surge-protection requirements must be checked against the application environment. Keep the balanced pair tightly coupled, connect the transceiver ground reference appropriately, and verify termination and fail-safe behavior for the selected operating mode. The 5 V supply should be decoupled close to the device, and unused control inputs must not float.
This page combines the component identity, RS-485/RS-422 interface characteristics, package information, replacement guidance, comparison details, and practical PCB-design considerations into a focused engineering reference. It also identifies the available same-package alternatives and distinguishes the verified role of each candidate for drop-in replacement decisions.
Drop-in-Alternativen für ISL8487IBZ – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
ISL8487EIBZ
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
MAX487ECSA+
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
ISL8487IBZ Technische Daten
| Product Type | Single RS-485/RS-422 transceiver |
| Versorgungsspannung | 5 V |
| Number of Drivers | 1 |
| Number of Receivers | 1 |
| Bus Standard | RS-485 and RS-422 |
| Unit Load | 1/8 unit load |
| Signaling | Differential balanced signaling |
| Communication Mode | Half-duplex |
| Process Technology | BiCMOS |
| ESD Protection | Yes |
| Gehäuse | 8-pin SOIC, 3.90 mm width |
| Package Type | Surface-mount SOIC |
| Pin-Anzahl | 8 pins |
ISL8487IBZ surface-mount soic Pinbelegungsleitfaden
Pinbelegung für ISL8487IBZ (surface-mount soic-Gehäuse). Pin-Nummerierung, Funktionen und Anschlussdiagramme sind im Herstellerdatenblatt definiert. Entnehmen Sie diesem den genauen Footprint und Lötrichtlinien.
Keine detaillierten Pinbelegungsdaten verfügbar für ISL8487IBZ.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
ISL8487IBZ ist geeignet für 6 Anwendungs: Industrial RS-485 Sensor Gateway, PLC and Factory-Control Communication Port, Building-Control and HVAC Terminal, Data-Acquisition Instrument, RS-422 Point-to-Point Link, Motorized Equipment and Remote Actuator.
Industrial RS-485 Sensor Gateway
The ISL8487IBZ fits an industrial sensor gateway by placing one differential transceiver between a host UART and a field bus. Its 5 V operation, one-driver and one-receiver arrangement, and 1/8 unit-load rating support a multidrop network with multiple receiving nodes. The controller can keep the receiver active for bus monitoring while asserting the driver only during transmission, reducing contention and avoiding a second physical interface. In a practical implementation, the balanced pair should be routed as a tightly coupled differential pair, with termination and fail-safe biasing fitted according to the network topology. The 8-SOIC format also keeps the interface compact enough for a densely populated gateway board while preserving separate driver and receiver control.
Empfohlen
PLC and Factory-Control Communication Port
The ISL8487IBZ is appropriate for a PLC communication port that must connect a controller to a balanced RS-485 bus. The 1/8 unit-load characteristic permits a bus containing more than two receiving nodes, while differential signaling improves immunity to industrial noise compared with a single-ended UART. A half-duplex arrangement reduces the number of interface channels required because the same IC contains both the transmitter and receiver. Firmware should enforce a defined turnaround interval so that local transmission ends before another node responds. Board layout should keep the cable-side connection near the transceiver, provide a stable ground reference, and use the manufacturer data to select termination, fail-safe biasing, and any external surge-protection components.
Empfohlen
Building-Control and HVAC Terminal
The ISL8487IBZ can connect a building-control terminal to an RS-485 backbone where low power and compact packaging are important. Its 5 V supply matches common embedded-control rails, and the single-driver, single-receiver arrangement supports half-duplex command and response traffic over one balanced pair. The fractional 1/8 unit load is particularly useful when the controller coordinates multiple indoor units, sensors, or powered field devices on one bus segment. For reliable operation, use the same pair for communication and non-twisted stubs only when permitted by the bus topology. Keep enable timing under firmware control, prevent floating inputs, and verify that the transceiver's operating limits match the building's temperature range and cable length.
Empfohlen
Data-Acquisition Instrument
The ISL8487IBZ is suitable for a data-acquisition instrument that must exchange commands or measurements over RS-485 or RS-422. The differential interface helps preserve data integrity when the instrument is connected to a long cable or shares an enclosure with switching converters and motors. One transceiver is sufficient for a half-duplex controller channel, and the 1/8 unit-load rating allows the instrument to participate in a multidrop measurement network. Place the IC near the input or output connector, maintain consistent spacing between the differential conductors, and provide a local ground reference without forcing large ground currents through the signal pair. External protection should be considered when the instrument port is accessible from the field or connected through external wiring.
Empfohlen
RS-422 Point-to-Point Link
The ISL8487IBZ supports a point-to-point RS-422 interface because its driver and receiver implement balanced differential signaling in a single 8-SOIC device. In a full-duplex RS-422 design, however, two physically independent communication paths are normally required, so a single ISL8487 channel can implement one direction or a half-duplex arrangement rather than both RS-422 directions by itself. The 5 V interface is compatible with many embedded UART systems, and the low-power family design helps limit system consumption. Confirm the receiver logic, driver timing, cable termination, and maximum data rate against the manufacturer datasheet. For a bidirectional RS-422 port, evaluate a second transceiver or a dual-channel interface according to the required topology.
Empfohlen
Motorized Equipment and Remote Actuator
The ISL8487IBZ can provide the command interface between a controller and a remote motorized actuator connected over an RS-485 field bus. The differential bus is useful in environments containing motor drives, relays, and switching supplies because it reduces susceptibility to common-mode noise. Its 1/8 unit-load rating supports several nodes on a shared segment, while the 5 V supply is convenient for embedded motor controllers. Driver-enable and receiver-enable signals should be sequenced so the device does not contend with another node during an emergency stop or status response. Protect the cable-side circuit according to the motor environment, maintain a low-impedance ground reference, and keep termination and biasing away from the transceiver pins except where the network configuration requires them.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für ISL8487IBZ – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | ISL8487EIBZ | MAX487ECSA+ |
|---|---|---|---|
| Brand | Renesas Electronics | Renesas Electronics | Analog Devices |
| Package | 8-SOIC | 8-SOIC | 8-SOIC |
| Product Type | Single RS-485/RS-422 transceiver | Single RS-485/RS-422 transceiver | Single RS-485/RS-422 transceiver |
| Supply Voltage | 5 V | 5 V | 5 V |
| Drivers | 1 | 1 | 1 |
| Receivers | 1 | 1 | 1 |
| ESD Protection | Yes | Yes | Yes |
Wichtigste Unterscheidungsmerkmale
- Same-family enable-polarity alternative (vs. ISL8487EIBZ)
- Multidrop loading supports compact RS-485 networks (vs. MAX487ECSA+)
- Single integrated RS-485/RS-422 channel (vs. MAX487ECSA+)
Designhinweise
Place the ISL8487IBZ near the external communication connector and route the balanced conductors as a tightly coupled differential pair. Avoid creating long stubs, discontinuities, or large loops between the transceiver and connector. Keep the interface ground reference close to the device and isolate cable-side return currents from switching-power paths. This arrangement reduces the antenna area that can convert external electromagnetic fields into differential noise.
Do not allow the ISL8487IBZ driver to remain enabled while another node transmits. Firmware should provide a defined driver-disable delay and receiver-enable strategy for half-duplex communication. Also avoid floating enable inputs because undefined control states can create contention or unreliable bus monitoring. Validate timing under the worst supported baud rate and cable length rather than relying only on nominal laboratory conditions.
Use termination and fail-safe biasing only where required by the RS-485 network topology. Excess termination can overload the driver, while insufficient or incorrectly placed termination can create reflections. Keep bias resistors physically close to the appropriate endpoint and confirm their values against the receiver threshold and the number of connected nodes. ESD protection is useful for exposed ports, but it does not replace a complete assessment of surge, ground-fault, and cable-length requirements.
Decouple the 5 V supply locally and provide a low-impedance return from the transceiver ground. Keep the supply and ground planes continuous beneath the 8-SOIC device, and observe the manufacturer's input-capacitor recommendations. Since this is an interface IC rather than a power semiconductor, SOA is not applicable; thermal design should instead focus on the system enclosure temperature and any regulator or regulator-loss contribution at the transceiver.
Compliance-Informationen
The manufacturer document describes a 5 V BiCMOS RS-485/RS-422 transceiver family, but no explicit environmental or material-compliance declarations were included in the product documentation reviewed for this entry. AEC-Q100 is not applicable to this general-purpose interface IC.