KSZ8863FLLI-TR - 3-Port 10/100 Managed Ethernet Switch | Microchip Technology (Tape & Reel)
Teilenummer: KSZ8863FLLI-TR ✓ AktivKSZ8863FLLI-TR Übersicht
An Ethernet switch controller is an interface IC that integrates multiple physical-layer transceivers and switching logic into one device. It sits within the hierarchy of Ethernet interface ICs, network controllers, semiconductors, and broader communications equipment. By combining copper and fiber-oriented connectivity in a compact package, the KSZ8863 family is intended to reduce external component count in embedded gateways, industrial controllers, access equipment, and compact network appliances.
The KSZ8863FLLI-TR includes support for optical fiber, cable diagnostics, programmable LED indication, and a low-power operating mode. Its managed-switch architecture supports controlled network segmentation and status indication, while the integrated PHYs simplify connections to 10/100BASE-T and fiber-capable downstream equipment. The I2C and SPI interfaces provide host access for configuration and management functions. According to the manufacturer product description, the KSZ8863 series is cost-sensitive, power efficient, and optimized for low-port-count switching systems.
The family variants use different suffix options to address product and ordering requirements while retaining a closely related 3-port 10/100 managed-switch architecture. The KSZ8863FLLI-TR is supplied in a 48-LQFP package, enabling conventional surface-mount assembly in industrial and embedded equipment. Its operating temperature range is specified as -40°C to +85°C, making it suitable for extended industrial environments. The 100 Mbps data rate and fiber support distinguish it from basic single-port Ethernet PHY devices.
Typical applications include industrial Ethernet gateways, serial-to-Ethernet equipment, access-point controllers, factory automation nodes, and compact embedded network appliances. Because the device combines managed switching, integrated PHYs, programmable LEDs, and low-power operation, it can simplify board design where a small network topology must operate without a discrete switch and multiple PHY packages.
The main design consideration is power and signal integrity: place the device and its decoupling network according to the manufacturer reference layout, keep high-speed traces controlled, and validate Ethernet magnetics or fiber interfaces in the final board design. Also confirm the exact fiber, LED, and management configuration for the selected KSZ8863 variant before production release.
This product page combines the verified manufacturer and distributor information, identifies package and interface details, and provides practical guidance for Ethernet switch design, sourcing, and qualification. The documented alternatives are organized by manufacturer priority and intended for engineering comparison rather than as automatic substitutions without footprint and configuration verification.
Drop-in-Alternativen für KSZ8863FLLI-TR – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit KSZ8863FLLI-TR (gleiche Bauform und Footprint) – abweichend in Ethernet Data Rate, Fiber Support, Package, Copper Ethernet Support, Power Consumption.
KSZ8863MLLI
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →KSZ8863RLL
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →KSZ8851-16MLL
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
KSZ8863FLLI-TR Grenzwerte & elektrische Eigenschaften
| Product Type | 3-Port 10/100 Managed Ethernet Switch Controller |
| Number of Ports | 3 ports |
| Ethernet Data Rate | 10 Mbps and 100 Mbps |
| Fiber Support | Yes |
| Copper Ethernet Support | 10/100 Base-TX |
| Management Interface | I2C and SPI |
| Switch Architecture | Managed 3-port switch with integrated PHYs |
| Gehäuse | 48-LQFP (7x7 mm) |
| Anzahl der Pins | 48 pins |
| Montageart | Surface Mount |
| Betriebstemperaturbereich | -40°C to +85°C |
| Cable Diagnostics | Supported |
| Programmable LED Indication | Supported |
| Low-Power Mode | Supported |
| AEC-Q100 Qualification | not_applicable |
KSZ8863FLLI-TR 48-lqfp (7x7 mm) Pinbelegungsleitfaden
Pinbelegung für KSZ8863FLLI-TR (48-lqfp (7x7 mm)-Gehäuse). Pin-Nummerierung, Funktionen und Anschlussdiagramme sind im Herstellerdatenblatt definiert. Entnehmen Sie diesem den genauen Footprint und Lötrichtlinien.
Keine detaillierten Pinbelegungsdaten verfügbar für KSZ8863FLLI-TR.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
KSZ8863FLLI-TR ist geeignet für 6 Anwendungs: Industrial Ethernet Gateway, Fiber-Capable Access Equipment, Factory Automation Network Node, Embedded Network Appliance, Serial-to-Ethernet Converter, Compact Network Power Supply Controller.
Industrial Ethernet Gateway
The KSZ8863FLLI-TR is well suited to a compact industrial Ethernet gateway because it combines a 3-port 10/100 managed switch with integrated PHYs and fiber support in one 48-LQFP 7x7 mm device. A gateway can use the managed architecture to organize copper and fiber-facing links while I2C or SPI provides host access for configuration. Its -40°C to +85°C operating range supports extended industrial environments, while programmable LED indication helps expose port status to operators. Cable diagnostics can reduce commissioning effort by identifying network faults. The design must still account for the specific media interfaces, external magnetics or fiber components, supply requirements, and thermal conditions.
Empfohlen
Fiber-Capable Access Equipment
KSZ8863FLLI-TR is appropriate for access equipment that must combine 10/100 Mbps copper connectivity with a fiber-oriented link in a small board area. The integrated three-port managed switch and fiber support can reduce the number of separate Ethernet interface devices required in compact access nodes. Its cable-diagnostics capability helps installation and maintenance teams identify link problems, while programmable LED indication supports front-panel status design. I2C and SPI interfaces allow a host processor to configure the switch and monitor status. Before layout release, confirm the exact fiber PHY arrangement, isolation strategy, connector requirements, and external component recommendations in the KSZ8863 documentation.
Empfohlen
Factory Automation Network Node
The KSZ8863FLLI-TR can provide a compact, managed Ethernet connection point in factory automation equipment where three 10/100 Mbps ports and extended-temperature operation are useful. Managed switching helps segment equipment traffic, while the low-power mode supports systems that need to reduce energy consumption during idle periods. The 48-LQFP package supports standard surface-mount manufacturing and a relatively compact solution compared with multiple discrete PHY and switch components. Cable diagnostics provide practical field-maintenance benefits, and programmable LEDs can indicate link and activity status. A complete industrial design should still validate electromagnetic immunity, isolation, grounding, Ethernet cable compatibility, and functional safety requirements where applicable.
Empfohlen
Embedded Network Appliance
The KSZ8863FLLI-TR fits embedded appliances requiring several Ethernet links without the footprint of a larger switch platform. Its three-port 10/100 managed architecture can support equipment-to-equipment links, a service uplink, and a management connection in a single controller. I2C and SPI control allow an embedded host to initialize the switch and implement link policies, while programmable LEDs provide a simple user-facing status indication. The low-power mode is useful in energy-conscious embedded systems. Designers should confirm the target power budget, thermal rise, Ethernet magnetics or fiber implementation, and whether managed features are needed; a simpler unmanaged PHY may be sufficient for less complex products.
Empfohlen
Serial-to-Ethernet Converter
KSZ8863FLLI-TR can be used as the network-switching element in a serial-to-Ethernet converter that needs more than one Ethernet port. A host processor may connect through SPI or I2C, while the switch controller handles multiple 10/100 Mbps links and optional fiber connectivity. This arrangement suits legacy serial equipment that must be connected to several network paths or exposed through a management port. Cable diagnostics and programmable LEDs improve installation and serviceability. Before choosing the device, determine whether the converter requires only one copper port, whether redundancy or managed traffic prioritization is necessary, and whether the added PHY integration is justified compared with using a single Ethernet interface IC.
Empfohlen
Compact Network Power Supply Controller
The KSZ8863FLLI-TR can be integrated into a network power product that requires an Ethernet management connection alongside other monitoring or control functions. Its managed three-port architecture offers flexibility for equipment, uplink, and service connections, while programmable LED indication can communicate operating status without a complex display. Low-power mode can be useful in fanless systems where continuous full-power operation is unnecessary. The component does not directly regulate power, so the application requires a separate power-control and monitoring architecture. Designers should keep Ethernet signal paths away from switching nodes and high-current inductors, observe grounding and decoupling recommendations, and verify the complete enclosure temperature against the -40°C to +85°C device range.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für KSZ8863FLLI-TR – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | KSZ8863MLLI | KSZ8863RLL | KSZ8851-16MLL |
|---|---|---|---|---|
| Package | 48-LQFP (7x7 mm) | 48-LQFP (7x7 mm) - family package | 48-LQFP (7x7 mm) - family package | 48-LQFP (7x7 mm) - verify exact drawing |
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Switch Function | 3-port managed Ethernet switch | KSZ8863 family managed switch | KSZ8863 family managed switch | 16-port Ethernet switch family positioning |
Wichtigste Unterscheidungsmerkmale
- Integrated three-port managed switching in a compact package (vs. KSZ8851-16MLL)
- Specific low-port-count managed-switch configuration (vs. KSZ8863MLLI)
- Fiber-capable connectivity in the same 48-LQFP footprint class (vs. KSZ8863RLL)
Designhinweise
Follow the manufacturer reference layout for the 48-LQFP device, including input/output decoupling placement and controlled routing for management, clock, and media interfaces. Place the device close to the Ethernet PHY-related circuitry and keep copper structures beneath or around the package from disturbing sensitive signal paths. Confirm land-pattern dimensions and thermal pad requirements against the exact package drawing before fabrication.
Treat Ethernet and fiber-capable connections as high-speed interfaces even though the nominal data rate is 100 Mbps. Use controlled impedance routing where required, minimize discontinuities, provide return paths, and separate communication traces from switching regulators and inductors. Validate the complete board with Ethernet magnetics, connectors, cable lengths, and the intended network environment rather than relying only on schematic-level connectivity.
Use the manufacturer's recommended supply voltage, decoupling capacitors, and power-up sequence for the selected KSZ8863 variant. The supplied product information does not state the supply-voltage range or power consumption, so obtain those values from the family datasheet before sizing the regulator and input capacitance. Check startup current, low-power mode behavior, and the maximum operating temperature against the system power budget.
Do not treat the MLL, FLL, and RLL suffixes as automatically interchangeable. Confirm the exact pin names, alternate functions, media support, LED behavior, and register or configuration differences in the manufacturer documentation for the ordered variant. A family-level compatibility statement is not enough to approve a drop-in replacement; compare the package drawing and complete pin-description tables against the current schematic.
Compliance-Informationen
The retrieved comparison material mentions RoHS and REACH status, but no explicit target-device compliance declaration is present in the verified product data. Confirm these attributes using the manufacturer product documentation and the applicable declaration files.