MAX232EWE.C70401 - 120kbps RS-232 Transceiver | Analog Devices
Teilenummer: MAX232EWE.C70401 ✓ AktivMAX232EWE.C70401 Übersicht
An RS-232 transceiver is an interface IC that bridges a computer or embedded system with a serial port by converting logic-level voltages to and from RS-232 signal levels. In the product hierarchy, the MAX232EWE.C70401 belongs to the interface IC family, then to the RS-232 driver and receiver class, and ultimately to the broader semiconductor category. It is useful where a modern controller lacks native RS-232 electrical interfaces.
The principal features include two transmit drivers, two receive receivers, operation from a +5 V supply, and support for data rates up to 120kbps. Its 16-pin SOIC package supports compact surface-mount assembly. The manufacturer identifies compliance with EIA/TIA-232E and CCITT V.28 specifications when the interface is loaded, making it applicable to conventional RS-232 equipment, control systems, instrumentation, and industrial data links.
The MAX232 family uses charge-pump circuitry to develop the bipolar voltage swings required by RS-232 from a single +5 V supply. This architecture allows the IC to operate with a single positive rail while presenting logic-compatible signals to the connected controller. Although the product page groups the MAX232E among its multichannel RS-232 driver and receiver devices, it specifically identifies the MAX202E and MAX232E as available in 16-pin TSSOP, narrow SO, wide SO, and DIP package options.
Typical uses include connecting a 5 V microcontroller or processor to a legacy RS-232 console, instrumentation interface, maintenance port, or industrial controller. The two-driver and two-receiver arrangement supports two communication channels in one package. The maximum specified data rate of 120kbps exceeds common serial-console rates, although the complete link must also satisfy the timing and signal-integrity requirements of the connected equipment.
PCB implementation should follow the manufacturer's pin description and recommended decoupling arrangement exactly. Keep the charge-pump and interface layout shown in the datasheet, provide the specified supply capacitance, route RS-232 driver outputs away from sensitive analog nodes, and account for the higher voltage and current on the cable side of the interface. The complete pin assignment should be taken from the package drawing because the exact exposed-pad and no-connect details must match the ordered package variant.
This page combines the exact manufacturer interface specifications, ordering information, package data, sourcing links, and practical application guidance. It also identifies genuine same-family alternatives while distinguishing verified drop-in choices from options that require package or design revalidation.
Drop-in-Alternativen für MAX232EWE.C70401 – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
MAX232EWE+
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →MAX232EWE
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
MAX232EWE.C70401 Technische Daten
| Product Type | RS-232 transceiver interface IC |
| Driver and Receiver Channels | 2 drivers and 2 receivers |
| Versorgungsspannung | +5 V |
| Maximum Data Rate | 120kbps |
| Gehäuse | 16-pin SOIC |
| Montageart | Surface mount |
| Interface Standard | EIA/TIA-232E and CCITT V.28 |
| Standard Compliance Condition | Specified when loaded |
| Signal Direction Support | Bidirectional through separate drivers and receivers |
MAX232EWE.C70401 16-pin soic Pinbelegungsleitfaden
Pinbelegung für MAX232EWE.C70401 (16-pin soic-Gehäuse). Pin-Nummerierung, Funktionen und Anschlussdiagramme sind im Herstellerdatenblatt definiert. Entnehmen Sie diesem den genauen Footprint und Lötrichtlinien.
Keine detaillierten Pinbelegungsdaten verfügbar für MAX232EWE.C70401.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
MAX232EWE.C70401 ist geeignet für 6 Anwendungs: Legacy RS-232 Console Interface, Industrial Controller Serial Port, Test and Measurement Equipment, Instrumentation Data Link, Equipment Maintenance Port, Point-to-Point Serial Communication.
Legacy RS-232 Console Interface
The MAX232EWE.C70401 fits a legacy console connection where a 5 V controller must communicate through a conventional RS-232 port. Its two driver channels carry outgoing serial data, while two receiver channels support incoming control or status messages. Operation from a +5 V supply and support for data rates up to 120kbps provide ample performance for common console baud rates. The 16-pin SOIC package also keeps the interface compact compared with larger discrete driver and receiver arrangements. Confirm the exact C70401 pin assignment and connector-side net names from the manufacturer documentation before layout release.
Empfohlen
Industrial Controller Serial Port
The MAX232EWE.C70401 is appropriate for an industrial controller that exposes a service or configuration port through RS-232. The two-driver and two-receiver arrangement allows bidirectional communication without separate interface ICs, while the specified 120kbps maximum rate supports common serial-control traffic when the cable and loading conditions are acceptable. Its +5 V supply operation integrates naturally with 5 V control logic. Because industrial cables can introduce ESD and ground-potential problems, use the recommended interface layout and add appropriate connector-side protection rather than relying solely on the IC.
Empfohlen
Test and Measurement Equipment
MAX232EWE.C70401 can translate a controller’s logic-level UART into the voltage levels expected by RS-232 test equipment. The manufacturer rates the MAX232E family for data rates up to 120kbps when loaded and for EIA/TIA-232E and CCITT V.28 interface specifications. This makes the IC useful in programmable instruments, laboratory interfaces, and service ports where an established RS-232 device is connected to a modern embedded controller. Keep the cable-side traces away from sensitive measurement circuitry and follow the manufacturer’s recommended charge-pump and decoupling layout.
Empfohlen
Instrumentation Data Link
The MAX232EWE.C70401 suits instrumentation that must exchange commands and measurements with a host over RS-232. Two transmit and two receive channels allow more than one direction to be implemented in a single package, while the 120kbps rated rate exceeds the throughput typically needed for periodic telemetry. Using the IC in a +5 V system simplifies the logic-side connection to a compatible UART. Validate cable length, grounding, receiver thresholds, and connector protection for the installation because those system-level factors determine practical reliability outside the IC package.
Empfohlen
Equipment Maintenance Port
MAX232EWE.C70401 provides a practical interface for a maintenance or diagnostic port on embedded equipment. A service adapter can connect its logic-level UART to the equipment through the MAX232E’s RS-232 drivers and receivers, enabling configuration, firmware-status exchange, and basic diagnostics. The integrated 2/2 transceiver arrangement reduces the number of separate interface components, and the 16-pin SOIC package supports compact board layouts. Ensure the service connector includes suitable ESD protection and that the selected baud rate remains compatible with the full cable and loading path.
Empfohlen
Point-to-Point Serial Communication
The MAX232EWE.C70401 works for short point-to-point links between two logic systems using RS-232 cabling. Its separate transmitter and receiver channels support full-duplex communication, while its +5 V operation and 120kbps capability cover many control, status, and low-bandwidth data exchanges. The EIA/TIA-232E and CCITT V.28 compatibility stated by Analog Devices provides a familiar electrical target for the cable side. Designers should still follow the recommended board layout, observe the interface’s loading limits, and verify grounding and connector-pin conventions between the two connected systems.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für MAX232EWE.C70401 – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | MAX232EWE+ | MAX232EWE |
|---|---|---|---|
| Package | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Product Function | +5 V RS-232 transceiver | +5 V RS-232 transceiver | +5 V RS-232 transceiver |
| Driver Channels | 2 | 2 | 2 |
| Receiver Channels | 2 | 2 | 2 |
| Maximum Data Rate | 120kbps | 120kbps | 120kbps |
| Supply Voltage | +5 V | +5 V | +5 V |
| Interface Standards | EIA/TIA-232E and CCITT V.28 when loaded | EIA/TIA-232E and CCITT V.28 when loaded | EIA/TIA-232E and CCITT V.28 when loaded |
Wichtigste Unterscheidungsmerkmale
- Two complete transmit and receive paths in one IC (vs. MAX232EWE+)
- Supports up to 120kbps under the manufacturer’s loaded condition (vs. MAX232EWE)
- Single +5 V implementation with established RS-232 specifications (vs. MAX232EWE)
Designhinweise
Follow the manufacturer’s recommended charge-pump and RS-232 layout for the exact 16-pin SOIC variant. Place the specified input and charge-pump capacitors adjacent to their designated pins, keep the protected pin and charge-pump nodes compact, and avoid routing sensitive signals through the noisy region around the internal switching node. Assign the connector-side nets directly from the pin-description table rather than from a generic MAX232 drawing.
Treat the cable-facing RS-232 nets as bipolar, high-impedance signal paths and keep them away from clocks, ADC inputs, references, and other sensitive analog nodes. Provide the specified bypass capacitance at the supply pins and use a short return-path-aware connector layout. Although the family supports rates up to 120kbps when loaded, practical margin depends on cable length, receiver loading, baud-rate tolerance, and connector construction.
Do not treat MAX232EWE, MAX232EWE+, and MAX232EWE.C70401 as automatically interchangeable solely because the package name is identical. Confirm the ordering suffix, revision, pin description, temperature grade, and supply details before replacing a released BOM item. Also verify RS-232 connector DTE and DCE pin assignments at the system level, because a valid level translator does not by itself guarantee correct connector wiring.
Compliance-Informationen
The manufacturer states EIA/TIA-232E and CCITT V.28 interface compliance when loaded. No specific RoHS, REACH, lead-free, halogen-free, or conflict-minerals declaration was established for this ordering code.