NXP Semiconductors

MPX5050GP - 0-50kPa Vented Gauge Pressure Sensor | NXP

Teilenummer: MPX5050GP ✓ Aktiv
Auf Lager Versand in 1–3 Werktagen
0.2 V to 4.7 V Vdss 7 mA nominal Id 6-SIP Module Package
Ab $7.85 USD / Stück
MOQ: 1 |
Preis aktualisiert: 2026-10-15
Mengenpreise
Menge Stückpreis Gesamt
1 $12.5 $12,50
10 $11.25 $112,50
100 $9.8 $980,00
500 $8.65 $4.325,00
1.000 $7.85 $7.850,00
ℹ️ Alle Preise sind in USD

MPX5050GP Übersicht

The NXP MPX5050GP is a monolithic piezoresistive silicon pressure sensor with on-chip signal conditioning, temperature compensation, and calibration, housed in a 6-SIP module with a 0.19 inch (4.93 mm) male tube port for vented gauge measurement of 0 to 50 kPa (0 to 7.25 PSI).

An integrated silicon pressure sensor is a transducer that converts an applied pressure into a proportional analog voltage using a piezoresistive strain gauge bridge etched directly into a silicon die, with on-chip op-amp and thin-film resistor networks providing amplification, temperature compensation, and calibration. In the broader sensor hierarchy, this part is a pressure sensor (synonym: pressure transducer), which falls under the MEMS sensor category and ultimately the sensor/transducer family of electronic components, interfacing to a microcontroller or ADC.

Key features include a ratiometric analog output from 0.2 V to 4.7 V over the specified pressure range, 2.5 percent maximum accuracy (per the verified distributor data), 7 mA nominal supply current, and an operating temperature range of -40 C to +125 C. The sensor is designed for 5 V nominal supply (4.75 V to 5.25 V), with a maximum overpressure rating of 7 PSI (approximately 2x the full-scale range) per typical MPX5050 family ratings.

The MPX5050GP uses a bipolar op-amp architecture combined with laser-trimmed thin-film resistors to deliver a high-level output signal and accurate temperature compensation across its operating range. The vented gauge (GP) configuration references the rear side of the die to ambient atmosphere, providing absolute differential measurement relative to barometric pressure for applications such as altitude estimation or vacuum-relative sensing.

Typical applications include HVAC pressure monitoring, respiratory/medical equipment, level measurement, altitude estimation for drones or portable devices, and industrial process control where a clean 5 V rail-driven analog pressure signal is required. The automotive-qualified variants within the MPX5050 family make this family popular for manifold absolute pressure (MAP) sensing and barometric absolute pressure (BAP) sensing applications.

When designing with this device, ensure a stable, low-noise 5 V supply because the output is ratiometric. Decoupling capacitors (typically 100 nF) should be placed close to the supply pin. The output is analog and should feed an ADC with adequate resolution (10-bit minimum recommended for the 4.5 V swing to cover 7.25 PSI with ~7 mV/PSI resolution).

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet, providing a compact reference for engineers selecting a 50 kPa vented gauge pressure sensor.

Drop-in-Alternativen für MPX5050GP – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit MPX5050GP (gleiche Bauform und Footprint) – abweichend in Operating Temperature, Package, Output Type, Supply Voltage, Technology.

NXP Semiconductors
Operating Temperature: 0 °C to 85 °C
Package: 8-DIP Module (Case 1560-02)
Output Type: Analog Voltage, Ratiometric
Vergleichen mit MPX5050GP →
NXP Semiconductors
Operating Temperature: -40C to +125C (per MPX2010 series datasheet)
Output Type: Wheatstone Bridge (analog voltage)
Supply Voltage: 10 V to 16 V
Vergleichen mit MPX5050GP →
NXP Semiconductors
Operating Temperature: -40 °C to +125 °C
Package: 6-SIP Module (Unibody)
Output Type: Analog, Ratiometric
Vergleichen mit MPX5050GP →
NXP Semiconductors
Operating Temperature: -40C to +125C
Package: 6-SIP Module (SOT1693-1 / Case 1351-01)
Output Type: Analog ratiometric voltage
Vergleichen mit MPX5050GP →
NXP Semiconductors
Package: 6-SIP Module (through-hole)
Technology: Piezoresistive, monolithic silicon
Vergleichen mit MPX5050GP →
NXP Semiconductors
Operating Temperature: 0C to +85C
Package: 8-SMD, Gull Wing, Side Port (SO SOT1693-1)
Output Type: Analog, ratiometric
Vergleichen mit MPX5050GP →

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

MPX5050GP1

✅ Drop-In
📦 6-SIP Module
same 6-SIP package, same die, predecessor part now EOL

📋 Referenzalternative (nicht im Katalog)

MPX5050DP

✅ Drop-In
NXP Semiconductors
📦 6-SIP Module
NXP Semiconductors · Differential Pressure Sensor · Piezoresistive (MEMS silicon) · 0 kPa to 50 kPa (0 PSI to 7.25 PSI) · Differential, dual tube port (Male, 0.19" / 4.93 mm Tube) · Analog ratiometric voltage · 0.2 V to 4.7 V · 4.5 V typical

✓ Auf Lager

$8.65 / Stück

Datenblatt ansehen →

MPX5050D

✅ Drop-In
NXP Semiconductors
📦 6-SIP Module
Differential Pressure Sensor · 0 kPa to 50 kPa (0 to 7.25 PSI) · Analog, Ratiometric · 0.2 V to 4.7 V · 4.75 V to 5.25 V (5 V typical) · 7 mA (typical) · ±1.5% (over 0 to 50 kPa) · 1 ms (typical)

✓ Auf Lager

$9.85 / Stück

Datenblatt ansehen →

XGZP6885A

✅ Drop-In
📦 6-SIP Module (similar)
0-50kPa ratiometric analog output, 5V supply, similar through-hole SIP, cross-brand equivalent

📋 Referenzalternative (nicht im Katalog)

MPX5050GP Grenzwerte & elektrische Eigenschaften

Pressure Type Vented Gauge
Pressure Range 0 kPa to 50 kPa (0 PSI to 7.25 PSI)
Maximum Overpressure 200 kPa (per MPX5050 family)
Ausgangstyp Analog Voltage (ratiometric)
Ausgangsspannungsbereich 0.2 V to 4.7 V
Versorgungsspannung 4.75 V to 5.25 V (5 V nominal)
Versorgungsstrom 7 mA nominal
Accuracy 2.5% (per distributor data)
Betriebstemperatur -40 C to +125 C
Port Type 0.19 inch (4.93 mm) Male Tube, Vented
Gehäuse 6-SIP Module
Montageart Through-Hole
Technology Piezoresistive MEMS, on-chip conditioned
RoHS-Status Compliant
Temperature Compensation On-chip, calibrated

MPX5050GP Pin-Konfiguration

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pin 1 VCC — 5V supply input
Pin 2 GND — Ground reference
Pin 3 VOUT — Analog pressure output (0.2V-4.7V)
Pin 4 NC — Not connected (per datasheet)
Pin 5 NC — Not connected (per datasheet)
Pin 6 NC — Not connected (per datasheet)

Typische Anwendungen

MPX5050GP ist geeignet für 6 Anwendungs: HVAC Pressure Monitoring, Medical Respiratory Equipment, Drone Altitude Estimation, Liquid Level Measurement, Industrial Process Control, Barometric Weather Stations.

🏭

HVAC Pressure Monitoring

The MPX5050GP's 0-50 kPa vented gauge range and 0.2 V to 4.7 V ratiometric analog output make it well-suited for HVAC duct pressure measurement and air filter monitoring systems. With 2.5% accuracy and on-chip temperature compensation across -40 C to +125 C, the sensor delivers stable readings in rooftop air handler units and variable-air-volume (VAV) box controllers. Placed inside the duct with the male tube port facing the airflow, the device feeds a 10-12 bit ADC input on the HVAC controller. Unlike differential pressure sensors, the vented gauge configuration provides absolute pressure relative to barometric conditions, which is needed for indoor air quality calculations. The 5 V supply can be shared with the controller's analog rail, simplifying wiring.

💊

Medical Respiratory Equipment

The MPX5050GP suits medical respiratory devices including spirometers, CPAP machines, and ventilator pressure monitoring circuits because its 0-50 kPa range covers typical airway pressure spans while the ratiometric analog output interfaces cleanly to medical-grade ADC front-ends. The on-chip temperature compensation maintains accuracy across clinical operating environments, and the 6-SIP through-hole package supports easy cleaning and sterilization of the patient-side tubing path. Place the male tube port on the patient circuit with 100 nF decoupling on the 5 V supply pin for noise immunity. Unlike disposable pressure sensors, the MPX5050GP is a reusable component suitable for equipment manufacturers; designers should verify FDA or CE medical device compliance separately for the complete system.

✈️

Drone Altitude Estimation

The MPX5050GP's vented gauge configuration makes it ideal for drone altitude estimation where barometric pressure provides height-above-ground references for flight controllers. The 0-50 kPa range covers the full atmospheric pressure span from sea level to high altitudes, and the 4.5 V output swing gives roughly 90 mV per kPa sensitivity for ADC conversion at 5 V supply. With 7 mA supply current and a small 6-SIP module footprint, the device fits within size-constrained drone avionics bays. Place the vent port facing rearward away from propeller wash to avoid dynamic pressure errors. Designers should pair this with a 12-bit ADC for ~0.1 meter altitude resolution and apply altitude-temperature correction in firmware for best accuracy.

🏭

Liquid Level Measurement

The MPX5050GP works well in liquid level measurement systems where the vented gauge port is connected via tubing to the bottom of a tank, and the vent reference compensates for atmospheric pressure changes on the liquid surface. The 0-50 kPa range covers approximately 5 meters of water column, suitable for small to mid-size tanks. With on-chip temperature compensation, the device maintains accuracy across varying fluid temperatures from -40 C to +125 C. The ratiometric output drives a 4-20 mA current loop converter or a direct ADC input for tank monitoring displays. Unlike ultrasonic or capacitive level sensors, the MPX5050GP requires fluid contact via the pressure port and is best suited for closed-tank applications.

🏭

Industrial Process Control

The MPX5050GP is a reliable choice for industrial process control loops measuring gas or low-pressure fluid line pressures in the 0-50 kPa range, including cleanroom pressure monitoring and pneumatic system diagnostics. With 2.5% accuracy, ratiometric analog output, and on-chip temperature compensation, the sensor delivers repeatable readings suitable for PLC and SCADA system inputs. The 6-SIP through-hole package provides robust mechanical mounting on industrial control board assemblies, and the 5 V supply integrates with standard 24 V-to-5 V industrial power rails. Place a 100 nF decoupling capacitor close to the supply pin, and consider adding a TVS diode for surge protection in electrically noisy factory environments.

🌐

Barometric Weather Stations

The MPX5050GP serves barometric weather stations where atmospheric pressure measurement in the 0-50 kPa span is needed for weather prediction and altitude calibration. The vented gauge configuration references the rear side of the die directly to ambient atmosphere, providing accurate absolute pressure without requiring external venting hardware. With ratiometric output, the device feeds an ADC input on the weather logger MCU using the same 5 V rail, simplifying power architecture. The on-chip temperature compensation maintains accuracy across the -40 C to +125 C operating range, suitable for outdoor weather station enclosures. Designers should apply firmware compensation for altitude above sea level for true barometric pressure reporting.

What is the pressure range of the MPX5050GP?
The MPX5050GP measures 0 kPa to 50 kPa (0 PSI to 7.25 PSI) in a vented gauge configuration. According to the NXP MPX5050 datasheet, the output spans 0.2 V to 4.7 V over this range, giving roughly 90 mV per kPa sensitivity when powered from a 5 V rail. The vented gauge port references atmospheric pressure, so the device reads differential pressure relative to ambient barometric conditions.
What is the difference between MPX5050GP and MPX5050DP?
The MPX5050GP is a vented gauge sensor with a male tube port and the suffix GP denotes gauge with port, exposing the back side of the die to ambient air. The MPX5050DP is the differential dual-port variant with two tube ports measuring pressure difference between two points. Both share the same 0-50 kPa range and 0.2 V to 4.7 V ratiometric output, but only the GP is suitable for barometric or altitude-style applications.
What is the difference between MPX5050GP and MPX5050GP1?
According to NXP community documentation, the MPX5050GP is the active production part while the MPX5050GP1 has reached end-of-life status. Both share the same 0-50 kPa vented gauge sensor core with ratiometric analog output. For new designs, engineers should specify the active MPX5050GP rather than the EOL MPX5050GP1 to avoid supply issues.
Where to buy MPX5050GP online?
The MPX5050GP is available from major distributors including DigiKey (stocking PWS4700), Mouser, Arrow, and Win Source, with NXP also supporting direct orders for larger volumes. As of 2026-10-15, distributor pricing on the active part is approximately $12.50 at qty-1, scaling down to roughly $7.85 at qty-1000. Lead time is generally 4-8 weeks for production quantities.
What is the price of MPX5050GP?
The MPX5050GP distributor price as of 2026-10-15 is approximately $12.50 USD at quantity 1 from major franchised distributors. Volume pricing drops to around $9.80 at qty-100 and $7.85 at qty-1000. The MPXV5050GP variant from NXP carries a budgetary 1K pricing of $10.66 USD per NXP's product page for tray-packaged orders with a 250-piece minimum order quantity.
Is MPX5050GP in stock at distributors?
The MPX5050GP is generally in stock at major distributors including DigiKey and Mouser as of 2026-10-15. The part is listed as active in the NXP product lifecycle, with distributor pages showing ready-to-ship inventory and RFQ options for production quantities. Check distributor websites for real-time stock levels because inventory fluctuates daily.
What is the lead time for MPX5050GP?
The MPX5050GP standard lead time from major distributors is typically 4-8 weeks for production volumes as of 2026-10-15. Small prototype quantities (under 100 pieces) are usually available from distributor shelf stock with same-day shipping. For urgent requirements, contact NXP directly or authorized distributors for expedited production scheduling.
MPX5050GP vs MPX5050DP - which is better for altitude sensing?
The MPX5050GP is the correct choice for altitude or barometric sensing because it is a vented gauge sensor that references atmospheric pressure on the rear side of the die, providing absolute pressure relative to barometric conditions. The MPX5050DP measures differential pressure between two ports and would require external atmospheric referencing, adding complexity and reducing accuracy. Choose MPX5050GP for drone altitude, weather stations, and HVAC applications.
When should I choose MPX5050GP over MPXV5050GP?
Choose the MPX5050GP when you need a vented gauge sensor in a 6-SIP module with male tube port for through-hole PCB mounting. Choose the MPXV5050GP when you need the same 0-50 kPa vented gauge functionality but in a surface-mount SO-8 package for SMT assembly lines. Both share the same pressure range, accuracy, and ratiometric output characteristics.
What is the best drop-in replacement for MPX5050GP?
The closest drop-in replacement is the MPXV5050GP, which shares the same 0-50 kPa vented gauge range and ratiometric output but uses a different SO-8 surface-mount footprint requiring PCB rework. For true same-package 6-SIP through-hole drop-in, the MPX5050GP1 was the predecessor and is now EOL. Cross-brand alternatives like the CFSensor XGZP6885A offer similar electrical performance in a different physical package.
Where to download MPX5050GP datasheet PDF?
The MPX5050GP datasheet PDF is available from NXP's official website at https://www.nxp.com/part/MPX5050GP and is mirrored on distributor sites including Mouser (https://www.mouser.com/datasheet/2/302/MPX5050-3138730.pdf). The datasheet contains the complete pressure transfer function, temperature compensation curves, application circuits, and mechanical drawings of the 6-SIP module package.
What is the output voltage of MPX5050GP at 0 kPa?
The MPX5050GP outputs 0.2 V at 0 kPa (zero pressure) when powered from a 5 V supply, per the NXP MPX5050 datasheet. This offset is intentional and accounts for the sensor's null-pressure offset. At the full-scale pressure of 50 kPa, the output reaches 4.7 V, giving a 4.5 V total span for ADC conversion across the operating range.
Does MPX5050GP require temperature compensation?
The MPX5050GP has on-chip bipolar op-amp circuitry and laser-trimmed thin-film resistor networks that provide temperature compensation and calibration across the -40 C to +125 C operating range. Per the NXP MPX5050 datasheet, no external temperature compensation is required for typical applications. The device delivers a calibrated output with 2.5% accuracy over the specified pressure and temperature range.
Can MPX5050GP be used for medical respiratory applications?
Yes, the MPX5050GP is suitable for medical respiratory equipment including spirometers and ventilator pressure monitoring because its 0-50 kPa range covers typical airway pressure ranges, and the ratiometric analog output interfaces directly to medical-grade ADC inputs. The on-chip temperature compensation maintains accuracy across the operating range required for clinical environments. Verify regulatory compliance separately for FDA or CE medical device certification.
What ADC resolution is recommended for MPX5050GP?
A 10-bit ADC is the minimum recommended resolution for the MPX5050GP, providing approximately 4.4 mV per LSB across the 4.5 V output span, yielding roughly 4.5 PSI per LSB. For higher accuracy applications, a 12-bit ADC provides 1.1 mV per LSB, which is recommended for medical or precision industrial applications. The ratiometric output means ADC readings should use the same 5 V supply as the sensor reference for best accuracy.

Technische Referenzdaten für MPX5050GP – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the MPX5050GP for new designs when you require a 0-50 kPa vented gauge pressure sensor in a 6-SIP through-hole package with 5 V ratiometric analog output. Select the MPX5050DP when measuring differential pressure between two points (such as flow across an orifice). Choose the MPX5050D for the simplest differential sensor without port integration. For surface-mount assembly, select the MPXV5050GP variant instead, which uses an SO-8 package but requires PCB redesign. For new designs avoiding the EOL MPX5050GP1, the active MPX5050GP is the appropriate choice. Consider the cross-brand XGZP6885A when NXP supply is constrained, but verify pin mapping against the NXP datasheet because pin assignments may differ.

Vergleich mit Alternativen

Parameter Dieses Produkt MPX5050GP1 MPX5050DP MPX5050D XGZP6885A
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors CFSensor
Package 6-SIP Module 6-SIP Module - same 6-SIP Module - same 6-SIP Module - same 6-SIP Module (similar)
Pressure Range 0-50 kPa 0-50 kPa 0-50 kPa 0-50 kPa 0-50 kPa
Pressure Type Vented Gauge Vented Gauge Differential (dual port) Differential (basic) Gage
Output Voltage 0.2V to 4.7V 0.2V to 4.7V 0.2V to 4.7V 0.2V to 4.7V 0.5V to 4.5V
Supply Voltage 5V nominal 5V nominal 5V nominal 5V nominal 5V nominal
Lifecycle Status Active EOL Active Active Active

Wichtigste Unterscheidungsmerkmale

  • Vented gauge port for absolute barometric reference (vs. MPX5050DP)
  • Active production status vs predecessor EOL (vs. MPX5050GP1)
  • Wider output span for higher ADC utilization (vs. XGZP6885A)

Designhinweise

Use a clean, regulated 5 V supply (4.75 V to 5.25 V) for the MPX5050GP because the output is ratiometric. Supply noise directly couples into the output through the on-chip reference; a low-noise LDO (such as an LP2985 or equivalent) feeding the sensor is recommended. Place a 100 nF ceramic decoupling capacitor as close to pin 1 (VCC) as possible, with a bulk 10 uF tantalum or ceramic cap on the supply rail to handle transient current demands during pressure changes.

The 6-SIP module's male tube port must be mounted with the port facing away from PCB components to allow pneumatic tubing connection. Ensure adequate mechanical support for the through-hole pins because vibration or pressure-induced flexing can introduce measurement error or fatigue the solder joints. For high-vibration environments (such as drones or industrial machinery), consider adding a strain-relief clamp on the tubing at the port entrance.

Route the analog output trace (pin 3) away from digital switching signals, switching power supply nodes, and high-current traces. Use a ground plane under the sensor for shielding, and consider a small RC low-pass filter (1 kohm + 100 nF, giving ~1.6 kHz cutoff) on the output to reduce high-frequency noise if the ADC sampling rate is below 100 Hz. The output impedance of the MPX5050GP is relatively low, so a unity-gain buffer is generally not required for ADC input loads above 10 kohm.

Do not block the vent hole on the rear of the 6-SIP module - this is the gauge reference and blocking it will cause measurement drift with ambient pressure changes. For applications where condensation or contamination is possible, add a hydrophobic filter on the vent port. Also, do not apply pressure exceeding 200 kPa (the maximum overpressure rating) as this can permanently damage the silicon diaphragm.

Compliance-Informationen

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Bleifrei
Yes
Halogenfrei
Unknown
Konfliktmineralien
Compliant

RoHS compliant per NXP product page. The MPX5050 family is not AEC-Q100 qualified for automotive applications - choose MPXV5050GP or automotive-specific variants for vehicle designs. Conflict minerals compliance per NXP standard reporting.

Daten verifiziert am: 2026-10-15 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

MPX5050GP MPX5050GP datasheet NXP MPX5050GP 50kPa pressure sensor 5V analog 6-SIP vented gauge sensor MPX5050GP HVAC application MPX5050GP vs MPX5050DP MPX5050GP drop-in replacement MPX5050GP buy price what is the pressure range of MPX5050GP MPX5050GP pinout 6-SIP barometric pressure sensor 0-50kPa

Verwandte Bauteile & Begriffe

NXP Semiconductors MPX5050GP MPX5050GP1 MPX5050DP MPX5050D XGZP6885A pressure sensor pressure transducer vented gauge piezoresistive MEMS sensor ratiometric output 6-SIP module RoHS AEC-Q100 temperature compensation monolithic silicon bipolar op-amp HVAC barometric pressure
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen