NXP Semiconductors

MPX5010GP - 0-10kPa Vented Gauge Pressure Sensor | NXP

Teilenummer: MPX5010GP ✗ Abgekündigt
Auf Lager Versand in 1–3 Werktagen
4.75 V to 5.25 V (typical 5 V) Vdss 6-SIP module (Unibody) Package
Ab $10.85 USD / Stück
MOQ: 1 |
Preis aktualisiert: 2026-10-15
Mengenpreise
Menge Stückpreis Gesamt
1 $18.5 $18,50
10 $16.2 $162,00
100 $14.05 $1.405,00
500 $12.4 $6.200,00
1.000 $10.85 $10.850,00
ℹ️ Alle Preise sind in USD

MPX5010GP Übersicht

The NXP MPX5010GP is an integrated silicon piezoresistive pressure sensor that delivers a calibrated, temperature-compensated analog output for gauge pressures from 0 to 10 kPa (0 to 1.45 PSI). Housed in a 6-SIP through-hole module with a 0.19" (4.93 mm) male tube port for vented gauge measurements, it accepts a 5 V supply and produces a ratiometric output spanning approximately 0.2 V to 4.7 V, providing 4.5 V of useful dynamic range that maps directly onto the input range of most 5 V ADCs.

What is a gauge pressure sensor? A gauge pressure sensor measures pressure referenced to ambient atmospheric pressure through a vent port, distinguishing it from absolute sensors (which reference a sealed vacuum) and differential sensors (which measure between two ports). Within the broader sensor hierarchy, the MPX5010GP sits as a pressure transducer in the sensors category, where piezoresistive MEMS technology dominates low-pressure applications due to its high sensitivity, small size, and CMOS-compatible signal conditioning.

Key features include on-chip signal conditioning that eliminates the need for external amplification, factory calibration that reduces part-to-part variation to approximately ±1.5% per the datasheet, and integrated temperature compensation from 0 °C to 85 °C. The 0.2 V to 4.7 V ratiometric output is referenced to the 5 V supply, ensuring noise immunity and accurate conversion when paired with a 5 V ADC reference.

The sensor combines advanced micromachining, thin-film metallization, and bipolar semiconductor processing on a single monolithic die. A piezoresistive bridge etched into the silicon diaphragm converts mechanical strain into a millivolt-level differential signal, which the on-chip ASIC amplifies, calibrates, and linearizes to produce the final analog output with minimal user-side conditioning.

Typical applications include medical respiratory monitoring such as CPAP and spirometry, HVAC differential pressure sensing, industrial process control, vacuum cleaner and appliance load sensing, and altitude estimation in drones and portable instruments. The combination of low-pressure sensitivity and analog ratiometric output makes the MPX5010GP especially useful where ADC integration is straightforward and battery life is not the primary constraint.

When designing with this part, take care to mount the SIP package vertically on the PCB so the port faces downward or sideways, matching the recommended manifold geometry in the datasheet to avoid pressure measurement errors caused by port orientation. Decouple the 5 V supply with a 100 nF ceramic capacitor placed close to the sensor supply pin to suppress switching noise from downstream digital circuitry.

This page synthesizes distributor pricing, drop-in pin-compatible alternatives, application-grade recommendations, and practical design notes not found in a single source on the manufacturer datasheet.

Drop-in-Alternativen für MPX5010GP – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit MPX5010GP (gleiche Bauform und Footprint) – abweichend in Package, Mounting Type, Operating Temperature, Supply Voltage, Accuracy.

STMicroelectronics
Package: 8-SMD Module
Mounting Type: Surface Mount
Operating Temperature: 0 to 85 degrees Celsius
Vergleichen mit MPX5010GP →
NXP Semiconductors
Package: 8-SMD, Gull Wing, SOP-8
Mounting Type: Surface Mount
Operating Temperature: 0°C to +85°C
Vergleichen mit MPX5010GP →
NXP Semiconductors
Mounting Type: Through-Hole (vertical SIP)
Supply Voltage: 4.75 V to 5.25 V
Accuracy: ±1.5% (typical, full-scale, 0°C to 85°C)
Vergleichen mit MPX5010GP →
NXP Semiconductors
Package: 6-SIP Module (6-pin Single Inline Package)
Mounting Type: Through-hole SIP module
Operating Temperature: -40C to +125C
Vergleichen mit MPX5010GP →
NXP Semiconductors
Package: 6-SIP Module
Mounting Type: Through-hole (SIP)
Operating Temperature: 0 C to +85 C (compensated)
Vergleichen mit MPX5010GP →
NXP Semiconductors
Package: 6-SIP Module, Case 867E-03
Mounting Type: Through-hole, axial tube
Operating Temperature: 0 C to +85 C (compensated)
Vergleichen mit MPX5010GP →
NXP Semiconductors
Package: SOP-8 surface mount
Mounting Type: Surface Mount
Operating Temperature: -40 °C to +125 °C
Vergleichen mit MPX5010GP →
NXP Semiconductors
Mounting Type: Through Hole
Operating Temperature: 0 C to 85 C
Accuracy: 1.0 % typical (per datasheet)
Vergleichen mit MPX5010GP →
STMicroelectronics
Package: 8-SMD, Gull Wing, Side Port
Mounting Type: Surface Mount
Operating Temperature: 0 C to +85 C
Vergleichen mit MPX5010GP →

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

MPXV5010GP

✅ Drop-In
STMicroelectronics
📦 6-SIP Unibody
Vented Gauge · 0 kPa to 10 kPa (0 PSI to 1.45 PSI) · 10 kPa · Analog Voltage · 0.2 V to 4.7 V · 5 V · 5 mA typical · 450 mV/kPa (approx, 0.2-4.7 V span)

✓ Auf Lager

$9.95 / Stück

Datenblatt ansehen →

MPX5010GS

✅ Drop-In
NXP Semiconductors
📦 6-SIP Unibody
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · 4.75 V to 5.25 V (5 V typical) · 5 mA typical · 0.2 V to 4.7 V at 5 V supply · +/-2.5% of full-scale span · 1.0 ms typical

✓ Auf Lager

$10.85 / Stück

Datenblatt ansehen →

MPX5010GSX

✅ Drop-In
NXP Semiconductors
📦 6-SIP Unibody
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · Analog Voltage · 0.2 V to 4.7 V · 4.5 V to 5.5 V · 1.0 % typical (per datasheet)

✓ Auf Lager

$10.25 / Stück

Datenblatt ansehen →

XGZP6885A

✅ Drop-In
📦 6-pin SIP compatible
third-party alternative, same 10 kPa range and ratiometric analog output, different supplier

📋 Referenzalternative (nicht im Katalog)

MP3V5010GP

✅ Drop-In ⚠️ Spezifikationen ungeprüft
📦 6-SIP small outline
same 0-10 kPa range, smaller outline package variant of MPX5010 family

📋 Referenzalternative (nicht im Katalog)

MPX5010GP Grenzwerte & elektrische Eigenschaften

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 10 kPa (0 to 1.45 PSI)
Versorgungsspannung 4.75 V to 5.25 V (typical 5 V)
Ausgangstyp Analog, ratiometric
Ausgangsspannungsbereich 0.2 V to 4.7 V
Full-Scale Span 4.5 V (typical)
Zero Pressure Offset 0.2 V typical at VS = 5 V
Accuracy ±1.5% (per datasheet, factory calibrated)
Compensated Temperature 0 °C to 85 °C
Port Configuration Male 0.19" (4.93 mm) tube, single vented port
Gehäuse 6-SIP module (Unibody)
Technology Piezoresistive MEMS with on-chip ASIC
Montageart Through-Hole

MPX5010GP Pin-Konfiguration

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pin 1 Vout — Analog pressure output (0.2 V to 4.7 V)
Pin 2 GND — Ground
Pin 3 Vs — 5 V supply input
Pin 4 NC — Not connected (per datasheet)
Pin 5 NC — Not connected (per datasheet)
Pin 6 NC — Not connected (per datasheet)

Typische Anwendungen

MPX5010GP ist geeignet für 6 Anwendungs: Medical Respiratory Monitoring (CPAP / Spirometry), HVAC Differential / Static Pressure Sensing, Industrial Vacuum and Process Control, Consumer Appliance Load / Vacuum Sensing, Drone and Portable Altitude Estimation, Blood Pressure Monitor Air-Pressure Sensing.

💊

Medical Respiratory Monitoring (CPAP / Spirometry)

The MPX5010GP's 0 to 10 kPa range aligns precisely with the breath-pressure envelope encountered in CPAP machines, spirometers, and ventilator circuit monitoring, where pressures typically span 0.5 to 6 kPa during normal respiration. Its ratiometric analog output spanning 0.2 V to 4.7 V connects directly to a 5 V medical-grade ADC, preserving calibration accuracy when the supply drifts by ±2.5%. The on-chip temperature compensation from 0 °C to 85 °C maintains sensor accuracy across the warm-up phase of a CPAP humidifier and the cooler bedside environment of a hospital ward. Plumbed into the patient airway tube via the 0.19" male port, it provides real-time airflow data for closed-loop pressure control without requiring external amplification or linearization.

🏭

HVAC Differential / Static Pressure Sensing

In HVAC duct and filter monitoring applications, the MPX5010GP delivers the static pressure measurements (0 to 10 kPa) needed to detect clogged air filters, blocked coils, or fan performance issues. Its vented gauge port references ambient pressure, allowing installation at any point in the ductwork without altitude recalibration. The 4.5 V analog swing provides enough resolution to detect sub-100 Pa pressure drops when paired with a 12-bit or higher ADC, while the on-chip signal conditioning eliminates external op-amps that would otherwise need thermal management. Building automation controllers can read the sensor via a single ADC channel and convert the value to Pascal units with minimal firmware overhead.

🏭

Industrial Vacuum and Process Control

The MPX5010GP is well matched to low-vacuum industrial processes such as packaging seal integrity testing, pick-and-place vacuum verification, and pneumatic gripper feedback, where pressures of 0 to 10 kPa cover the typical operating envelope. Its ±1.5% factory calibration supports direct use in process-control loops without inline trim, and its 5 V single-supply operation simplifies integration with PLC analog input modules. The 6-SIP Unibody package withstands typical industrial vibration when properly retained, and the on-chip ASIC eliminates long analog signal paths that would otherwise pick up motor and relay noise.

🧩

Consumer Appliance Load / Vacuum Sensing

In vacuum cleaner suction control and washing-machine water-level switches, the MPX5010GP provides a low-cost analog pressure reading that maps to load or blockage conditions. Its ratiometric output is tolerant of the long, unregulated wiring typically found in appliances, and the 0.2 V zero offset can be trimmed out in software using the existing motor controller's ADC. The on-chip temperature compensation keeps readings accurate across the cold-start to full-load thermal envelope of an appliance cycle, and the standard 0.19" male port mates with inexpensive flexible tubing used throughout the appliance industry.

✈️

Drone and Portable Altitude Estimation

Drones and handheld outdoor instruments can use the MPX5010GP for low-cost altitude estimation when paired with a temperature reference, leveraging the linear relationship between atmospheric pressure and elevation. The 0 to 10 kPa range corresponds to about 0 to 8 kPa deviations from sea-level reference (offset handling required in firmware), and the ratiometric output preserves accuracy as the LiPo battery drains from 4.2 V to 3.7 V with appropriate reference scaling. The compact 6-SIP package suits dense flight-controller boards, and the on-chip amplifier reduces external BOM count - a critical factor for weight-sensitive UAV designs.

💊

Blood Pressure Monitor Air-Pressure Sensing

The MPX5010GP serves as the air-pressure transducer in electronic sphygmomanometers, where it reads cuff pressure from 0 to roughly 30 kPa during inflation and 0 to about 20 kPa during measurement, well within the 10 kPa range when paired with a controlled cuff deflation rate. Its analog output drives an ADC-based oscillometric algorithm that infers systolic and diastolic pressures from the cuff pulsation envelope. The on-chip temperature compensation and ±1.5% factory calibration ensure readings remain consistent across ambient conditions encountered in pharmacies, clinics, and home use.

Zusammenfassung der empfohlenen Produkte

MAX86140EVSYS Optical pulse-ox biosensor reference platform Verwendet in: Medical Respiratory Monitoring (CPAP / Spirometry) MPXV5010GP STMicroelectronics Verwendet in: Medical Respiratory Monitoring (CPAP / Spirometry), Blood Pressure Monitor Air-Pressure Sensing ADuCM361 Low-power precision analog MCU for medical sensor readout Verwendet in: Medical Respiratory Monitoring (CPAP / Spirometry), Blood Pressure Monitor Air-Pressure Sensing MPX5050DP NXP Semiconductors Verwendet in: HVAC Differential / Static Pressure Sensing MPL3115A2 I2C barometric altimeter for reference pressure Verwendet in: HVAC Differential / Static Pressure Sensing, Drone and Portable Altitude Estimation MPX5100GP NXP Semiconductors Verwendet in: Industrial Vacuum and Process Control MAX11270 24-bit sigma-delta ADC for high-precision process readings Verwendet in: Industrial Vacuum and Process Control MPX5010DP NXP Semiconductors Verwendet in: Consumer Appliance Load / Vacuum Sensing MAX31855 Thermocouple converter for temperature compensation Verwendet in: Drone and Portable Altitude Estimation
What is the operating pressure range of MPX5010GP?
The MPX5010GP measures gauge pressure from 0 to 10 kPa, equivalent to 0 to 1.45 PSI. According to the manufacturer datasheet, the ratiometric analog output is calibrated to span approximately 0.2 V to 4.7 V across this 10 kPa full-scale range when supplied at 5 V, delivering 4.5 V of usable signal swing for a downstream ADC.
What supply voltage does MPX5010GP require?
The MPX5010GP operates from a 4.75 V to 5.25 V single supply, with 5.0 V being the nominal design point. The output is ratiometric to the supply, so using a clean, well-regulated 5 V rail with a 100 nF ceramic decoupling capacitor near the supply pin is recommended for stable, low-noise pressure readings.
How accurate is MPX5010GP?
The MPX5010GP is factory calibrated to within ±1.5% of the full-scale span per the manufacturer datasheet. On-chip temperature compensation from 0 °C to 85 °C minimizes drift across normal operating conditions, eliminating the need for external linearization in most microcontroller-based designs.
What is the output type of MPX5010GP?
The MPX5010GP delivers a ratiometric analog voltage output spanning 0.2 V to 4.7 V, which is proportional to the applied gauge pressure and scales linearly with the 5 V supply. This analog output is well suited to direct connection to the ADC input of a 5 V microcontroller such as an NXP Kinetis or S08 device.
Where to buy MPX5010GP online?
MPX5010GP is available from major distributors including DigiKey and Mouser as of 2026-10-15. Pricing at 1-unit quantity is approximately $18.50, with volume pricing down to about $10.85 at 1000 pieces. Stock should be confirmed directly with each distributor due to the limited availability listed in cross-reference data.
What is the lead time for MPX5010GP?
Lead time for the MPX5010GP varies by distributor and reel size as of 2026-10-15. The cross-reference data flags this part as having "limited" supply and demand status, with an estimated EOL date in 2025. For long-production designs, request a formal lifecycle confirmation from NXP before committing the bill of materials.
Is MPX5010GP in stock?
Stock availability for MPX5010GP fluctuates because the cross-reference data indicates the part is approaching end-of-life and showing limited supply. As of 2026-10-15, DigiKey and Mouser list the part, but live inventory and order quantities should be checked at order entry to avoid line-down situations during production.
What is the best drop-in replacement for MPX5010GP?
The best drop-in alternative is the MPXV5010GP from NXP, which shares the 10 kPa range and a similar SIP-style port interface, or the XGZP6885A from CF Sensor, which is a third-party pin-compatible gauge sensor covering the same 10 kPa scale. Both options retain the ratiometric 0.2 V to 4.7 V analog interface, simplifying firmware recalibration.
MPX5010GP vs MPX5010DP - what is the difference?
The MPX5010GP is a vented gauge sensor with one pressure port referenced to ambient atmosphere, while the MPX5010DP is a differential sensor with two opposing ports measuring the pressure difference between them. Both share the 10 kPa range and similar output span, but their port configurations and reference schemes differ, so the choice depends on whether the application measures relative to atmosphere or between two points.
Can MPX5010GP be used for medical respiratory monitoring?
Yes, the MPX5010GP is well suited to medical respiratory monitoring such as CPAP airflow sensing and spirometry, where the 0 to 10 kPa range covers typical breath-pressure levels. Its analog ratiometric output interfaces directly with a 5 V medical-grade ADC, and the on-chip temperature compensation maintains accuracy across normal clinical operating conditions.
Where to download MPX5010GP datasheet PDF?
The MPX5010GP datasheet PDF can be downloaded from the ST product page at https://www.st.com/resource/en/datasheet/mpx5010dp.pdf or from NXP's product page at https://www.nxp.com/part/MPX5010GP. Both distributors DigiKey and Mouser link to this same manufacturer datasheet on their MPX5010GP product listings.
What is the pinout of MPX5010GP?
The MPX5010GP pinout in the 6-SIP Unibody package assigns pins 1, 2, and 3 to the output-side group (typically Vout, GND, and VS) and pins 4, 5, 6 to the input-side group, with the port on the device top. Always confirm the exact mapping against the datasheet figure before PCB layout, since pin numbering varies slightly between similar NXP/MPX sensor packages.
When should I choose MPX5010GP over MPXV5010G?
Choose the MPX5010GP for higher-accuracy designs where the SIP Unibody package and tighter factory calibration are required, particularly in medical instrumentation. Choose the MPXV5010G when a smaller surface-mount footprint is preferred for compact industrial or consumer products; both deliver the same 10 kPa gauge range and ratiometric analog output, simplifying firmware reuse.
What does the 'G' suffix in MPX5010GP mean?
The 'G' suffix in MPX5010GP indicates a vented gauge pressure configuration referenced to ambient atmosphere through a single port, and the 'P' suffix denotes the specific port and package geometry used here (a male 0.19" tube on a 6-SIP Unibody body). NXP uses these letter codes to differentiate between gauge, differential, and absolute variants within the MPX5010 family.
What are the key specifications of MPX5010GP that engineers should know?
The MPX5010GP combines a 0 to 10 kPa gauge range, 5 V ratiometric supply with 4.5 V output span, ±1.5% factory accuracy, and 0 °C to 85 °C temperature compensation in a 6-SIP Unibody through-hole package. On-chip signal conditioning eliminates external amplifiers and the 0.19" male tube port simplifies pneumatic manifold integration for medical, HVAC, and industrial designs.

Technische Referenzdaten für MPX5010GP – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the MPX5010GP when you need a calibrated, temperature-compensated vented gauge pressure sensor with a 0 to 10 kPa range and a robust through-hole SIP package for medical, HVAC, or industrial designs. Choose the MPXV5010GP when you need a surface-mount variant for compact consumer or portable products. Choose the MPX5010GS or MPX5010GSX when you need the same electrical performance in an alternative port geometry for pneumatic manifold integration. Choose the XGZP6885A from CF Sensor for cost-sensitive designs where third-party sourcing is acceptable and an alternate supply chain is desired. For designs beyond 10 kPa, consider the MPX5050, MPX5100, or MPX5700 family members, which share the same pinout and interface but extend the range upward.

Vergleich mit Alternativen

Parameter Dieses Produkt MPXV5010GP MPX5010GS MPX5010GSX XGZP6885A
Package 6-SIP Unibody (through-hole) Surface-mount small outline 6-SIP Unibody (axial port) 6-SIP Unibody (port variant) 6-pin SIP compatible
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors CF Sensor (third-party)
Pressure Range 0 to 10 kPa (0 to 1.45 PSI) 0 to 10 kPa 0 to 10 kPa 0 to 10 kPa 10 kPa (range configurable)
Pressure Type Vented Gauge Vented Gauge Vented Gauge Vented Gauge Vented Gauge
Supply Voltage 5.0 V (4.75 V to 5.25 V) 5.0 V 5.0 V 5.0 V 5.0 V (also 3.3 V option)
Output Type Analog ratiometric 0.2 V to 4.7 V Analog ratiometric Analog ratiometric Analog ratiometric Analog ratiometric
Accuracy ±1.5% full-scale ±1.5% ±1.5% ±1.5% ±1% (typical, depending on grade)
Temperature Compensation 0 °C to 85 °C (on-chip) 0 °C to 85 °C 0 °C to 85 °C 0 °C to 85 °C 0 °C to 60 °C or extended

Wichtigste Unterscheidungsmerkmale

  • On-chip signal conditioning and temperature compensation (vs. XGZP6885A)
  • Through-hole SIP Unibody package (vs. MPXV5010GP)
  • Established NXP medical-grade heritage (vs. MPX5010GS (NXP variant, port only))

Designhinweise

Place a 100 nF ceramic decoupling capacitor within 5 mm of the MPX5010GP supply pin to suppress switching noise from nearby digital logic. Use wide, short traces for Vs and GND, and consider a small RC filter (for example, 100 ohm plus 100 nF) on the output line to reduce ADC sample-to-sample variation caused by MCU reference noise.

Mount the sensor with the pressure port facing downward or sideways as shown in the datasheet; mounting the port face-up can trap moisture or debris and introduce zero-shift errors. Avoid running pneumatic tubing across sharp PCB edges and use flexible silicone tubing rated for negative pressure if used in vacuum or pump-side applications.

Because the output is ratiometric to Vs, use the same 5 V rail - or a precisely divided reference of it - as the ADC reference voltage. Using an independent ADC reference and varying Vs will produce apparent pressure shifts; this is a common source of "drift" complaints that are actually a design-level calibration issue rather than sensor inaccuracy.

Do not exceed the maximum overload pressure specification (see datasheet) - applying overpressure can permanently alter the zero offset and degrade linearity. Avoid connecting the vent port to a sealed volume; the sensor requires atmospheric reference to function as a gauge device. For liquid media, install an inline isolation membrane; the silicon die is not rated for direct liquid contact.

Compliance-Informationen

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Bleifrei
Unknown
Halogenfrei
Not Compliant
Konfliktmineralien
Unknown

Cross-reference data flags the part as 'Halogen Free: Not Compliant'. RoHS, REACH, lead-free, and conflict-mineral status were not directly provided in the verified web data and are listed as 'unknown' pending manufacturer or distributor datasheet confirmation.

Daten verifiziert am: 2026-10-15 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

MPX5010GP datasheet MPX5010GP pressure sensor 10 kPa NXP MPX5010GP analog output MPX5010GP vs MPX5010DP MPX5010GP 6-SIP pressure transducer vented gauge pressure sensor 5V analog MPX5010GP medical CPAP pressure sensor MPX5010GP drop-in replacement buy MPX5010GP DigiKey Mouser what is the supply voltage of MPX5010GP MPX5010GP pinout SIP low cost 10 kPa pressure sensor MCU

Verwandte Bauteile & Begriffe

NXP Semiconductors STMicroelectronics MPX5010GP MPXV5010GP MPX5010GS MPX5010GSX MP3V5010GP XGZP6885A pressure sensor gauge pressure transducer vented gauge sensor piezoresistive MEMS monolithic silicon pressure sensor ratiometric analog output 6-SIP Unibody package medical respiratory monitoring HVAC static pressure RoHS REACH on-chip signal conditioning temperature compensation ADC interface factory calibration
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen