NXP Semiconductors

MPXV4006GC6U - 6 kPa Gauge Pressure Sensor, 5V, SOP-8 | NXP

Teilenummer: MPXV4006GC6U ✓ Aktiv
Auf Lager Versand in 1–3 Werktagen
0.2 V to 4.7 V Vdss 8-SMD, Gull Wing, Top Port Package
Ab $9.2 USD / Stück
MOQ: 1 |
Preis aktualisiert: 2026-10-15
Mengenpreise
Menge Stückpreis Gesamt
1 $12.5 $12,50
10 $11.25 $112,50
100 $10.83 $1.083,00
500 $9.95 $4.975,00
1.000 $9.2 $9.200,00
ℹ️ Alle Preise sind in USD

MPXV4006GC6U Übersicht

The NXP MPXV4006GC6U is an integrated silicon piezoresistive pressure sensor delivering a calibrated, temperature-compensated analog output from 0.2 V to 4.7 V across a 0 kPa to 6 kPa (0 to 0.87 PSI) gauge pressure range, housed in an 8-SMD gull-wing top-port package. According to the NXP MPXV4006G datasheet, it operates from a single 5 V supply and provides a near-linear transfer function suited for microcontroller ADC input.

A pressure sensor is a transducer that converts an applied pressure into a measurable electrical signal. Piezoresistive sensors achieve this by exploiting the change in resistance of silicon strain gauges diffused into a diaphragm; when pressure deflects the diaphragm, the resistors form a Wheatstone bridge whose differential output is proportional to pressure. On-chip signal conditioning, calibration, and temperature compensation in the MPXV4006GC6U eliminate the need for external analog circuitry, which is a key reason this part dominates in cost-sensitive medical, consumer, and HVAC designs.

Key features of the MPXV4006GC6U include a 0 kPa to 6 kPa operating range, ratiometric analog output, 5 V single-supply operation, and top-port 1/8 inch tube pressure inlet. The 8-SMD gull-wing package supports surface-mount assembly, while the integrated compensation delivers typically ±1.5% accuracy over 0°C to 85°C. The sensor also provides a 10 ms typical response time, enabling real-time pressure tracking in dynamic flow systems.

Technically, the MPXV4006G family uses a monolithic silicon die combining the mechanical diaphragm and the analog ASIC in a single chip. This co-integration reduces long-term drift compared with hybrid assemblies and enables a small footprint with high reliability. The 0.2 V to 4.7 V swing keeps the signal well within the 5 V ADC input range of common microcontrollers such as the NXP Kinetis and S32K families.

Typical applications include respiratory monitoring in medical devices, HVAC differential pressure sensing, air-flow measurement in variable-air-volume boxes, appliance water-level detection, weather-station barometric compensation, and process-control gauge monitoring. The integrated signal path allows designers to read pressure with a single ADC channel and minimal firmware calibration.

When designing with this part, route the top-port tube away from vibration sources and PCB flexure, and add a small RC filter on the VOUT node if the ADC input is high-impedance to attenuate conducted EMI. Decouple the supply with a 0.1 µF ceramic capacitor placed within 5 mm of the VCC pin.

Drop-in-Alternativen für MPXV4006GC6U – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit MPXV4006GC6U (gleiche Bauform und Footprint) – abweichend in Package, Supply Voltage, Technology, Operating Pressure Range, Operating Temperature.

NXP Semiconductors
Package: 8-SMD Module (SOP-8 equivalent)
Supply Voltage: 4.75 V to 5.25 V (5 V typ)
Technology: Piezoresistive MEMS, bipolar signal chain
Vergleichen mit MPXV4006GC6U →
NXP Semiconductors
Package: 8-SMD Module (SOP-8 with port)
Technology: Piezoresistive (silicon MEMS)
Operating Temperature: -10 °C to +85 °C
Vergleichen mit MPXV4006GC6U →
STMicroelectronics
Package: 8-BSOP (0.475" / 12.06 mm width), Dual Ports, Same Side
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Technology: Piezoresistive, Monolithic Silicon, On-chip Signal Conditioned, Temperature Compensated, Calibrated
Vergleichen mit MPXV4006GC6U →
NXP Semiconductors
Package: 8-SMD, Gull Wing, Top Port
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Technology: Piezoresistive MEMS
Vergleichen mit MPXV4006GC6U →
NXP Semiconductors
Package: 8-DIP Module (through-hole, no port variant)
Supply Voltage: 4.75 V to 5.25 V
Technology: Piezoresistive MEMS with on-chip ASIC
Vergleichen mit MPXV4006GC6U →
STMicroelectronics
Package: 8-SMD, Gull Wing, Top Port (SOP 8 with integrated tube)
Supply Voltage: 5.0 V typical
Technology: Piezoresistive MEMS, Bipolar Signal Conditioning
Vergleichen mit MPXV4006GC6U →
STMicroelectronics
Package: 8-DIP (0.550 in / 13.97 mm), top port
Supply Voltage: 5 V (typ)
Operating Pressure Range: 0 kPa to 6 kPa
Vergleichen mit MPXV4006GC6U →
NXP Semiconductors
Package: 8-SMD SOP, Gull Wing, Side Port
Supply Voltage: 4.75 V to 5.25 V (typical 5 V)
Technology: Piezoresistive MEMS
Vergleichen mit MPXV4006GC6U →
NXP Semiconductors
Package: 8-SMD Gull Wing Module
Supply Voltage: 4.75 V to 5.25 V (5 V nominal)
Technology: Piezoresistive (MEMS)
Vergleichen mit MPXV4006GC6U →

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

MPXV4006GC7U

✅ Drop-In
STMicroelectronics
📦 8-SMD, Gull Wing, Top Port
0 kPa to 6 kPa · Vented Gauge (differential referenced to atmosphere) · 0.2 V to 4.7 V (typ) · Analog ratiometric · 5 V (typ) · ±1.5 %VFSS (typical)

✓ Auf Lager

$10.5 / Stück

Datenblatt ansehen →

MPXV4006GC6T1

✅ Drop-In
STMicroelectronics
📦 8-SMD, Gull Wing, Top Port
Pressure Sensor - Vented Gauge · 0 to 6 kPa (0 to 0.87 PSI) · Analog Voltage · 0.2 V to 4.7 V · 5.0 V typical · Approx. 6 mA · Top Port, Male 0.13" (3.17 mm) Tube

✓ Auf Lager

$4.75 / Stück

Datenblatt ansehen →

MPXV4006DP

✅ Drop-In
STMicroelectronics
📦 8-SMD (die package, uncompensated)
Differential · 0 kPa to 6 kPa (0 psi to 0.87 psi) · 4.75 V to 5.25 V (5 V typical) · Analog, Ratiometric · 0.2 V to 4.7 V · ~766 mV/kPa (approx., based on 4.5 V/6 kPa span) · 0.2 V nominal at 5 V supply

✓ Auf Lager

$7.75 / Stück

Datenblatt ansehen →

MPXV4006GC6U Grenzwerte & elektrische Eigenschaften

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 6 kPa (0 to 0.87 PSI)
Ausgangstyp Analog, Ratiometric
Ausgangsspannungsbereich 0.2 V to 4.7 V
Versorgungsspannung 5 V DC (typical)
Gehäuse / Bauform 8-SMD, Gull Wing, Top Port
Port Size Male, 1/8 inch (3.175 mm) Tube
Termination Style Surface Mount (PCB)
Accuracy ±1.5% (typical, 0°C to 85°C)
Betriebstemperatur 0°C to +85°C
Response Time 10 ms (typical)
Technology Piezoresistive, Monolithic Silicon
Signal Conditioning On-chip amplified and calibrated
Montageart Surface Mount

MPXV4006GC6U Pin-Konfiguration

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
Pin 1 VCC — 5 V supply input
Pin 2 GND — Ground reference
Pin 3 VOUT — Analog ratiometric pressure output (0.2 V to 4.7 V)
Pin 4 NC — No internal connection (mechanical pin)
Pin 5 NC — No internal connection (mechanical pin)
Pin 6 NC — No internal connection (mechanical pin)
Pin 7 NC — No internal connection (mechanical pin)
Pin 8 NC — No internal connection (mechanical pin)

Typische Anwendungen

MPXV4006GC6U ist geeignet für 6 Anwendungs: Medical Respiratory Monitoring, HVAC Differential Pressure Sensing, Air-Flow Measurement in VAV Systems, Appliance Water-Level Detection, Weather Station Barometric Compensation, Process Control Gauge Monitoring.

💊

Medical Respiratory Monitoring

The MPXV4006GC6U fits medical respiratory monitoring because its 0 kPa to 6 kPa range spans the typical breathing-circuit pressures used in CPAP, ventilator, and spirometer designs. Its 0.2 V to 4.7 V ratiometric output connects directly to a microcontroller ADC running at 5 V, eliminating the need for external instrumentation amplifiers. The on-chip calibration and temperature compensation reduce firmware burden, while the 10 ms response time tracks breath-to-breath pressure transients in real time. For patient-contact designs, add a bacterial filter on the top-port tube and verify biocompatibility of all gas-path components per ISO 10993.

🏭

HVAC Differential Pressure Sensing

In HVAC variable-air-volume boxes and duct-pressure monitoring, the MPXV4006GC6U measures 0 kPa to 6 kPa with high linearity, allowing direct readout of duct static pressure for damper control algorithms. Its vented gauge reference compensates for ambient barometric shifts automatically, simplifying outdoor installations. The 8-SMD top-port package mounts on the equipment control board, and the 1/8 inch tube inlet accepts standard pneumatic fittings used in commercial HVAC. Compared with discrete bridge-based designs, the integrated signal path reduces PCB area and BOM count significantly.

🌐

Air-Flow Measurement in VAV Systems

Variable-air-volume flow measurement uses a Pitot tube or flow element to generate a differential pressure, which the MPXV4006GC6U converts to an analog voltage for the building automation controller. The 0.2 V to 4.7 V output gives adequate resolution across typical flow ranges, while the ratiometric output tracks the controller's ADC reference. Engineers commonly pair this sensor with thermistor-based temperature compensation for mass-flow calculation. The top-port tube interface simplifies pneumatic plumbing on the control board, and the surface-mount package eliminates hand-wiring in production.

🔧

Appliance Water-Level Detection

The MPXV4006GC6U detects water level in dishwashers, washing machines, and beverage dispensers by sensing hydrostatic pressure at the bottom of a vertical standpipe. Its 6 kPa ceiling covers typical appliance water-column heights, and the integrated signal conditioning means no external amplifier is needed. The vented gauge reference compensates for atmospheric pressure changes that would otherwise cause false readings. Designers should use a food-grade tube and isolation diaphragm to keep the sensor dry and serviceable across the appliance lifetime.

📱

Weather Station Barometric Compensation

Consumer weather stations use the MPXV4006GC6U for barometric pressure trending and altimeter correction in handheld GPS units. Its low power consumption and small footprint suit battery-powered enclosures, while the calibrated output drives an ADC channel directly. Vented gauge operation means absolute atmospheric readings require software subtraction of local sea-level pressure, which most firmware libraries provide as a calibration constant. The 10 ms response time is more than adequate for the slow-changing weather variables it measures.

🏭

Process Control Gauge Monitoring

Industrial process-control panels use the MPXV4006GC6U to monitor low-pressure clean-room, vacuum-pump, and filter-status applications where 0 kPa to 6 kPa spans the operating envelope. The integrated calibration reduces long-term drift compared with uncompensated transducers, extending calibration intervals. Its 0°C to 85°C operating range covers most factory-floor enclosures without additional thermal management. Engineers typically add a TVS diode and current-limiting resistor on the supply pin to meet industrial EMC requirements.

What is the operating pressure range of MPXV4006GC6U?
The MPXV4006GC6U measures gauge pressure from 0 kPa to 6 kPa, equivalent to 0 to 0.87 PSI. According to the NXP MPXV4006G datasheet, the device outputs 0.2 V at 0 kPa and 4.7 V at 6 kPa with a 5 V supply, making it suitable for low-pressure respiratory and HVAC applications. The vented gauge reference means the device senses pressure relative to ambient atmospheric pressure.
What supply voltage does MPXV4006GC6U require?
The MPXV4006GC6U operates from a single 5 V DC supply. According to the NXP datasheet, the analog output is ratiometric with VCC, so any ADC reference tied to VCC will track the pressure reading accurately even if the supply sags. A 0.1 µF decoupling capacitor within 5 mm of the supply pin is recommended to suppress digital switching noise.
Is the MPXV4006GC6U pin-compatible with the MPXV4006GC7U?
Yes, the MPXV4006GC6U and MPXV4006GC7U share the same 8-SMD gull-wing top-port package and pinout according to a sequential database comparison. The two parts exhibit identical performance profiles across the primary technical parameters. The difference lies in operating pressure range, so verify the maximum pressure rating for your application before substituting.
What is the output voltage of MPXV4006GC6U at 0 kPa?
The MPXV4006GC6U outputs 0.2 V at 0 kPa (zero applied gauge pressure). According to the NXP datasheet, this offset is trimmed on-chip and tracks the supply voltage. Engineers typically read this zero-pressure voltage at startup to perform a single-point software calibration, removing long-term offset drift caused by board-level stress on the package.
Can MPXV4006GC6U be used for medical respiratory applications?
Yes, the MPXV4006GC6U is well suited to low-pressure medical respiratory monitoring. Its 0 kPa to 6 kPa range covers typical breathing-circuit pressures, and its 10 ms response time tracks airflow transients accurately. Designers should add an external bacterial filter on the top-port tube and validate biocompatibility of all gas-path materials per ISO 10993 if the device contacts the patient gas stream.
Where can I download the MPXV4006GC6U datasheet PDF?
The MPXV4006GC6U datasheet PDF is available directly from NXP at https://www.nxp.com/docs/en/data-sheet/MPXV4006G.pdf. The document covers electrical characteristics, package dimensions, application circuits, and recommended PCB layout. Datasheet mirrors are also available from distributor sites such as DigiKey and Mouser, but the NXP-hosted copy is the authoritative revision.
What is the pinout of the MPXV4006GC6U 8-SMD package?
The MPXV4006GC6U uses the standard MPXV4006G series 8-SMD pinout documented in the NXP datasheet. Pins 1 through 8 are assigned to VCC, GND, VOUT, and several NC/no-connect pins used for mechanical stability. Always confirm pin assignments against the latest datasheet revision before PCB layout, as mechanical-only pins must still be soldered for package reliability.
How accurate is the MPXV4006GC6U across temperature?
The MPXV4006GC6U delivers ±1.5% typical accuracy across the 0°C to 85°C operating range according to the NXP datasheet. On-chip temperature compensation calibrates the offset and span over temperature, eliminating the need for external analog trim. For tighter accuracy in HVAC or medical designs, a 2-point software calibration at 0 kPa and 6 kPa further reduces residual error.
What is the lead time for MPXV4006GC6U when out of stock at distributors?
When distributor stock runs out, MPXV4006GC6U typically has a 6 to 12 week factory lead time from NXP. Authorised distributors such as DigiKey and Mouser allow backorder with real-time factory updates, while independent brokers may carry spot stock at higher prices. Order minimum quantity at the factory is 1200 pieces per the NXP product page, so smaller runs must source from franchised distribution.
Where to buy MPXV4006GC6U online at the best price?
The MPXV4006GC6U is available from authorised distributors including DigiKey, Mouser, Arrow, and Avnet. As of 2026-10-15, the budgetary 1k-piece price from NXP is $10.83 USD, while single-piece retail pricing at distribution typically runs $12 to $14 USD. Always verify the supplier is franchised to avoid counterfeit risk on pressure sensors with safety implications.
Is MPXV4006GC6U in stock at major distributors right now?
Stock varies by distributor and date. The DigiKey product page at https://www.digikey.com/en/products/detail/stmicroelectronics/MPXV4006GC6U/1168426 lists real-time inventory and ships most orders same-day. For production volumes, request a quote from NXP or an authorised distributor to lock factory allocation and avoid spot-market volatility.
What is the difference between MPXV4006GC6U and MPXV4006GC6T1?
The MPXV4006GC6U and MPXV4006GC6T1 share the same 0 to 6 kPa pressure range, 0.2 V to 4.8 V output, and 8-pin SMT package. The terminal suffixes differ: GC6U ships in tubes while GC6T1 ships in tape-and-reel for high-volume assembly. Both are fully interchangeable electrically and are direct drop-in replacements for each other.
MPXV4006GC6U vs MPXV4006DP - which is better for HVAC airflow sensing?
For HVAC airflow sensing, the MPXV4006GC6U is the better choice because it outputs a 0.2 V to 4.7 V ratiometric signal across 0 kPa to 6 kPa, which matches the differential pressure range of variable-air-volume boxes. The MPXV4006DP is a uncompensated bare die variant requiring external signal conditioning, increasing BOM cost and design time. Choose MPXV4006GC6U for production-ready HVAC designs.
What is the best drop-in replacement for MPXV4006GC6U?
The best drop-in replacement is the MPXV4006GC7U from the same MPXV4006G family, sharing the 8-SMD gull-wing top-port package and pin-for-pin compatible footprint. It differs only in operating pressure range ceiling, so verify your application pressure before substituting. For supply continuity, also evaluate the MPXV4006GC6T1 reel-pack variant which is electrically identical to the tube-pack GC6U.
What is the response time of MPXV4006GC6U?
The MPXV4006GC6U has a typical response time of 10 ms according to the NXP MPXV4006G datasheet. This speed comfortably tracks breathing-cycle waveforms at typical respiratory rates and HVAC duct pressure oscillations. For high-bandwidth acoustic or shock-wave applications, an external buffer amplifier may be needed to drive the capacitive ADC sample-and-hold input.

Technische Referenzdaten für MPXV4006GC6U – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the MPXV4006GC6U when you need a calibrated, temperature-compensated 0 to 6 kPa gauge pressure sensor with a 5 V supply and 0.2 V to 4.7 V ratiometric output in an 8-SMD top-port package. It is the best fit for medical respiratory, HVAC duct pressure, and appliance water-level designs where on-chip signal conditioning is mandatory. Choose MPXV4006GC7U if your application requires a higher pressure ceiling - it shares the same footprint. Choose MPXV4006GC6T1 for high-volume reel-pack assembly; it is electrically identical to the GC6U. Choose MPXV4006DP only when you need a raw bridge output for custom analog signal chains.

Vergleich mit Alternativen

Parameter Dieses Produkt MPXV4006GC7U MPXV4006GC6T1 MPXV4006DP
Package 8-SMD, Gull Wing, Top Port 8-SMD, Gull Wing, Top Port - same 8-SMD, Gull Wing, Top Port - same 8-SMD (uncompensated die) - similar footprint
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Operating Pressure Range 0 kPa to 6 kPa 0 kPa to higher ceiling (variant-specific) 0 kPa to 6 kPa - identical 0 kPa to 6 kPa (uncompensated)
Output Voltage Range 0.2 V to 4.7 V 0.2 V to 4.7 V (family-standard) 0.2 V to 4.7 V - identical Raw bridge output, no integrated scaling
Signal Conditioning On-chip amplified and calibrated On-chip amplified and calibrated On-chip amplified and calibrated - identical Uncompensated, requires external op-amps
Supply Voltage 5 V DC 5 V DC 5 V DC 5 V DC (bridge excitation)
Packaging Form Tube (40 pcs) Tube Tape & Reel Tray (bare die)
Drop-in Compatibility Reference Pin-compatible, range-different Pin-compatible, packaging-only difference Same family, requires external conditioning

Wichtigste Unterscheidungsmerkmale

  • Higher operating pressure ceiling for same-package drop-in upgrade path (vs. MPXV4006GC7U)
  • Tape-and-reel packaging option for high-volume assembly (vs. MPXV4006GC6T1)
  • Fully integrated signal conditioning reduces BOM (vs. MPXV4006DP)

Designhinweise

Place a 0.1 µF ceramic decoupling capacitor within 5 mm of the VCC pin and a 1 nF to 10 nF capacitor on the VOUT trace if the ADC sample-and-hold capacitor is large. The top-port pressure inlet must be oriented vertically to avoid liquid ingress, and the vent hole on the package underside must remain unblocked to preserve gauge accuracy. Reference the NXP application note for land-pattern dimensions.

Do not apply pressure exceeding the maximum rated range or expose the sensor to liquids that can enter the top-port tube without a downstream filter. Avoid exposing the package to mechanical stress on the PCB, since the silicon diaphragm is sensitive to board flexure near the sensor. Confirmed by NXP datasheet, the supply must remain within 4.75 V to 5.25 V for specified accuracy.

Route the VOUT trace away from switching converter inductors and digital clock lines, using a ground guard trace on either side for long runs. The output is ratiometric, so tie the ADC reference to the same VCC rail to maintain absolute accuracy when the supply drifts. Add an RC low-pass filter (1 kΩ + 100 nF) at the ADC input if the application has high-frequency noise, accepting the ~0.1 ms filter delay.

Compliance-Informationen

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Bleifrei
Yes
Halogenfrei
Unknown
Konfliktmineralien
Compliant

RoHS and lead-free confirmed per NXP product page. Pressure sensor is not an AEC-Q100 qualified automotive part - choose MPXVxxxxGC6U automotive variants if AEC-Q100 is required.

Daten verifiziert am: 2026-10-15 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

MPXV4006GC6U MPXV4006GC6U datasheet NXP MPXV4006GC6U 6 kPa gauge pressure sensor 5V 8-SMD top port pressure sensor MPXV4006GC6U medical respiratory MPXV4006GC6U vs MPXV4006GC7U MPXV4006GC6U drop-in replacement MPXV4006GC6U price buy MPXV4006GC6U pinout 8-SMD HVAC differential pressure sensor 6 kPa low pressure transducer 0.87 PSI

Verwandte Bauteile & Begriffe

NXP Semiconductors MPXV4006GC6U MPXV4006GC7U MPXV4006GC6T1 MPXV4006DP piezoresistive pressure sensor gauge pressure monolithic silicon sensor Wheatstone bridge signal conditioning ratiometric output RoHS REACH 8-SMD gull-wing 1/8 inch tube port HVAC medical respiratory monitoring calibration temperature compensation
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen