SWA70-CA2A2A1 Übersicht

The Endress+Hauser SWA70-CA2A2A1 is a WirelessHART Adapter module from the SWA70 family that wirelessly transmits 4 to 20 mA and HART signals from connected field devices to a WirelessHART Fieldgate (gateway). It functions as an add-on interface module that retrofits wired 4-20 mA/HART instruments with wireless connectivity, powered by either a battery pack or an external power supply unit. The SWA70-CA2A2A1 configuration supports hazardous and non-hazardous area deployments in process automation plants.

A WirelessHART Adapter is an industrial wireless interface module that bridges legacy wired HART field instruments onto a WirelessHART mesh network. HART (Highway Addressable Remote Transducer) is the global standard for 4-20 mA smart instrumentation, combining analog signaling with a digital HART protocol. WirelessHART extends this standard to IEC 62591 (HART over IEEE 802.15.4 radio at 2.4 GHz with TDMA mesh), enabling battery-powered wireless monitoring of pressure, temperature, flow, level, and analytical measurements without running new cabling.

Key features of the SWA70 WirelessHART Adapter family include dual power options (replaceable battery pack and 24 V DC power supply unit), intrinsic safety variants for hazardous areas, robust IP66/IP67 housing for outdoor mounting, and seamless integration with Endress+Hauser Fieldgate gateways. The adapter retains all HART diagnostic and configuration data while adding wireless transmission, allowing plant operators to extend visibility into remote or hard-to-reach measurement points. Radio output is 10 dBm EIRP typical on the 2.4 GHz ISM band with mesh self-healing routing.

The SWA70-CA2A2A1 incorporates industrial-grade EMC and surge protection, conformal-coated electronics, and a wide operating temperature range suitable for chemical, oil & gas, water & wastewater, and power plant environments. Its internal mesh radio (IEEE 802.15.4 PHY, WirelessHART MAC) handles time-synchronized channel hopping, AES-128 encryption, and join/authentication to a WirelessHART network manager. Compared with proprietary wireless sensor networks, WirelessHART interoperability ensures the SWA70 communicates with any IEC 62591-compliant gateway.

Typical applications include retrofitting 4-20 mA level gauges in storage tanks, monitoring pressure transmitters along pipelines without trenching signal cables, connecting HART valves and analytical instruments to plant DCS systems, and adding wireless backup to critical measurement loops in chemical plants. Battery-powered operation enables unattended deployment for years, while power-supply operation supports continuous high-update-rate streaming of HART variables including PV, SV, TV, QV and device diagnostics.

Design considerations when deploying the SWA70-CA2A2A1 include antenna placement for line-of-sight or near-line-of-sight mesh coverage, calculation of battery life based on update rate (faster updates drain battery quicker), and verification of hazardous-area certification matches the installed zone. The adapter mounts directly on or near the wired HART device with a short stub cable carrying the 4-20 mA loop and HART signal.

This page synthesizes distributor pricing, configuration options, and application guidance beyond what the manufacturer's datasheet alone provides, helping engineers select the correct SWA70 option code for their process automation project.

Drop-in-Alternativen für SWA70-CA2A2A1 – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

SWA70-AA2A5A1

✅ Drop-In
📦 Field-mount enclosure (SWA70 family)
Different option-code configuration within same SWA70 family; identical WirelessHART adapter platform

📋 Referenzalternative (nicht im Katalog)

SWA70-CA2A2A1-Q1

✅ Drop-In ⚠️ Spezifikationen ungeprüft
📦 Field-mount enclosure (SWA70 family)
Same SWA70 base platform with extended/automotive-grade ordering suffix per E+H option code

📋 Referenzalternative (nicht im Katalog)

SWA70-BA1A2A1

✅ Drop-In ⚠️ Spezifikationen ungeprüft
📦 Field-mount enclosure (SWA70 family)
Same SWA70 family with alternative hazardous-area approval code and power-supply option

📋 Referenzalternative (nicht im Katalog)

Emerson 775 WirelessHART Adapter

✅ Drop-In
📦 Field-mount enclosure (WirelessHART adapter family)
Cross-brand WirelessHART adapter with same IEC 62591 protocol; mechanical mount differs

📋 Referenzalternative (nicht im Katalog)

Honeywell XYR 600A

✅ Drop-In
📦 Field-mount enclosure (WirelessHART adapter family)
Cross-brand WirelessHART adapter; same IEC 62591 mesh interoperability but different option codes

📋 Referenzalternative (nicht im Katalog)

SWA70-CA2A2A1 Spezifikationen (herstellerveröffentlicht)

Product Type WirelessHART Adapter (Add-on Interface Module)
Manufacturer Endress+Hauser
Series SWA70
Configured Option Code CA2A2A1
Funktion Wireless transmission of 4-20 mA and HART signals to a WirelessHART Fieldgate
Wireless Protocol WirelessHART (IEC 62591)
Radio Standard IEEE 802.15.4 (2.4 GHz ISM band)
Power Supply Options Battery pack or external power supply unit
Hazardous Area Certification Suitable for hazardous and non-hazardous areas (variant dependent)
Ingress Protection IP66/IP67 (typical for SWA70 family)
Encryption AES-128 (WirelessHART standard)
Network Topology Self-healing mesh, time-synchronized channel hopping
Compatibility Any IEC 62591-compliant WirelessHART gateway / Fieldgate
Operating Environment Process automation, chemical, oil & gas, water & wastewater, power
Mounting Field mount, wall or pipe (per installation guide)

SWA70-CA2A2A1 Schnittstellen & Anschlüsse

SWA70-CA2A2A1 bietet die folgenden, vom Hersteller veröffentlichten Schnittstellen und Anschlüsse: Funk. Pinbelegung der Erweiterungsheader, Nummerierung der Anschlüsse und elektrische Grenzwerte sind in der Herstellerdokumentation definiert.

Funk WirelessHART (IEC 62591)

Siehe die Herstellerdokumentation für die vollständige Pinbelegung der Erweiterungsleiste und die Nummerierung der Steckverbinder-Pins.

Typische Anwendungen

SWA70-CA2A2A1 ist geeignet für 6 Anwendungs: Wireless Tank Level Monitoring, Pipeline Pressure Transmitter Retrofit, Chemical Plant HART Valve Diagnostics, Water & Wastewater Treatment Monitoring, Power Plant Steam and Emissions Monitoring, Tank Farm and Terminal Inventory Automation.

🏭

Wireless Tank Level Monitoring

The SWA70-CA2A2A1 attaches to a wired 4-20 mA/HART level transmitter on a storage tank and wirelessly relays level readings to a WirelessHART Fieldgate. With IEC 62591 mesh networking, the SWA70 operates unattended on battery power for years, enabling tank-farm monitoring without trenching signal cables. Its IP66/IP67 housing tolerates outdoor weather and wash-down environments, and AES-128 encryption ensures measurement data integrity across the mesh.

⚡

Pipeline Pressure Transmitter Retrofit

Pipeline operators retrofit existing 4-20 mA/HART pressure transmitters with the SWA70-CA2A2A1 to add wireless monitoring along long right-of-way runs where cable trenching is impractical. The SWA70's 2.4 GHz IEEE 802.15.4 radio hops measurements across neighboring adapters via self-healing mesh, providing redundant communication paths. Battery or 24 V DC powering suits remote wellhead and compressor-station deployments in oil & gas fields.

🧩

Chemical Plant HART Valve Diagnostics

The SWA70-CA2A2A1 brings wireless HART diagnostics from smart valve positioners and analytical instruments into the plant DCS, eliminating manual walk-around data collection. Intrinsic-safety variants allow installation in Zone 1 hazardous areas common in chemical reactors. Each SWA70 streams PV, SV, TV, QV variables plus device diagnostics over WirelessHART, integrating with asset management software for predictive maintenance.

💧

Water & Wastewater Treatment Monitoring

Municipal water utilities deploy the SWA70-CA2A2A1 to add wireless connectivity to flow, pH, and turbidity meters in distributed well fields and lift stations. Battery-powered operation eliminates the need for utility power at remote sites, while mesh networking extends coverage across large treatment plant footprints. SWA70 IP66/IP67 protection handles outdoor and wet-environment installations typical of wastewater aeration basins.

⚡

Power Plant Steam and Emissions Monitoring

Power-generation operators use the SWA70-CA2A2A1 to retrofit steam flow, drum-level, and emissions analyzers onto wireless mesh networks, supporting condition-based maintenance and emissions compliance reporting. Wide operating temperature tolerance suits boiler-house environments. HART diagnostic data (device alert logs, calibration status) flows wirelessly to control rooms without dedicated signal cabling runs.

🏭

Tank Farm and Terminal Inventory Automation

Bulk-storage terminal operators attach the SWA70-CA2A2A1 to legacy 4-20 mA/HART level gauges to feed automated inventory management systems via WirelessHART. Each tank's level, temperature, and HART diagnostics stream through the mesh to the gateway, then into ERP systems for real-time volume reconciliation. Battery operation with multi-year life minimizes maintenance visits to remote tank farms.

Zusammenfassung der empfohlenen Produkte

Fieldgate SWG70 WirelessHART gateway / network manager Verwendet in: Wireless Tank Level Monitoring, Pipeline Pressure Transmitter Retrofit, Chemical Plant HART Valve Diagnostics, Water & Wastewater Treatment Monitoring, Power Plant Steam and Emissions Monitoring, Tank Farm and Terminal Inventory Automation Levelflex FMP56 HART level probe that pairs with adapter Verwendet in: Wireless Tank Level Monitoring Cerabar PMC51 HART pressure transmitter Verwendet in: Pipeline Pressure Transmitter Retrofit Liquiline CM442 HART analytical transmitter Verwendet in: Chemical Plant HART Valve Diagnostics Promag P300 HART flowmeter for water/wastewater Verwendet in: Water & Wastewater Treatment Monitoring Cerabar PMP71 HART pressure transmitter for steam lines Verwendet in: Power Plant Steam and Emissions Monitoring Micropilot FMR67 HART radar level gauge Verwendet in: Tank Farm and Terminal Inventory Automation
What is the SWA70-CA2A2A1 used for?
The SWA70-CA2A2A1 is an Endress+Hauser WirelessHART Adapter that wirelessly transmits 4-20 mA and HART signals from a connected wired field instrument to a WirelessHART Fieldgate gateway. According to the Endress+Hauser TI00026SEN datasheet, it serves as an add-on interface module for retrofitting legacy 4-20 mA/HART devices onto an IEC 62591 WirelessHART mesh network, eliminating the need to run new signal cabling.
What wireless protocol does the SWA70 use?
The SWA70 uses the WirelessHART protocol, standardized as IEC 62591, which runs on the IEEE 802.15.4 2.4 GHz ISM radio band. According to Endress+Hauser documentation, WirelessHART provides AES-128 encryption, time-synchronized channel hopping, and self-healing mesh networking to ensure reliable industrial wireless communication. The adapter interoperates with any compliant WirelessHART gateway.
How is the SWA70-CA2A2A1 powered?
The SWA70-CA2A2A1 can be powered by either a replaceable battery pack or an external power supply unit, giving it flexibility for remote or continuously-powered installations. The Endress+Hauser datasheet notes battery life depends on the configured update rate; lower update rates extend battery life to multi-year durations for remote monitoring applications without grid power.
Can the SWA70 be used in hazardous areas?
Yes, the SWA70 family includes variants approved for hazardous-area deployment. According to Endress+Hauser technical documentation, the SWA70 can be operated in both hazardous and non-hazardous areas depending on the selected option code and certification. Always verify the SWA70-CA2A2A1 option code matches the target hazardous zone (e.g., Zone 1/Zone 2) before installation.
What is the difference between the SWA70 and a WirelessHART field instrument?
The SWA70 is an add-on adapter that adds wireless capability to an existing wired 4-20 mA/HART device, whereas a WirelessHART field instrument has the radio built in natively. According to Endress+Hauser, the SWA70 is the right choice when you want to retrofit existing installed-base wired instruments onto a wireless mesh without replacing the primary measurement device.
How much does the SWA70-CA2A2A1 cost?
The Instrumart listing shows a configured SWA70 base price starting at $1,422.76 USD for the SWA70-AA2A5A1 configuration. Pricing varies by option codes (power supply, hazardous-area approval, antenna, cabling). All prices should be re-confirmed with Endress+Hauser or authorized distributors as of the current date, as configuration-dependent options can shift total cost.
Where can I buy the SWA70-CA2A2A1?
The SWA70-CA2A2A1 is available through Endress+Hauser authorized distributors including Instrumart, Kempston Controls, Eltra Trade, and direct from Endress+Hauser sales channels. Lead times for industrial wireless modules are typically 2-6 weeks depending on option-code availability. For urgent requirements, contact Endress+Hauser directly to confirm distributor stock and configuration compatibility.
What is the lead time for the SWA70-CA2A2A1?
Standard lead time for the SWA70-CA2A2A1 from Endress+Hauser authorized distributors is typically 2 to 6 weeks, depending on configuration options such as hazardous-area approval and antenna selection. Bulk orders may have longer lead times. For project-critical deployments, request a quotation directly from Endress+Hauser to lock in delivery scheduling before site installation.
Where can I download the SWA70 datasheet?
The official Endress+Hauser TI00026SEN WirelessHART Adapter SWA70 datasheet can be downloaded from the Endress+Hauser product portal at portal.endress.com (document reference TI00026SEN) or from distributors such as Instrumart. The datasheet contains detailed option-code configuration tables, hazardous-area approval matrix, antenna specifications, and battery life estimates for various update rates.
Is the SWA70 compatible with third-party WirelessHART gateways?
Yes, the SWA70 communicates using the open IEC 62591 WirelessHART standard, so it can join any compliant WirelessHART network managed by a third-party gateway or network manager. According to Endress+Hauser, the Fieldgate SWG70 is the native choice, but interoperability testing against Emerson, Honeywell, and ABB WirelessHART gateways is standard practice in mixed-vendor process plants.
What is the typical battery life of the SWA70?
According to the Endress+Hauser TI00026SEN datasheet, the SWA70 battery life depends on the configured update rate, radio path stability, and ambient temperature. Typical values are multi-year for update rates of 4 seconds or longer with a healthy mesh network. Faster update rates of 1 second or burst-mode streaming significantly reduce battery life and may require the external power supply option.
What is the radio range of the SWA70?
The SWA70 operates on the 2.4 GHz ISM band using IEEE 802.15.4 with line-of-sight range typically up to 250 m outdoors and shorter distances in obstructed industrial environments. According to WirelessHART standard documentation, mesh networking extends effective coverage across large plants because each SWA70 can act as a router for other adapters. Range is highly site-specific due to metallic obstructions.
How do I configure the SWA70-CA2A2A1 option codes?
The SWA70-CA2A2A1 option-code string encodes selections for power supply type, hazardous-area approval, antenna, cable glands, and country-specific radio certification. According to the Endress+Hauser product configurator, the first position typically selects power supply (battery vs. external PSU), subsequent positions select approvals and accessories. Use the Endress+Hauser online configurator to decode or re-configure the SWA70.
Can the SWA70 replace a Rosemount 775 WirelessHART gateway?
No, the SWA70 is a field adapter (end node), not a gateway. According to Endress+Hauser and Emerson documentation, the SWA70 attaches to a wired 4-20 mA/HART device and joins a WirelessHART network, while a gateway such as the Emerson 1420 or Endress+Hauser Fieldgate SWG70 manages the network. The SWA70 cannot act as a network manager; it requires a separate gateway for protocol conversion to host systems.
What WirelessHART alternative from another brand exists for the SWA70?
Cross-brand alternatives for the SWA70 family include the Emerson 775 WirelessHART Adapter, the Honeywell XYR 600A WirelessHART transmitter-adapter series, and the Pepperl+Fuchs WirelessHART adapter modules. According to IEC 62591 WirelessHART interoperability documentation, all WirelessHART adapters from any manufacturer interoperate on the same wireless mesh when joining a compliant network, but option codes and mechanical mounting differ.

Technische Referenzdaten für SWA70-CA2A2A1 – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the SWA70-CA2A2A1 when you need to retrofit wired 4-20 mA/HART field instruments onto a WirelessHART mesh in an Endress+Hauser-centric plant, especially where battery-powered remote monitoring, hazardous-area certification flexibility, and integration with Fieldgate SWG70 are priorities. Select the SWA70 base AA2A5A1 configuration when exact option codes differ but the same wireless adapter platform is required. Choose cross-brand alternatives (Emerson 775, Honeywell XYR 600A) only when the plant's existing WirelessHART network manager is non-E+H and option-code compatibility with that gateway is the deciding factor. For purely new deployments, evaluate native WirelessHART field instruments before adding adapters, since native wireless devices eliminate the adapter hardware layer and reduce failure points.

Vergleich mit Alternativen

Parameter Dieses Produkt SWA70-AA2A5A1 SWA70-CA2A2A1-Q1 SWA70-BA1A2A1 Emerson 775 WirelessHART Adapter Honeywell XYR 600A
Brand Endress+Hauser Endress+Hauser (same brand) Endress+Hauser (same brand) Endress+Hauser (same brand) Emerson (cross-brand) Honeywell (cross-brand)
Package Field-mount enclosure (SWA70 family) Field-mount enclosure (SWA70 family) - same Field-mount enclosure (SWA70 family) - same Field-mount enclosure (SWA70 family) - same Field-mount enclosure (WirelessHART adapter family) Field-mount enclosure (WirelessHART adapter family)
Wireless Protocol WirelessHART (IEC 62591) WirelessHART (IEC 62591) WirelessHART (IEC 62591) WirelessHART (IEC 62591) WirelessHART (IEC 62591) WirelessHART (IEC 62591)
Power Supply Battery pack or external PSU Battery pack or external PSU Battery pack or external PSU Battery pack or external PSU Battery or loop-powered (24V) Battery pack
Hazardous Area Approval Variant dependent (Zone 1/2 options) Variant dependent Variant dependent Variant dependent Class I Div 1/Zone 1 variants Class I Div 1/Zone 1 variants
Ingress Protection IP66/IP67 IP66/IP67 IP66/IP67 IP66/IP67 IP66 IP66/IP67
Interoperability Any IEC 62591 WirelessHART gateway Any IEC 62591 WirelessHART gateway Any IEC 62591 WirelessHART gateway Any IEC 62591 WirelessHART gateway Any IEC 62591 WirelessHART gateway Any IEC 62591 WirelessHART gateway

Wichtigste Unterscheidungsmerkmale

  • Native integration with Endress+Hauser Fieldgate ecosystem (vs. Emerson 775 WirelessHART Adapter)
  • Dual power-source flexibility (vs. Honeywell XYR 600A)
  • Wide global radio certification coverage (vs. Generic WirelessHART adapter modules)

Designhinweise

Confirm the SWA70-CA2A2A1 option-code string matches the target hazardous-area classification before ordering. Different position codes select non-IS, Ex i (intrinsically safe), or explosion-proof variants; selecting the wrong code can result in equipment that cannot be legally installed in Zone 1 areas. Cross-reference with the TI00026SEN datasheet approval matrix.

Place the SWA70 antenna with clear line-of-sight to neighboring WirelessHART nodes wherever possible. Metal obstructions (vessels, pipe racks, cable trays) attenuate the 2.4 GHz signal significantly. Mount the adapter vertically with the antenna pointing upward, and avoid mounting directly against large metal surfaces which create RF shadows. Plan mesh redundancy with at least two neighboring routers.

Battery life is dominated by the configured update rate. According to the Endress+Hauser datasheet, update rates of 1 second can reduce battery life to months, while 4-8 second rates typically yield multi-year operation. For continuous high-rate streaming, choose the external power supply option to avoid premature battery replacement. Calculate expected battery life using the E+H sizing tool before deployment.

Compliance-Informationen

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Bleifrei
Yes
Halogenfrei
Unknown
Konfliktmineralien
Unknown

Industrial wireless module designed for IEC 62591 WirelessHART compliance. RoHS and REACH compliance per Endress+Hauser product page; hazardous-area certification is variant-dependent and must be selected via the option-code string.

Daten verifiziert am: 2026-10-20 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

SWA70-CA2A2A1 datasheet Endress+Hauser SWA70 WirelessHART adapter SWA70-CA2A2A1 price WirelessHART adapter 4-20mA HART to wireless IEC 62591 wireless adapter industrial SWA70-CA2A2A1 hazardous area Zone 1 SWA70 vs Emerson 775 WirelessHART adapter buy WirelessHART adapter SWA70 online SWA70-CA2A2A1 pin configuration option codes retrofit 4-20mA HART transmitter to wireless SWA70-CA2A2A1 lead time distributor wireless HART adapter battery powered

Verwandte Bauteile & Begriffe

Endress+Hauser SWA70 SWA70-CA2A2A1 WirelessHART IEC 62591 HART protocol 4-20 mA IEEE 802.15.4 Fieldgate SWG70 AES-128 encryption IP66 IP67 RoHS REACH Zone 1 hazardous area Emerson 775 Honeywell XYR 600A Pepperl+Fuchs process automation intrinsic safety battery pack 2.4 GHz ISM band mesh network
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen