SY898533LKZ - 650 MHz 2:4 Clock Fanout Buffer | Microchip
Teilenummer: SY898533LKZ ✗ AbgekündigtSY898533LKZ Übersicht
A clock fanout buffer is a type of clock and timing IC within the broader semiconductor and digital logic hierarchy. It regenerates and distributes a reference clock to multiple downstream circuits while helping isolate the source from impedance changes and load variations. Compared with distributing a clock directly, a fanout buffer provides a controlled output stage for multiple loads and can reduce loading effects on the originating oscillator or clock source.
Key features of the SY898533LKZ include a 650 MHz maximum frequency, a 2:4 fanout configuration, 3.3 V LVPECL operation, and a 20-pin TSSOP package. The specified supply operating range is 3.135 V to 3.465 V. These characteristics place the device in applications requiring high-speed clock distribution, including communications equipment, data-conversion systems, servers, and other digital signal-processing platforms.
The SY898533LKZ belongs to Microchip Technology's high-performance clock-buffer product family. Its fanout function allows a single periodic signal to reach four destinations while preserving a consistent clock topology. The LVPECL interface supports integration with systems designed around high-speed differential clocking conventions, although input/output termination, biasing, impedance control, and trace geometry must be evaluated for the target circuit.
Typical applications include clock distribution for network-interface equipment, local clock generation for parallel data converters, fanout to multiple processors or FPGA clock inputs, and backplane or test-instrument clock distribution. The 650 MHz capability is particularly useful when several subsystems must be supplied from a common high-speed reference.
PCB implementation should prioritize short, impedance-controlled clock traces, solid reference planes, and symmetrical routing from the buffer outputs. Decoupling capacitance should be placed close to the supply and ground pins, while unused inputs and output states must be handled exactly as directed by the manufacturer datasheet.
This page combines lifecycle information, package details, verified distribution records, substitute-device research, application guidance, and design considerations to support component selection and PCB replacement planning. The SY898533LKZ is identified as an end-of-life catalog part, so designers should confirm availability and the suitability of any replacement before committing a new production design.
Drop-in-Alternativen für SY898533LKZ – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit SY898533LKZ (gleiche Bauform und Footprint) – abweichend in Package, Product Type, RoHS Status.
SY898535LKY
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →SY898533LKZ Technische Daten
| Product Type | Clock fanout buffer and distribution multiplexer |
| Maximale Taktfrequenz | 650 MHz |
| Fanout Configuration | 2:4 |
| Ausgangskonfiguration | 1:4 fanout |
| Logic Standard | 3.3 V LVPECL |
| Supply Voltage Range | 3.135 V to 3.465 V |
| Nominal Supply Voltage | 3.3 V |
| Gehäuse | 20-pin TSSOP |
| Package Width | 4.40 mm |
| Package Length | 0.173 inch |
| Montageart | Surface mount |
| Lead-Free Status | Lead free |
| RoHS-Status | RoHS compliant |
SY898533LKZ 0.173 inch Pinbelegungsleitfaden
Pinbelegung für SY898533LKZ (0.173 inch-Gehäuse). Pin-Nummerierung, Funktionen und Anschlussdiagramme sind im Herstellerdatenblatt definiert. Entnehmen Sie diesem den genauen Footprint und Lötrichtlinien.
Keine detaillierten Pinbelegungsdaten verfügbar für SY898533LKZ.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
SY898533LKZ ist geeignet für 6 Anwendungs: Network Interface Clock Distribution, FPGA Multi-Output Clocking, Parallel Data Converter Clocks, Communications Backplane Clocking, Server Processor Clock Trees, Industrial Test and Measurement Timing.
Network Interface Clock Distribution
The SY898533LKZ is appropriate for distributing a common communications reference clock among multiple high-speed logic sections. Its specified 650 MHz maximum frequency and four buffered outputs provide a practical way to feed several clock domains without loading the source directly. The implementation uses one input as the reference and routes four LVPECL outputs to receivers through controlled transmission lines. Because the catalog part is end of life, it is best suited to maintaining an existing network interface rather than starting a new platform design. The receiving circuits must accept 3.3 V LVPECL levels, and the PCB must preserve continuous return paths and controlled impedance.
Empfohlen
FPGA Multi-Output Clocking
The SY898533LKZ can distribute a high-speed clock to as many as four FPGA clock inputs when those inputs require compatible 3.3 V LVPECL signaling. Its 650 MHz specification gives it enough bandwidth for many communications and processing clock trees. Place the buffer close to the clock source, use equal-length routing where output-to-output skew matters, and preserve a continuous ground reference beneath every trace. Designers must verify the FPGA clock-input threshold, allowable input capacitance, and required clock-source jitter before finalizing the design. For new FPGA platforms, confirm current-product alternatives because the SY898533LKZ has reached end-of-life status.
Empfohlen
Parallel Data Converter Clocks
The SY898533LKZ fits parallel ADC and DAC clock trees that require one source timing signal to reach several converter or interface sections. With a 650 MHz maximum operating frequency and four buffered LVPECL outputs, it can provide matched clock distribution where edge alignment affects sampling performance. Each branch should have a controlled characteristic impedance and a continuous reference plane, while the total loading and termination strategy must be checked against the manufacturer's characteristicistics. The device is most appropriate for repair and continuation of established converter systems because its end-of-life designation creates sourcing risk for new designs.
Empfohlen
Communications Backplane Clocking
The SY898533LKZ can serve as a local fanout stage in communications equipment where a central reference must reach several line cards or clock-consuming circuits. Its 2:4 organization allows one incoming reference to feed four destinations, reducing repeated point-to-point loading of the upstream source. The 650 MHz rating supports high-speed digital clocking, but practical signal integrity depends on controlled trace geometry, correctly implemented LVPECL termination, and avoidance of stubs. Engineers should evaluate output-to-output skew and jitter for the specific topology and provide independent clocking or monitoring where redundancy is required.
Empfohlen
Server Processor Clock Trees
The SY898533LKZ can be evaluated for legacy server and processor clock trees that require a 3.3 V LVPECL reference distributed to several destination circuits. Its four outputs and 650 MHz maximum frequency make it suitable for branching a common clock within a controlled digital subsystem. The design should minimize trace length, maintain a solid reference plane, and account for receiver loading, clock jitter, and output skew. Because the part is end of life, use it primarily for product continuation, repair, or previously validated designs, and assess an active alternative before committing additional production volume.
Empfohlen
Industrial Test and Measurement Timing
The SY898533LKZ is suitable for distributing a fast reference clock in industrial test and measurement equipment that drives several acquisition, triggering, or conversion blocks. Its 650 MHz bandwidth and four buffered outputs allow common timing to be routed to multiple instrument sections. The clock network should use controlled impedance, short paths, and deliberate termination to limit reflections and preserve edge quality. Instrumentation designers must also consider trigger latency, deterministic output skew, and isolation between loads. Since the SY898533LKZ is end of life, new instruments should compare it with currently supported clock buffers instead of standardizing a newly launched product around an aging catalog part.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für SY898533LKZ – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | SY898535LKY |
|---|---|---|
| Package | 20-pin TSSOP | TSSOP-20 |
| Brand | Microchip Technology | Microchip Technology |
| Product Category | Clock fanout buffer and distribution multiplexer | Clock fanout buffer |
| Fanout Configuration | 2:4; also described as 1:4 fanout | 2:4 |
Wichtigste Unterscheidungsmerkmale
- Documented 650 MHz operating capability (vs. SY898535LKY)
- Explicit 2:4 clock distribution function (vs. SY898535LKY)
- Defined 3.3 V operating range (vs. SY898535LKY)
Designhinweise
Treat the four clock outputs as high-speed transmission lines rather than ordinary logic nets. Route them over a continuous ground plane, use the board stack-up's controlled-impedance geometry, avoid stubs and plane splits, and keep termination components close to the appropriate receiver or driver pins. Maintain comparable branch geometry where output-to-output skew is important. Confirm the exact input and output pin names in the manufacturer datasheet before releasing artwork because the public records do not provide a verified numbered pin map.
Keep the 3.3 V supply within the specified 3.135 V to 3.465 V range under worst-case loading and temperature. Place local bypass capacitance adjacent to the supply and ground pins, provide a low-impedance return path, and isolate noisy switching currents from the clock network. The 650 MHz operating capability does not remove the need for clean supply distribution because supply noise can affect edge timing and the quality of the regenerated LVPECL signals.
Verify LVPECL termination, biasing, receiver thresholds, source-to-load ratios, and unused-output states using the manufacturer datasheet before fabrication. Differential or single-ended LVPECL routing practice must follow the exact output architecture, and adding termination without understanding the device topology can reduce signal amplitude. Use scope measurements at the destination to check rise time, overshoot, ringing, and logic-level compliance after accounting for probe loading.
Do not substitute a device solely because it has a TSSOP-20 outline. A valid replacement also requires the same pin arrangement, supply range, fanout behavior, output-control logic, AC timing, and LVPECL interface. The SY898535LKY is the closest documented package-family candidate, but its exact specifications must be checked against the original datasheet. Also account for the end-of-life status of the SY898533LKZ when planning long-term production availability.
Compliance-Informationen
The product listing identifies SY898533LKZ as lead free and RoHS compliant. No verified REACH, halogen-free, conflict-minerals, or automotive-qualification statement is available for this catalog part.