THS788PFDT - 200MHz 4-Channel 8ps Timing IC | Texas Instruments
Teilenummer: THS788PFDT ✓ AktivTHS788PFDT Übersicht
A time measurement unit is a specialized timing IC that converts the arrival time of an event into a digital value relative to a synchronization reference. The THS788 places a time-to-digital converter inside each measurement channel, allowing timing information to be captured with picosecond-class resolution instead of relying on a general-purpose counter clock. Its hierarchy runs from time measurement unit to time-to-digital converter, then to application-specific clock and timing IC and semiconductor.
Key features include four measurement channels, 8 ps single-shot accuracy, 13 ps time-to-digital-converter resolution, and LVDS-compatible event inputs. The 200 MHz master clock determines the nominal TDC timing resolution, while a sync-channel input establishes time zero. According to the manufacturer product page, the device uses fast LVDS-compatible interfaces for its event inputs and supports calibrated timing calculations relative to the synchronization reference.
The device supports fast event capture through hit latches, which latch an event edge before the timing data is processed. This architecture is useful when several channels must respond to closely spaced signals and the relative delay between them must be measured reliably. The controller interface and external clock remain essential parts of the measurement system because synchronization, calibration, and digital result transfer determine the integrity of the captured timing data.
Typical applications include pulsed-laser range measurement, optical communication timing, radar and test instrumentation, high-speed trigger correlation, and industrial diagnostics that compare an event against a periodic reference. In such systems, the sync channel defines time zero, each event input records its relative arrival time, and the external controller applies calibration values before reporting the result.
A critical design consideration is preserving the integrity of the 200 MHz reference clock and the LVDS-compatible event signals. Route timing-sensitive inputs as controlled-impedance nets, keep the clock away from high-current switching nodes, and use the exposed-pad land pattern and thermal vias recommended in the package drawing. Differential timing measurements are only as accurate as the reference distribution and input return-loss behavior of the complete board.
This page consolidates the manufacturer timing specifications, package details, sourcing channels, and engineering guidance for the THS788PFDT, adding pin-connection and thermal-placement guidance that engineers would otherwise have to derive across multiple technical documents.
Drop-in-Alternativen für THS788PFDT – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit THS788PFDT (gleiche Bauform und Footprint) – abweichend in Package, Single-Shot Accuracy.
THS788PFD
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →SN26788PFD
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
THS788PFDT Technische Daten
| Device Type | Quad-Channel Time Measurement Unit (TMU) IC |
| Measurement Channels | 4 channels |
| Timing Architecture | Time-to-Digital Converter (TDC) |
| Single-Shot Accuracy | 8 ps |
| TDC Resolution | 13 ps LSB |
| External Controller Clock | 200 MHz |
| Synchronization | Sync-channel input defines time zero |
| Event Input Interface | Fast LVDS-compatible |
| Output Count | 1 output |
| Gehäuse | 100-HTQFP (14 x 14 mm) with exposed pad |
| Terminal Count | 100 terminals |
| Montageart | Surface mount |
| Package Shape | Square |
| Terminal Finish | Nickel Palladium Gold |
| Temperature Grade | Commercial |
| Maximum Operating Temperature | 70 °C |
| Nominal Supply Voltage | 3.3 V |
THS788PFDT square Pinbelegungsleitfaden
Pinbelegung für THS788PFDT (square-Gehäuse). Pin-Nummerierung, Funktionen und Anschlussdiagramme sind im Herstellerdatenblatt definiert. Entnehmen Sie diesem den genauen Footprint und Lötrichtlinien.
Keine detaillierten Pinbelegungsdaten verfügbar für THS788PFDT.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
THS788PFDT ist geeignet für 6 Anwendungs: Pulsed-Laser Range Measurement, Optical Communication Timing Analysis, Radar and Test-Instrumentation Timing, High-Speed Trigger Correlation, Industrial Pulse and Delay Diagnostics, Semiconductor Test and Timing Correlation.
Pulsed-Laser Range Measurement
The THS788PFDT fits time-of-flight ranging systems that compare a launch pulse with a reflected return event. Its four channels can capture a synchronization reference and several returned pulses, while the 8 ps single-shot accuracy and 13 ps TDC resolution provide the timing basis for precise distance estimation. Place the device between fast comparator or receiver outputs and the system controller, then apply measured calibration for cable, comparator, and optical delays. Because range resolution is directly proportional to time resolution, stable reference routing and clean LVDS-compatible event signals are as important as the nominal 13 ps TDC step.
Empfohlen
Optical Communication Timing Analysis
The THS788PFDT is suitable for measuring lane skew, transceiver path delay, and alignment errors in high-speed optical links. A sync pulse provides time zero, while separate event inputs capture the arrivals of related data or clock transitions through the fast LVDS-compatible interfaces. The 13 ps TDC resolution and 8 ps single-shot accuracy support fine delay analysis across four channels. In a laboratory or production test system, keep the inputs short and matched, provide a low-jitter 200 MHz controller clock, and calibrate channel-to-channel delay before converting captured intervals into skew results.
Empfohlen
Radar and Test-Instrumentation Timing
The THS788PFDT can serve as the timing-measurement core in radar, automated test equipment, and laboratory instruments that compare pulse arrivals with a periodic reference. Its four-channel TDC architecture captures closely related events without depending on the accuracy of a conventional digital counter clock. The sync channel establishes the common reference, and the 200 MHz controller clock derives the 13 ps TDC resolution. Practical implementations should account for fixed cable delays, trigger jitter, and propagation asymmetry through calibrated time offsets. The exposed-pad HTQFP package also requires a low-impedance ground plane and the recommended thermal-via pattern.
Empfohlen
High-Speed Trigger Correlation
The THS788PFDT is appropriate for correlating trigger signals across multiple acquisition channels, particularly when the intervals are too small to characterize reliably with general-purpose timers. Four event inputs can be evaluated against the sync reference, and the fast hit-latch path preserves arrival information before digital processing. The 8 ps single-shot accuracy supports fine alignment tasks, while the 13 ps TDC least-significant-bit defines the nominal conversion granularity. For production testers, use matched cables or controlled-impedance board routes and store per-channel calibration constants so connector and fixture delays do not dominate the measurement.
Empfohlen
Industrial Pulse and Delay Diagnostics
The THS788PFDT can measure small propagation delays in industrial control, ultrasonic systems, and event-driven machinery where multiple sensor outputs must be related to a common trigger. Four channels provide parallel measurement without requiring separate counters, and the sync input lets the controller distinguish sensor timing from controller clock timing. The 13 ps TDC resolution offers substantially finer measurement granularity than conventional millisecond or microsecond timers. Practical sensor signals should be conditioned into compatible levels before entering the TMU, and the 200 MHz clock distribution must remain isolated from relays, motor drives, and other switching sources to avoid adding timing uncertainty.
Empfohlen
Semiconductor Test and Timing Correlation
The THS788PFDT is useful in automated semiconductor test systems that need to compare propagation delay across several device paths or reference fixtures. The sync channel establishes time zero, and the external 200 MHz controller clock supports 13 ps TDC resolution with 8 ps single-shot accuracy. This allows a test controller to capture compact timing data instead of relying on oscilloscope-style continuous acquisition. For stable results, calibrate the fixture and cable delays, use a low-jitter clock source, and separate the timing network from high-current switching on the tester. The 100-terminal HTQFP footprint provides extensive interface and power connectivity but requires careful power-plane and exposed-pad design.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für THS788PFDT – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | THS788PFD | SN26788PFD |
|---|---|---|---|
| Package | 100-HTQFP (14 x 14 mm) | 100-HTQFP (14 x 14 mm) | 100-HTQFP (14 x 14 mm) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Device Type | Quad-Channel Time Measurement Unit | Quad-Channel Time Measurement Unit | Quad-Channel Time Measurement Unit |
| Measurement Channels | 4 channels | 4 channels | 4 channels |
| Single-Shot Accuracy | 8 ps | 8 ps | 8 ps |
| TDC Resolution | 13 ps LSB | 13 ps LSB | 13 ps LSB |
| External Controller Clock | 200 MHz | 200 MHz | 200 MHz |
| Event Input Interface | Fast LVDS-compatible | Fast LVDS-compatible | Fast LVDS-compatible |
| Output Count | 1 output | 1 output | 1 output |
| Temperature Grade | Commercial | Commercial | Commercial |
Wichtigste Unterscheidungsmerkmale
- Four-channel picosecond-class interval capture in one device (vs. THS788PFD)
- TDC resolution tied to a 200 MHz controller clock (vs. SN26788PFD)
- Specialized synchronization-based measurement rather than general timer counting (vs. THS788PFD)
Designhinweise
Treat the 200 MHz controller clock as a critical analog timing reference rather than an ordinary digital clock. Use the interface and termination guidance in the manufacturer datasheet, keep the clock route short, and isolate it from switching power stages and high-current digital edges. Apply channel calibration after installation because fixture, cable, and board-propagation delays can otherwise exceed the nominal 13 ps TDC least-significant-bit interval.
Route the LVDS-compatible event inputs as controlled-impedance nets with continuous return paths beneath the pair. Keep the sync input and measured event channels away from clocks that are intentionally asynchronous to the measurement, and avoid stubs or test-point discontinuities on timing-critical nets. Preserve channel symmetry because mismatched input delay contributes directly to channel-to-channel timing error.
The 100-terminal HTQFP includes an exposed pad that must follow the manufacturer land pattern for solder, paste, and thermal vias. Connect the pad to the ground plane as specified and avoid a thermal isolation slot beneath the device. A continuous ground reference also helps the high-speed interfaces; the same copper area supports heat spreading during repeated time-to-digital conversions.
Do not treat the sync input as another ordinary measurement channel. It establishes time zero, and each event result is calculated relative to that reference and then modified by the applicable calibration value. Also avoid assuming that 8 ps single-shot accuracy is an absolute board-level guarantee: calibration quality, clock jitter, input noise, and propagation differences all contribute to the final result.
Compliance-Informationen
Commercial temperature grade and nickel palladium gold terminal finish are identified. No specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declaration was identified in the available product records.