AS7030B-COLM vs AS7030B Comparación

Comparación detallada lado a lado de AS7030B-COLM por ams-OSRAM y AS7030B por ams-OSRAM. Compare las especificaciones clave, los parámetros eléctricos, el encapsulado, el estado del ciclo de vida, los precios y la disponibilidad para determinar el mejor componente para los requisitos de su diseño.

Comparación de especificaciones

Parámetro AS7030B-COLM AS7030B
Marca ams-OSRAM ams-OSRAM
Categoría Motion Sensors Motion Sensors
Estado del ciclo de vida Activo Activo
Estado del stock In Stock In Stock
Precio unitario (USD) $1,95 $4,65
Tipo de sensor Optical biosensor module with embedded ECG channel (PPG + ECG) —
Sensing Modalities Photoplethysmography (PPG) and electrocardiogram (ECG) —
Integrated Elements LEDs, photodetectors, analog front-end (AFE), sequencer —
Output Interface I2C —
I2C Slave Address 0x30 (7-bit); 0x60 write / 0x61 read (8-bit) —
Interrupt Output Yes (INT pin) —
ECG AFE Standard Meets IEC 60601-2-47 requirements (per manufacturer) —
Temperatura de funcionamiento -30C to +70C [DATA_NEEDED: operating temperature range]
Encapsulado OLGA22 —
Packaging Option Tape & Reel (T&R) —
Tipo de montaje Surface Mount Surface Mount
Typical Applications Fitness bands, smart watches, sports watches, smart patches Fitness bands, smart watches, sports watches, smart patches
Tensión de alimentación [DATA_NEEDED: supply voltage range] [DATA_NEEDED: supply voltage range]
Corriente de alimentación [DATA_NEEDED: typical supply current] [DATA_NEEDED: supply current]
LED Peak Wavelength [DATA_NEEDED: LED wavelength configuration] —
ADC Resolution [DATA_NEEDED: ADC resolution] [DATA_NEEDED: ADC resolution]
Estado RoHS Compliant (LF / lead-free ordering code) [DATA_NEEDED: RoHS status]
Product Type — Vital-sign biosensor module (PPG + ECG)
Measurement Functions — PPG (HRM/HRV/SpO2), ECG, GSR, skin temperature (via external NTC)
Communication Interface — I2C
Optical Elements — Integrated LEDs and photodiodes (multi-wavelength PPG) plus IR emitter with dedicated photodiode for proximity
Analog Front End — Low-noise ECG AFE with synchronous demodulator
Proximity Function — Yes (IR emitter + dedicated photodiode)
Ambient Light Rejection — Synchronous demodulation
PPG Sample Rate — [DATA_NEEDED: PPG sample rate]
ECG Channel Bandwidth — [DATA_NEEDED: ECG bandwidth]
Package / Ordering Code — AS7030B-COLM (module)
Evaluation Kits — AS7030B_EVALKIT_USB, AS7030B_EVALKIT_BT