AS7030B-COLM vs AS7030B Comparaison

Comparaison détaillée côte à côte de AS7030B-COLM par ams-OSRAM et AS7030B par ams-OSRAM. Comparez les spécifications clés, les paramètres électriques, le conditionnement, le statut de cycle de vie, les prix et la disponibilité pour déterminer le meilleur composant pour vos exigences de conception.

Comparaison des spécifications

Paramètre AS7030B-COLM AS7030B
Marque ams-OSRAM ams-OSRAM
Catégorie Motion Sensors Motion Sensors
Statut du cycle de vie Actif Actif
Statut du stock In Stock In Stock
Prix unitaire (USD) $1,95 $4,65
Type de capteur Optical biosensor module with embedded ECG channel (PPG + ECG) —
Sensing Modalities Photoplethysmography (PPG) and electrocardiogram (ECG) —
Integrated Elements LEDs, photodetectors, analog front-end (AFE), sequencer —
Output Interface I2C —
I2C Slave Address 0x30 (7-bit); 0x60 write / 0x61 read (8-bit) —
Interrupt Output Yes (INT pin) —
ECG AFE Standard Meets IEC 60601-2-47 requirements (per manufacturer) —
Température de fonctionnement -30C to +70C [DATA_NEEDED: operating temperature range]
Boîtier OLGA22 —
Packaging Option Tape & Reel (T&R) —
Type de montage Surface Mount Surface Mount
Typical Applications Fitness bands, smart watches, sports watches, smart patches Fitness bands, smart watches, sports watches, smart patches
Tension d'alimentation [DATA_NEEDED: supply voltage range] [DATA_NEEDED: supply voltage range]
Courant d'alimentation [DATA_NEEDED: typical supply current] [DATA_NEEDED: supply current]
LED Peak Wavelength [DATA_NEEDED: LED wavelength configuration] —
ADC Resolution [DATA_NEEDED: ADC resolution] [DATA_NEEDED: ADC resolution]
Statut RoHS Compliant (LF / lead-free ordering code) [DATA_NEEDED: RoHS status]
Product Type — Vital-sign biosensor module (PPG + ECG)
Measurement Functions — PPG (HRM/HRV/SpO2), ECG, GSR, skin temperature (via external NTC)
Communication Interface — I2C
Optical Elements — Integrated LEDs and photodiodes (multi-wavelength PPG) plus IR emitter with dedicated photodiode for proximity
Analog Front End — Low-noise ECG AFE with synchronous demodulator
Proximity Function — Yes (IR emitter + dedicated photodiode)
Ambient Light Rejection — Synchronous demodulation
PPG Sample Rate — [DATA_NEEDED: PPG sample rate]
ECG Channel Bandwidth — [DATA_NEEDED: ECG bandwidth]
Package / Ordering Code — AS7030B-COLM (module)
Evaluation Kits — AS7030B_EVALKIT_USB, AS7030B_EVALKIT_BT

Fiches techniques et ressources

Parcourir tous les produits Créer un BOM Demander un devis