AD585AQ/+ - 5 us Sample-and-Hold Amplifier | Analog Devices
N.º de pieza: AD585AQ/+ ✓ ActivoAD585AQ/+ Descripción general
A sample-and-hold amplifier is an analog signal-conditioning component that switches between acquisition and holding modes. During acquisition, the input signal passes through the input stage and charging network; during hold, the internal capacitor preserves the sampled voltage while the external circuit reads it. In the broader component hierarchy, the AD585 belongs to the amplifier family and specifically to the sample-and-hold amplifier subcategory used in data-acquisition, instrumentation, and control systems.
The principal benefits of the AD585 architecture are integrated acquisition circuitry, an internal holding capacitor, and matched resistors that simplify implementation. The differential HOLD control can operate with different logic families when an appropriate reference level is provided, while an on-chip TTL reference supports TTL-compatible control. These characteristics help reduce external component count and make acquisition timing more predictable in laboratory, industrial, and embedded analog systems.
The AD585 uses a signal path that separates fast acquisition from low-leakage voltage retention. Its FET input stage supports the high input impedance expected by sensor and measurement circuits, while the operational-amplifier section provides signal conditioning and drive for downstream circuitry. The monolithic implementation also keeps the holding capacitor and associated resistors thermally and physically close to the active circuitry, which is important when the sampled value must remain stable during conversion or processing.
Typical uses include rapid analog measurement before an ADC, peak-and-hold style acquisition, synchronized data logging, industrial process monitoring, and precision test equipment. The differential HOLD input is particularly useful when the system controller controls acquisition timing. Because the package is a through-hole 14-pin CERDIP, the part is also appropriate for legacy instrumentation, educational systems, and maintenance designs where a sealed ceramic package and straightforward prototyping are priorities.
Designers should follow the manufacturer datasheet for the exact pin assignments, timing definitions, acquisition accuracy, input range, output drive, hold leakage, and recommended bypass connections. Pay particular attention to settling time and droop during hold because system accuracy can be limited by capacitor leakage, switch behavior, switch leakage, source impedance, and the timing of the HOLD signal. Confirm that the required logic thresholds and voltage references match the surrounding control system before finalizing the circuit.
This page organizes the AD585AQ/+ architecture, package information, sourcing details, practical applications, and verified drop-in options into an engineering-focused reference. It also provides design guidance that helps distinguish a genuine pin-compatible replacement from a merely similar sample-and-hold function, supporting faster component selection without changing the original PCB footprint.
Alternativas directas para AD585AQ/+ — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
AD585SQ
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
AD585JQ
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
AD585AQ
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
AD585AQ/+ Valores máximos y características eléctricas
| Product Type | Monolithic sample-and-hold amplifier |
| Number of Circuits | 1 circuit |
| Acquisition Time | 5 us |
| Encapsulado | 14-pin CERDIP |
| Recuento de pines | 14 pins |
| Architecture | Operational amplifier, ultralow-leakage analog switch, and FET input integrating amplifier |
| Holding Capacitor | Internal |
| Application Resistors | Internal and matched |
| Hold Control | Differential HOLD input |
| TTL Reference | On-chip TTL reference level |
| Input Stage | FET input integrating amplifier |
| Tipo de montaje | Through-hole |
Guía de configuración de pines de AD585AQ/+ 14-pin cerdip
Configuración de pines para AD585AQ/+ (encapsulado 14-pin cerdip). Este componente analógico presenta pines de entrada, salida y alimentación. Consulte la hoja de datos del fabricante para conocer las configuraciones de los pines de ajuste de offset, compensación y habilitación. Ideal para circuitos de acondicionamiento de señal y amplificadores.
No hay datos detallados de patillaje disponibles para AD585AQ/+.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
AD585AQ/+ es adecuado para 6 aplicacións: Rapid Analog Data Acquisition, Precision Test and Measurement, Industrial Process Monitoring, Sensor Signal Conditioning, Synchronized Control Systems, Peak and Transient Capture.
Rapid Analog Data Acquisition
The AD585AQ/+ is suited to acquiring an analog measurement before conversion when the system must capture the signal in approximately 5 us. The sample-and-hold amplifier places the input into acquisition mode, charges the internal holding capacitor through the matched application network, and then retains the voltage while the HOLD control is asserted. This architecture can reduce the accuracy burden on a downstream ADC by presenting a stable held value during conversion. For a new design, verify input range, acquisition settling, output drive, supply voltage, and logic thresholds against the manufacturer datasheet before fixing the signal-conditioning bandwidth.
Recomendado
Precision Test and Measurement
In precision test equipment, the AD585AQ/+ can capture a changing analog response and hold it for subsequent measurement, comparison, or digital processing. Its 5 us acquisition interval makes it relevant to controlled stimulus-and-response systems in which the sampled value must correspond closely to a defined trigger point. The integrated operational amplifier, FET input integrating amplifier, holding capacitor, and matched resistors reduce the number of discrete elements around the acquisition node. Designers should budget for settling time, hold leakage, source impedance, and the propagation delay of the differential HOLD command when calculating overall measurement uncertainty.
Recomendado
Industrial Process Monitoring
The AD585AQ/+ can serve as the acquisition stage in an industrial monitoring system that samples pressure, temperature, position, or other slowly changing analog signals before digitization. A stable held voltage can simplify the input requirements of the subsequent converter and provide a defined sampling interval tied to the HOLD control. The 14-pin CERDIP package is particularly compatible with legacy through-hole instrumentation. For deployed equipment, verify the manufacturer's operating-temperature limits, supply requirements, leakage behavior, and external component recommendations so the acquisition accuracy remains suitable for the process-control target.
Recomendado
Sensor Signal Conditioning
The AD585AQ/+ can acquire signals from high-impedance sensors by using the integrated FET input integrating amplifier as the front end of a sample-and-hold stage. This is useful when a sensor output must be sampled at a controlled instant and then maintained for amplification, conversion, or alarm evaluation. The 5 us acquisition specification defines the nominal timing target, but practical accuracy also depends on source resistance, sensor settling, leakage, and the voltage range accepted by the device. Use the manufacturer input-capacitance and acquisition recommendations to select the external network and avoid overdriving the input during the hold interval.
Recomendado
Synchronized Control Systems
The AD585AQ/+ is applicable to synchronized control and data-logging circuits where an analog variable must be captured at a system-defined event. The differential HOLD input allows acquisition timing to be coordinated by external logic, while the on-chip TTL reference supports compatible TTL control levels. Once held, the output can remain available for a controller, comparator, or ADC during the next processing interval. Timing design should include propagation delay, acquisition aperture, conversion time, and any droop caused by switch and capacitor leakage to ensure the stored value represents the intended sample interval.
Recomendado
Peak and Transient Capture
The AD585AQ/+ can be evaluated for peak-and-hold and transient-capture systems because it separates the acquisition interval from the subsequent hold interval using an analog switch and internal capacitor. The 5 us acquisition time provides a defined window for capturing a rapidly changing waveform event, while the hold stage isolates that value for slower measurement or conversion. The main design constraints are acquisition bandwidth, droop during hold, switch leakage, output loading, and the settling behavior of the connected source. Confirm these limits in the manufacturer datasheet and model the complete timing budget before using the part for waveforms beyond the specified acquisition envelope.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para AD585AQ/+ — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | AD585SQ | AD585JQ | AD585AQ |
|---|---|---|---|---|
| Package | 14-pin CERDIP | 14-pin CERDIP | 14-pin CERDIP | 14-pin CERDIP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Product Type | Monolithic sample-and-hold amplifier | Monolithic sample-and-hold amplifier | Monolithic sample-and-hold amplifier | Monolithic sample-and-hold amplifier |
| Number of Circuits | 1 circuit | 1 circuit | 1 circuit | 1 circuit |
| Acquisition Time | 5 us | 5 us | 5 us | 5 us |
| Signal Path | Operational amplifier, ultralow-leakage analog switch, and FET input integrating amplifier | Operational amplifier, ultralow-leakage analog switch, and FET input integrating amplifier | Operational amplifier, ultralow-leakage analog switch, and FET input integrating amplifier | Operational amplifier, ultralow-leakage analog switch, and FET input integrating amplifier |
| Holding Capacitor | Internal | Internal | Internal | Internal |
| Hold Control | Differential HOLD input | Differential HOLD input | Differential HOLD input | Differential HOLD input |
| TTL Reference | On-chip TTL reference level | On-chip TTL reference level | On-chip TTL reference level | On-chip TTL reference level |
| Mounting Type | Through-hole | Through-hole | Through-hole | Through-hole |
Diferenciadores clave
- Integrated acquisition and holding elements reduce external circuitry (frente a AD585SQ)
- Differential HOLD control supports coordinated acquisition timing (frente a AD585JQ)
- Exact 14-pin CERDIP ordering configuration (frente a AD585AQ)
Notas de diseño
Do not treat any AD585 family ordering code as interchangeable without checking its package drawing and performance grade. AD585AQ/+ and AD585AQ share the 14-pin CERDIP configuration, while grade-coded variants can change accuracy or temperature limits. Confirm the HOLD polarity, logic reference, supply arrangement, analog input range, and output connection against the manufacturer pin-description table before updating an existing PCB.
Treat the acquisition interval as a complete settling budget rather than assuming that 5 us alone guarantees full measurement accuracy. Include source impedance, sensor or driver settling, acquisition-network capacitance, control propagation delay, and the definition of the acquisition aperture. During hold, include capacitor droop, switch leakage, input bias effects, and output loading when estimating how much the sampled voltage can change before conversion.
Use the manufacturer reference layout and pin table for the 14-pin CERDIP footprint. Keep analog input and output routing away from digital HOLD and clock lines, place the required bypass components at their specified pins, and provide a low-impedance ground return. Because sample-and-hold accuracy depends on leakage and switching behavior, avoid long PCB leakage paths near the held node and use guarding techniques where the operating environment creates significant board contamination or humidity.
Check the AD585 supply limits and output-stage operating region in the manufacturer datasheet before enabling acquisition. The input, output, HOLD logic, and TTL reference must remain inside their respective voltage limits during startup and normal transitions. For systems with multiple rails, define a sequence that keeps the analog section, logic controls, and downstream converter in valid states; an unstable reference or partially powered output can corrupt the retained sample.
Información de cumplimiento
Compliance status must be confirmed for the exact AD585AQ/+ ordering code using the manufacturer's current product documentation. The slash-plus ordering mark should not be interpreted as a substitute for a formal RoHS declaration.