Analog Devices

AD620ARZ - Low Cost Low Power Instrumentation Amplifier | Analog Devices

N.º de pieza: AD620ARZ ✓ Activo
En stock Se envía en 1-3 días hábiles
±2.3 V to ±18 V Vdss 1.3 mA Id 8-SOIC (0.154", 3.90mm Width) Package
Desde $7.2 USD / unidad
MOQ: 1 |
Precio actualizado: 2026-08-21
Precios por volumen
Cant. Precio unitario Total
1 $11.44 $11,44
10 $10.3 $103,00
100 $9.15 $915,00
500 $8 $4.000,00
1.000 $7.2 $7.200,00
ℹ️ Todos los precios están en USD

AD620ARZ Descripción general

The AD620ARZ is a low cost, high accuracy instrumentation amplifier from Analog Devices, designed for applications requiring precise amplification of small differential signals in the presence of common-mode noise. It is available in an 8-lead SOIC package and operates from a single or dual supply ranging from ±2.3V to ±18V. The gain is set by a single external resistor, allowing gains from 1 to 10,000, making it highly versatile for various sensor interface applications.

An instrumentation amplifier is a type of differential amplifier that amplifies the difference between two input signals while rejecting common-mode voltages. It is characterized by high input impedance, high common-mode rejection ratio (CMRR), and low offset voltage, making it ideal for precision measurement systems. The AD620 belongs to the family of instrumentation amplifiers, which are essential building blocks in analog signal conditioning chains, often used after sensors such as strain gauges, thermocouples, and pressure sensors.

Key features of the AD620ARZ include a maximum supply current of 1.3 mA, making it suitable for battery-powered and portable applications. It offers a CMRR of 100 dB at gain of 10, and a low input offset voltage of 50 µV. The device also features low input bias current of 1.0 nA, and a bandwidth of 120 kHz at gain of 10. The AD620ARZ is specified over the industrial temperature range of -40°C to +85°C.

Technically, the AD620 uses a classic three-op-amp topology with an internal precision resistor network, achieving excellent gain accuracy and stability. The gain is set by an external resistor RG, with the formula G = 1 + 49.4 kΩ/RG. This architecture provides high input impedance (10 GΩ) and low noise, with a voltage noise density of 9 nV/√Hz at 1 kHz. The device is laser-trimmed for low offset voltage and drift, ensuring high precision over temperature.

Typical applications include medical instrumentation (ECG, EEG), industrial process control, transducer interfaces, and data acquisition systems. The AD620ARZ is particularly suited for applications where low power consumption and high accuracy are critical, such as portable medical devices and remote sensor nodes.

When designing with the AD620ARZ, it is important to provide proper decoupling on the power supply pins and to keep the input traces short and shielded to minimize noise pickup. The gain resistor should be placed close to the device to reduce parasitic capacitance and maintain accuracy.

Alternativas directas para AD620ARZ — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Variantes de esta serie

Modelos de la misma serie compatibles directamente con AD620ARZ (mismo factor de forma y huella) — difiere en Gain Range, Package, Quiescent Current, Operating Temperature Range, Input Bias Current.

Analog Devices
Gain Range: 1 to 1000+
Package: 8-SOIC (0.154 in, 3.90 mm width)
Comparar con AD620ARZ →
Analog Devices
Gain Range: 1 to 1000
Package: 8-SOIC
Quiescent Current: 1.2 mA
Comparar con AD620ARZ →
Analog Devices
Gain Range: 1 to 1000 (set by 1 external resistor)
Quiescent Current: 350 µA typical
Operating Temperature Range: -40°C to +125°C
Comparar con AD620ARZ →
Analog Devices
Gain Range: 5 to 1000
Package: 8-SOIC
Operating Temperature Range: -40°C to +125°C
Comparar con AD620ARZ →
Analog Devices
Gain Range: 5 to 1000 (set by one external resistor)
Package: 8-SOIC (SOIC-8)
Comparar con AD620ARZ →
Analog Devices
Gain Range: 5 to 1000 (set by one external resistor)
Quiescent Current: 700 µA
Operating Temperature Range: -40°C to +125°C
Comparar con AD620ARZ →
Analog Devices
Gain Range: 1 to 10000
Package: 8-Lead SOIC
Quiescent Current: 2.3 mA typ
Comparar con AD620ARZ →
Analog Devices
Package: 8-SOIC
Operating Temperature Range: -40°C to +125°C
Comparar con AD620ARZ →
Texas Instruments
Gain Range: 1 V/V to 10000 V/V, set by single external resistor
Package: 8-SOIC (0.154 in, 3.90 mm Width)
Operating Temperature Range: -40C to +85C
Comparar con AD620ARZ →
Texas Instruments
Gain Range: 1 V/V to 10000 V/V (single resistor set)
Package: 8-SOIC (D)
Quiescent Current: 350 uA

Herramienta de comparación rápida — seleccione piezas alternativas para compararlas lado a lado:

AD620BRZ

✅ Sustitución directa
📦 8-SOIC
Higher accuracy grade, lower offset voltage (25 µV max)

📋 Alternativa de referencia (no en el catálogo)

AD620AR

✅ Sustitución directa
📦 8-SOIC
Same die, different packaging (tube vs reel)

📋 Alternativa de referencia (no en el catálogo)

INA128UA

✅ Sustitución directa ⚠️ Especificaciones sin verificar
📦 8-SOIC
Cross-brand, similar specs, pin-compatible SOIC

📋 Alternativa de referencia (no en el catálogo)

TPA1286-SO1R

✅ Sustitución directa
📦 8-SOIC
Domestic alternative, pin-compatible, lower cost

📋 Alternativa de referencia (no en el catálogo)

ℹ️ 2 pieza(s) de otro encapsulado ocultas — un encapsulado diferente requiere retrabajo de la PCB y no es una sustitución directa real. Contáctenos si necesita sugerencias de otros encapsulados.

AD620ARZ Valores máximos y características eléctricas

Amplifier Type Instrumentation Amplifier
Number of Circuits 1
Gain Range 1 to 10,000
Supply Voltage Range ±2.3 V to ±18 V
Supply Current (Max) 1.3 mA
CMRR at Gain 10 100 dB
Input Offset Voltage 50 µV
Input Bias Current 1.0 nA
Bandwidth at Gain 10 120 kHz
Voltage Noise Density at 1 kHz 9 nV/√Hz
Input Impedance 10 GΩ
Rango de temperatura de funcionamiento -40°C to +85°C
Encapsulado 8-SOIC (0.154", 3.90mm Width)
Tipo de montaje Surface Mount
Estado RoHS Compliant

Configuración de pines de AD620ARZ

SOP-8 Package Pinout Diagram SOP-8 8-pin small outline, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOP-8
Pin 1 RG — Gain setting resistor connection
Pin 2 -IN — Inverting input
Pin 3 +IN — Non-inverting input
Pin 4 V- — Negative supply
Pin 5 REF — Reference voltage
Pin 6 OUT — Output
Pin 7 V+ — Positive supply
Pin 8 RG — Gain setting resistor connection

Aplicaciones típicas

AD620ARZ es adecuado para 6 aplicacións: Medical Instrumentation (ECG/EEG), Industrial Process Control, Data Acquisition Systems, Transducer Interfaces, Portable Medical Devices, Weigh Scales and Load Cells.

💊

Medical Instrumentation (ECG/EEG)

The AD620ARZ is ideal for ECG and EEG systems due to its low noise (9 nV/√Hz) and high CMRR (100 dB at gain 10). It amplifies tiny bioelectric signals while rejecting common-mode interference from the body and power lines. Its low supply current (1.3 mA) supports battery-operated portable monitors. The gain set by one resistor simplifies channel calibration. For multi-channel systems, multiple AD620ARZ can be used with a multiplexed ADC. The device's high input impedance (10 GΩ) prevents loading of electrode signals. Its small SOIC package enables compact PCB layouts in wearable devices.

🏭

Industrial Process Control

In industrial settings, the AD620ARZ conditions signals from sensors like pressure transducers and thermocouples. Its wide supply range (±2.3V to ±18V) accommodates 24V industrial rails. The high CMRR rejects noise from motors and power lines. The gain resistor allows precise scaling of sensor outputs to match ADC input ranges. The device's industrial temperature range (-40°C to +85°C) ensures reliable operation in harsh environments. Its low drift maintains accuracy over temperature. The SOIC package is compatible with automated assembly for high-volume production.

🖥️

Data Acquisition Systems

The AD620ARZ is a front-end amplifier in data acquisition systems, providing gain and common-mode rejection before ADC conversion. Its low noise and high input impedance preserve signal integrity. The gain set by one resistor allows flexible scaling for various sensor types. The device's bandwidth of 120 kHz at gain 10 supports moderate-speed sampling. Its low power consumption is beneficial for multi-channel systems. The SOIC package allows dense board layouts. The AD620ARZ is often paired with high-resolution ADCs to achieve system accuracy.

🔧

Transducer Interfaces

The AD620ARZ interfaces with various transducers, including strain gauges, load cells, and pressure sensors. Its high input impedance (10 GΩ) minimizes loading on bridge circuits. The low offset voltage (50 µV) reduces measurement error. The gain resistor allows precise calibration of full-scale output. The device's low noise ensures accurate detection of small signal changes. Its wide supply range supports both battery and line-powered systems. The SOIC package is suitable for compact sensor modules. The AD620ARZ's low power is ideal for remote sensors.

📱

Portable Medical Devices

The AD620ARZ is well-suited for portable medical devices like wearable heart rate monitors and glucose meters. Its low supply current (1.3 mA) extends battery life. The device operates from low supply voltages (±2.3V), compatible with 3V batteries. Its small SOIC package enables miniaturized designs. The high CMRR reduces interference from motion artifacts. The low noise ensures reliable signal detection. The gain set by one resistor simplifies design. The industrial temperature range covers body-worn applications.

⚖️

Weigh Scales and Load Cells

The AD620ARZ amplifies the small differential output of load cells in weigh scales. Its low offset voltage and drift ensure accurate weight measurements. The gain resistor sets the sensitivity to match the load cell's full-scale output. The high CMRR rejects common-mode noise from the bridge supply. The device's low noise improves resolution. Its wide supply range supports various power architectures. The SOIC package is suitable for compact scale electronics. The AD620ARZ's low power is beneficial for battery-operated scales.

What is the AD620ARZ?
The AD620ARZ is a low cost, high accuracy instrumentation amplifier from Analog Devices. It amplifies small differential signals while rejecting common-mode noise, with a gain set by a single external resistor from 1 to 10,000. It operates from ±2.3V to ±18V supplies and is available in an 8-lead SOIC package.
What is the supply voltage range of AD620ARZ?
The AD620ARZ operates from a single or dual supply ranging from ±2.3V to ±18V. This wide range allows use in both battery-powered and industrial applications. According to the Analog Devices AD620 datasheet, the device is specified over the industrial temperature range of -40°C to +85°C.
How do I set the gain of AD620ARZ?
The gain of the AD620ARZ is set by a single external resistor RG connected between pins 1 and 8. The gain formula is G = 1 + 49.4 kΩ/RG. For example, to achieve a gain of 100, use RG = 499 Ω. This simplicity makes the AD620ARZ easy to configure for various applications.
What is the CMRR of AD620ARZ?
The AD620ARZ has a common-mode rejection ratio (CMRR) of 100 dB at a gain of 10. This high CMRR ensures that common-mode noise, such as 50/60 Hz interference, is effectively rejected, making it ideal for precision measurement systems where signal integrity is critical.
What is the input offset voltage of AD620ARZ?
The AD620ARZ has a low input offset voltage of 50 µV. This low offset, combined with laser trimming, ensures high DC accuracy over temperature. This makes the device suitable for precision applications like strain gauge and thermocouple amplification where offset errors must be minimized.
What is the bandwidth of AD620ARZ?
The AD620ARZ has a bandwidth of 120 kHz at a gain of 10. This bandwidth is sufficient for many sensor and data acquisition applications, including ECG and industrial process control. For higher gains, the bandwidth decreases, so consider the gain-bandwidth trade-off for your specific application.
What is the supply current of AD620ARZ?
The AD620ARZ has a maximum supply current of 1.3 mA. This low power consumption makes it ideal for battery-powered and portable applications, such as remote sensor nodes and wearable medical devices. The low quiescent current extends battery life while maintaining high performance.
What is the input bias current of AD620ARZ?
The AD620ARZ has a low input bias current of 1.0 nA. This low bias current minimizes errors when interfacing with high-impedance sources, such as pH sensors and photodiodes. It ensures that the input signal is not loaded, preserving measurement accuracy.
What is the voltage noise density of AD620ARZ?
The AD620ARZ has a voltage noise density of 9 nV/√Hz at 1 kHz. This low noise performance is essential for applications requiring high signal-to-noise ratio, such as medical instrumentation and precision data acquisition. It allows the amplification of small signals without significant noise degradation.
What is the package of AD620ARZ?
The AD620ARZ is available in an 8-lead SOIC package (0.154", 3.90mm Width). This surface-mount package is compact and suitable for automated assembly. The small footprint is ideal for space-constrained designs, and the SOIC package is widely used in industrial and consumer electronics.
Is AD620ARZ RoHS compliant?
Yes, the AD620ARZ is RoHS compliant. This means it meets the European Union's Restriction of Hazardous Substances directive, which limits the use of certain hazardous materials in electrical and electronic equipment. This compliance ensures the component is suitable for use in products sold in the EU and other regions with similar regulations.
What are the typical applications of AD620ARZ?
The AD620ARZ is commonly used in medical instrumentation (ECG, EEG), industrial process control, transducer interfaces, and data acquisition systems. Its low power consumption and high accuracy make it suitable for portable medical devices and remote sensor nodes. It is also used in weigh scales and pressure measurement systems.
What is the difference between AD620ARZ and AD620BRZ?
The AD620ARZ and AD620BRZ are both instrumentation amplifiers from Analog Devices, but they differ in accuracy grades. The AD620BRZ has a lower input offset voltage (25 µV max) and lower gain error compared to the AD620ARZ (50 µV max). For higher precision applications, the AD620BRZ is preferred, while the AD620ARZ offers a cost-effective solution for less demanding requirements.
Can AD620ARZ be used in battery-powered devices?
Yes, the AD620ARZ is well-suited for battery-powered devices due to its low supply current of 1.3 mA. It operates from supplies as low as ±2.3V, making it compatible with 3V battery systems. Its low power consumption extends battery life, making it ideal for portable medical devices and remote sensors.
Where can I buy AD620ARZ?
The AD620ARZ is available from major distributors such as DigiKey, Mouser, and Octopart. As of 2026-08-22, the unit price is approximately $11.44. Stock levels vary, so check distributor websites for current availability and lead times. You can also purchase directly from Analog Devices or authorized distributors.

Datos de referencia de ingeniería para AD620ARZ — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose the AD620ARZ when you need a low-cost, low-power instrumentation amplifier with good accuracy for general-purpose applications. It is ideal for battery-powered devices, portable medical equipment, and industrial sensor interfaces. If you require higher precision (lower offset voltage), consider the AD620BRZ. For lower power consumption, the INA128UA from Texas Instruments is a suitable alternative, but verify pin compatibility. For cost-sensitive designs, the TPA1286-SO1R from 3PEAK offers a domestic alternative with similar performance. Always verify pinout and specifications before substitution.

Comparación con alternativas

Parámetro Este producto AD620BRZ INA128UA TPA1286-SO1R
Package 8-SOIC 8-SOIC 8-SOIC 8-SOIC
Brand Analog Devices Analog Devices Texas Instruments 3PEAK

Diferenciadores clave

  • Low supply current of 1.3 mA (frente a INA128UA)
  • High CMRR of 100 dB at gain 10 (frente a INA128UA)
  • Lower cost compared to AD620BRZ (frente a AD620BRZ)

Notas de diseño

Place decoupling capacitors (0.1 µF) close to the V+ and V- pins to minimize power supply noise. Use a ground plane to reduce noise pickup. Keep input traces short and shielded to minimize interference. The gain resistor RG should be placed close to pins 1 and 8 to reduce parasitic capacitance and maintain accuracy.

Ensure the gain resistor RG is a precision resistor (1% or better) to maintain gain accuracy. Avoid running high-frequency digital traces near the input pins to prevent noise coupling. The reference pin (REF) should be bypassed with a capacitor to ground to reduce noise. Do not exceed the absolute maximum supply voltage of ±18V.

The AD620ARZ dissipates minimal power due to its low supply current (1.3 mA). At maximum supply voltage (±18V), power dissipation is approximately 47 mW, which is well within the SOIC package's thermal limits. No external heatsinking is required. Ensure adequate copper area for heat dissipation in high-temperature environments.

Información de cumplimiento

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
Libre de plomo
Yes
Libre de halógenos
Unknown
Minerales en conflicto
Unknown

RoHS compliant per distributor data. Other compliance information not specified in provided data.

Datos verificados el: 2026-08-22 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

AD620ARZ datasheet AD620ARZ price AD620ARZ buy AD620ARZ equivalent AD620ARZ vs AD620BRZ AD620ARZ instrumentation amplifier AD620ARZ SOIC-8 AD620ARZ ECG application AD620ARZ pinout AD620ARZ in stock

Componentes & términos relacionados

Analog Devices AD620ARZ AD620BRZ INA128UA TPA1286-SO1R Instrumentation Amplifier Differential Amplifier CMRR SOIC-8 RoHS ECG EEG Data Acquisition Transducer Low Power
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
Total: $0.00 USD
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ