AD844ANZ - 60 MHz, 2000 V/us Current Feedback Amp | Analog Devices
N.º de pieza: AD844ANZ ✓ ActivoAD844ANZ Descripción general
A current-feedback operational amplifier is a voltage-feedback amplifier subclass that uses a closed-loop transfer function dependent on closed-loop bandwidth rather than open-loop gain. It belongs to the operational amplifier, analog amplifier, and signal-conditioning IC hierarchies. Unlike a conventional voltage-feedback amplifier, the AD844 maintains useful bandwidth over a broad gain range and can drive low-resistance loads while preserving rapid large-signal response.
The AD844ANZ provides 60 MHz bandwidth at a gain of -1 and 33 MHz at a gain of -10. Its 2000 V/us slew rate supports full-power operation at 20 MHz with 20 V peak-to-peak output into a 500 ohm load. The amplifier settles to 0.1% within 100 ns for a 10 V step, making it useful in waveform generation, video, communications, and instrumentation circuits that require rapid transitions.
The device uses Analog Devices' junction-isolated complementary bipolar process. Differential gain error is 0.03% at 4.4 MHz, differential phase error is 0.16 degrees at 4.4 MHz, and maximum offset voltage is 150 uV for the B grade. Its low quiescent current of 6.5 mA helps limit power consumption while retaining high slew capability.
Typical uses include active filters, video amplification, pulse shaping, current-feedback ADC interfaces, laboratory test equipment, and high-speed instrumentation. The current-feedback architecture is particularly valuable when the application needs a closed-loop gain that changes without the severe bandwidth reduction associated with some conventional voltage-feedback amplifiers.
When laying out an AD844ANZ circuit, follow the pin-connection and feedback guidance in the manufacturer datasheet. Keep feedback-loop components close to the device, account for parasitic capacitance in high-gain layouts, and verify stability with the intended source and load impedances. The 8-pin DIP footprint also allows straightforward prototyping and replacement in laboratory equipment.
Alternativas directas para AD844ANZ — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
Variantes de esta serie
Modelos de la misma serie compatibles directamente con AD844ANZ (mismo factor de forma y huella) — difiere en Full-Power Bandwidth, Number of Circuits, Package, Process Technology.
AD844BNZ
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
AD844CNZ
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
AD844ARZ
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
AD844JNZ
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
AD844BRZ
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
AD844ANZ Valores máximos y características eléctricas
| Amplifier Type | Current Feedback Operational Amplifier |
| Number of Circuits | 1 circuit |
| Bandwidth at Gain -1 | 60 MHz |
| Bandwidth at Gain -10 | 33 MHz |
| Slew Rate | 2000 V/us |
| Full-Power Bandwidth | 20 MHz at 20 V p-p and 500 ohm load |
| Settling Time | 100 ns to 0.1% for a 10 V step |
| Supply Voltage Range | 4.5 V to 18 V |
| Corriente en reposo | 6.5 mA |
| Differential Gain Error | 0.03% at 4.4 MHz |
| Differential Phase Error | 0.16 degrees at 4.4 MHz |
| Offset Voltage | 150 uV maximum for B grade |
| Process Technology | Junction-isolated complementary bipolar |
| Encapsulado | 8-pin plastic DIP |
| Tipo de montaje | Through-hole |
Guía de configuración de pines de AD844ANZ 8-pin plastic dip
Configuración de pines para AD844ANZ (encapsulado 8-pin plastic dip). Este componente analógico presenta pines de entrada, salida y alimentación. Consulte la hoja de datos del fabricante para conocer las configuraciones de los pines de ajuste de offset, compensación y habilitación. Ideal para circuitos de acondicionamiento de señal y amplificadores.
No hay datos detallados de patillaje disponibles para AD844ANZ.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
AD844ANZ es adecuado para 6 aplicacións: High-Speed Active Filters, Video Signal Amplification, Pulse and Waveform Generation, Current-Feedback ADC Interface, Laboratory Instrumentation, Communications Signal Conditioning.
High-Speed Active Filters
The AD844ANZ is well suited to high-speed active filtering because its current-feedback architecture provides 60 MHz bandwidth at a gain of -1 and 33 MHz at a gain of -10. It can be placed around an inverting filter stage to preserve bandwidth as closed-loop gain changes. The 2000 V/us slew rate also allows the filter to process large-amplitude signals without clipping as quickly as lower-bandwidth amplifiers. Component tolerances, op-amp noise, and parasitic capacitance determine the achievable filter response, so the manufacturer feedback recommendations should be followed during layout.
Recomendado
Video Signal Amplification
The AD844ANZ can amplify video-rate signals where wide bandwidth and fast settling are important. Its 60 MHz bandwidth at a gain of -1 provides margin for common video frequencies, while the 2000 V/us slew rate supports the device's 20 MHz full-power bandwidth into 500 ohms. The amplifier may therefore be used in video distribution, line driving, or gain stages that must preserve waveform shape. In practice, source impedance, termination, feedback resistor values, and the 500 ohm loading requirement must be evaluated to avoid bandwidth or stability problems.
Recomendado
Pulse and Waveform Generation
The AD844ANZ is useful for generating and shaping fast waveforms because it combines a 2000 V/us slew rate with settling to 0.1% within 100 ns for a 10 V step. These characteristics allow pulse edges and step responses to remain controlled when the required amplitude and repetition rate are demanding. The current-feedback circuit should use the feedback values and compensation information specified in the manufacturer datasheet. Output-current capability, load capacitance, supply headroom, and thermal conditions should also be checked when driving repetitive large-amplitude signals.
Recomendado
Current-Feedback ADC Interface
The AD844ANZ can serve as an input amplifier for suitable high-speed analog-to-digital converters when the converter's sampling architecture and settling requirements are compatible with the op-amp. Its 60 MHz bandwidth and 100 ns settling specification reduce the risk of insufficient acquisition time before conversion. The actual interface bandwidth must be derived from the ADC input capacitance, sampling rate, source impedance, and complete settling-time curve rather than from op-amp bandwidth alone. Layout should minimize feedback-loop area and keep the ADC driver connections short.
Recomendado
Laboratory Instrumentation
The AD844ANZ is appropriate for laboratory instruments that require rapid response and precise large-signal behavior. Its low offset-voltage target of 150 uV maximum for the B grade, 0.03% differential gain error at 4.4 MHz, and 0.16-degree differential phase error support accurate signal conditioning. In an instrument such as a buffer, pulse generator, or calibrated gain stage, the 4.5 V to 18 V operating range supports conventional laboratory rails. Designers should account for resistor-network tolerance and temperature drift when translating amplifier accuracy into end-to-end instrument accuracy.
Recomendado
Communications Signal Conditioning
The AD844ANZ can condition communications signals that need high bandwidth and rapid large-signal response. The 60 MHz gain -1 bandwidth, 33 MHz gain -10 bandwidth, and 2000 V/us slew rate make it suitable for gain and impedance stages around moderate-rate analog links. The amplifier must be selected and biased for the signal amplitude, source impedance, termination scheme, and channel bandwidth of the specific communication standard. External filtering should account for the amplifier's gain-versus-frequency behavior, and board-level impedance control is essential for repeatable high-frequency behavior.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para AD844ANZ — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Use a conventional voltage-feedback amplifier instead when the application prioritizes very low input bias current, rail-to-rail operation, or simple unity-gain stability over high-speed large-signal performance. A conventional voltage-feedback amplifier can also be preferable when very high closed-loop gain is required and its gain-dependent bandwidth remains acceptable. For the AD844ANZ, verify the feedback network, source and load impedances, output swing, supply headroom, and thermal conditions before releasing the layout.
Comparación con alternativas
| Parámetro | Este producto | AD844BNZ | AD844CNZ | AD844ARZ | AD844JNZ | AD844BRZ |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 8-PDIP | 8-PDIP | 8-PDIP | 8-PDIP | 8-PDIP | 8-PDIP |
| Amplifier Type | Current Feedback Operational Amplifier | Current Feedback Operational Amplifier | Current Feedback Operational Amplifier | Current Feedback Operational Amplifier | Current Feedback Operational Amplifier | Current Feedback Operational Amplifier |
| Bandwidth at Gain -1 | 60 MHz | 60 MHz | 60 MHz | 60 MHz | 60 MHz | 60 MHz |
| Bandwidth at Gain -10 | 33 MHz | 33 MHz | 33 MHz | 33 MHz | 33 MHz | 33 MHz |
| Slew Rate | 2000 V/us | 2000 V/us | 2000 V/us | 2000 V/us | 2000 V/us | 2000 V/us |
| Supply Voltage Range | 4.5 V to 18 V | 4.5 V to 18 V | 4.5 V to 18 V | 4.5 V to 18 V | 4.5 V to 18 V | 4.5 V to 18 V |
| Quiescent Current | 6.5 mA | 6.5 mA | 6.5 mA | 6.5 mA | 6.5 mA | 6.5 mA |
| Settling Time | 100 ns to 0.1% for a 10 V step | 100 ns to 0.1% for a 10 V step | 100 ns to 0.1% for a 10 V step | 100 ns to 0.1% for a 10 V step | 100 ns to 0.1% for a 10 V step | 100 ns to 0.1% for a 10 V step |
| Full-Power Bandwidth | 20 MHz at 20 V p-p and 500 ohm load | 20 MHz at 20 V p-p and 500 ohm load | 20 MHz at 20 V p-p and 500 ohm load | 20 MHz at 20 V p-p and 500 ohm load | 20 MHz at 20 V p-p and 500 ohm load | 20 MHz at 20 V p-p and 500 ohm load |
| Differential Gain Error | 0.03% at 4.4 MHz | 0.03% at 4.4 MHz | 0.03% at 4.4 MHz | 0.03% at 4.4 MHz | 0.03% at 4.4 MHz | 0.03% at 4.4 MHz |
| Differential Phase Error | 0.16 degrees at 4.4 MHz | 0.16 degrees at 4.4 MHz | 0.16 degrees at 4.4 MHz | 0.16 degrees at 4.4 MHz | 0.16 degrees at 4.4 MHz | 0.16 degrees at 4.4 MHz |
Diferenciadores clave
- Retains useful bandwidth at increased closed-loop gain (frente a AD811ANZ)
- High slew rate supports full-power high-frequency operation (frente a AD811ANZ)
- Fast 0.1% settling for step-response applications (frente a AD811ANZ)
Notas de diseño
Place the feedback resistor and gain-setting resistor close to the AD844ANZ input pins, and keep the feedback trace short and electrically quiet. Current-feedback amplifiers can be sensitive to parasitic capacitance inside the feedback loop, particularly when driving capacitive loads. Use a compact layout, provide nearby supply bypassing, and verify the physical implementation with the feedback values and stability guidance in the manufacturer datasheet.
The AD844ANZ can develop 20 V peak-to-peak into 500 ohms at 20 MHz, but actual power dissipation depends on waveform shape, duty cycle, output stage efficiency, and ambient temperature. Check the device's output-current and thermal limits against the intended load rather than relying on slew rate alone. Decouple the supply rails locally and keep supply-return current away from sensitive input and feedback paths.
Do not treat the 60 MHz gain -1 bandwidth as a guaranteed bandwidth at every closed-loop gain or with every source and load. The 33 MHz figure at a gain of -10 demonstrates the current-feedback bandwidth trend, while the amplifier's stability also depends on gain resistor values, source impedance, load capacitance, and board parasitics. Recheck stability and step response whenever those conditions change.
For high-frequency operation, minimize trace length between the amplifier, feedback network, source, and load. Maintain consistent impedance paths and use short ground returns for supply bypassing. If driving a cable, long PCB trace, or ADC input, include the distributed capacitance and inductance in the simulation because the 100 ns settling specification applies under the manufacturer's stated test conditions.
Información de cumplimiento
The Analog Devices product information does not explicitly identify RoHS, REACH, halogen-free, or conflict-minerals status. AEC-Q100 qualification is not applicable to this catalog operational amplifier.