AD9100AE - Ultrahigh Speed Monolithic Track-and-Hold | Analog Devices
N.º de pieza: AD9100AE ✓ ActivoAD9100AE Descripción general
A sample-and-hold circuit is an analog signal-processing component that acquires an input voltage during a short acquisition interval and then holds that voltage approximately constant for downstream measurement or conversion. The AD9100 belongs to the sample-and-hold IC category within the broader analog IC hierarchy, where it serves as an interface between a rapidly changing source and a slower ADC, instrumentation amplifier, or control loop. Its ultrahigh acquisition speed makes timing and source-impedance behavior central to system design.
The device provides a 0.02 µs acquisition time, allowing a settling interval of 20 ns when the source and timing conditions meet the operating requirements. Its specified maximum droop rate is 6000 V/s, which characterizes how quickly the held output can move away from its captured level. Operation uses a 5 V nominal power supply, while the industrial temperature grade supports operation from -40°C to +85°C. These characteristics target applications requiring rapid acquisition and short holding intervals rather than precision, long-duration sample-and-hold systems.
The AD9100AE is identified as a monolithic sample-and-hold circuit, meaning its acquisition and holding functions are integrated on one semiconductor device. Its 20-CLCC 9 mm by 9 mm package provides a compact surface-mount implementation, but the exposed ceramic construction and high-speed signal path require careful attention to board layout. The analog input, control signals, reference arrangement, ground return, and output path should be routed with short traces and suitable return paths to preserve the intended acquisition performance.
Typical uses include high-speed data acquisition, pulsed instrumentation, digital oscilloscope input stages, closed-loop control samplers, communications test equipment, and analog-to-digital converter front ends. In each case, the system must command acquisition at the proper time and provide a sufficiently low-impedance source so the AD9100AE can reach its specified acquisition time. The 6000 V/s maximum droop rate also limits the useful holding period in applications where the sampled value must remain stable for subsequent conversion.
A key implementation consideration is the relationship between source impedance, acquisition interval, and settling accuracy. Place the input driver close to the device, keep the analog path compact, and use a ground plane that provides a low-impedance return beneath or adjacent to the signal route. Review the AD9100 datasheet for the complete pin-description table, input range, output structure, reference requirements, and recommended test circuit before finalizing the PCB.
This page consolidates the confirmed AD9100AE operating figures, package information, sourcing details, and engineering guidance into one technical reference. It also distinguishes exact same-family grade alternatives from unsupported cross-brand substitutes and provides selection criteria for engineers deciding whether the 20-lead CLCC device fits a timing-critical acquisition design.
Alternativas directas para AD9100AE — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
Variantes de esta serie
Modelos de la misma serie compatibles directamente con AD9100AE (mismo factor de forma y huella) — difiere en Product Type.
AD9100SE
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
AD9100JD
✅ Sustitución directa ⚠️ Especificaciones sin verificarConsulte el precio
Ver hoja de datos →AD9100AD
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
AD9100SD3
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
AD9100AE Valores máximos y características eléctricas
| Product Type | 1 ultrahigh-speed monolithic track-and-hold circuit |
| Acquisition Time | 0.02 µs |
| Maximum Droop Rate | 6000 V/s |
| Nominal Supply Voltage | 5 V |
| Minimum Operating Temperature | -40°C |
| Maximum Operating Temperature | 85°C |
| Temperature Grade | 1 industrial grade |
| Package Type | 1 ceramic leadless chip carrier package |
| Package Lead Count | 20 leads |
| Package Body Length | 9 mm |
| Package Body Width | 9 mm |
| Package Shape | 1 square package |
| Terminal Form | 1 no-lead terminal form |
| Mounting Technology | 1 surface-mount package |
| Estado RoHS | 1 RoHS-compliant electronic part |
Guía de configuración de pines de AD9100AE 1 square package
Configuración de pines para AD9100AE (encapsulado 1 square package). Este componente analógico presenta pines de entrada, salida y alimentación. Consulte la hoja de datos del fabricante para conocer las configuraciones de los pines de ajuste de offset, compensación y habilitación. Ideal para circuitos de acondicionamiento de señal y amplificadores.
No hay datos detallados de patillaje disponibles para AD9100AE.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
AD9100AE es adecuado para 6 aplicacións: High-Speed ADC Front Ends, Digital Oscilloscope Input Stages, Pulsed Instrumentation, Communications Test Equipment, Closed-Loop Control Samplers, Industrial Data Acquisition.
High-Speed ADC Front Ends
The AD9100AE fits an ADC front end when a rapidly changing analog signal must be captured and held for conversion. Its 0.02 µs acquisition time provides a 20 ns acquisition interval, while the 6000 V/s maximum droop rate defines how quickly the captured voltage can depart from its value. Place the sample-and-hold device near the ADC and driver so that source impedance, ADC input capacitance, and propagation delay do not consume the acquisition window. The principal trade-off is droop: a longer conversion period can permit the held output to move, so the system must complete conversion within the error budget implied by the maximum droop rate.
Recomendado
Digital Oscilloscope Input Stages
The AD9100AE can serve the input stage of a digital oscilloscope or wideband measurement instrument where rapid acquisition and controlled droop are important. The 0.02 µs acquisition time supports sampling of fast edges, and the 5 V nominal supply fits a conventional single-supply analog section. Place the device close to the input driver and acquisition clock to minimize delay and reflections. The 6000 V/s maximum droop rate requires the converter to begin acquisition at a repeatable point and complete conversion before the captured level changes by more than the instrument’s vertical-error budget.
Recomendado
Pulsed Instrumentation
For pulsed instrumentation, the AD9100AE captures a measurement at a defined instant and holds it long enough for slower downstream circuitry to process the result. Its 0.02 µs acquisition time allows the capture command to follow the pulse closely, while the 5 V nominal supply simplifies integration with monolithic analog instrumentation. Route the trigger and hold-control traces away from the sensitive input path, and terminate the source to achieve the acquisition behavior required by the test setup. Droop must be evaluated against pulse repetition rate because successive measurements can require the output to remain valid for a different interval than continuous-wave operation.
Recomendado
Communications Test Equipment
The AD9100AE is applicable to communications test equipment that must capture burst waveforms or rapidly changing envelopes before conversion and analysis. Its 0.02 µs acquisition time supports high-speed timing, and the 6000 V/s maximum droop rate provides a defined limit for hold-duration planning. Keep the RF or baseband driver close to the AD9100AE and use a continuous ground reference beneath the high-speed input route. The choice between AD9100AE and another AD9100 grade should follow the required temperature range and qualification conditions rather than basic track-and-hold functionality, since all supported family alternatives use the same 20-CLCC architecture.
Recomendado
Closed-Loop Control Samplers
The AD9100AE can acquire a control-loop variable at a synchronized instant and present it to a slower controller or ADC. The 0.02 µs acquisition time reduces the delay between the sample command and capture of a rapidly varying feedback signal. Place the device close to the feedback driver, maintain a continuous return path, and isolate hold-control traces from the analog input. Because the maximum droop rate is 6000 V/s, loop designers must include sample-and-hold error in the stability and accuracy analysis, especially when control updates occur at a low repetition rate.
Recomendado
Industrial Data Acquisition
The AD9100AE supports industrial data-acquisition modules that need a short acquisition interval while operating from -40°C to 85°C. The 5 V nominal supply allows integration into a compact 20-CLCC surface-mount design, and the 0.02 µs acquisition time is useful when the monitored signal changes during the command-to-sample interval. Protect the input path from industrial noise, provide local supply bypassing, and use a low-impedance source stage. Validate the maximum 6000 V/s droop rate against the longest conversion and processing interval to ensure that system error remains within the measurement specification.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para AD9100AE — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | AD9100SE | AD9100JD | AD9100AD | AD9100SD3 |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 20-CLCC (9x9) | 20-CLCC (9x9) | 20-CLCC (9x9) | 20-CLCC (9x9) | 20-CLCC (9x9) |
| Product Type | Monolithic track-and-hold circuit | Monolithic track-and-hold circuit | Monolithic track-and-hold circuit | Monolithic track-and-hold circuit | Monolithic track-and-hold circuit |
| Acquisition Time | 0.02 µs | 0.02 µs | 0.02 µs | 0.02 µs | 0.02 µs |
| Maximum Droop Rate | 6000 V/s | 6000 V/s | 6000 V/s | 6000 V/s | 6000 V/s |
| Nominal Supply Voltage | 5 V | 5 V | 5 V | 5 V | 5 V |
| Temperature Grade Code | AE industrial grade | SE grade code | JD grade code | AD grade code | SD3 grade code |
Diferenciadores clave
- Exact AE industrial-grade ordering option within the AD9100 family (frente a AD9100SE)
- Wide confirmed industrial operating range (frente a AD9100JD)
- Compact 20-CLCC implementation with a 9 mm by 9 mm body (frente a AD9100AD)
- Fast acquisition paired with a defined droop limit (frente a AD9100SD3)
Notas de diseño
Do not treat the 0.02 µs acquisition time as independent of the source impedance and load. Review the acquisition specification, hold command timing, input range, and output loading in the AD9100 manufacturer datasheet. The source must charge the device’s internal sampling capacitance quickly enough to meet the intended settling error. Use a nearby low-impedance driver, terminate unused inputs as directed, and measure settling at the system’s operating voltage and temperature rather than relying on a nominal acquisition value alone.
Place the AD9100AE close to the source driver and place the hold-control circuitry away from the analog input route. Keep the input trace short, avoid unnecessary test pads and stubs, and provide a continuous ground reference. The 20-CLCC footprint has fine-pitch ceramic construction, so inspect solder-joint fillets and component placement for manufacturing consistency. Use the manufacturer land pattern rather than deriving dimensions from the 9 mm by 9 mm body size alone.
Calculate the allowable hold interval from the 6000 V/s maximum droop rate and the system’s voltage-error budget. For example, an error budget of 10 mV corresponds to approximately 1.67 µs at the maximum specified droop rate. This is an estimated calculation using 6000 V/s and 0.010 V, not an additional device specification. If the downstream converter requires a longer interval, refresh the sample earlier or select a device with lower droop.
Use the AD9100 manufacturer datasheet to identify supply and ground pins before placing bypass capacitors. Place the closest decoupling capacitor directly across the appropriate supply and ground nodes, and keep the connection loop as small as practical. The cited 5 V nominal supply identifies the operating point but does not establish the permitted minimum and maximum limits or capacitor values, so confirm both in the datasheet before releasing the layout.
Información de cumplimiento
The Veswin product record identifies AD9100AE as a RoHS electronic part. No separate REACH, halogen-free, conflict-minerals, or automotive qualification statement is present in the cited product information.