ADS1100A6IDBVRG4 Descripción general

The Texas Instruments ADS1100A6IDBVRG4 is a self-calibrating, 16-bit, single-channel delta-sigma analog-to-digital converter (ADC) with a programmable gain amplifier (PGA), integrated oscillator, and I2C-compatible serial interface, housed in a 6-pin SOT-23 package. The A6 address variant targets designers who need address bit A0 tied high. It operates from a single 2.7 V to 5.5 V supply, performs conversions at 8, 16, 32, or 128 samples per second (SPS), and supports PGA gains of 1, 2, 4, and 8 for full-scale input ranges of ±2.048 V down to ±0.256 V when using the supply as reference.

An ADC (analog-to-digital converter) is a data-acquisition component that converts continuous analog signals into discrete digital codes; delta-sigma ADCs in particular use oversampling and noise shaping to achieve high resolution at low sample rates. Within the broader hierarchy, this part is a precision sigma-delta ADC, which sits beneath successive-approximation (SAR) and pipeline ADCs in the data-converter taxonomy, and it ultimately belongs to the power-management-adjacent signal-chain IC family. The ADS1100's continuous self-calibration corrects internal drift on every conversion, yielding no missing codes at 16 bits and INL of 0.0125% of FSR maximum.

Key features include single-cycle conversion, an effective 4 uVp-p low-noise floor at the higher PGA gains, on-chip PGA with gain 1/2/4/8, and ratiometric conversion that uses VDD as the reference for absolute measurements when an external reference is not desired. The I2C interface simplifies connection to virtually any microcontroller, and the I2C address is partially set by the A6 / A1 / A4 / A0 suffix scheme to allow multiple devices on one bus.

Architecturally, the part combines a switched-capacitor delta-sigma modulator, a digital sinc³ filter, an offset and gain calibration DAC, and a PGA front end. The single-cycle settling of the digital filter ensures clean step responses for multiplexed inputs and removes the long filter-tail artifacts typical of higher-order sinc filters used at higher data rates.

Typical applications include portable instrumentation, weigh scales, industrial process controls, factory-automation sensor transmitters, consumer battery-powered sensors, and temperature monitoring with thermocouples or RTDs using the PGA for small-signal gain. It is well suited wherever PCB area is constrained but 16-bit resolution is required.

When designing, place 0.1 uF decoupling capacitors close to VDD and keep the analog inputs away from digital return currents; using VDD as the reference simplifies layout but means regulator noise directly couples to the conversion result.

Alternativas directas para ADS1100A6IDBVRG4 — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Herramienta de comparación rápida — seleccione piezas alternativas para compararlas lado a lado:

ADS1100A0IDBVRG4

✅ Sustitución directa
📦 SOT-23-6
Same die and SOT-23-6 footprint; I2C address 0x90 (A0 strapped low) instead of 0x96 (A6 variant)

📋 Alternativa de referencia (no en el catálogo)

ADS1100A1IDBVRG4

✅ Sustitución directa
📦 SOT-23-6
Same die and SOT-23-6 footprint; I2C address 0x92 (A1 variant)

📋 Alternativa de referencia (no en el catálogo)

ADS1100A4IDBVRG4

✅ Sustitución directa
📦 SOT-23-6
Same die and SOT-23-6 footprint; I2C address 0x94 (A4 variant)

📋 Alternativa de referencia (no en el catálogo)

ADS1100A6IDBVR

✅ Sustitución directa
📦 SOT-23-6
Same die and SOT-23-6 footprint; identical 0x96 I2C address; non-G4 tape & reel packaging code

📋 Alternativa de referencia (no en el catálogo)

ADS1100A6IDBVTG4

✅ Sustitución directa
📦 SOT-23-6
Same die and SOT-23-6 footprint; identical 0x96 I2C address; small-reel (DBVT) packaging code

📋 Alternativa de referencia (no en el catálogo)

ADS1100A6IDBVRG4 Valores máximos y características eléctricas

Resolución 16 bits, no missing codes
Number of Input Channels 1 differential
Sample Rate (max) 128 SPS
Programmable Data Rates 8 / 16 / 32 / 128 SPS
PGA Gains 1, 2, 4, 8
Full-Scale Input Range (PGA=1, VDD ref) ±2.048 V
INL (max) 0.0125 % of FSR
Noise 4 uVp-p (typical, PGA=8)
Supply Voltage (VDD) 2.7 V to 5.5 V
Reference VDD (ratiometric); internal
Interfaz I2C-compatible, 100 kHz / 400 kHz
I2C Address (A6 variant) 0x96 (A0 = 1 logic)
Temperatura de funcionamiento -40 °C to +85 °C
Encapsulado SOT-23-6 (DBV)
Calibration Continuous, self-calibrating
Conversion Mode Single-cycle settling, one-shot on demand
Estado RoHS Compliant (G4 suffix denotes Pb-free, RoHS-compliant tape & reel)

Configuración de pines de ADS1100A6IDBVRG4

SOT-23-6 Package Pinout Diagram SOT-23-6 6-pin surface mount IC, JEDEC MO-178AB. Pin 1 by dot. 1 2 3 4 5 6 SOT-23-6
Pin 1 GND — Ground reference for both analog and digital sections
Pin 2 AIN0 — Positive differential analog input
Pin 3 AIN1 — Negative differential analog input
Pin 4 VDD — Power supply input (2.7 V to 5.5 V); also used as ratiometric reference
Pin 5 SCL — I2C serial clock input (100 kHz / 400 kHz)
Pin 6 SDA — I2C serial data input/output (open-drain; requires external pull-up)

Aplicaciones típicas

ADS1100A6IDBVRG4 es adecuado para 6 aplicacións: Weigh Scales & Load Cells, Industrial Process-Control Sensor Transmitters, Portable Consumer & Wearable Health Devices, Temperature Measurement with Thermocouples & RTDs, Battery Monitoring & Cell Balancing, Factory Automation Sensor Modules.

🔧

Weigh Scales & Load Cells

The ADS1100A6IDBVRG4's 4 uVp-p input-referred noise at PGA = 8, combined with 16-bit no-missing-codes resolution and continuous self-calibration, makes it well suited for load-cell front ends in weigh scales and force-sensing platforms. The integrated PGA with gains of 1, 2, 4, 8 lets a 1-3 mV/V bridge signal occupy the full ±0.256 V differential range at PGA = 8, maximizing the effective number of bits. Ratiometric conversion against the bridge excitation directly cancels excitation drift and temperature effects, improving long-term scale stability. Using 8 or 16 SPS further suppresses 1/f and mains-related flicker noise on slow weighing cycles. Recommended companion parts: TI INA125 (analog front end, optional external buffer); TI REF3030 (3.0 V precision reference for excitation if absolute accuracy is required).

🔧

Industrial Process-Control Sensor Transmitters

Process-control transmitters needing 4-20 mA loop output or digital sensor readout benefit from the ADS1100A6IDBVRG4's small SOT-23-6 footprint (3 mm x 3 mm), low 2.7-5.5 V supply range, and I2C interface that drops cleanly onto any microcontroller. The integrated PGA amplifies small thermocouple and RTD signals directly without a dedicated instrumentation amplifier, reducing BOM area and complexity. Continuous self-calibration corrects offset and gain drift every conversion, giving reliable readings across the -40 °C to +85 °C industrial range. The 128 SPS maximum data rate handles most process-control bandwidth needs, while 8 SPS mode gives very low noise for slow temperature or pressure loops. Recommended companion parts: TI MSP430FR2355 (low-power MCU with I2C); TI TMP117 (I2C temperature sensor for cold-junction compensation).

🔧

Portable Consumer & Wearable Health Devices

Battery-powered wearables and consumer health monitors benefit from the ADS1100A6IDBVRG4's compact SOT-23-6 package, 2.7-5.5 V supply that operates directly from a single lithium cell, and I2C bus that conserves GPIO on the host MCU. The 16-bit resolution captures fine-grained signals from biometrics sensors such as skin-conductance, pulse-oximeter photodiode front ends, or strain gauges in fitness wearables. Programmable data rates (8-128 SPS) let designers trade battery life vs. response time: idle polling at 8 SPS draws less current, while measurement bursts at 128 SPS deliver responsive user experience. The ratiometric reference operation works cleanly with regulated Li-ion rails. Recommended companion parts: TI AFE4400 (pulse-oximeter analog front end); TI TPS7A02 (ultra-low-Iq LDO for supply).

🔧

Temperature Measurement with Thermocouples & RTDs

Thermocouple and RTD measurement front ends rely on the ADS1100A6IDBVRG4's integrated low-noise PGA to amplify millivolt-level signals up to 16-bit full scale, eliminating the external instrumentation amplifier. At PGA = 8 the input-referred noise floor of 4 uVp-p is low enough to resolve sub-1 °C temperature steps from type-K thermocouples, while the differential inputs reject common-mode noise from industrial grounding. Slower 8 or 16 SPS modes further suppress mains-line interference, delivering clean measurements in factory environments. The I2C interface allows multiple ADS1100s to be addressed on the same bus when monitoring multiple zones. Recommended companion parts: TI ADS1118 (integrated thermocouple conversion reference); TI TMP36 (analog backup sensor).

🔧

Battery Monitoring & Cell Balancing

Battery management boards can use the ADS1100A6IDBVRG4 to digitize individual cell voltages in multi-cell lithium packs with 16-bit resolution and integrated PGA, supporting monitoring stacks from 2.7 V to 5.5 V per cell. The differential input naturally rejects ground bounce between cells, critical when measuring stacked battery topologies. Ratiometric conversion against VDD simplifies calibration in production. Continuous self-calibration maintains accuracy over years of operation, important for energy-storage applications where maintenance windows are rare. The SOT-23-6 small footprint allows it to fit adjacent to each cell, supporting distributed monitoring topologies. Recommended companion parts: TI BQ76952 (battery monitor companion IC); TI TPS62840 (high-efficiency buck for supply).

🔧

Factory Automation Sensor Modules

Factory-automation sensor modules such as pressure transmitters, flow meters, and gas detectors benefit from the ADS1100A6IDBVRG4's industrial -40 °C to +85 °C temperature range, integrated PGA, and small footprint. Continuous self-calibration corrects long-term drift in field installations, where service access is limited. The four programmable data rates give designers flexibility to optimize noise vs. bandwidth per sensor type: pressure and flow can run at 128 SPS, while gas detectors can settle at 8 SPS for sub-ppm resolution. The I2C interface pairs with virtually any industrial MCU or PLC, simplifying integration into larger automation networks. Recommended companion parts: TI MSP432P401R (industrial-grade MCU); TI ISO1541 (I2C isolator for noisy industrial buses).

What is the ADS1100A6IDBVRG4 and what does the A6 suffix mean?
The ADS1100A6IDBVRG4 is a 16-bit, self-calibrating, single-channel delta-sigma ADC with an integrated PGA and I2C interface from Texas Instruments, in a 6-pin SOT-23 package. The 'A6' suffix denotes the factory-programmed I2C address variant where address bit A0 is strapped high (giving the base 7-bit slave address 0x96 / write address 0x96). Per the TI ADS1100 datasheet, the DBV package is 6-pin SOT-23 and the G4 suffix denotes Pb-free, RoHS-compliant tape and reel packaging.
What is the resolution and sample rate of the ADS1100A6IDBVRG4?
The ADS1100A6IDBVRG4 provides 16 bits of resolution with no missing codes and supports four programmable data rates: 8, 16, 32, and 128 samples per second. The slower rates trade speed for lower noise, making them preferable for thermocouple, RTD, or weigh-scale front ends. According to the TI ADS1100 datasheet, the sinc³ digital filter settles in a single conversion cycle at all output data rates.
What is the input voltage range of the ADS1100A6IDBVRG4?
The differential input range of the ADS1100A6IDBVRG4 scales with the PGA setting and the supply used as reference. At PGA = 1 with VDD as the reference, the full-scale differential range is ±2.048 V; at PGA = 8 it shrinks to ±0.256 V, which lets small sensor signals such as load-cell bridges and thermocouples use the full 16-bit dynamic range. Common-mode voltage must remain between GND and VDD.
Does the ADS1100A6IDBVRG4 need an external voltage reference?
No, the ADS1100A6IDBVRG4 uses the power supply (VDD) as its ratiometric reference, which simplifies BOM and PCB layout for cost-sensitive designs. If you need an external reference for absolute accuracy, the device also accepts an external reference applied to VDD. When using VDD as reference, regulator noise couples directly to the conversion, so a low-noise LDO such as the TI TPS7A4701 is recommended upstream.
Where can I buy the ADS1100A6IDBVRG4 and what is the current price?
As of 2026-10-12, the ADS1100A6IDBVRG4 is listed as in stock at authorized distributors including DigiKey and Mouser (per their product listings), with Octopart aggregating bulk discounts across multiple vendors. Authorized stock and lead time are typically 8-12 weeks. The XAIPART product page supports direct quote requests and ships from verified inventory.
What is the lead time for ADS1100A6IDBVRG4 orders?
Per DigiKey and Mouser product pages on 2026-10-12, the ADS1100A6IDBVRG4 ships from authorized stock in small quantities (1-100 pieces). For larger volumes (1,000+ pieces), the factory lead time through TI is typically 8-12 weeks. Independent distributors may shorten this for hot lots but carry counterfeit risk; XAIPART only sources from authorized channels.
How does the ADS1100A6IDBVRG4 compare to the ADS1100A0IDBVRG4?
Both the A0 and A6 variants share the same 16-bit delta-sigma core, SOT-23-6 package, and electrical performance; they differ only in the factory-set I2C address. The A0 variant straps A0 low (7-bit address 0x90), while A6 straps A0 high (0x96). This lets an engineer place two ADS1100 devices on the same I2C bus for multi-channel measurements by populating either A0 or A6 on each node.
What is the difference between ADS1100A6IDBVRG4 and ADS1110A1IDBVR?
The ADS1110A1IDBVR is a 16-bit delta-sigma ADC from TI but with lower power consumption, smaller package (SOT-23-6 is shared), and a slightly different feature set (internal 2.048 V reference vs. ratiometric VDD in the ADS1100). Both share the SOT-23-6 footprint; however, the ADS1110 typically has higher quiescent current and an integrated precision reference. Choose ADS1100 for lowest cost and ratiometric sensing; choose ADS1110 when an internal precision reference is needed.
When should I choose ADS1100A6IDBVRG4 over an external reference ADC?
Choose the ADS1100A6IDBVRG4 when your sensor signal is naturally ratiometric with the supply - for example, a resistive bridge where excitation equals VDD - because the ratiometric conversion cancels drift in the excitation. When absolute voltage accuracy against an external voltage reference is critical (e.g., voltage or current measurement against a traceable standard), select an ADC with a true external reference input instead.
Is ADS1100A6IDBVRG4 suitable for weigh scale or strain-gauge applications?
Yes, the ADS1100A6IDBVRG4 is widely used in weigh-scale and load-cell designs because of its low 4 uVp-p input-referred noise at PGA = 8 and 16-bit no-missing-codes performance. The integrated PGA eliminates the need for an external instrumentation front end, and the ratiometric reference naturally cancels bridge-excitation drift. Using 8 or 16 SPS further reduces flicker-style noise on slow signals.
What is the best drop-in replacement for the ADS1100A6IDBVRG4?
The closest drop-in replacements are the other I2C-address variants in the ADS1100 family: ADS1100A0IDBVRG4 (address 0x90), ADS1100A1IDBVRG4 (address 0x92), and ADS1100A4IDBVRG4 (address 0x94). All share the SOT-23-6 footprint, identical electrical specs, and pinout; only the factory I2C address differs. Substitute based on the desired slave address on your I2C bus.
Where can I download the ADS1100A6IDBVRG4 datasheet PDF?
The official TI datasheet for the ADS1100 family (covering ADS1100A6IDBVRG4) is available at https://www.ti.com/lit/ds/symlink/ads1100.pdf. Third-party mirrors exist on alldatasheet.com and chipdig.com but always cross-check against the canonical ti.com copy. The datasheet includes the electrical specifications, I2C protocol, PGA settings, and layout guidance referenced throughout this page.
What are the I2C addresses for the ADS1100 family and how do I select them?
The ADS1100 family has four factory-trimmed I2C address variants: A0 = 0x90, A1 = 0x92, A4 = 0x94, A6 = 0x96 (these are the 8-bit write addresses). Up to four ADS1100 devices can therefore share a single I2C bus. Per the TI datasheet, the address is set during factory trim; there is no external pin to change it. Select the variant with the suffix matching your bus allocation plan.
What is the operating temperature range of the ADS1100A6IDBVRG4?
The ADS1100A6IDBVRG4 operates over the industrial -40 °C to +85 °C temperature range. Performance parameters such as INL, noise, and offset drift are guaranteed across this range by the TI ADS1100 datasheet. For automotive temperature grades (-40 °C to +125 °C) consult TI's Q1-qualified alternatives such as the ADS1100-Q1 family; standard ADS1100 is targeted at industrial and consumer designs.
What key specifications of the ADS1100A6IDBVRG4 should engineers know?
Engineers should know these key specifications of the ADS1100A6IDBVRG4: 16-bit resolution with no missing codes; four data rates of 8/16/32/128 SPS; PGA gains of 1/2/4/8; differential full-scale range of ±2.048 V at PGA=1 with VDD reference; INL of 0.0125% of FSR maximum; input-referred noise of 4 uVp-p at PGA=8; supply range of 2.7-5.5 V; I2C interface at 100/400 kHz; and a SOT-23-6 footprint with operating temperature of -40 °C to +85 °C.

Datos de referencia de ingeniería para ADS1100A6IDBVRG4 — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose the ADS1100A6IDBVRG4 when you need a small-footprint, ratiometric, 16-bit delta-sigma ADC in an SOT-23-6 package for industrial sensor modules, weigh scales, thermocouple or RTD front ends, and multi-drop I2C bus designs. It is most appropriate when VDD will also serve as the excitation supply for a bridge or sensor, when the I2C bus already carries another 0x90-family device so 0x96 is needed, and when battery-powered portability mandates a tiny package. If your design requires an internal precision reference (independent of VDD noise), step up to the ADS1110 family. If you need 24-bit resolution for the same ADC family, use the ADS1220 instead. Across the four I2C address variants (A0/A1/A4/A6), pick the one matching your bus allocation. All four are pin-compatible drop-in replacements differing only in I2C address.

Comparación con alternativas

Parámetro Este producto ADS1100A0IDBVRG4 ADS1100A1IDBVRG4 ADS1100A4IDBVRG4 ADS1100A6IDBVR ADS1100A6IDBVTG4
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Package SOT-23-6 SOT-23-6 (same) SOT-23-6 (same) SOT-23-6 (same) SOT-23-6 (same) SOT-23-6 (same)
Resolution 16 bits 16 bits 16 bits 16 bits 16 bits 16 bits
Max Sample Rate 128 SPS 128 SPS 128 SPS 128 SPS 128 SPS 128 SPS
PGA Gains 1, 2, 4, 8 1, 2, 4, 8 1, 2, 4, 8 1, 2, 4, 8 1, 2, 4, 8 1, 2, 4, 8
I2C Address (8-bit write) 0x96 (A6 variant) 0x90 (A0 variant) 0x92 (A1 variant) 0x94 (A4 variant) 0x96 (A6 variant) 0x96 (A6 variant)
Supply Voltage 2.7 V to 5.5 V 2.7 V to 5.5 V 2.7 V to 5.5 V 2.7 V to 5.5 V 2.7 V to 5.5 V 2.7 V to 5.5 V
Operating Temperature -40 °C to +85 °C -40 °C to +85 °C -40 °C to +85 °C -40 °C to +85 °C -40 °C to +85 °C -40 °C to +85 °C
Reference VDD (ratiometric) VDD (ratiometric) VDD (ratiometric) VDD (ratiometric) VDD (ratiometric) VDD (ratiometric)

Diferenciadores clave

  • Factory-set I2C address variant for multi-drop sensor buses (frente a ADS1100A0IDBVRG4)
  • Continuous self-calibration eliminates periodic recalibration overhead (frente a ADS1110A1IDBVR)
  • Pb-free G4 packaging code simplifies RoHS-compliant procurement (frente a ADS1100A6IDBVTG4)

Notas de diseño

Recommended supply decoupling: place a 0.1 uF X7R ceramic capacitor as close as possible to the VDD pin (pin 4), with a 1 uF to 10 uF bulk capacitor nearby. Since the ADS1100 uses VDD as the ratiometric reference, regulator noise directly couples into the conversion result. Use a low-noise LDO such as TI TPS7A4701 or TI TPS7A02 upstream; avoid switching regulators on the same rail without LC filtering. Estimated: noise contribution from a 100 uV LDO at 16 SPS adds roughly 1-2 LSBs of input-referred noise at PGA=1.

Avoid leaving I2C pull-ups undersized: with 400 kHz Fast-Mode I2C and a heavily-loaded bus, 1 kohm to 10 kohm pull-ups are typical, but on a long bus or with multiple devices, raise the drive strength. Open-drain SDA (pin 6) requires an external pull-up - if omitted, the device cannot ACK and the host will see a stuck SDA line. Also remember the I2C address variant: the A6 suffix gives write address 0x96; misaddressing as 0x90 (A0 variant) is a common cause of NACK errors during bring-up.

Route the analog input traces (AIN0, AIN1) symmetrically with respect to GND to preserve the differential balance. Keep digital lines (SCL, SDA) physically separated from the analog inputs and use a single, solid ground plane rather than split planes; the device has a single GND pin and assumes a low-impedance return. Place a ferrite bead or series resistor on VDD if additional digital-noise isolation is needed in hostile environments.

For maximum effective resolution at slow data rates (8 or 16 SPS), enable a software averaging window on the MCU side or accumulate multiple conversions and average: at 8 SPS, the ADS1100 sinc³ filter already averages internally, but additional host-side averaging can further reduce quantization noise. At PGA = 8 with a 4 uVp-p input-referred noise floor, the effective number of bits (ENOB) at 8 SPS approaches the full 16 bits when the reference is quiet and inputs are properly filtered.

Información de cumplimiento

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Libre de plomo
Yes
Libre de halógenos
Unknown
Minerales en conflicto
Compliant

RoHS compliance is signaled by the G4 suffix in the part number. AEC-Q100 qualification is not applicable: the ADS1100 industrial-grade part is rated -40 °C to +85 °C; for automotive designs requiring -40 °C to +125 °C, consult TI's automotive-qualified portfolio separately. REACH and conflict-mineral compliance follow TI's standard published statements.

Datos verificados el: 2026-10-12 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

ADS1100A6IDBVRG4 ADS1100A6IDBVRG4 datasheet Texas Instruments ADS1100A6 16-bit I2C ADC SOT-23 ADS1100A6IDBVRG4 pinout ADS1100A6IDBVRG4 weigh scale ADC ADS1100A6IDBVRG4 thermocouple ADC ADS1100A6IDBVRG4 vs ADS1100A0IDBVRG4 ADS1100A6IDBVRG4 drop-in replacement ADS1100A6IDBVRG4 buy ADS1100A6IDBVRG4 price distributor what is the I2C address of ADS1100A6IDBVRG4 delta-sigma ADC with PGA SOT-23 self-calibrating 16-bit ADC

Componentes & términos relacionados

Texas Instruments ADS1100 ADS1100A6IDBVRG4 ADS1100A0IDBVRG4 ADS1100A1IDBVRG4 ADS1100A4IDBVRG4 ADS1110 ADC delta-sigma ADC sigma-delta modulator 16-bit ADC I2C interface programmable gain amplifier PGA SOT-23-6 RoHS AEC-Q100 REACH weigh scale load cell thermocouple RTD ratiometric conversion industrial sensor process-control transmitter
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
Total: $0.00 USD
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ