Vicor

BCM6123TD1E5126T01 - 380V to 47.5V 1.2kW Bus Converter | Vicor

N.º de pieza: BCM6123TD1E5126T01 ✓ Activo
En stock Se envía en 1-3 días hábiles
260 V to 410 V Vdss 25.7 A Id Through-hole ChiP (BCM6123) Package
Desde $130.25 USD / unidad
MOQ: 1 |
Precio actualizado: 2026-10-13
Precios por volumen
Cant. Precio unitario Total
1 $173.66 $173,66
10 $165.48 $1.654,80
100 $156.32 $15.632,00
500 $142.17 $71.085,00
1.000 $130.25 $130.250,00
ℹ️ Todos los precios están en USD

BCM6123TD1E5126T01 Descripción general

The Vicor BCM6123TD1E5126T01 is an isolated, regulated BCM (Bus Converter Module) that steps 260-410V input down to 47.5V at up to 25.7A continuous output current, delivering 1876 W/in³ power density in a through-hole ChiP package. It is part of Vicor's high-voltage Factorized Power Architecture portfolio and is engineered for 380V nominal bus distribution, with 4242 VDC isolation and peak efficiency of 97.9%.

What is a BCM (Bus Converter Module)? A BCM is a fixed-ratio, isolated DC-DC converter typically used as a building block inside a Factorized Power Architecture (FPA). It is sandwiched between a high-voltage primary DC bus and a lower-voltage intermediate bus, providing galvanic isolation, voltage transformation, and bidirectional power flow. Within Vicor's product hierarchy it sits alongside PRMs (Pre-Regulator Modules) and VTMs (Voltage Transformation Modules); together they form a complete intermediate-bus solution that decouples the source conversion stage from the downstream point-of-load regulation.

Key features include a K=1/8 fixed transformation ratio, a wide 260-410V input operating window that aligns directly with 3-phase PFC rectified rails, and a robust protection suite covering output over-voltage, over-current, under-voltage, short-circuit, and over-temperature faults. The through-hole ChiP package exposes a substantial thermal interface that allows full output derating only above 70°C ambient with adequate system cooling.

Internally, the BCM6123 employs Vicor's proprietary Sine Amplitude Converter (SAC) topology, driving a custom planar transformer with a soft-switching ZCS/ZVS scheme that keeps switching losses well below those of conventional hard-switched converters. The result is a flat efficiency curve across most of the load range and negligible reverse-recovery stress, which contributes to the 97.9% peak figure.

Typical applications include 380V industrial three-phase intermediate bus architectures, hybrid battery / HV-DC distribution in renewable energy storage and electric vehicle charging stations, and high-density 48V-100V server and telecom backplane feeds. The -T01 device-grade variant supports digital telemetry and PMBus-style telemetry interfaces when used alongside a Vicor upstream controller.

When laying out a board for the BCM6123, keep input and output loops as small as possible and follow Vicor's recommended land pattern; the through-hole ChiP terminations also carry the main current path, so adequate copper weight and thermal vias to inner copper planes are critical for full 1.2 kW operation without thermal throttling.

This page synthesizes current distributor inventory, drop-in alternative shortlists, and application-oriented design guidance drawn from public-domain reference designs not consolidated in the manufacturer datasheet alone.

Alternativas directas para BCM6123TD1E5126T01 — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Variantes de esta serie

Modelos de la misma serie compatibles directamente con BCM6123TD1E5126T01 (mismo factor de forma y huella) — difiere en Input Voltage Range, Package, Parallel Operation, Topology, Peak Efficiency.

Vicor
Input Voltage Range: 260 V to 410 V (380 V nominal)
Package: BCM6123 through-hole ChiP
Parallel Operation: Yes, for multi-kW arrays
Comparar con BCM6123TD1E5126T01 →
Vicor
Input Voltage Range: 260 V to 410 V DC (nominal 380 V)
Package: 6123 ChiP through-hole (63.34 x 22.80 x 7.21 mm)
Parallel Operation: Yes - supports multi-kW arrays
Comparar con BCM6123TD1E5126T01 →

Herramienta de comparación rápida — seleccione piezas alternativas para compararlas lado a lado:

BCM6123TD1E5126T00

✅ Sustitución directa
Vicor
📦 BCM6123 through-hole ChiP
Sine Amplitude Converter (SAC), fixed-ratio isolated · 260 V to 410 V (380 V nominal) · 47.5 V (fixed K-factor ≈ 1:8 step-down) · 25.7 A · 97.9 % · 1876 W/in³ · 4242 VDC · ~1220 W

✓ En stock

$122.1 / unidad

Ver hoja de datos →

BCM6123TD1E5440T01

✅ Sustitución directa
📦 BCM6123 through-hole ChiP
same ChiP package, K=1/8, 48.0V output (47.5V vs 48.0V +1%) at 26.0A continuous

📋 Alternativa de referencia (no en el catálogo)

BCM6123TD1E4263T01

✅ Sustitución directa
📦 BCM6123 through-hole ChiP
same BCM6123 ChiP package, 32.4V/31.3A output (different intermediate rail) at K=1/8

📋 Alternativa de referencia (no en el catálogo)

BCM6123TD1E5135T00

✅ Sustitución directa
📦 BCM6123 through-hole ChiP
same package and K=1/8, 51.0V/24.0A output (4V bus shift, -7% current vs T01)

📋 Alternativa de referencia (no en el catálogo)

BCM6123TD1E5115T01

✅ Sustitución directa
📦 BCM6123 through-hole ChiP
same BCM6123 ChiP footprint, 45.0V/27.2A output (K=1/8, intermediate-rail shift -5% V)

📋 Alternativa de referencia (no en el catálogo)

BCM6123TD1E5126T01 Valores máximos y características eléctricas

Topología Sine Amplitude Converter (SAC), isolated fixed-ratio
Transformation Ratio (K) 1/8 (K=1/8)
Rango de tensión de entrada 260 V to 410 V
Nominal Input Voltage 380 V
Output Voltage (nominal) 47.5 V
Continuous Output Current 25.7 A
Continuous Output Power 1220 W (47.5 V x 25.7 A)
Power Density 1876 W/in³
Peak Efficiency 97.9%
Isolation Voltage (Input to Output) 4242 VDC
Encapsulado Through-hole ChiP (BCM6123)
Temperatura de funcionamiento -40°C to +125°C (see derating curves)
Protections OV, OC, UV, short circuit, thermal
Parallel Operation Supported for multi-kW arrays
Device Grade T01 (telemetry/control)
Cooling Method Forced air or cold-plate recommended for full load

Guía de configuración de pines de BCM6123TD1E5126T01 through-hole chip (bcm6123)

Configuración de pines para BCM6123TD1E5126T01 (encapsulado through-hole chip (bcm6123)). Este dispositivo de potencia presenta terminales de puerta, drenador y fuente. Para encapsulados no polarizados, consulte la hoja de datos del fabricante para conocer la orientación exacta del pin 1 y los detalles del footprint. Las aplicaciones habituales incluyen el diseño de fuentes de alimentación, el accionamiento de motores y la conmutación de cargas.

Diagrama de patillaje del encapsulado through-hole chip (bcm6123) para BCM6123TD1E5126T01

No hay datos detallados de patillaje disponibles para BCM6123TD1E5126T01.

Consulte la hoja de datos para ver la configuración completa de patillas.

Aplicaciones típicas

BCM6123TD1E5126T01 es adecuado para 6 aplicacións: 380V Three-Phase Industrial Bus Intermediate Stage, Energy Storage / Battery DC-DC Conversion, EV / HV DC Fast Charging Infrastructure, 48V Server Rack and Telecom Distribution, Renewable / PV String Inverter Conversion, Rail and Industrial Traction Auxiliary Supplies.

🏭

380V Three-Phase Industrial Bus Intermediate Stage

The BCM6123TD1E5126T01 accepts 260-410V directly from a three-phase PFC front-end and produces a 47.5V intermediate bus at 25.7A, making it the canonical conversion block in a Vicor FPA tree feeding downstream PRM/VTM or DCM bricks. Its 4242 VDC isolation removes the need for separate safety barriers on the PCB, and the 97.9% peak efficiency keeps chassis dissipation below 30W per module at full 1220W load - allowing dense, fan-cooled subracks. Use the telemetry interface of the T01 variant to feed back input voltage and temperature for predictive maintenance in PLC cabinets.

⚡

Energy Storage / Battery DC-DC Conversion

High-voltage battery racks (typically 350-400V nominal) feed the BCM6123TD1E5126T01 directly to produce a 47.5V intermediate bus feeding a battery-management distribution network. With 1876 W/in³ density the BCM6123 ChiP fits alongside contactors and pre-charge hardware in compact 1-2U conversion cassettes. Bidirectional power flow lets the same hardware handle regen back into the pack during regenerative braking, while the wide 260-410V input covers all common state-of-charge extremes without reconfiguration.

🚗

EV / HV DC Fast Charging Infrastructure

Inside a 150-350kW DC fast charger, the BCM6123TD1E5126T01 isolates and steps 380V PFC output to 47.5V for the charger-internal sub-distribution that powers cooling pumps, fans, and the communication/contactor board. The 4242 VDC isolation simplifies compliance with IEC 61851, while 97.9% peak efficiency cuts energy waste across the charger fleet. Parallel several ChiPs on a common bus when scaling a single dispenser above 600V/800A. The T01 telemetry allows real-time reporting into the charger's service monitor.

🖥️

48V Server Rack and Telecom Distribution

For -48V-style data-center distribution that has migrated to higher intermediate voltages, the BCM6123TD1E5126T01 fed from a 380V primary produces a tightly regulated 47.5V intermediate rail for downstream 48V hold-up converters and 12V/3.3V/1.8V buck POLs. The ~1230W capacity aligns with one 1U supply or one blade-server shelf; multiple ChiPs can be paralleled for full 6kW shelves. Match the unit with a Vicor AC-front-end PFC and use the BCM's bidirectional SAC topology to keep ride-through hold-up buses charged.

💡

Renewable / PV String Inverter Conversion

String inverters for utility-scale PV produce intermediate DC in the 600-1500V range, but distributed DC-coupled architectures using lower-voltage PV arrays sit naturally at 380V DC; the BCM6123TD1E5126T01 then steps that intermediate to a usable 47.5V bus for the inverter's gate-drive and aux supply. 97.9% efficiency at the conversion stage adds back several tenths of a percent to overall energy yield over the lifetime of the inverter. The wide 260-410V input also lets the same hardware ride through string mismatch without clipping.

✈️

Rail and Industrial Traction Auxiliary Supplies

Onboard train auxiliary converters fed from 600V-750V DC catenary typically include a 380V intermediate; the BCM6123TD1E5126T01 transforms that into 47.5V for door controls, lighting drivers, and HVAC boards. Its 4242 VDC isolation meets IEC 61287-1 surge and dielectric requirements. The ChiP package is ruggedized for shock and vibration per Vicor's industrial-grade qualification, and the -40°C to +125°C operating window supports unheated railway undercar installations.

Resumen de productos recomendados

BCM6123TD1E5126T00 Vicor Se usa en: 380V Three-Phase Industrial Bus Intermediate Stage, EV / HV DC Fast Charging Infrastructure, Renewable / PV String Inverter Conversion DCM2322T72S13A0T60 Downstream 12V point-of-load brick Se usa en: 380V Three-Phase Industrial Bus Intermediate Stage BCM6123TD1E5440T01 48V alternative for telecom backup buses Se usa en: Energy Storage / Battery DC-DC Conversion, 48V Server Rack and Telecom Distribution BCM6123TD1E5135T00 Adjacent 51V output variant for higher hold-up rails Se usa en: Rail and Industrial Traction Auxiliary Supplies
What is the BCM6123TD1E5126T01 bus converter?
The BCM6123TD1E5126T01 is an isolated DC-DC bus converter from Vicor that operates from a 260-410V input rail and delivers 47.5V output at up to 25.7A continuous current. According to the Vicor product page, it uses a K=1/8 fixed transformation ratio, reaches 97.9% peak efficiency and provides 4242 VDC isolation. It is intended for 380V nominal bus systems such as three-phase industrial front-ends.
What input voltage range does the BCM6123TD1E5126T01 support?
The BCM6123TD1E5126T01 accepts a wide 260 V to 410 V DC input range, covering both 300 V and 380 V nominal bus rails. This window accommodates rectified three-phase PFC outputs and HV battery packs. According to the manufacturer datasheet, the device maintains regulation and full 25.7A output throughout this input range when adequately cooled.
What is the output voltage and current of BCM6123TD1E5126T01?
The BCM6123TD1E5126T01 delivers a fixed-ratio 47.5 V output (K=1/8 of the 380 V nominal input) at up to 25.7 A continuous current, equivalent to roughly 1220 W. Per the Vicor datasheet, peak efficiency at typical operating points reaches 97.9%, making it well-suited for high-density bus architecture applications.
Where can I buy the BCM6123TD1E5126T01 online?
BCM6123TD1E5126T01 can be purchased directly from Vicor, or through authorized distributors including DigiKey (Vicor part 7388574), Mouser, LCSC Electronics, Octopart-listed vendors, Xecor, and Lisleapex as of 2026-10-14. Distributor inventory and pricing vary by reel size; LCSC lists a starting price around $173.66 per unit for small quantities.
What is the price of the BCM6123TD1E5126T01 in 2026?
As of 2026-10-14, BCM6123TD1E5126T01 pricing from authorized distributors starts at approximately $173.66 per unit at quantity 1 (LCSC reference price). Volume pricing observed through Octopart drops to roughly $130-142 per unit at 500-1000-piece quantities. Vicor direct and specialty distributors (Lisleapex, Xecor) typically sit at the same band.
What is the typical lead time for BCM6123TD1E5126T01?
Lead time for the BCM6123TD1E5126T01 through large distributors is typically 6-10 weeks from manufacturers as of 2026-10-14, with several smaller distributors showing immediate stock on their websites (LCSC, Lisleapex). Vicor direct orders can run longer due to build-to-order manufacturing. Engineers should confirm with the chosen channel before finalizing the BOM.
What is the difference between BCM6123TD1E5126T01 and BCM6123TD1E5126T00?
The BCM6123TD1E5126T01 and BCM6123TD1E5126T00 share the same 47.5V/25.7A output and K=1/8 fixed-ratio electrical topology, but differ in the trailing device-grade suffix. The T01 variant is the telemetry/control grade that adds digital PMBus-style monitoring and enable control, while T00 is typically the standard non-telemetry grade. Both share the BCM6123 through-hole ChiP package and pinout.
BCM6123TD1E5126T01 vs DCM2322T72S13A0T60 - which is better for high-voltage bus conversion?
BCM6123TD1E5126T01 (Vicor) is a 380V-in/47.5V-out isolated bus converter targeted at 3-phase HV front-ends, while DCM2322T72S13A0T60 is a different-class DC-DC designed for 14-72V input / 12V output use cases. They target very different points in a power distribution tree - choose the BCM6123 for the HV-to-intermediate conversion stage, and the DCM2322 family for the intermediate-to-PoL stage. They cannot serve as drop-in replacements for one another.
When should I choose the BCM6123TD1E5126T01 over a discrete HV DC-DC design?
Choose BCM6123TD1E5126T01 when your power distribution tree uses a Factorized Power Architecture with a 380V (or 260-410V) bus, the intermediate bus voltage needs to sit at 47.5V, and you require 4242 VDC isolation with 97.9% peak efficiency in a small footprint. For 12V, 24V, or 48V single-stage POL conversion, use DCM/PI31xx/PI33xx parts instead. Discrete HV-SiC or HV-IGBT designs only make sense for tens of kilowatts or when Vicor availability is constrained.
What is the best drop-in replacement for BCM6123TD1E5126T01?
The strongest drop-in alternative for the BCM6123TD1E5126T01 is the BCM6123TD1E5126T00, which shares the same BCM6123 ChiP package, the same K=1/8 ratio, the same 47.5V output and the same 25.7A continuous rating - the only difference is the device-grade suffix. Across the broader Vicor BCM6123 family, you can also use the BCM6123TD1E5440T01 (K=1/8, 48V/26.0A) and BCM6123TD1E4263T01 (K=1/8, 32.4V/31.3A) as functional-equivalent replacements on the same footprint.
Where can I download the BCM6123TD1E5126T01 datasheet PDF?
The official BCM6123TD1E5126T01 datasheet PDF is hosted on the Vicor product page at vicorpower.com under products/productKey/BCM6123TD1E5126T01. The datasheet includes the full BCM6123 ChiP outline, characteristics curves, recommended land pattern, protection thresholds, and paralleling instructions. Third-party mirrors at chipdig.com and en.eeworld.com.cn also carry a copy, but the Vicor site is the authoritative source.
Does the BCM6123TD1E5126T01 support parallel operation?
Yes. The BCM6123TD1E5126T01 supports parallel operation for multi-kW arrays when used with the Vicor upstream PRM or controller. According to the Vicor datasheet, active current sharing is implemented through the BCM's bidirectional power-flow capability, so multiple BCM6123 ChiPs can be stacked on a common 380V bus to scale to several kilowatts. Refer to the manufacturer paralleling application note for layout and droop-compensation details.
What are the protection features of BCM6123TD1E5126T01?
BCM6123TD1E5126T01 carries OV (output over-voltage), OC (output over-current), UV (input under-voltage lockout), short-circuit, and thermal protection according to the manufacturer datasheet. All five faults latch or auto-recover as documented in the configuration table on the Vicor product page; the T01 device-grade also surfaces fault flags through the digital telemetry interface for host-side handling.
Is BCM6123TD1E5126T01 suitable for renewable energy storage systems?
Yes. The BCM6123TD1E5126T01's 260-410V input window is a strong match for HV battery banks and PV string inverters producing intermediate voltages in that range, and the 4242 VDC isolation simplifies ground-isolation requirements in storage cabinets. Combined with 97.9% peak efficiency and 1876 W/in³ density, it enables compact, efficient battery-to-bus conversion at the megawatt scale.
What cooling does the BCM6123TD1E5126T01 require for full 1.2kW output?
To deliver the full 1220 W at 25.7 A continuous, the BCM6123TD1E5126T01 must be cooled with forced air (typically 200-400 LFM) or a cold-plate attached to the ChiP base, per the Vicor datasheet thermal curves. The through-hole ChiP package offers a low thermal resistance path, but at near-ambient temperatures above 70°C the part will derate output current. For multi-kW parallel arrays follow Vicor's recommended thermal interface guidelines.

Datos de referencia de ingeniería para BCM6123TD1E5126T01 — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose BCM6123TD1E5126T01 when your power-distribution tree uses a 380V nominal (260-410V operating window) primary bus, you need a tightly regulated 47.5V intermediate rail, and you want to leverage the T01 telemetry channel for host-side monitoring. If telemetry is not required, step down to BCM6123TD1E5126T00 for equivalent electrical performance at lower cost. Choose BCM6123TD1E5440T01 instead if your downstream converters prefer a 48.0V intermediate bus, and pick the BCM6123TD1E4263T01 (32.4V) only when the intermediate rail is intentionally tuned for a specific PoL input window. All five parts share the BCM6123 ChiP through-hole footprint, so the same PCB layout accepts the entire family - test with the closest ratio first, then drop in the alternative when production volumes justify the alternate telemetry or voltage profile.

Comparación con alternativas

Parámetro Este producto BCM6123TD1E5126T00 BCM6123TD1E5440T01 BCM6123TD1E4263T01 BCM6123TD1E5135T00 BCM6123TD1E5115T01
Brand Vicor Vicor Vicor Vicor Vicor Vicor
Package BCM6123 through-hole ChiP BCM6123 through-hole ChiP BCM6123 through-hole ChiP BCM6123 through-hole ChiP BCM6123 through-hole ChiP BCM6123 through-hole ChiP
Transformation Ratio (K) 1/8 1/8 1/8 1/8 1/8 1/8
Nominal Output Voltage 47.5 V 47.5 V 48.0 V 32.4 V 51.0 V 45.0 V
Continuous Output Current 25.7 A 25.7 A 26.0 A 31.3 A 24.0 A 27.2 A
Peak Efficiency 97.9% 97.9% 97.9% 97.9% 97.7% 97.7%
Input Voltage Range 260-410 V 260-410 V 260-410 V 260-410 V 260-410 V 260-410 V
Telemetry / Digital I/O Yes (T01 device grade) No (T00 device grade) Yes (T01) Yes (T01) No (T00) Yes (T01)
Isolation Voltage 4242 VDC 4242 VDC 4242 VDC 4242 VDC 4242 VDC 4242 VDC

Diferenciadores clave

  • Telemetry-enabled device grade (T01) adds digital fault reporting (frente a BCM6123TD1E5126T00)
  • Closest fixed-ratio match in the BCM6123 family (frente a BCM6123TD1E5440T01)
  • Higher output current at slightly lower voltage (frente a BCM6123TD1E4263T01)

Notas de diseño

At 1220 W output and 97.9% peak efficiency the worst-case dissipation is about 26 W, but real-world operation at the 380 V/47.5 V point typically lands at 95-97% efficiency so the ChiP sheds 35-60 W into the chassis. Pair the BCM6123 through-hole ChiP with Vicor's reference cold-plate or a thermal interface material rated for >=2 W/m-K and a 200-400 LFM forced-air stream. Add a thermistor in the heatsink's airflow path to monitor the T01 telemetry channel and feed it back for derating.

Use the land pattern supplied in the Vicor BCM6123 ChiP datasheet; deviations invalidate isolation and thermal performance. Recommended: 4 oz copper minimum for the input/output power planes, with thermal vias 0.3 mm diameter spaced 1.0 mm apart under the ChiP base. Keep the high-frequency switching loops - input and output bypass capacitors to the ChiP terminals - within 10 mm to minimize radiated EMI. Pin-compatibility between BCM6123TD1E5126T01 and the BCM6123TD1E5126T00/T440/T263/T135/T115 family lets the same layout accept any of those variants.

Do not parallel the BCM6123TD1E5126T01 with a non-telemetry T00 grade and treat them as identical for safety analyses - the T01 contains firmware-driven fault assertions through the telemetry channel that a T00 device may not honour. Also: never operate this BCM below 260 V input; the under-voltage lockout will force a hard shutdown below that point. Estimate: 97.9% efficiency derives from the manufacturer datasheet figure; calculated mid-load numbers above derive from estimated ratio curves and should be confirmed in-system.

Información de cumplimiento

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Libre de plomo
Unknown
Libre de halógenos
Unknown
Minerales en conflicto
Unknown

Compliance flags were not surfaced in the verified web data; refer to the Vicor BCM6123 product page or manufacturer compliance letter for the latest RoHS/REACH declarations.

Datos verificados el: 2026-10-14 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

BCM6123TD1E5126T01 BCM6123TD1E5126T01 datasheet Vicor BCM6123 bus converter 380V 380V to 48V DC-DC converter 1.2kW Vicor ChiP through-hole BCM module BCM6123 industrial battery bus conversion BCM6123TD1E5126T01 vs DCM2322T72S13A0T60 buy BCM6123TD1E5126T01 in stock BCM6123TD1E5126T01 price per unit how to parallel Vicor BCM6123 modules BCM6123TD1E5126T01 lead time 2026 factorized power architecture 380V bus converter

Componentes & términos relacionados

Vicor BCM6123TD1E5126T01 BCM6123TD1E5126T00 BCM6123TD1E5440T01 BCM6123TD1E4263T01 BCM6123TD1E5135T00 BCM6123TD1E5115T01 DCM2322T72S13A0T60 BCM (Bus Converter Module) Sine Amplitude Converter (SAC) Factorized Power Architecture (FPA) DC-DC converter isolated DC-DC intermediate bus through-hole ChiP package telecommunications rectifier PMBus / digital telemetry industrial three-phase rectifier battery storage system IEC 61851 / IEC 61287-1
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
Total: $0.00 USD
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ