ICL7106CQH-D - 3.5-Digit LCD ADC | Analog Devices
N.º de pieza: ICL7106CQH-D ✓ ActivoICL7106CQH-D Descripción general
The ICL7106 is a low-power analog-to-digital converter with integrated LCD display-drive capability. In a typical measurement chain, an analog sensor signal is conditioned, applied between the differential input terminals, and referenced against the internal or external reference arrangement. The converter then produces a three-and-a-half-digit result for direct display, reducing the need for a separate display controller. Its differential input and reference architecture supports ratiometric measurements involving resistive sensors and bridge transducers.
Key characteristics include 3.5-digit resolution, LCD display-driver output, dual-slope conversion, one analog input channel, and J-lead termination in a 44-PLCC package. The ICL7106 family also includes the ICL7107, which is electrically related but intended for LED-display rather than LCD-display designs. The zero-integrator phase introduced for the ICL7106 and ICL7107 reduces overrange hangover and hysteresis effects, helping the converter return predictably to the normal conversion cycle after an overload condition.
The ICL7106CQH-D is commonly used in digital panel meters, handheld meters, laboratory instruments, weighing equipment, temperature measurement, pressure measurement, and other systems that need a local numerical LCD readout. The commercial temperature grade and 44-pin surface-mount PLCC package make it appropriate for compact industrial and instrument designs where a traditional DIP implementation would be too large.
Designers should preserve the reference and input signal paths for low error, provide suitable bypassing close to the supply pins, and follow the manufacturer’s external-component recommendations. The reference arrangement directly affects full-scale conversion accuracy, while the input network must keep leakage, noise, and source resistance within the limits of the selected integration and reference scheme.
This page combines manufacturer product information, distributor availability and pricing context, package details, replacement guidance, and practical application notes. It is intended to help engineers identify the correct ICL7106 variant, distinguish LCD from LED display versions, and plan a board-level implementation using the 44-PLCC footprint.
Alternativas directas para ICL7106CQH-D — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
Variantes de esta serie
Modelos de la misma serie compatibles directamente con ICL7106CQH-D (mismo factor de forma y huella) — difiere en Display Output, Mounting Type, Package.
ICL7106CQH+TD
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
ICL7107CQH+D
✅ Sustitución directaConsulte el precio
Ver hoja de datos →ICL7106CQH-D Valores máximos y características eléctricas
| Función | 3.5-digit A/D converter with LCD display driver |
| Display Resolution | 3.5 digits |
| Conversion Type | Dual-slope |
| Input Channels | 1 channel |
| Input Architecture | True differential input |
| Reference Architecture | True differential reference |
| Display Output | 7-segment LCD driver |
| Encapsulado | 44-PLCC, J-lead, 16.59 mm x 16.59 mm |
| Recuento de pines | 44 pins |
| Tipo de montaje | Surface mount |
| Terminal Form | J-bend |
| Package Code | HQCCJ |
| Temperature Grade | Commercial |
| Overrange Behavior | Zero-integrator phase reduces overrange hangover and hysteresis effects |
| Measurement Mode | Ratiometric measurements supported |
Guía de configuración de pines de ICL7106CQH-D hqccj
Configuración de pines para ICL7106CQH-D (encapsulado hqccj). Este componente analógico presenta pines de entrada, salida y alimentación. Consulte la hoja de datos del fabricante para conocer las configuraciones de los pines de ajuste de offset, compensación y habilitación. Ideal para circuitos de acondicionamiento de señal y amplificadores.
No hay datos detallados de patillaje disponibles para ICL7106CQH-D.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
ICL7106CQH-D es adecuado para 6 aplicacións: Digital Panel Meter, Laboratory Measurement Instrument, Temperature Measurement, Pressure and Bridge Instrumentation, Handheld Meter, Weighing Scale Display.
Digital Panel Meter
The ICL7106CQH-D is appropriate for a compact digital panel meter because it combines a 3.5-digit dual-slope A/D converter with a 7-segment LCD display driver. A conditioned sensor signal can be applied to the true differential input, referenced to the true differential reference arrangement, and converted for direct display without a separate display-controller IC. The integrated display drive reduces board area and firmware overhead, while the 44-PLCC J-lead package provides a manageable surface-mount footprint for industrial instrumentation. Design the reference and input networks so their source resistance, leakage and noise remain suitable for the selected conversion scheme.
Recomendado
Laboratory Measurement Instrument
A laboratory meter can use the ICL7106CQH-D to convert a conditioned analog measurement into a stable 3.5-digit result displayed on LCD glass. The dual-slope architecture is suited to measurement systems where the input is referenced to a known source, while the true differential input and reference reduce sensitivity to common-mode changes. A temperature, pressure or laboratory transducer can feed the converter through a protected, low-noise analog front end. Keep high-impedance nodes guarded, maintain stable reference components and follow the manufacturer’s recommended bypass and integration components to preserve conversion accuracy.
Recomendado
Temperature Measurement
The ICL7106CQH-D is suitable for displaying temperature measured by a resistive sensor because its differential input and reference arrangement supports ratiometric measurements. The sensor can form a divider with a precision reference resistor, and the converter reports the resulting ratio as a 3.5-digit LCD value. Ratiometric operation helps the displayed result track excitation-voltage variation rather than transferring that variation directly into the measurement error. The analog section should still account for sensor self-heating, lead resistance, leakage and resistor tolerance, while the LCD and conversion timing should be configured according to the manufacturer data sheet.
Recomendado
Pressure and Bridge Instrumentation
The ICL7106CQH-D can form the measurement and display section of a bridge-based pressure instrument. The true differential input accepts the bridge excitation and sensed bridge output, while the true differential reference supports ratio-based measurement. This arrangement is useful where the output is proportional to excitation and mechanical stress. The 3.5-digit LCD result provides a readable local value without requiring a separate display controller. Compensation for bridge sensitivity, offset, temperature drift and sensor nonlinearity belongs in the analog or digital signal chain; the converter should receive a conditioned signal and a stable reference.
Recomendado
Handheld Meter
A handheld meter benefits from the ICL7106CQH-D because it integrates conversion and LCD display drive in one 44-PLCC device. This can simplify a battery-powered product that must show a direct numerical reading from a resistive or bridge sensor. The dual-slope, 3.5-digit converter supports compact panel-meter layouts, while the LCD output avoids the continuous power and area demands of a multi-digit LED display. Board-level design should account for battery-range limits, display visibility, input protection and reference stability. Low-leakage parts and clean routing around the differential input are especially important in high-impedance handheld measurements.
Recomendado
Weighing Scale Display
The ICL7106CQH-D is well suited to a basic weighing-scale readout when the load cell is conditioned into a differential measurement and the result is displayed to 3.5 digits. Ratiometric excitation and reference arrangements help cancel gain changes associated with the power supply or bridge excitation. The integrated LCD driver provides a direct, low-component-count display path suitable for bench scales, portable scales and compact industrial indicators. Mechanical stability, common-mode input range, reference accuracy and calibration determine the practical resolution. Use the manufacturer’s component values and timing arrangement to avoid offset, noise and integration-period errors.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para ICL7106CQH-D — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | ICL7106CQH+TD | ICL7107CQH+D |
|---|---|---|---|
| Package | 44-PLCC, J-lead | 44-PLCC, J-bend | 44-PLCC |
| Brand | Analog Devices | Maxim Integrated | Analog Devices |
| Resolution | 3.5 digits | 3.5 digits | 3.5 digits |
| Conversion Type | Dual-slope | Dual-slope | Dual-slope |
| Input Channels | 1 channel | 1 channel | 1 channel |
| Display Type | LCD | LCD | LED |
| Display Driver | 7-segment LCD display driver | LCD display driver | LED display driver |
| Mounting Type | Surface mount | Surface mount | Surface mount |
| Pin Count | 44 pins | 44 pins | 44 pins |
Diferenciadores clave
- Integrated LCD display drive (frente a ICL7107CQH+D)
- Differential measurement architecture (frente a ICL7107CQH+D)
- Exact commercial 44-PLCC orderable (frente a ICL7106CQH+TD)
Notas de diseño
Route the true differential input and reference as compact, symmetric paths and keep switching or display-related return currents away from the converter. Place bypass capacitors at the appropriate supply pins using the values and layout shown in the manufacturer application guidance. The 44-PLCC J-lead footprint should be checked mechanically against the 16.59 mm square body, and the PCB must provide adequate clearance between adjacent fine-pitch leads to prevent solder bridging.
Treat the input and reference networks as precision analog paths. Use low-leakage components, guard high-impedance nodes where necessary and minimize PCB contamination around exposed inputs. Ratiometric measurements can reduce excitation-related error, but resistor tolerance, sensor self-heating and leakage still influence the displayed value. Establish the allowable error budget and verify the complete analog front end at the intended input impedance and temperature range rather than relying only on nominal converter resolution.
Do not interchange the ICL7106 LCD-display device with the ICL7107 LED-display device solely because both use a 44-PLCC package. Also avoid treating the ICL7106C/D die as a board-level substitute for the finished ICL7106CQH-D package. Confirm the exact orderable suffix, display technology, temperature grade, pin mapping and external circuitry on the schematic before releasing a replacement into production.
Información de cumplimiento
The manufacturer product page identifies the ICL7106 as a production device, but the available product information does not explicitly state RoHS, REACH, lead-free, halogen-free or conflict-minerals status. AEC-Q100 is not applicable to the identified commercial-grade ICL7106CQH-D orderable.