ICL7106CQH-D - 3.5-Digit LCD ADC | Analog Devices
料号: ICL7106CQH-D ✓ 量产中ICL7106CQH-D 概述
The ICL7106 is a low-power analog-to-digital converter with integrated LCD display-drive capability. In a typical measurement chain, an analog sensor signal is conditioned, applied between the differential input terminals, and referenced against the internal or external reference arrangement. The converter then produces a three-and-a-half-digit result for direct display, reducing the need for a separate display controller. Its differential input and reference architecture supports ratiometric measurements involving resistive sensors and bridge transducers.
Key characteristics include 3.5-digit resolution, LCD display-driver output, dual-slope conversion, one analog input channel, and J-lead termination in a 44-PLCC package. The ICL7106 family also includes the ICL7107, which is electrically related but intended for LED-display rather than LCD-display designs. The zero-integrator phase introduced for the ICL7106 and ICL7107 reduces overrange hangover and hysteresis effects, helping the converter return predictably to the normal conversion cycle after an overload condition.
The ICL7106CQH-D is commonly used in digital panel meters, handheld meters, laboratory instruments, weighing equipment, temperature measurement, pressure measurement, and other systems that need a local numerical LCD readout. The commercial temperature grade and 44-pin surface-mount PLCC package make it appropriate for compact industrial and instrument designs where a traditional DIP implementation would be too large.
Designers should preserve the reference and input signal paths for low error, provide suitable bypassing close to the supply pins, and follow the manufacturer’s external-component recommendations. The reference arrangement directly affects full-scale conversion accuracy, while the input network must keep leakage, noise, and source resistance within the limits of the selected integration and reference scheme.
This page combines manufacturer product information, distributor availability and pricing context, package details, replacement guidance, and practical application notes. It is intended to help engineers identify the correct ICL7106 variant, distinguish LCD from LED display versions, and plan a board-level implementation using the 44-PLCC footprint.
直接替换替代料: ICL7106CQH-D ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: ICL7106CQH-D (相同外形与封装尺寸) ——差异在于 Display Output, Mounting Type, Package.
ICL7106CQH+TD
✅ 直接替换📋 参考替代料(不在目录中)
ICL7107CQH+D
✅ 直接替换联系询价
查看数据手册 →ICL7106CQH-D 最大额定值与电气特性
| 功能 | 3.5-digit A/D converter with LCD display driver |
| Display Resolution | 3.5 digits |
| Conversion Type | Dual-slope |
| Input Channels | 1 channel |
| Input Architecture | True differential input |
| Reference Architecture | True differential reference |
| Display Output | 7-segment LCD driver |
| 封装 | 44-PLCC, J-lead, 16.59 mm x 16.59 mm |
| 引脚数量 | 44 pins |
| 安装类型 | Surface mount |
| Terminal Form | J-bend |
| Package Code | HQCCJ |
| Temperature Grade | Commercial |
| Overrange Behavior | Zero-integrator phase reduces overrange hangover and hysteresis effects |
| Measurement Mode | Ratiometric measurements supported |
ICL7106CQH-D hqccj 引脚配置指南
ICL7106CQH-D(hqccj 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: ICL7106CQH-D.
请参阅 数据手册 以查看完整引脚配置。
典型应用
ICL7106CQH-D 适用于 6 应用s: Digital Panel Meter, Laboratory Measurement Instrument, Temperature Measurement, Pressure and Bridge Instrumentation, Handheld Meter, Weighing Scale Display.
Digital Panel Meter
The ICL7106CQH-D is appropriate for a compact digital panel meter because it combines a 3.5-digit dual-slope A/D converter with a 7-segment LCD display driver. A conditioned sensor signal can be applied to the true differential input, referenced to the true differential reference arrangement, and converted for direct display without a separate display-controller IC. The integrated display drive reduces board area and firmware overhead, while the 44-PLCC J-lead package provides a manageable surface-mount footprint for industrial instrumentation. Design the reference and input networks so their source resistance, leakage and noise remain suitable for the selected conversion scheme.
推荐
Laboratory Measurement Instrument
A laboratory meter can use the ICL7106CQH-D to convert a conditioned analog measurement into a stable 3.5-digit result displayed on LCD glass. The dual-slope architecture is suited to measurement systems where the input is referenced to a known source, while the true differential input and reference reduce sensitivity to common-mode changes. A temperature, pressure or laboratory transducer can feed the converter through a protected, low-noise analog front end. Keep high-impedance nodes guarded, maintain stable reference components and follow the manufacturer’s recommended bypass and integration components to preserve conversion accuracy.
推荐
Temperature Measurement
The ICL7106CQH-D is suitable for displaying temperature measured by a resistive sensor because its differential input and reference arrangement supports ratiometric measurements. The sensor can form a divider with a precision reference resistor, and the converter reports the resulting ratio as a 3.5-digit LCD value. Ratiometric operation helps the displayed result track excitation-voltage variation rather than transferring that variation directly into the measurement error. The analog section should still account for sensor self-heating, lead resistance, leakage and resistor tolerance, while the LCD and conversion timing should be configured according to the manufacturer data sheet.
推荐
Pressure and Bridge Instrumentation
The ICL7106CQH-D can form the measurement and display section of a bridge-based pressure instrument. The true differential input accepts the bridge excitation and sensed bridge output, while the true differential reference supports ratio-based measurement. This arrangement is useful where the output is proportional to excitation and mechanical stress. The 3.5-digit LCD result provides a readable local value without requiring a separate display controller. Compensation for bridge sensitivity, offset, temperature drift and sensor nonlinearity belongs in the analog or digital signal chain; the converter should receive a conditioned signal and a stable reference.
推荐
Handheld Meter
A handheld meter benefits from the ICL7106CQH-D because it integrates conversion and LCD display drive in one 44-PLCC device. This can simplify a battery-powered product that must show a direct numerical reading from a resistive or bridge sensor. The dual-slope, 3.5-digit converter supports compact panel-meter layouts, while the LCD output avoids the continuous power and area demands of a multi-digit LED display. Board-level design should account for battery-range limits, display visibility, input protection and reference stability. Low-leakage parts and clean routing around the differential input are especially important in high-impedance handheld measurements.
推荐
Weighing Scale Display
The ICL7106CQH-D is well suited to a basic weighing-scale readout when the load cell is conditioned into a differential measurement and the result is displayed to 3.5 digits. Ratiometric excitation and reference arrangements help cancel gain changes associated with the power supply or bridge excitation. The integrated LCD driver provides a direct, low-component-count display path suitable for bench scales, portable scales and compact industrial indicators. Mechanical stability, common-mode input range, reference accuracy and calibration determine the practical resolution. Use the manufacturer’s component values and timing arrangement to avoid offset, noise and integration-period errors.
推荐
推荐产品汇总
工程参考数据: ICL7106CQH-D ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | ICL7106CQH+TD | ICL7107CQH+D |
|---|---|---|---|
| Package | 44-PLCC, J-lead | 44-PLCC, J-bend | 44-PLCC |
| Brand | Analog Devices | Maxim Integrated | Analog Devices |
| Resolution | 3.5 digits | 3.5 digits | 3.5 digits |
| Conversion Type | Dual-slope | Dual-slope | Dual-slope |
| Input Channels | 1 channel | 1 channel | 1 channel |
| Display Type | LCD | LCD | LED |
| Display Driver | 7-segment LCD display driver | LCD display driver | LED display driver |
| Mounting Type | Surface mount | Surface mount | Surface mount |
| Pin Count | 44 pins | 44 pins | 44 pins |
关键差异点
- Integrated LCD display drive (对比 ICL7107CQH+D)
- Differential measurement architecture (对比 ICL7107CQH+D)
- Exact commercial 44-PLCC orderable (对比 ICL7106CQH+TD)
设计说明
Route the true differential input and reference as compact, symmetric paths and keep switching or display-related return currents away from the converter. Place bypass capacitors at the appropriate supply pins using the values and layout shown in the manufacturer application guidance. The 44-PLCC J-lead footprint should be checked mechanically against the 16.59 mm square body, and the PCB must provide adequate clearance between adjacent fine-pitch leads to prevent solder bridging.
Treat the input and reference networks as precision analog paths. Use low-leakage components, guard high-impedance nodes where necessary and minimize PCB contamination around exposed inputs. Ratiometric measurements can reduce excitation-related error, but resistor tolerance, sensor self-heating and leakage still influence the displayed value. Establish the allowable error budget and verify the complete analog front end at the intended input impedance and temperature range rather than relying only on nominal converter resolution.
Do not interchange the ICL7106 LCD-display device with the ICL7107 LED-display device solely because both use a 44-PLCC package. Also avoid treating the ICL7106C/D die as a board-level substitute for the finished ICL7106CQH-D package. Confirm the exact orderable suffix, display technology, temperature grade, pin mapping and external circuitry on the schematic before releasing a replacement into production.
合规信息
The manufacturer product page identifies the ICL7106 as a production device, but the available product information does not explicitly state RoHS, REACH, lead-free, halogen-free or conflict-minerals status. AEC-Q100 is not applicable to the identified commercial-grade ICL7106CQH-D orderable.